Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum machine learning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Quantum chemical calculations of lithium-ion battery electrolyte and interphase species

Abstract Lithium-ion batteries (LIBs) represent the state of the art in high-density energy storage. To further advance LIB technology, a fundamental understanding of the underlying chemical processes is required. In particular, the decomposition of electrolyte species and associated formation of the solid electrolyte interphase (SEI) is critical for LIB performance. However, SEI formation is poorly understood, in part due to insufficient exploration of the vast reactive space. The Lithium-Ion Battery Electrolyte (LIBE) dataset reported here aims to provide accurate first-principles data to improve the understanding of SEI species and associated reactions. The dataset was generated by fragmenting a set of principal molecules, including solvents, salts, and SEI products, and then selectively recombining a subset of the fragments. All candidate molecules were analyzed at the ω B97X-V/def2-TZVPPD/SMD level of theory at various charges and spin multiplicities. In total, LIBE contains structural, thermodynamic, and vibrational information on over 17,000 unique species. In addition to studies of reactivity in LIBs, this dataset may prove useful for machine learning of molecular and reaction properties.

25 ENERGY STORAGE↗

Using Computationally-Determined Properties for Machine Learning Prediction of Self-Diffusion Coefficients in Pure Liquids

The ability to predict transport properties of liquids quickly and accurately will greatly improve our understanding of fluid properties both in bulk and complex mixtures, as well as in confined environments. Such information could then be used in the design of materials and processes for applications ranging from energy production and storage to manufacturing processes. As a first step, we consider the use of machine learning (ML) methods to predict the diffusion properties of pure liquids. Recent results have shown that Artificial Neural Networks (ANNs) can effectively predict the diffusion of pure compounds based on the use of experimental properties as the model inputs. In the current study, a similar ANN approach is applied to modeling diffusion of pure liquids using fluid properties obtained exclusively from molecular simulations. A diverse set of 102 pure liquids is considered, ranging from small polar molecules (e.g., water) to large nonpolar molecules (e.g., octane). Self-diffusion coefficients were obtained from classical molecular dynamics (MD) simulations. Since nearly all the molecules are organic compounds, a general set of force field parameters for organic molecules was used. The MD methods are validated by comparing physical and thermodynamic properties with experiment. Computational input features for the ANN include physical properties obtained from the MD simulations as well as molecular properties from quantum calculations of individual molecules. Furthermore, fluid properties describing the local liquid structure were obtained from center of mass radial distribution functions (COM-RDFs). Feature sensitivity analysis revealed that isothermal compressibility, heat of vaporization, and the thermal expansion coefficient were the most impactful properties used as input for the ANN model to predict the MD simulated self-diffusion coefficients. The MD-based ANN successfully predicts the MD self-diffusion coefficients with only a subset (2 to 3) of the available computationally determined input features required. A separate ANN model was developed using literature experimental self-diffusion coefficients as model targets. Although this second ML model was not as successful due to a limited number of data points, a good correlation is still observed between experimental and ML predicted self-diffusion coefficients.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed-Memory Sparse Deep Neural Network Inference Using Global Arrays

Partitioned Global Address Space (PGAS) models exhibit tremendous promise in developing efficient and productive distributed-memory parallel applications. They have been used extensively in scientific computations due to conveniently offering a ``shared-memory''-like model and convenient interfaces that separate communication with synchronization. Traditionally, PGAS communication models have been applied to dense/contiguously distributed data, but most modern applications depict varied levels of sparsity. Existing PGAS models require certain adaptations to support distributed sparse computations, since associated computations often require matrix arithmetic, in addition to data movement. The Global Arrays toolkit from Pacific Northwest National Laboratory (PNNL) is one of the earliest PGAS models to combine one-sided data communication and distributed matrix operations and is still used in the popular NWChem quantum chemistry suite. Recently, we have expanded the Global Arrays toolkit to support common sparse operations, like sparse matrix-dense matrix multiplies (SpMM), sparse matrix-sparse matrix multiplication (SpGEMM) and Sampled Dense-Dense Matrix Multiplication (SDDMM). As it turns out, these operations are the bedrock of sparse Deep Learning (DL); sparse deep neural networks and Graph Neural Networks (GNNs) have gained increasing attention recently in achieving speedups on training and inference with reduced memory footprints. Unlike scientific applications in High Performance Computing (HPC), modern (distributed-memory capable) DL toolkits often rely on non-standardized and closed-source vendor software optimizations, creating challenges in software-hardware co-design at scale. Our goal is to support a variety of distributed-memory sparse matrix operations and helper functions in the newly created Sparse Global Arrays (SGA), such that it is possible to build portable and productive Machine Learning scenarios for algorithm/software and hardware codesign purposes. Contemporary data-parallel schemes for training/inference are undergoing a major overhaul since model replication limits scalability and causes resource inefficiencies. As such, we have adopted tensor parallelism in decomposing the model and inputs, to mitigate memory issues. Current implementation is built on top of MPI and uses CPUs to maximize the portability across the platforms.

