Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portable Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biomedical Support of U.S. Extravehicular Activity

The world's first extravehicular activity (EVA) was performed by A. A. Leonov on March 18, 1965 during the Russian Voskhod-2 mission. The first US EVA was executed by Gemini IV astronaut Ed White on June 3, 1965, with an umbilical tether that included communications and an oxygen supply. A hand-held maneuvering unit (HHMU) also was used to test maneuverability during the brief EVA; however the somewhat stiff umbilical limited controlled movement. That constraint, plus difficulty returning through the vehicle hatch, highlighted the need for increased thermal control and improved EVA ergonomics. Clearly, requirements for a useful EVA were interrelated with the vehicle design. The early Gemini EVAs generated requirements for suits providing micro-meteor protection, adequate visual field and eye protection from solar visual and infrared radiation, gloves optimized for dexterity while pressurized, and thermal systems capable of protecting the astronaut while rejecting metabolic heat during high workloads. Subsequent Gemini EVAs built upon this early experience and included development of a portable environmental control and life support systems (ECLSS) and an astronaut maneuvering unit. The ECLSS provided a pressure vessel and controller with functional control over suit pressure, oxygen flow, carbon dioxide removal, humidity, and temperature control. Gemini EVA experience also identified the usefulness of underwater neutral buoyancy and altitude chamber task training, and the importance of developing reliable task timelines. Improved thermal management and carbon dioxide control also were required for high workload tasks. With the Apollo project, EVA activity was primarily on the lunar surface; and suit durability, integrated liquid cooling garments, and low suit operating pressures (3.75 pounds per square inch absolute [psia] or 25.8 kilopascal [kPa],) were required to facilitate longer EVAs with ambulation and significant physical workloads with average metabolic rates of 1000 BTU/hr and peaks of up to 2200 BTU/hr. Mobility was further augmented with the Lunar Roving Vehicle. The Apollo extravehicular mobility unit (EMU) was made up of over 15 components, ranging from a biomedical belt for capturing and transmitting biomedical data, urine and fecal containment systems, a liquid cooling garment, communications cap, a modular portable life support system (PLSS), a boot system, thermal overgloves, and a bubble helmet with eye protection. Apollo lunar astronauts performed successful EVAs on the lunar surface from a 5 psia (34.4 kPa) 100% oxygen environment in the Lunar Lander. A maximum of three EVAs were performed on any mission. For Skylab a modified A7LB suit, used for Apollo 15, was selected. The Skylab astronaut life support assembly (ALSA) provided umbilical support through the life support umbilical (LSU) and used open loop oxygen flow, rather than closed-loop as in Apollo missions. Thermal control was provided by liquid water circulated by spacecraft pumps and electrical power also was provided from the spacecraft via the umbilical. The cabin atmosphere of 5 psia (34.4 kPa), 70% oxygen, provided a normoxic atmosphere and because of the very low nitrogen partial pressures, no special protocols were required to protect against decompression sickness (DCS) as was the case with the Apollo spacecraft with a 5 psi, 100% oxygen environment.

Gernhardt, Michael L.↗

Energy storage: The future enabled by nanomaterials

Lithium-ion batteries, which power portable electronics, electric vehicles, and stationary storage, have been recognized with the 2019 Nobel Prize in chemistry. The development of nanomaterials and their related processing into electrodes and devices can improve the performance and/or development of the existing energy storage systems. We provide a perspective on recent progress in the application of nanomaterials in energy storage devices, such as supercapacitors and batteries. The versatility of nanomaterials can lead to power sources for portable, flexible, foldable, and distributable electronics; electric transportation; and grid-scale storage, as well as integration in living environments and biomedical systems. To overcome limitations of nanomaterials related to high reactivity and chemical instability caused by their high surface area, nanoparticles with different functionalities should be combined in smart architectures on nano- and microscales. The integration of nanomaterials into functional architectures and devices requires the development of advanced manufacturing approaches. We discuss successful strategies and outline a roadmap for the exploitation of nanomaterials for enabling future energy storage applications, such as powering distributed sensor networks and flexible and wearable electronics.

