Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Chandra X-Ray Observations of the Spiral Galaxy M81

A Chandra X-Ray Observatory ACIS-S imaging observation is used to study the population of X-ray sources in the nearby Sab galaxy M81 (NGC 3031). A total of 177 sources are detected with 124 located within the D(sub 25) isophote to a limiting X-ray luminosity of approx. 3 x 10(exp 36) ergs/s. Source positions, count rates, luminosities in the 0.3-8.0 keV band, limiting optical magnitudes, and potential counterpart identifications are tabulated. Spectral and timing analysis of the 36 brightest sources are reported including the low luminosity active galactic nucleus, SN 1993J, and the Einstein-discovered ultraluminous X-ray source X6. The nucleus accounts for approx. 86%, or 5 x 10(exp 40) ergs/s, of the total X-ray emission from M81. Its spectrum is well fitted by an absorbed power law with photon index 1.98 +/- 0.08, consistent with previous observations (average index 1.9). SN 1993J has softened and faded since its discovery. At an age of 2594 days, SN 1993J displayed a complex thermal spectrum from a reverse shock rich in Fe L and highly ionized Mg, Si, and S but lacking O. A hard X-ray component, emitted by a forward shock, is also present. X6 is spatially coincident with a stellar object with optical brightness and colors consistent with an O9-B1 main-sequence star. It is also coincident with a weak radio source with a flux density of approx. 95 microJy at lambda = 3.6 cm. The continuum-dominated X-ray spectrum of X6 is most closely reproduced by a blackbody disk model suggesting the X-ray source is an approx. 18 solar mass object accreting at nearly its Eddington limit.

Swartz, Douglas A.↗

The Earth Occultation Technique with the Burst and Transient Source Experiment

The Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (CGRO) is an uncollimated all-sky instrument sensitive to photons in the 20 keV to 1 MeV range. Since CGRO orbits the Earth at an altitude of 450 km, about 33% of the sky, as viewed with BATSE, is covered by the Earth at any given time. The entire sky is subject to Earth Occultation for some portion of CGRO's 52 day precession period. When a source sets below (or rises above) the Earth's limb, atmospheric attenuation produces step-like features in the BATSE data. The observed change in count rate in several energy bands provides a measurement of the source intensity and spectrum without sophisticated background models. These occultation features are used to locate and monitor astrophysical sources with BATSE when the source signal can be separated from the detector background. Examples of step searches, spectra light curves, and transform imaging are presented. Systematic uncertainties due to source confusion, detector response, and rapid background variations are discussed.

Wilson, C. A.↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Earth Occultation Technique with the Burst and Transient Source Experiment

The Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (CGRO) is successfully being used as an all-sky hard X-ray monitor. The experiment consists of a set of eight uncollimated detectors sensitive to photons in the 20 keV to 2 MeV range. Since CGRO orbits the Earth at an altitude of about 450 km, about 33% of the sky, as viewed with BATSE, is covered by the Earth at any given time. The entire sky is subject to Earth occultation for some portion of CGRO's 52 day precession period. When a source sets below or rises above the Earth's limb, atmospheric attenuation produces step-like features in the BATSE data. The observed change in count rate in several energy bands provides a measurement of the source intensity and spectrum without sophisticated background models. These occultation features are used to locate and monitor astrophysical sources with BATSE when the source signal can be separated from the detector background. Examples of step searches, spectra, light curves, and transform imaging are presented.

Wilson, C. A.↗

Ultrashort Pulse Laser Surface Processing Techniques for Sterilization of Metal Surfaces for Planetary Protection

To prevent forward contamination from microbes aboard spacecraft intended to search for extraterrestrial life, there is a need for effective sterilization methods. However, current techniques are both time-consuming and expensive. For example, dry heat sterilization requires removal from the assembly site and several days of treatment. Furthermore, some components such as optics and electronics are not compatible with current sterilization techniques. Here, we report the latest results in our development of a novel femtosecond laser processing technique for the rapid sterilization of spacecraft hardware. Femtosecond lasers produce extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. Aluminum coupons were inoculated with specific densities of Bacillus subtilis bacterial endospores. These coupons were treated with various laser illumination parameters. Afterward, metal coupon samples were assayed for viable spores using a polyvinyl alcohol (PVA) peel, serial dilution, and plating for colony-forming units (CFU). Results indicate that with high enough energy density and pulse counts, most bacterial spores are inactivated with minimal damage to the metal. The sterilization is dependent on both the fluence and pulse count. In addition, femtosecond pulses are more effective than longer pulses for inactivation. These experiments have consistently achieved 4-log reduction in viable spores. Sterilization has been achieved on both flat metal coupons and non-flat surfaces with microchannels, with a slight reduction in sterilization efficiency on the uneven surface. The application of air flow during laser processing was also investigated as a way to remove spores that are dislodged from the surface by the laser illumination, which would contribute to the reduction of spacecraft bioburden. With laser processing technology rapidly evolving, our results support the possibility of an extremely rapid, in-situ surface sterilization method for use in spacecraft assembly clean rooms.