Distributed computing, machine learning↗

Efficient prediction of attosecond two-colour pulses from an X-ray free-electron laser with machine learning

Abstract X-ray free-electron lasers are sources of coherent, high-intensity X-rays with numerous applications in ultra-fast measurements and dynamic structural imaging. Due to the stochastic nature of the self-amplified spontaneous emission process and the difficulty in controlling injection of electrons, output pulses exhibit significant noise and limited temporal coherence. Standard measurement techniques used for characterizing two-coloured X-ray pulses are challenging, as they are either invasive or diagnostically expensive. In this work, we employ machine learning methods such as neural networks and decision trees to predict the central photon energies of pairs of attosecond fundamental and second harmonic pulses using parameters that are easily recorded at the high-repetition rate of a single shot. Using real experimental data, we apply a detailed feature analysis on the input parameters while optimizing the training time of the machine learning methods. Our predictive models are able to make predictions of central photon energy for one of the pulses without measuring the other pulse, thereby leveraging the use of the spectrometer without having to extend its detection window. We anticipate applications in X-ray spectroscopy using XFELs, such as in time-resolved X-ray absorption and photoemission spectroscopy, where improved measurement of input spectra will lead to better experimental outcomes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tracking atomic structure evolution during directed electron beam induced Si-atom motion in graphene via deep machine learning

Using electron beam manipulation, we enable deterministic motion of individual Si atoms in graphene along predefined trajectories. Structural evolution during the dopant motion was explored, providing information on changes of the Si atom neighborhood during atomic motion and providing statistical information of possible defect configurations. The combination of a Gaussian mixture model and principal component analysis applied to the deep learning-processed experimental data allowed disentangling of the atomic distortions for two different graphene sublattices. This approach demonstrates the potential of e-beam manipulation to create defect libraries of multiple realizations of the same defect and explore the potential of symmetry breaking physics. The rapid image analytics enabled via a deep learning network further empowers instrumentation for e-beam controlled atom-by-atom fabrication. Here, the analysis described in the paper can be reproduced via an interactive Jupyter notebook at https://git.io/JJ3Bx.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of formalisms based on locally coupled open subsystems for calculations in molecular electronic structure and dynamics

Quantum embedding theories model a collection of interacting molecules as a set of subsystems, where each can be treated with a particular electronic structure method (wave function or density functional theory, for example); these theories can lead to computationally efficient and accurate algorithms. Motivated by challenges in the field, we previously described a formalism (that models two subsystems), which we call “locally coupled open subsystems” (LCOS), for the computation of ground-state energies, fractional electron-occupation numbers of the subsystems, and the size-consistent limit of subsystem dissociation. In this work we present the full (nonrelativistic) LCOS theory and the following extensions of our previous work: (i) the framework to study systems composed of multiple subsystems and a procedure to spin-adapt the auxiliary wave function that describes the partitioned system, so that its spin state matches that of the real system of interest; (ii) potential functionals and ideas to employ machine learning for the computation of ground-state densities and energies; (iii) formulation of two LCOS ground-state approaches where the fragments are assigned Kohn-Sham wave functions; and (iv) a time-dependent (TD) extension of these two ground-state formalisms in which the state of the subsystems evolves according to a unitary propagation; from this evolution we can extract TD electron populations of the fragments, for instance. We also discuss potential applications of the TD LCOS theory to linear photoabsorption and Raman spectroscopy. As a result, the developments presented in this work can lead to ground-state and TD electronic structure calculations where the computational scaling can be controlled, depending on the level of theory and the accuracy desired to model each one of the subsystems and their coupling.