catalysis (heterogeneous)↗

I. Final Report for DOE SBIR Phase I Project DE-SC0013795 Final Report for DOE SBIR Phase I Project DE-SC0013795 Microtron-based Compact, Portable Gamma-Ray Source

Microtron-based Compact, Portable Gamma-Ray Source. The objective of Phase I of this project was to produce a conceptual design of a prototype compact microtron electron accelerator, which could be designed, built, and demonstrated in Phase II of the project. The conceptual design study included an analysis of the parameters of the microtron and its components, and the expected performance of the prototype microtron as a source of x-rays and/or RF neutrons in the MeV energy range. The major components of the microtron are the magnet, the accelerating system, the power system, the vacuum system, the control system, the beam extraction system and the targets to produce x-rays (and/or neutrons). Our objectives for the design of the prototype were for it to be compact, cost-effective, capable of producing high intensity x-ray (an/or neutron) fluxes. In addition, the prototype was to be easily assembled and disassembled so that components could be easily replaced. The main parameters for the prototype are the following: the range of electron kinetic energies, the output power, the RF frequency band (X-band, C-band, or S-Band), the type of injection (Type I or Type II), the magnet type, i.e. permanent magnet, electromagnet, or a hybrid combination of permanent and electromagnet. The results of the Phase I study and analysis for a prototype microtron are the following: The electron energy range can be varied from below 6 MeV to 9 MeV, the optimal frequency range is S-Band (2-4 GHz) RF frequency, Type II injection (described below), and the magnet type is the hybrid version. The prototype version will be capable of producing gamma ray doses of ~1800 R/min-m and neutron fluxes of up to ~6 x 10 10 n/s with appropriate targets. The results of the Phase I study and analysis are provided below. The proposed Phase II plan was to demonstrate the prototype at low beam power. In the subsequent Phase III, high power tests would be performed, and the design of commercial versions of microtrons with various energies, sizes and types would be produced and marketed, including a more compact and more portable 6 MeV battery-powered model that more closely meets the requirements in the original FOA topic description. In the course of the Phase I study, we also identified another microtron version, one that was larger (not compact) and more powerful than that of the Phase II prototype, which could serve as an intense source of photo- neutrons, up to 4 x 10 12 n/s for use in nuclear medicine, short-lived isotope production, or other applications. In addition, it could produce gamma dose rates up to 130 kR/min-m with a heavy metal bremsstrahlung target. The results and specifications of this were submitted to IPAC16 (Reference [12]) the paper is included in Addendum B. Because this version was beyond the scope of the Phase I project, there is no additional description in the Final Report.

43 PARTICLE ACCELERATORS↗

The role of coverage effects on the structure–sensitivity of formic acid electrooxidation on Pd surfaces

Direct formic acid (FA) fuel cells (DFAFCs) with Pd anode catalysts are promising for small portable applications. During the electrooxidation of formic acid (FAO), CO accumulates on the Pd electrocatalyst, thereby decreasing its performance. In this work, we use density functional theory (DFT; RPBE) to elucidate the significance of coverage effects on the structure–sensitivity of FAO over four low–index Pd surfaces: Pd(1 1 1), Pd(1 0 0), Pd(1 1 0), and Pd(2 1 1). We construct coverage–dependent Gibbs free energy diagrams and in agreement with experiment, predict that Pd(1 0 0) and Pd(2 1 1) are the most active surfaces. Additionally, we find that the presence of CO spectator species can alter the preferred electrooxidation pathway under different applied potentials. Furthermore, such pathway transitions appear to be critical for rationalizing experimental trends regarding electrocatalytic activity and are only captured when coverage effects are accounted for. Insights derived from this work may facilitate the design of improved FAO electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental system for the control of surgically induced infections

The development tests to be performed on the experimental system are described in detail. The test equipment, conditions, and procedures are given. The portable clean room tests include assembly, collapsability, portability, and storage; laminar flow rate; static pressure; air flow pattern; and electrostatic buildup. The other tests are on the ventilation system, human factors evaluation, electrical subsystem, and material compatibility.

