Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process design and operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Bridging the Gap Between Pure and Mixed-Gas Performance of Thin-Film Composite Membranes

This study examines the influence of cell design on mixed-gas testing with PolyActive™ TFC membranes, featuring pure-gas CO₂ permeance of 1700–3100 GPU, representative of state-of-the-art CO₂/N₂ separation membranes. By designing and 3D-printing a counter-current permeation cell with optimized flow efficiency, we achieved a 33–41% increase in mixed-gas CO₂ permeance compared to traditional cells. Additionally, a comparison of sweep-gas and vacuum permeation methods revealed that vacuum operation mitigates downstream polarization, enhancing mixed-gas CO₂ permeance by 41%. These results underscore the critical role of permeation cell design and testing methods in accurately evaluating membrane performance, with significant implications for scaling up TFC membranes and optimizing industrial processes.

3D printing↗

Ammonium Looping with Membrane Absorber and Distributed Stripper for Enhanced Algae Growth

The objective of this project is to conduct a comprehensive investigation to develop and demonstrate a practical, reliable, and cost-effective integrated carbon dioxide (CO 2 ) capture and biofixation process for algae production. This process utilizes a chemical hindered ammonium solution (NH 4 OH) as both a capture reagent and an algae nutrient. The membrane absorber employed in the system ensured minimal ammonia (NH 3 ) emissions in the treated flue gas. Additionally, distributed solar-energy powered strippers located near the bioreactor modules facilitate solvent regeneration and enable just-in-time delivery of CO 2 and NH 3 to the algae, thereby minimizing the pH swing for enhanced productivity. The proposed membrane CO 2 absorber and solar-powered stripper is designed and seamlessly integrated with the existing 0.1 MWth bench-scale CO 2 capture system (CCS) and open raceway ponds (ORPs) at the University of Kentucky Center for Applied Energy (UK CAER) campus. The entire integrated process has undergone construction, operation, testing, and analysis. Furthermore, technology has been evaluated with a techno-economic analysis (TEA), technology gap analysis (TGA), life-cycle analysis (LCA), and a technology maturation plan (TMP). This project was performed within two budget periods, 54 months in duration. There are fourteen Project Tasks, twelve Milestones and four Success Criteria.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Innovation in Radiological Security, Part 2 of 2 – Insights into Developing a Cloud-hosted Security Technology

A Sentry Remote Monitoring System (Sentry-RMS) is a stand-alone security system that provides detection, assessment, and communication of priority alarms as an additional means of thwarting internal and external threats to sites that maintain radiological material. The SEntry-RMS CommUnications and REsponse (Sentry-SECURE) platform is an optional feature of the Sentry-RMS that relays priority alarm information to the identified response stakeholders. Sentry-SECURE is hosted in a cloud environment that abstracts the data owner’s and data consumer’s platforms to allow for greater information sharing. This promotes situational awareness amongst authorized users and enables future innovation among modern response platforms. When securely architecting a cloud solution such as this, the use of design paradigms can be an effective tool to increase the accuracy and reliability of cyber- and information-security-related decisions made throughout the development process. This approach also supports the categorization of design considerations into three levels: industry concepts, project approaches, and data protections for digital processes. Industry concepts consist of the notional underpinnings that guide or motivate a security process, system, or design but often lack any tangible attributes. Project approaches represent decisions made during the design and development process to prioritize a solution, method, or practice above another that may provide a comparable functional output but lacks a desired security benefit. Data protections for digital processes represent the selection, integration, and implementation of specific controls for a given asset. This paper will explore specific examples of how Sentry-SECURE has been designed to account for considerations at each of these three levels, while balancing the operational intent of the platform with the security enhancements necessary to maintain data integrity, availability, and confidentiality.

assessment, RMS, security, physical, cloud, Cyber ↗

Data-Informed Evaluation Framework for Integrated Energy Systems: Insights from Power, Process Heat, and Hydrogen Production Applications