74 ATOMIC AND MOLECULAR PHYSICS↗

matsim-agents v1.0

matsim-agents is a multi-agent AI framework for atomistic materials simulation and discovery. It orchestrates large language models (LLMs), machine-learned interatomic potentials (MLIPs), and DFT codes into a single agentic loop running on laptops and DOE leadership-class supercomputers. MULTI-AGENT ORCHESTRATION A LangGraph state machine with three nodes: a Planner that converts a natural-language research objective into structured tasks; an Executor that dispatches atomistic tools and loops until the queue is empty; and an Analyst that summarizes results into a human-readable report. State is checkpointed after every step and human-in-the-loop gates can be inserted at any edge. HYPOTHESIS-DRIVEN DISCOVERY CHAT An interactive REPL (matsim-agents chat) that couples LLM dialogue with atomistic simulation. Chemical formulas are automatically detected in conversation turns and trigger a full crystal-phase exploration: structure generation → relaxation → stability scoring → result injection back into the conversation, creating a closed hypothesis-refinement loop. CRYSTAL PHASE ENUMERATION Given a composition, the phase explorer enumerates prototypes by stoichiometry: elemental (fcc/bcc/hcp/sc/diamond), binary 1:1 (rocksalt/CsCl/zincblende/ wurtzite/fluorite/rutile), ternary 1:1:3 (cubic perovskite), ternary 1:2:4 (perovskite + spinel), quaternary 1:1:2:6 (Fm-3m double perovskite). 2-D prototypes (graphene, h-BN, MoS2 2H/1T) and multilayer stacking are also supported via --include-2d and --num-layers. SUPERCELL GENERATION AND SITE DECORATION Auto-tiling to a minimum atom count (--min-atoms), explicit NxNxN tiling (--supercell), symmetry-distinct site decorations (--n-orderings), and isotropic lattice-scale sweeps (--lattice-scales) for volume bracketing. MLFF RELAXATION AND STABILITY SCORING HydraGNN (multi-headed GNN) drives structure relaxation via ASE with FIRE, BFGS, or BFGSLineSearch. Stability output: delta-E/atom ranking across phases and a max-residual-force dynamical-stability proxy. Other MLIPs (MACE, NequIP, Orb) can be plugged in through the same interface. DFT BACKENDS Quantum ESPRESSO pw.x and VASP 6.6 are first-class labellers. Both have validated GPU builds and SLURM/PBS launchers for three DOE platforms: Frontier (AMD MI250X, ROCm), Aurora (Intel PVC, oneAPI), Perlmutter (NVIDIA A100, CUDA). QE produces ~100 binaries (pw.x, ph.x, epw.x, ...). VASP supports scf, relax, vc-relax, and vc-relax-shape run types. ACTIVE-LEARNING LOOP matsim-agents al run CONFIG.yaml drives an iterative HydraGNN-DFT loop: MD generates candidates → ensemble/MC-dropout uncertainty selects the most informative → DFT labels them in parallel inside one allocation → dataset grows → HydraGNN retrains → repeat. DFT backend is a single YAML toggle (dft.backend: vasp | qe). LLM-generated seed structures are supported (no curated POSCAR library needed). Config uses ${VAR}, ${VAR:-default}, ${VAR:?msg} shell-style substitution for cross-user/cross-site portability. LLM BACKENDS Ollama (local, default), vLLM (HPC multi-GPU serving), OpenAI, Anthropic, HuggingFace Transformers+Accelerate. Selected at runtime via flag or env var with no code changes. HPC PORTABILITY Same Python entry points run on Frontier (ROCm 7.2), Aurora (oneAPI), and Perlmutter (CUDA 12). DFT and ML stacks are never co-loaded in the same shell; they couple through the scheduler and filesystem. Advanced multi-node launchers (serve, discovery-chat, single-relaxation, active-learning, QE warm-start) are provided for all three platforms. CODABENCH COMPETITION BUNDLE A self-contained benchmark: 159 atomistic test structures across 11 material classes, 5 tasks (formation energy, forces, ML relaxation, AI-DFT relaxation, phase stability ranking), public/private leaderboard split (30/70), and four ready-to-run baselines: MACE-MP-0, HydraGNN, UMA, AllScAIP.