Kaleb McQuillan↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A mercuric iodide detector system for X-ray astronomy. I - Design considerations and predictions of background and sensitivity

Since the discovery of Sco X-1 initiated X-ray astronomy in 1962, this science has progressed in connection with the placement of X-ray photon detectors above the atmosphere by means of rockets, balloons, and satellites. In the last few years, studies have been conducted regarding the use of mercuric iodide (HgI2) as room temperature X-ray detector for applications in hard X-ray astronomy. These detectors combine a high quantum efficiency with good energy resolution. The sensitivity of an astronomical X-ray telescope is discussed, and a description is presented of a specific design accepted for the HDXT to be flown on Spacelab. Attention is given to predictions of the background counting rate of the detector assembly in this design, taking into account the results of a Monte Carlo simulation of the detector assembly in the radiation environment at balloon altitudes (40 km).

Ricker, G. R.↗

NuSTAR J163433-4738.7: A Fast X-Ray Transient in the Galactic Plane

During hard X-ray observations of the Norma spiral arm region by the Nuclear Spectroscopic Telescope Array (NuSTAR) in 2013 February, a new transient source, NuSTAR J163433-4738.7, was detected at a significance level of 8sigma in the 3-10 keV bandpass. The source is consistent with having a constant NuSTAR count rate over a period of 40 ks and is also detected simultaneously by Swift at lower significance. The source is not significantly detected by NuSTAR, Swift, or Chandra in the days before or weeks after the discovery of the transient, indicating that the strong X-ray activity lasted between approx. 0.5 and 1.5 days. Near-infrared imaging observations were carried out before and after the X-ray activity, but we are not able to identify the counterpart. The combined NuSTAR and Swift energy spectrum is consistent with a power law with a photon index of Gamma = 4.1(+1.5/−1.0) (90% confidence errors), a blackbody with kT = 1.2+/-0.3 keV, or a Bremsstrahlung model with kT = 3.0(+2.1/−1.2) keV. The reduced-χ2 values for the three models are not significantly different, ranging from 1.23 to 1.44 for 8 degrees of freedom. The spectrum is strongly absorbed with NH = (2.8(+2.3/−1.4) × 10(exp23) cm(exp−2), (9(+15 /−7) ) × 10(exp22) cm(exp−2), and (1.7(+1.7/−0.9)) × 10(exp23) cm(exp−2), for the power-law, blackbody, and Bremsstrahlung models, respectively. Although the high column density could be due to material local to the source, it is consistent with absorption from interstellar material along the line of sight at a distance of 11 kpc, which would indicate an X-ray luminosity greater than 10(exp34) erg s(exp−1). Although we do not reach a definitive determination of the nature of NuSTAR J163433-4738.7, we suggest that it may be an unusually bright active binary or a magnetar.

Near-infrared imaging observations↗

A photon-phreak digs the LDEF happening

Radioactivities of the LDEF onboard experiments induced by gamma emitting rays in both intentional samples and spacecraft parts were examined. The long time greatly enhanced the ability to detect some of the longer lived nuclides, including: 2.6 yr Na-22 in Al and Fe; 5.3 yr Co-60 in Co, Ni, and In; 2.9 yr Rh-102 in In; and 38 yr Bi-207 in Pb. These radionuclides, along with such other as 33 yr Ar-42 in Ti, Fe, or Ni and 47 yr Ti-44 in the same elements, would be appropriate monitors of the high energy space radiation field on long round-trip voyages in the solar system. Additional candidate radionuclides are also discussed. Radiometric analysis of the LDEF samples was a substantial effort among a dedicated group of experts in low level counting, and highlights several important aspects of the procedures needed to achieve success in this kind of endeavor. Target elements should be chosen to differentiate between neutron and proton induced reactions, whenever this is feasible. Reactions should be chosen with a wide range of energy thresholds, to enable calculation of both intensity and energy spectra of the particle fluxes.