The multi-criteria decision analysis (MCDA) framework provides a systematic evaluation of the diverse preferences and performance metrics associated with alternative solutions. This approach is advantageous over a single-criterion methodology, which are only valid under conditions that assume ceteris paribus or an "apples-to-apples" comparison. However, selecting suitable technologies for integrated energy systems (IES) can be likened to an "apples-to-oranges" comparison, given the heterogeneous factors at stake. These factors include economics and performance parameters, geological compatibility, and environmental impacts. Consequently, past research has often employed a mixture of qualitative and quantitative criteria tailored to the specific interests of each study. While the method proves effective in handling the intricate interplay of criteria, the resulting rankings and scores can vary from study to study. This inconsistency is introduced from the use of subjectively defined thresholds and weights. As a result, decision-makers frequently find it challenging to establish clear connections between specific criteria and the resulting scores, as the transformation of criteria into ordinal scores results in a substantial loss of information. To address this challenge, we introduce a data-informed IES evaluation framework that offers comprehensive, interpretable, and traceable evaluations backed by quantifiable rationale. First, we identified key IES evaluation criteria from a decade of literature, focusing on relevant IES applications in power, process heat, and hydrogen production. We leveraged state-of-the-art cost estimates from the Idaho National Laboratory (INL) and technical data from 78 reactor designs from the International Atomic Energy Agency (IAEA) and the Organization for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA). Lastly, we established thresholds by analyzing the mean, variance, root mean square, and slope of values across alternatives, categorizing the preferences of decision-makers into distinct utility functions, such as linear, saturating, exponential, and stepwise. Our approach yielded two main outcomes: (1) it provided consistent assessments across different stakeholder groups and (2) it visualized uncertainties in the decision-making context via comprehensive sensitivity analysis. To demonstrate the impact of our framework, we conducted case studies on 6 reactor designs (AP1000, NuScale, BWRX-300, Xe-100, eVinci, iMSR) for the three applications. Our data-driven framework proved to be highly effective in addressing heterogenous uncertainties faced by varied decision-makers? preferences and IES applications, as well as cost and technical estimates of advanced reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

Assessing high fidelity multi-component models to facilitate safeguards at Gas Centrifuge Enrichment Plants

We report that the International Atomic Energy Agency (IAEA) inspectors routinely carry out environmental sampling (ES) as a verification method. Collection of environmental swipe samples at various locations in Gas Centrifuge Enrichment Facilities (GCEPs) is an important process in detecting misuse of a declared facility and possibly the existence of undeclared nuclear material. These samples are measured for isotopic composition in uranium containing particles by Thermal Ionization Mass Spectrometry (TIMS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Even though ES is highly effective in detecting the absolute value of enrichments and their deviations from the declared values, it cannot explain the cause of those changes. Several potential explanations can serve as possibilities for particles detected above or other than the declared enrichment. These include normal and non-malicious events such as the design of the enrichment cascades, unintentional failures of the machines, or overshoot during startup of a cascade. It can also be the result of deliberate misuse by the facility operators. The primary objective of this work is to understand how these factors affect the enrichments produced by a cascade and quantify anticipated multi-isotopic concentrations for each case. The following methodology is employed to determine signatures at a particular facility. 1) Utilize a new two-dimensional multi-component diffusion code to obtain centrifuge performance data and use that information to design and perform cascade analysis. Compare and contrast the results with previous 1-D radially averaged solutions from the Pancake code. 2) Design a GCEP cascade with the production goal of 19.75% 235 U for each set of machine data above. Investigate two cascade scenarios that include enrichment of natural uranium (NU) feed to 19.75% 235U in a single cascade compared to a two-step process of NU to 5% and then 5% to 19.75%. 3) Simulate the intentional vs. unintentional off-normal scenarios in the cascades to assess the differences in isotopic concentrations. A non-ideal squared-off cascade model developed at the University of Virginia is used to calculate flow rates and isotopic concentrations of the process gas. The analysis is performed using the Rome machine model operated at 600 m/s rotor speed. The upper and lower bounds of normal and abnormal enrichments in a typical facility are used in conjunction with ES results to understand the root causes of such observations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Application of an Embedded Fracture and Borehole Modeling Approach to the Understanding of EGS Collab Experiment 1