Lupo Pasini, Massimiliano [Oak Ridge National Labo↗

SA-GAT-SR: self-adaptable graph attention networks with symbolic regression for high-fidelity material property prediction

Recent advances in machine learning have demonstrated an enormous utility of deep learning approaches, particularly Graph Neural Networks (GNNs) for materials science. These methods have emerged as powerful tools for high-throughput prediction of material properties, offering a compelling enhancement and alternative to traditional first-principles calculations. While the community has predominantly focused on developing increasingly complex and universal models to enhance predictive accuracy, such approaches often lack physical interpretability and insights into materials behavior. Here, we introduce a novel computational paradigm—Self-Adaptable Graph Attention Networks integrated with Symbolic Regression (SA-GAT-SR)—that synergistically combines the predictive capability of GNNs with the interpretative power of symbolic regression. Our framework employs a self-adaptable encoding algorithm that automatically identifies and adjust attention weights so as to screen critical features from an expansive 180-dimensional feature space while maintaining O(n) computational scaling. The integrated SR module subsequently distills these features into compact analytical expressions that explicitly reveal quantum-mechanically meaningful relationships, achieving 23 × acceleration compared to conventional SR implementations that heavily rely on first-principle calculations-derived features as input. This work suggests a new framework in computational materials science, bridging the gap between predictive accuracy and physical interpretability, offering valuable physical insights into material behavior.

36 MATERIALS SCIENCE↗

Role of electron correlation on the adenine dimer interaction for non-equilibrium geometries: a benchmark Quantum Monte Carlo study

The accurate description of non-covalent interactions is critical for understanding the structure, dynamics, and eventual function of biomolecules. The adenine dimer serves as a benchmark system for computational methods due to its role in nucleic acid structures and its rich conformational landscape. In this study, we employ benchmark diffusion quantum Monte Carlo (DMC) methods to investigate the relative energies and role of electron correlation on a set of adenine dimer conformations generated via a search of the potential energy landscape using the global optimizer algorithm. Relative DMC energies are compared against a wide range of density functional theory (DFT) approximation results. We find that although most of the DFT functionals perform well for low-energy structures, their accuracy varies significantly for higher-energy conformations, including stacked and T-shaped structures. A large fraction of the variation is due to the treatment of the van der Waals interaction. BLYP, B3LYP, and PBE0 significantly improve with added D4 dispersion, while the recent r2SCAN-D4 and ωB97M-V functionals show the least scatter and closest agreement with the DMC. These findings highlight the delicate nature of these interactions in biomolecular systems and provide guidance for simulations of their structure and dynamics and for the development of machine learned interatomic potentials.

Washburn, Laurel [ORNL] (ORCID:0000000324179335)↗

Building surrogate models of nuclear density functional theory with Gaussian processes and autoencoders

From the lightest Hydrogen isotopes up to the recently synthesized Oganesson (Z = 118), it is estimated that as many as about 8,000 atomic nuclei could exist in nature. Most of these nuclei are too short-lived to be occurring on Earth, but they play an essential role in astrophysical events such as supernova explosions or neutron star mergers that are presumed to be at the origin of most heavy elements in the Universe. Understanding the structure, reactions, and decays of nuclei across the entire chart of nuclides is an enormous challenge because of the experimental difficulties in measuring properties of interest in such fleeting objects and the theoretical and computational issues of simulating strongly-interacting quantum many-body systems. Nuclear density functional theory (DFT) is a fully microscopic theoretical framework which has the potential of providing such a quantitatively accurate description of nuclear properties for every nucleus in the chart of nuclides. Thanks to high-performance computing facilities, it has already been successfully applied to predict nuclear masses, global patterns of radioactive decay like β or γ decay, and several aspects of the nuclear fission process such as, e.g., spontaneous fission half-lives. Yet, predictive simulations of nuclear spectroscopy—the low-lying excited states and transitions between them—or of nuclear fission, or the quantification of theoretical uncertainties and their propagation to basic or applied nuclear science applications, would require several orders of magnitude more calculations than currently possible. However, most of this computational effort would be spent into generating a suitable basis of DFT wavefunctions. Such a task could potentially be considerably accelerated by borrowing tools from the field of machine learning and artificial intelligence. In this paper, we review different approaches to applying supervised and unsupervised learning techniques to nuclear DFT.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An electrostatic spectral neighbor analysis potential for lithium nitride

Machine-learned interatomic potentials based on local environment descriptors represent a transformative leap over traditional potentials based on rigid functional forms in terms of prediction accuracy. However, a challenge in their application to ionic systems is the treatment of long-ranged electrostatics. Here, we present a highly accurate electrostatic Spectral Neighbor Analysis Potential (eSNAP) for ionic α-Li 3 N, a prototypical lithium superionic conductor of interest as a solid electrolyte or coating for rechargeable lithium-ion batteries. We show that the optimized eSNAP model substantially outperforms traditional Coulomb–Buckingham potential in the prediction of energies and forces, as well as various properties, such as lattice constants, elastic constants, and phonon dispersion curves. We also demonstrate the application of eSNAP in long-time, large-scale Li diffusion studies in Li 3 N, providing atomistic insights into measures of concerted ionic motion (e.g., the Haven ratio) and grain boundary diffusion. This work aims at providing an approach to developing quantum-accurate force fields for multi-component ionic systems under the SNAP formalism, enabling large-scale atomistic simulations for such systems.