Tevebaugh, M. D.↗

Optical tools and techniques for aligning solar payloads with the SPARCS control system

The success of a rocket-borne experiment depends not only on the pointing of the attitude control system, but on the alignment of the attitude control system to the payload. To ensure proper alignment, special optical tools and alignment techniques are required. Those that were used in the SPARCS program are described and discussed herein. These tools include theodolites, autocollimators, a 38-cm diameter solar simulator, a high-performance 1-m heliostat to provide a stable solar source during the integration of the rocket payload, a portable 75-cm sun tracker for use at the launch site, and an innovation called the Solar Alignment Prism. Using the real sun as the primary reference under field conditions, the Solar Alignment Prism facilitates the coalignment of the attitude sun sensor with the payload. The alignment techniques were developed to ensure the precise alignment of the solar payloads to the SPARCS attitude sensors during payload integration and to verify the required alignment under field conditions just prior to launch.

Thomas, N. L.↗

A new model for yaw attitude of Global Positioning System satellites

Proper modeling of the Global Positioning System (GPS) satellite yaw attitude is important in high-precision applications. A new model for the GPS satellite yaw attitude is introduced that constitutes a significant improvement over the previously available model in terms of efficiency, flexibility, and portability. The model is described in detail, and implementation issues, including the proper estimation strategy, are addressed. The performance of the new model is analyzed, and an error budget is presented. This is the first self-contained description of the GPS yaw attitude model.

Bar-Sever, Y. E.↗

A system for low field imaging of laser-polarized noble gas

We describe a device for performing MRI with laser-polarized noble gas at low magnetic fields (<50 G). The system is robust, portable, inexpensive, and provides gas-phase imaging resolution comparable to that of high field clinical instruments. At 20.6 G, we have imaged laser-polarized (3)He (Larmor frequency of 67 kHz) in both sealed glass cells and excised rat lungs, using approximately 0.1 G/cm gradients to achieve approximately 1 mm(2) resolution. In addition, we measured (3)He T(2)(*) times greater than 100 ms in excised rat lungs, which is roughly 20 times longer than typical values observed at high ( approximately 2 T) fields. We include a discussion of the practical considerations for working at low magnetic fields and conclude with evidence of radiation damping in this system. Copyright 1999 Academic Press.

NASA Program Biomedical Research and Countermeasur↗

Performance Versus Maintainability: A Case Study of Scream on Frontier

The Simple Cloud-Resolving E3SM Atmosphere Model (Scream) won the inaugural ACM Gordon Bell Prize for Climate Modeling. While most of Scream is portable Kokkos code, the Gordon-Bell runs did include tuning specifically for Frontier, the exascale computer at Oak Ridge National Laboratory. Production science runs use the same high-level configuration of Scream, but the tuned kernels do not meet the software standards necessary to merge into the production code base. This work describes experiments to refactor these kernels to meet the maintainability requirements of the production Scream code base while preserving high performance.

White, Trey↗

Efficient, Portable Radioxenon Collection for Nuclear Test Monitoring

Detection of radioxenon in the atmosphere is considered the most specific method to determine whether a nuclear test has occurred. It is therefore an important component of the Comprehensive Test Ban Treaty (CTBT) verification regime. Radioxenon collection is primarily performed by means of a network of remote monitoring stations at fixed locations around the world. This arrangement is effective but often limited in terms of the response time and sensitivity, two factors that could be improved if radioxenon collection devices were portable. By employing recent advancements in porous materials and adsorption technologies, it is possible to overcome some of the limitations of current radioxenon collection systems. This work established the initial modeling and scoping study towards developing an efficient and portable radioxenon collection system for nuclear test monitoring.

