Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Discharge rate measurements for Micromegas detectors in the presence of a longitudinal magnetic field

We present first discharge rate measurements for Micromegas detectors in the presence of a high longitudinal magnetic field in the GeV kinematical region. Measurements were performed by using two Micromegas detectors and a photon beam impinging a CH{sub 2} target in the Hall B of the Jefferson Laboratory. One detector was equipped with an additional GEM foil, and a reduction of the discharge probability by two orders of magnitude compared to the stand-alone Micromegas was observed. The detectors were p laced in the FROST solenoid providing a longitudinal magnetic field up to 5T. It allowed for precise measurements of the discharge probability dependence with a diffusion-reducing magnetic field. Between 0 and 5T, the discharge probability increased by a factor of 10 for polar angles between 19{degrees} and 34{degrees}. A GEANT4-based simulation developed for sparking rate calculation was calibrated against these data in order to predict the sparking rate in a high longitudinal magnetic field environment. This simulati on is then used to investigate the possible use of Micromegas in the Forward Vertex Tracker (FVT) of the future CLAS12 spectrometer. In the case of the FVT a sparking rate of 1Hz per detector was obtained at the anticipated CLAS12 luminosity.

CLAS↗

Silicon photomultiplier characterization for the GlueX barrel calorimeter

GlueX is a new detector being constructed at Jefferson Laboratory to study gluonic excitations and confinement via the detection of exotic meson states. The hermetic detector includes a barrel calorimeter where the photodetectors must operate in a high magnetic field exceeding 0.5 T. After extensive tests with a variety of sensors, the chosen photodetector will be a custom silicon photomultiplier (SiPM) array manufactured by Hamamatsu Corporation. This paper will focus on the characterization of the first 80 production samples of these SiPMs, including dark rate, photodetection efficiency (PDE), crosstalk, response uniformity and radiation tolerance.

Calorimeter↗

Relative Gain Monitoring of the GlueX Calorimeters

The relative gain of the photodetectors for the GlueX Barrel and Forward calorimeters will be monitored using modular LED driver systems. The BCAL system consists of a global controller that feeds power, bias voltage and trigger signals to 96 local controllers situated at the ends of the 48 BCAL modules, which drive 40 LEDs associated with the 40 light guides at the end of each module. The FCAL system consists also of a global controller, a local controller for each acrylic quadrant covering the face of the FCAL, and ten 4-LED pulser boards per local controller connected in a star configuration along the edges of the acrylic panes. The respective systems are currently being installed on the detectors and their tested performance is presented herein.

43 PARTICLE ACCELERATORS↗

Tracking rare-isotope beams with microchannel plates

A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival Limes of ions at the reaction target. Furthermore, the current design is an adaptation of an assembly used for low-energy beams (~1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon 56 Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of ~1 mm for beam intensities up to 5 x 10 5 pps.

43 PARTICLE ACCELERATORS↗

Beam position reconstruction for the g2p experiment in Hall A at Jefferson Lab

Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast raster system, a slow raster system was installed. We found that before and during the experiment, these new devices were tested and debugged, and their performance was also evaluated. In order to achieve the required accuracy (1-2 mm in position and 1-2 mrad in angle at the target location), the data of the BPMs and harps were carefully analyzed, as well as reconstructing the beam position and angle event by event at the target location. Finally, the calculated beam position will be used in the data analysis to accurately determine the kinematics for each event.

43 PARTICLE ACCELERATORS↗

Laser and optical system for laser assisted hydrogen ion beam stripping at SNS

A high-efficiency laser assisted hydrogen ion (H-) beam stripping was recently successfully carried out in the Spallation Neutron Source (SNS) accelerator. The experiment was not only an important step toward foil-less H- stripping for charge exchange injection, it also set up a first example of using megawatt ultraviolet (UV) laser source in an operational high power proton accelerator facility. This study reports in detail the design, installation, and commissioning result of a macro-pulsed multi-megawatt UV laser system and laser beam transport line for the laser stripping experiment.

43 PARTICLE ACCELERATORS↗

The ALICE Transition Radiation Detector: Construction, operation, and performance

The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this article, the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.

43 PARTICLE ACCELERATORS↗

A LYSO crystal array readout by silicon photomultipliers as compact detector for space applications

Precise measurements of GeV range gamma rays help narrow down among var- ious gamma emission models and increase sensitivity for dark matter searches. Construction of precise as well as compact instruments requires detectors with high efficiency, high stopping power, excellent energy resolution, and excellent angular resolution. Fast and bright crystal scintillators coupled with small foot- print photo-detectors are suitable candidates. We prototyped a detector array consisting of four LYSO crystals where each crystal is read out by a 2x2 SensL ArrayJ60035 silicon photomultipliers. The LYSO crystals were chosen because of their good light yield, fast decay time, demonstrated radiation hardness, and small radiation length. Here, we used the silicon photomultiplier arrays as photo- detectors because of their small size, simple readout, low voltage operation, and immunity to magnetic elds. We also studied the detector performance in the energy range of interest by exposing it to 2-16 GeV particles produced at the Test Beam Facility of Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗

Electron acceleration through two successive electron beam driven wakefield acceleration stages

Structure based wakefield acceleration may provide a viable approach for accelerating sufficiently large numbers of electrons and positrons at the high gradient needed to meet the luminosity, efficiency, and cost requirements of a future linear collider. An important step in proving its viability is the demonstration of acceleration in multiple stages. Here we show the results of the first experimental demonstration of staged two beam wakefield acceleration, conducted at the Argonne Wakefield Accelerator Facility (AWA), in which a 0.5 nC electron bunch gained equal amounts of energy in two stages (~2.4 MeV per stage, corresponding to an average acceleration gradient of ~70 MeV/m). Meanwhile 150MeV/m of acceleration in a single stage has been achieved. The demonstration experiment should be scalable to staged-acceleration at gradients of the order of 200 to 300 MeV/m. Furthermore, such a development would considerably reduce both the cost and footprint of both a future high-energy physics (HEP) collider, as well as future X-ray light sources.