36 MATERIALS SCIENCE↗

Going off topics to demix quark and gluon jets in α S extractions

Quantum chromodynamics is the theory of the strong interaction between quarks and gluons; the coupling strength of the interaction, α S , is the least precisely-known of all interactions in nature. An extraction of the strong coupling from the radiation pattern within jets would provide a complementary approach to conventional extractions from jet production rates and hadronic event shapes, and would be a key achievement of jet substructure at the Large Hadron Collider (LHC). Presently, the relative fraction of quark and gluon jets in a sample is the limiting factor in such extractions, as this fraction is degenerate with the value of αS for the most well-understood observables. To overcome this limitation, we apply recently proposed techniques to statistically demix multiple mixtures of jets and obtain purified quark and gluon distributions based on an operational definiton. We illustrate that studying quark and gluon jet substructure separately can significantly improve the sensitivity of such extractions of the strong coupling. We also discuss how using machine learning techniques or infrared- and collinear-unsafe information can improve the demixing performance without the loss of theoretical control. While theoretical research is required to connect the extract topics with the quark and gluon objects in cross section calculations, our study illustrates the potential of demixing to reduce the dominant uncertainty for the α S extraction from jet substructure at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of disorder on thermodynamic instability of binary Rare-earth – Nickel – Palladium compounds

In this work, we have investigated the thermodynamic stability of disordered rare-earth phases SmX 2 and Sm 10 X 21 (X=Ni, Pd) using machine-learning based analytical descriptor and first-principles density functional theory methods. The absence of Laves phase compounds in R-Pd binary systems is a longstanding problem of rare earth science: even though Ni and Pd belong to the same group of the periodic table and have similar electronic structure, the Pd compound crystallizes in a monoclinic (C2/m) phase with 10:21 stoichiometry, i.e., Sm 10 Pd 21 , while the Ni compound adopts a cubic Laves phase (MgCu 2 ) structure. To understand this contrasting phase stability, we performed thermodynamic convex hull analysis of Sm x Ni 1-x and Sm x Pd 1-x binary systems, which is experimentally validated using powder X-ray diffraction (PXRD) analyzes of polycrystalline Sm(Ni x Pd 1-x ) 2 samples with x=0, 0.5, and 1. A detailed electronic-structure (band-structure, charge density, and Fermi-surface) analysis of the differences between SmNi 2 /SmPd 2 and Sm 10 Ni 21 /Sm 10 Pd 21 compounds provides the quantum mechanical origin of the unfavorable mixing of Pd with Ni in cubic Laves phase. We show that the stability of Sm-Pd in 10:21 stoichiometry arises from improved intra-/inter-layer 5d-4d bonding compared to the 1:2 stoichiometry. Our work emphasizes the importance of ab-initio methods and computationally inexpensive analytical descriptors for the detailed analysis of thermodynamic and electronic properties of hard-to-prepare rare-earth compounds.

36 MATERIALS SCIENCE↗

High-precision inversion of dynamic radiography using hydrodynamic features

While radiography is routinely used to probe complex, evolving density fields in research areas ranging from materials science to shock physics to inertial confinement fusion and other national security applications, complications resulting from noise, scatter, complex beam dynamics, etc. prevent current methods of reconstructing density from being accurate enough to identify the underlying physics with sufficient confidence. In this work, we show that using only features that are robustly identifiable in radiographs and combining them with the underlying hydrodynamic equations of motion using a machine learning approach of a conditional generative adversarial network (cGAN) provides a new and effective approach to determine density fields from a dynamic sequence of radiographs. In particular, we demonstrate the ability of this method to outperform a traditional, direct radiograph to density reconstruction in the presence of scatter, even when relatively small amounts of scatter are present. Our experiments on synthetic data show that the approach can produce high quality, robust reconstructions. We also show that the distance (in feature space) between a testing radiograph and the training set can serve as a diagnostic of the accuracy of the reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-EF-BRA-00: MR Basics I

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI (f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-01: NMR and Proton Density MRI of the 1D Patient

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-02: Longitudinal Proton Spin Relaxation and T1-Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-03: Free Induction Decay (without the Decay) and Spin-Echo Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