EGS Collab is a series of meso-scale experiments and associated numerical simulation activities being funded by the United States Department of Energy, Geothermal Technologies Office (GTO) to investigate enhanced geothermal system processes under in-situ stress and slightly elevated temperature conditions. This project is designed to provide scientists and engineers with immediate access to impermeable rock at scales larger than possible in the laboratory, but generally smaller than those for commercial production. Immediate access to rock is provided via the existing drifts of the former Homestake Gold Mine, now operated as the Sanford Underground Research Facility in Lead, South Dakota. The objectives of the EGS Collab project are to develop well controlled fracture networks between injector and producer boreholes using normal and shear stimulation for permeability enhancement. The first experimental site was located off the West Access drift on the 4850 Level (4850 feet below ground surface) in phyllite of the Precambrian Poorman formation, and involved the creation of a fracture network comprising a combination of hydraulic and natural fractures. A second experimental site is now being considered near the battery alcove on the 4100 Level in amphibolite and rhyolite of the Yates Unit. Data generated during these experiments will be compared against predictions of a suite of computer codes specifically designed to solve problems involving coupled thermal, hydrological, geomechanical, and geochemical processes. Comparisons between experimental and numerical simulation results will provide code developers with direction for improvements and verification of process models, build confidence in the suite of available numerical tools, and ultimately identify critical future development needs for the geothermal modeling community. Moreover, conducting thorough comparisons of models, modelling approaches, measurement approaches and measured data, via the EGS Collab project, will serve to identify techniques that are most likely to succeed at the Frontier Observatory for Research in Geothermal Energy (FORGE), the GTO’s flagship EGS research effort. Experiment 1 has comprised a series of successful tests, including a long-term chilled-water circulation test, but the testbed has two atypical EGS elements. Active ventilation in the adjacent drift over a 50-year period cooled the testbed rock mass and hydraulic fracturing intersected monitoring boreholes making them conduits for fluid flow. Numerical simulations executed in support of the design of the EGS Collab Experiment 1, computed a radial temperature distribution and stress gradient orthogonal to the drift axis, resulting in the forecast of an oblong hydraulic fracture geometry, extended in the direction of the drift from the stimulation borehole. This paper describes the numerical simulation of long-term chilled-water circulation test with an embedded fracture and borehole modeling approach. The principal objective of the simulation work is show agreement between experimental observations in terms of production fluid temperatures, monitoring borehole temperatures, injection and production pressures, and tracer recoveries using a single conceptual model for the fracture network, using characterization and monitoring data generally available for EGS. A secondary objective is to improve the numerical simulation result comparisons with additional data available from the broader monitoring equipment within the testbed versus deeper, hotter, and more remote EGS. One complicating factor for comparisons between the numerical simulation results and experimental observations, is the Joule-Thomson heating associated with large pressure drops across the fracture network.

numerical simulation, embedded fractures and boreh↗

Severity factor kinetic model as a strategic parameter of hydrothermal processing (steam explosion and liquid hot water) for biomass fractionation under biorefinery concept

Hydrothermal processes are an attractive clean technology and cost-effective engineering platform for bio-refineries based in the conversion of biomass to biofuels and high-value bioproducts under the basis of sustainability and circular bioeconomy. The deep and detailed knowledge of the structural changes by the severity of biomasses hydrothermal fractionation is scientifically and technological needed in order to improve processes effectiveness, reactors designs, and industrial application of the multi-scale target compounds obtained by stream explosion and liquid hot water systems. The concept of the severity factor [log 10 (R 0 )] established > 30 years ago, continue to be a useful index that can provide a simple description of the relationship between the operational conditions for biomass fractionation in second generation of biorefineries. Furthermore, this review develops a deep explanation of the hydrothermal severity factor based in lignocellulosic biomass fractionation with emphasis in research advances, pretreatment operations and the applications of severity factor kinetic model.