Smith, Alan R.↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Second Look at 12 Candidate Dual AGNs Using BAYMAX

We present an analysis of 12 optically selected dual active galactic nucleus (AGN) candidates at z < 0.34. Each candidate was originally identified via double-peaked [O III] λ5007 emission lines and received follow-up Chandra and Hubble Space Telescope (HST) observations. Because the X-ray data are low-count (<100 counts) with small separations (<1''), a robust analysis is necessary for classifying each source. Pairing long-slit [O III] observations with existing Chandra observations, we re-analyze the X-ray observations with Bayesian AnalYsis of AGNs in X-rays to determine whether the X-ray emission from each system is more likely a single or dual point source. We find that 4 of the 12 sources are likely dual X-ray point-source systems. We examine each point source's spectra via a Monte Carlo method that probabilistically identifies the likely origin of each photon. When doing so, we find that (i) the secondary X-ray point sources in two of the systems have L(X)< 10(exp 40) erg/s, such that we cannot rule out a non-AGN origin, (ii) one source has a secondary with L(X)> 10(exp 40) erg/s but a spectrum that is too soft to definitively preclude being X-ray emitting diffuse gas that was photoionized by the primary AGN, and (iii) one system (SDSS J1126+2944) is a dual AGN. Additionally, using complementary HST observations, we analyze a subsample of systems that are visually identified as merging. Our results suggest that dual AGNs may preferentially reside in mergers with small separations, consistent with both simulations and observations.

Adi Foord↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Pulse shape discrimination technique for diffuse supernova neutrino background search with JUNO

Pulse shape discrimination (PSD) is widely used in particle and nuclear physics. Specifically in liquid scintillator detectors, PSD facilitates the classification of different particle types based on their energy deposition patterns. This technique is particularly valuable for studies of the diffuse supernova neutrino background (DSNB), nucleon decay, and dark matter searches. This paper presents a detailed investigation of the PSD technique, applied in the DSNB search performed with the Jiangmen Underground Neutrino Observatory (JUNO). Instead of using conventional cut-and-count methods, we employ methods based on boosted decision trees and neural networks and compare their capability to distinguish the DSNB signals from the atmospheric neutrino neutral-current background events. The two methods demonstrate comparable performance, resulting in a 50–80% improvement in signal efficiency compared to a previous study performed for JUNO (An et al. [JUNO] in J Phys G 43(3):030401, 2016). Moreover, we study the dependence of the PSD performance on the visible energy and final state composition of the events and find a significant dependence on the presence/absence of 11 C. Finally, we evaluate the impact of the detector effects (photon propagation, PMT dark noise, and waveform reconstruction) on the PSD performance.

FOS: Physical sciences↗

Ultrashort Pulsed Laser Treatment: A Novel Sterilization Method for Planetary Protection

Introduction: On missions seeking signs of potential life elsewhere in the solar system, we have an obligation not to bring our own Earthly life with us. Reducing the bioburden (number of living microbes) on spacecraft is therefore required by the COSPAR Policy on Planetary Protection to target bodies that are of interest for understanding the origins of life (such as Mars). The method of spacecraft sterilization predominantly used by NASA is Heat Microbial Reduction, which is typically incompatible with heat-sensitive components such as optics and electronics, and is expensive and time-consuming. Here, we present preliminary results on a novel method for spacecraft hardware sterilization: high-intensity ultrashort (femtosecond) pulsed laser illumination. Femtosecond lasers use extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. This rapid sterilization technique could be carried out in situ in a spacecraft assembly clean room using high-speed surface scanning, saving critical time and resources. It also can potentially remove or reduce debris from inactivated cells and spores. Methods: To develop optimal laser processing parameters for inactivating planetary protection-relevant organisms on metal surfaces, we inoculated 1-cm^2 mirror-polished aluminum coupons with Bacillus subtilis spores (2x10^5 spores/coupon) and tested the effect of several parameters, including pulse count and fluence. Sterilization effectiveness was measured by recovering spores using a PVA (polyvinyl acetate) peel and conducting serial dilution and plating for colony-forming units (CFUs). Results: Our results show that pulse count and fluence both affect sterilization effectiveness and that within a certain pulse count range, increasing fluence increases effectiveness. We have demonstrated the ability to reduce viable microbial counts by at least 10^-4. Future work will include testing higher abundances and different species of microorganisms, effectiveness on complex surfaces, compatibility with sensitive surfaces, and quantification of cell debris removal. Femtosecond pulsed laser illumination has the potential to provide dramatic savings in both cost and schedule over current methods of bioburden reduction to prevent forward contamination. It may also have the potential for use in surface sterilization of returned samples to prevent back contamination.