43 PARTICLE ACCELERATORS↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Characterization of 4H-SiC Low Gain Avalanche Detectors (LGADs)

4H-SiC Low Gain Avalanche Detectors (LGADs) have been fabricated and characterized. The devices employ a circular mesa design with low-resistivity contacts and an SiO 2 passivation layer. The I–V and C–V characteristics of the 4H-SiC LGADs are compared with complementary 4H-SiC PiN diodes to confirm a high breakdown voltage and low leakage current. Both LGADs and PiN diodes were irradiated with alpha particles from a $^{210}_{84}$Po source. The charge collected by each device was compared, and it was observed that low-gain charge carrier multiplication is achieved in the 4H-SiC LGAD.

43 PARTICLE ACCELERATORS↗

Detector development for Jefferson Lab's 12GeV Upgrade

Jefferson Lab will soon finish its highly anticipated 12 GeV Upgrade. With doubled maximum energy, Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) will enable a new experimental program with substantial discovery potential, addressing important topics in nuclear, hadronic and electroweak physics. In order to take full advantage of the high energy, high luminosity beam, new detectors are being developed, designed and constructed to fit the needs of different physics topics. The paper will give an overview of various new detector technologies to be used for 12 GeV experiments. It will then focus on the development of two solenoid-based spectrometers, the GlueX and SoLID spectrometers. The GlueX experiment in Hall D will study the complex properties of gluons through exotic hybrid meson spectroscopy. The GlueX spectrometer, a hermetic detector package designed for spectroscopy and the associated partial wave analysis, is currently in the final stage of construction. Hall A, on the other hand, is developing the SoLID spectrometer to capture the 3D image of the nucleon from semi-inclusive processes and to study the intrinsic properties of quarks through mirror symmetry breaking. Such a spectrometer will have the capability to handle very high event rates while still maintaining a large acceptance in the forward region.

43 PARTICLE ACCELERATORS↗

Modeling charge collection efficiency degradation in partially depleted GaAs photodiodes using the 1- and 2-carrier Hecht equations

Here, the Hecht equation can be used to model the nonlinear degradation of charge collection efficiency (CCE) in response to radiation-induced displacement damage in both fully and partially depleted GaAs photodiodes. CCE degradation is measured for laser-generated photocurrent as a function of fluence and bias in Al 0.3 Ga 0.7 As/GaAs/Al 0.25 Ga 0.75 As p-i-n photodiodes which have been irradiated with 12 MeV C and 7.5 MeV Si ions. CCE is observed to degrade more rapidly with fluence in partially depleted photodiodes than in fully depleted photodiodes. When the intrinsic GaAs layer is fully depleted, the 2-carrier Hecht equation describes CCE degradation as photogenerated electrons and holes recombine at defect sites created by radiation damage in the depletion region. If the GaAs layer is partially depleted, CCE degradation is more appropriately modeled as the sum of the 2-carrier Hecht equation applied to electrons and holes generated within the depletion region and the 1-carrier Hecht equation applied to minority carriers that diffuse from the field-free (non-depleted) region into the depletion region. Enhanced CCE degradation is attributed to holes that recombine within the field-free region of the partially depleted intrinsic GaAs layer before they can diffuse into the depletion region.

43 PARTICLE ACCELERATORS↗

Commissioning of the Advanced Rare Isotope Separator ARIS at FRIB

The Facility for Rare Isotope Beams (FRIB) at Michigan State University (MSU) consists of a newly constructed linear accelerator and fragment separator that are designed for enhanced production rates of rare isotopes for use in research and other societal applications. Recent activities through to August 2022 took place to commission the Advanced Rare Isotope Separator (ARIS) and carry out the first experiments. This followed commissioning of the newly constructed linac that is designed to provide orders of magnitude higher beam power than the previously coupled cyclotrons. This required that more advanced target, beam dump, and collimation systems of the new separator be designed and constructed to sustain unprecedented conditions by heavy ion beams. Commissioning with ~1 kW beams began recently and results from activities that began in late 2021 are reported here. Comparisons between the previous and current facilities are provided.

43 PARTICLE ACCELERATORS↗

Finite element analysis of the impact of beam heating mode in molten salt corrosion experiments employing simultaneous ion irradiation

Finite element analysis was used to investigate the temperature and stress profiles that develop in 316L stainless steel membranes being irradiated using different proton beam conditions in contact with a molten salt environment. It was shown that in addition to a nonuniform irradiation profile, a focused 2 MeV proton beam leads to very strong temperature and stress gradients in the membrane, introducing highly localized driving forces that complicate and even compromise the integrity and reliability of the experimental results of corrosion studies. Here, the use of a focused beam in corrosion studies can create experimental artifacts that may misrepresent the true corrosion behavior. In contrast, the use of a rastered beam is shown to distribute the protons and resulting radiation damage uniformly across the membrane face, and more importantly, results in temperature and stress profiles that are not only very uniform but are of much lower magnitude. The use of a rastered beam during molten salt corrosion experiments is therefore recommended to achieve uniform damage rates, thereby reducing both gradients and magnitudes of the temperature and stress distributions.

43 - PARTICLE ACCELERATORS↗