09 BIOMASS FUELS↗

Design Assessment of Brayton Cycles for Combined Heat and Power from Nuclear Power Plants

Brayton cycles (BCs) are gaining renewed interest for use in high-temperature nuclear reactors for power production. This study explores the potential of nuclear Brayton systems in industrial combined heat and power (CHP) production. After a review of the historical deployment and technical development of BC systems for nuclear and cogeneration applications several BCs in CHP configurations are assessed when applied to representative high-temperature reactor types. The analysis emphasizes process heat delivery options, electrical efficiency, and component performance for the case of a direct cycle—Helium BC in a high temperature gas reactor, and an open-air Brayton cycle with a high temperature gas reactor. The results highlight thermodynamic trade-offs in cogeneration operation, particularly in recuperated configurations, and compare BC-based CHP with conventional Rankine cycle (RC) performance. Key findings suggest Helium BCs offer viable CHP performance primarily at lower process heat temperatures, with open air cycles being less efficient. The work also demonstrates trade-off between CHP performance and power production performance with a detailed comparison to where steam RC has better performance. The work is designed to be used as a reference work when cogeneration is proposed from high temperature reactors alongside the use of BCs.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Invite the Chaos Monkey: Test Effect Payloads for Tuning ICS Incident Response

In 2010, when Netflix moved their operational systems to the cloud, they developed a pseudo-random mechanism to cause deliberate outages and failures of key system elements to ensure that automated systems for detecting and remediating outages were mature and fully functional. This Chaos Monkey spawned an entire Simian Army designed to ensure system resilience and enable failure response before issues became outages. Through the DARPA RADICS program, Provatech, INL, and other researchers have developed a mechanism for creating controllable failures via Test Effect Payloads (TEPs) for Industrial Control Systems in order to enable an asset owner to tune network and process sensor technology, increase the effectiveness of incident response and remediation, and highlight areas where resilient technology could bring benefit to Operational Technology. This talk will explore what a TEP is, how to create a TEP, and suggest what a systematic system resilience plan using TEP’s might look like. We will also discuss how regulated entities might employ TEP’s in a compliant resilience strategy.

42 ENGINEERING↗

A Tandem Electrolysis Process for Multi-Carbon Chemical Production from Carbon Dioxide (Final Technical Report)

a two-step CO 2 electroreduction process for selective production of acetate and ethylene was successfully developed at the kW-scale. The CO 2 and CO electrolyzers were first investigated individually on the Watt-scale to achieve high current densities and more durable operation by using a reinforced GDL. High CO 2 conversion was obtained in the first CO 2 electrolyzer to produce a CO-dominant gas stream with minimal CO 2 , and highly pure acetate stream was produced in the second CO electrolyzer by using NiFe anode, which promoted alcohol oxidation to carboxylates. The two-step process operated stably for 200 h with acetate and ethylene as the major C 2+ products. Degradation mechanism study revealed that the flooding and the salt formation in the GDL is likely the biggest contributor to the performance degradation for both CO 2 and CO electrolyzers. A 1,000 cm 2 CO electrolyzer stack was then designed, fabricated, and operated up to a total current of 300 A along with a 500 cm 2 CO 2 electrolyzer stack which was operated up to a total current of 100 A. The CO electrolyzer stack demonstrated good stability at 300 A for at least 125 h at a carbon selectivity >96%. The impact of CO 2 , O 2 , N 2 , SO x , and NO x gas impurities on the CO electrolyzer stack was studied and a relatively high resistance to these contaminants was demonstrated. Electroreduction of CO 2 into acetic acid was also demonstrated to be environmentally favorable when compared to the traditional production of acetic acid when powered by renewable electricity. Additionally, electricity cost was identified as the primary source of cost sensitivity indicating substantial economic improvements could be achieved by continuing to drive down the cost of renewable electricity. Overall, the presented approach demonstrates the feasibility of the two-step electrochemical CO 2 reduction process for the effective production of C 2+ products at the kW-scale which should inspire future scaling efforts accelerating commercialization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear analog processing with anisotropic nonlinear films