36 MATERIALS SCIENCE↗

Use of the Manuela 3D/Radiation Scanning Tool at Nuclear Facilities - 20437

Licensees, facility operators and decommissioning contractors have a need for comprehensive, accurate and precise radiological and topographical data to plan and execute safe and efficient Decontamination and Decommissioning (D and D) projects. Traditional approaches rely greatly upon labor and administratively intensive data collection methods that require considerable time and effort to glean the relevant data to plan and perform work in a radiological work area. Orano Decommissioning Services has developed and utilized at French nuclear facilities a lightweight portable scanning instrument called MANUELA (Mobile Apparatus for Nuclear Expertise Localization Assistance). Recently Orano conducted demonstrations at two United States nuclear facilities using MANUELA that may prove useful in areas of the fuel cycle including: - ALARA (As Low As Reasonably Achievable) planning during facility operations; - Scoping and site characterization during the D and D planning phase; - Remedial action support during active decommissioning work; - Radiation and modeling planning for plant modifications; - Support Final Status Survey and demonstration of 'end state' compliance for license termination. MANUELA is currently being evaluated for use during decommissioning of nuclear facilities and could aide in demonstrating compliance with end state criteria after decommissioning. Of particular interest are decommissioning projects planned for various sites across the United States. Most of these sites present unique challenges and opportunities to safely and efficiently decommission in a regulatory compliant manner. The two demonstration site's current conditions of relatively low radiation levels inside containment proved to be ideal platforms to deploy the MANUELA instrument for evaluation of the complex geometries typically found in a nuclear facility. The MANUELA instrument was able to precisely identify local hot spots of the reactor system's primary equipment and was able to simultaneously overlay the dose information onto the scanned 3D images. Using data like this, a licensee would be able to make informed technical and personnel decisions on methods to remediate, shield or properly dispose of the radioactive source term. MANUELA can be used throughout the decommissioning process to validate progress and continue to refine the work activities to optimize the efforts of the crew which reduces downtime waiting for survey results, whereas traditional survey methodology relies on a physical survey to be performed and the data transcribed onto survey maps that are only two dimensional. The traditional format tends to be inaccurate and difficult to interpret the precise location(s) of hot spots or generalized dose rates. The resultant scan also allows the user to know the exact extent of the survey versus transposing information onto a map with only a portion of the map area scanned. MANUELA also compiles all of the relevant survey data into a downloadable table format which includes the measurement identification number, time stamp, point space location on the XYZ plane, and the dose rate value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Expanding the genetic toolset: using serine recombinases to integrate riboregulatory elements into industrially relevant microbial chassis

To realize the full potential of biomanufacturing, the breadth of industrial microbes used to consume diverse feedstock and generate bioproducts needs to expand. As such, portable tools are required that can be used by multiple hosts for straightforward genomic manipulation and precise gene expression. Here, we demonstrate the co-utilization of two synthetic biology tools to achieve these goals: cis-repressors (CRs) and serine recombinase-assisted genome engineering (SAGE). CRs are small, noncoding RNAs that are placed upstream of the target gene to modulate bacterial translation rates at varying, discrete levels. SAGE uses site-specific serine recombinases to catalyze highly efficient, unidirectional insertion of DNA into the chromosome of diverse organisms. We used SAGE to integrate a suite of CRs into the industrially relevant hosts Pseudomonas putida, Corynebacterium glutamicum, and Cupriavidus necator. Using a fluorescent reporter as a readout of CR functionality, we found that CR performance across these backgrounds was similar—providing a range of translational repression up to 100-fold. Overall, these results demonstrate the high portability of CRs across bacterial genetic backgrounds, which ideally can be used in future microbial engineering efforts pertinent to biomanufacturing.