Planetary Protection; Lasers; Sterilization; Bacil↗

Faint X-ray source counts and the origin of the X-ray background

A thorough reanalysis of the Einstein Observatory Deep Survey data is presented in order to determine the contribution of detected, discrete sources of X-ray emission to the cosmic X-ray background. Substantial discrepancies with previously published work on this problem are found. A detailed discussion of data editing and source algorithms buttresses a claim of having constructed a complete, flux-limited sample of the faintest sources detectable with the Einstein imaging proportional counter, the most sensitive X-ray instrument yet flown. A total of 33 sources is found in a survey region of about 3.3 sq deg down to a minimum flux threshold of 4 x 10 to the 14th ergs/sq cm/s in the 0.3-3.5 keV band. Roughly 30 percent of the objects are foreground stars, leading to an extragalactic source surface density of 70,000/sr at this threshold. The integrated contribution from discrete sources to the number of cosmic X-ray background photons measured in this same band with the same instrument is 12 percent + or - 3 percent, substantially below previous estimates. Implications of these results for the origin of the background are discussed.

Hamilton, T. T.↗

New developments in structure-property and amorphous materials research at the upgraded 16-BM-B Paris-Edinburgh press station at HPCAT

Beamline 16-BM-B of the High-Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source (APS) provides a Paris-Edinburgh press program to probe the structure and properties of crystalline and amorphous materials up to 12 GPa at room temperature or 7 GPa at 2000°C. During the recent APS upgrade, 16-BM-B undertook major improvements to its instrumentation and measurement techniques. The upgrade includes the addition of a 1.2 m horizontal “condenser” mirror and a new variable-sized collimation system, the combination of which decreases the acquisition time for energy dispersive X-ray diffraction measurements by a factor of 10 when compared to pre-upgrade measurements. The addition of a new Ge energy-sensitive detector and DANTE (XGLab) digital pulse processor allows for processing the increased diffraction counts with minimal deadtime. In addition to upgraded beamline components, new techniques are being developed for eventual release to the user community, including electrical resistivity and tomography measurements.

APS upgrade↗

Development of High-QE GaN Photodectors for Liquid Noble Particle Detectors

Detection of the handful of photons generated when a dark matter particle interacts in a liquid Xenon detector requires a new type of photodetector with very high detection efficiency at ultraviolet wavelengths, very low radioactive backgrounds, and essentially no measureable readout noise (achieved with devices with high intrisic gain). Such devices would find wide applicability to not only high energy physics experiments, but to a number of commercial applications including, e.g., biomedical imaging of fluorescent tags. We developed photodetectors based on amorphous GaN thin film structures (photocathodes) grown by molecular beam epitaxy on quartz windows. We also developed approaches to integrate these photocathode device structures with vacuum electron multipliers. All materials and fabrication techniques were developed to minimize radioactive backgrounds in materials, so these detectors could be used for very low count rate experiments, such as the future liquid-Xenon dark matter detectors, and future liquid-Argon neutrino detectors. We demonstrated growth of very high quantum efficiency amorphous GaN cathodes grown on a number of different substrates (Stainless steel, p-Silicon) reaching detection efficiencies of 80% at 220nm. The key to this growth was to use nitrogen plasma-assistend MBEs and very low growth temperatures. We also discovered that thinner structures (e.g.,40nm a-GaN thin films) had the best performance. We successfully demonstrated techniques for the vacuum transfer of these photocathode structures to a novel chamber that used hydraulics and bellow to form a cold indium bond needed to integrate these cathodes into sealed-tube devices. A complete, stand-along, device could not be completed during this proposal period due to difficulties in growing structures on the thick quartz window. Subsequent work is aimed at addressing this difficulty, by growing a buffer layer on the quartz substrate.

07 ISOTOPE AND RADIATION SOURCES↗

An Overview of High-Resolution, Non-Dispersive, Imaging Spectrometers for High-Energy Photons

High-resolution x-ray spectroscopy has become a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites initiated a new era in x-ray astronomy. Despite their successes, there is still need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band and for extended sources. What is needed is a non-dispersive imaging spectrometer - essentially a 14-bit x-ray color camera. And a requirement for a nondispersive spectrometer designed to provide eV-scale spectral resolution is a temperature below 0.1 K. The required spectral resolution and the constraints of thermodynamics and engineering dictate the temperature regime nearly independently of the details of the sensor or the read-out technology. Low-temperature spectrometers can be divided into two classes - - equilibrium and non-equilibrium. In the equilibrium devices, or calorimeters, the energy is deposited in an isolated thermal mass and the resulting increase in temperature is measured. In the non-equilibrium devices, the absorbed energy produces quantized excitations that are counted to determine the energy. The two approaches have different strong points, and within each class a variety of optimizations have been pursued. I will present the basic fundamentals of operation and the details of the most successful device designs to date. I will also discuss how the measurement priorities (resolution, energy band, count rate) influence the optimal choice of detector technology.

Kilbourne, Caroline↗