Digital signal processing is the cornerstone of several modern-day technologies, yet in multiple applications it faces critical bottlenecks related to memory and speed constraints. Thanks to recent advances in metasurface design and fabrication, light-based analog computing has emerged as a viable option to partially replace or augment digital approaches. Several light-based analog computing functionalities have been demonstrated using patterned flat optical elements, with great opportunities for integration in compact nanophotonic systems. So far, however, the available operations have been restricted to the linear regime, limiting the impact of this technology to a compactification of Fourier optics systems. In this paper, we introduce nonlinear operations to the field of metasurface-based analog optical processing, demonstrating that nonlinear optical phenomena, combined with nonlocality in flat optics, can be leveraged to synthesize kernels beyond linear Fourier optics, paving the way to a broad range of new opportunities. As a practical demonstration, we report the experimental synthesis of a class of nonlinear operations that can be used to realize broadband, polarization-selective analog-domain edge detection.

analog image processing↗

Hillsborough County Clear Sky Assessment Process: Prioritizing Solar + Storage for Resilient Facilities & Communities

The Clear Sky Tampa Bay project was a 15-month collaborative research effort to support solar + storage deployment for community resilience in Florida. The Clear Sky Decision Support Toolkit is a collection of resources designed to support users in conducting solar + storage prioritization and feasibility screening assessments at critical facilities. The Tampa Bay Regional Planning Council worked with four local governments in the region to test and apply the Toolkit. This case study series describes how each partner government used the Toolkit and highlights key insights and lessons learned that other users could follow to replicate the process. Hillsborough County used the Clear Sky Decision Support Toolkit to analyze solar + storage as an additional resiliency feature at its Brandon Support Operation Complex (BSOC). During normal operations, the BSOC houses water utility administration services and workspaces for water and wastewater engineers, facilities maintenance, and environmental management staff. During emergency management activation, the BSOC serves as an emergency hub for Emergency Support Function 3 (ESF-3), which includes public utilities, public works, and engineering staff support members. The BSOC is designated as a critical facility by the County.

14 SOLAR ENERGY↗

Optimizing Ammonia Separation via Reactive Absorption for Sustainable Ammonia Synthesis

Metal halide salts such as magnesium chloride have been shown to be promising candidates for ammonia storage materials for energy storage and agriculture applications due to their ability to incorporate several moles of ammonia per mole of salt. Ammonia exiting a synthesis reactor can be separated from nitrogen and hydrogen by absorption into magnesium chloride. Such an absorption can be more complete and hotter than separation via ammonia condensation, the current standard in the Haber–Bosch process. Here, we discuss the optimal conditions for the cyclic uptake and release of ammonia from the supported magnesium chloride absorbents. An automated system was designed for measuring the nonequilibrium working capacity of the absorbent, as well as the impact of important operating conditions such as absorption and desorption temperature, pressure, and desorption time. Measurements of absorption and desorption kinetics provide insight into the mechanisms involved. The temperatures and pressures during absorption and desorption were designed to use minimal energy input to maximize the uptake and release of ammonia within a reasonable amount of time. In a laboratory-scale bed, absorption has a small unused bed length, so it is largely independent of mass transfer; it is dominated by how fast ammonia is fed to the bed. Yet, desorption is restricted both by the speed of heating the bed and by diffusion out of the absorbent. These measurements provide guidelines for ammonia separations and cycling sorbent materials on a larger scale.