59 BASIC BIOLOGICAL SCIENCES↗

Air Monitoring for Hazardous Gas Detection

The Hazardous Gas Detection Lab is involved in the design and development of instrumentation that can detect and quantify various hazardous gases. Traditionally these systems are designed for leak detection of the cryogenic gases used for the propulsion of the Shuttle and other vehicles. Mass spectrometers are the basis of these systems, which provide excellent quantitation, sensitivity, selectivity, response and limits of detection. Unfortunately, these systems are large, heavy and expensive. This feature limits the ability to perform gas analysis in certain applications. Smaller and lighter mass spectrometer systems could be used in many more applications primarily due to the portability of the system. Such applications would include air analysis in confined spaces, in-situ environmental analysis and emergency response. In general, system cost is lowered as size is reduced. With a low cost air analysis system, several systems could be utilized for monitoring large areas. These networked systems could be deployed at job-sites for worker safety, throughout a community for pollution warnings, or dispersed in a battlefield for early warning of chemical or biological threats. Presented will be information on the first prototype of this type of system. Included will be field trial data, with this prototype performing air analysis autonomously from an aircraft.

Arkin, C. Richard↗

Portable computing - A fielded interactive scientific application in a small off-the-shelf package

Experience with the design and implementation of a portable computing system for STS crew-conducted science is discussed. Principal-Investigator-in-a-Box (PI) will help the SLS-2 astronauts perform vestibular (human orientation system) experiments in flight. PI is an interactive system that provides data acquisition and analysis, experiment step rescheduling, and various other forms of reasoning to astronaut users. The hardware architecture of PI consists of a computer and an analog interface box. 'Off-the-shelf' equipment is employed in the system wherever possible in an effort to use widely available tools and then to add custom functionality and application codes to them. Other projects which can help prospective teams to learn more about portable computing in space are also discussed.

Groleau, Nicolas↗

P4: Portable Parallel Processing Pipelines for Interactive Information Visualization

We present P4, an information visualization toolkit that combines declarative design specification and GPU computing for building high-performance interactive systems. Most of the existing information visualization toolkits do not harness the power of parallel processors in today's mainstream computers. P4 leverages GPU computing to accelerate both data processing and visualization rendering for interactive visualization applications. P4's programming interface offers a declarative visualization grammar for rapid specifications of data transformations, visual encodings, and interactions. By simplifying the development of GPU-accelerated visualization systems while supporting a high degree of flexibility and customization for design specification, P4 narrows the gap between expressiveness and scalability in information visualization toolkits. Through a range of examples and benchmark tests, we demonstrate that P4 provides high efficiency for creating interactive visualizations and offers drastic performance improvement over current state-of-the-art toolkits.

97 MATHEMATICS AND COMPUTING↗

Machine learning assisted modeling of mixing timescale for LES/PDF of high-Karlovitz turbulent premixed combustion

Accurate modeling of mixing in the transported probability density function (PDF) method remains a great challenge, especially for turbulent premixed combustion under extreme conditions such as high Karlovitz number Ka. Recently, a power-law based mixing timescale model was developed for the large-eddy simulations (LES)/PDF modeling of high-Ka number turbulent premixed flames. It is found in this work that the power-law mixing timescale model is highly sensitive to the model parameters. It is thus critically needed to develop accurate calibration of these model parameters. The empirical specification of the model parameters developed in Zhang et. al. is found to be inadequate for accurate modeling of the mixing timescale. Here, machine learning is introduced as an attractive alternative in this work for the specification of the model parameters. A high-Ka number DNS jet flame is used as the training and validation of the machine learning models. The choices of the input parameters are discussed and compared for the machine learning models. The effect of differential molecular diffusion on mixing is examined by including the effect of the Lewis number in the training of the machine learning models. The performance of different machine learning algorithms is compared for the specification of the mixing model parameters. Overall, excellent performance of the machine learning models is observed for assisting the mixing modeling. The feasibility, interpretability, applicability, generality, and portability of using machine learning are discussed in general to provide a perspective on applying data-driven machine learning for turbulent combustion modeling studies.

42 ENGINEERING↗