10 SYNTHETIC FUELS↗

Synchronous micromechanically resonant programmable photonic circuits

Abstract Programmable photonic integrated circuits (PICs) are emerging as powerful tools for control of light, with applications in quantum information processing, optical range finding, and artificial intelligence. Low-power implementations of these PICs involve micromechanical structures driven capacitively or piezoelectrically but are often limited in modulation bandwidth by mechanical resonances and high operating voltages. Here we introduce a synchronous, micromechanically resonant design architecture for programmable PICs and a proof-of-principle 1×8 photonic switch using piezoelectric optical phase shifters. Our design purposefully exploits high-frequency mechanical resonances and optically broadband components for larger modulation responses on the order of the mechanical quality factor Q m while maintaining fast switching speeds. We experimentally show switching cycles of all 8 channels spaced by approximately 11 ns and operating at 4.6 dB average modulation enhancement. Future advances in micromechanical devices with high Q m , which can exceed 10000, should enable an improved series of low-voltage and high-speed programmable PICs.

42 ENGINEERING↗

Hybrid-RL-MPC4CLR (Hybird-Reinforcement-Learning-Model-Predictive-Control-for-Reserve-Policy-Assisted-Critical-Load-Restoration-in-Distribution-Grids)

Hybrid-RL-MPC4CLR was developed as a hybrid controller for active distribution grid critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. The RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while the MPC models grid operations incorporating the RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. The developers formulated the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The software is developed using various software packages in Python. The MPC's optimal power flow (OPF) model is implemented using the Pyomo package, the RL simulation environment is implemented using the MPC simulation with various scenarios of renewable energy and load demand profiles and power outage beginning times, based on the OpenAI Gym framework. The RL agent training is performed using the RLlib Ray package. The RL algorithm is trained offline using historical forecasts of renewable generation and load demand profiles. Simulation analysis and performance tests are conducted using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery.

Eseye, Abinet Tesfaye↗

Development of a Solar Heat and Power Co-Generation System. Final Report, CRADA No. TC02152.0

Final Report, CRADA No. TC02152.0. Date Technical Work Ended: October 28, 2013. This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Tassajara Technologies, Inc. (TTI), to develop, fabricate and demonstrate a Solar Heat and Power Co-generation System. The technical objectives of this CRADA were to engineer, design and build a prototype Solar Thermal Process Heat and Power Demonstration System that would be suitable for use at the Arc of Hilo food processing facility. This would be accomplished in two phases. The first phase would entail the building of a prototype at Tassajara facilities. Base design parameters, including the subsystem interactions that would produce reliable performance at the lowest cost per watt of energy generated with the desired balance of power and heat to meet the requirements of the designated food processing applications from Arc of Hilo, would be provided by LLNL. The data and design development would be integrated into the second phase engine prototype and solar thermal system that would be built and delivered, with interface requirements to the Miko Building. This project was originally designated as an eight (8) month project. However, it was ultimately extended by an additional thirty-five (35) months, for total project duration of forty-three (43) months.

14 SOLAR ENERGY↗

Development of a Solar Heat and Power Co-Generation System. Final CRADA Report

Final Report CRADA No. TC02152.0 Date Technical Work Ended: October 28, 2013. This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Tassajara Technologies, Inc. (TTI), to develop, fabricate and demonstrate a Solar Heat and Power Co-generation System. The technical objectives of this CRADA were to engineer, design and build a prototype Solar Thermal Process Heat and Power Demonstration System that would be suitable for use at the Arc of Hilo food processing facility. This would be accomplished in two phases. The first phase would entail the building of a prototype at Tassajara facilities. Base design parameters, including the subsystem interactions that would produce reliable performance at the lowest cost per watt of energy generated with the desired balance of power and heat to meet the requirements of the designated food processing applications from Arc of Hilo, would be provided by LLNL. The data and design development would be integrated into the second phase engine prototype and solar thermal system that would be built and delivered, with interface requirements to the Miko Building.

14 SOLAR ENERGY↗