Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Build solar-energy systems to last — save billions

Here, to withstand extreme weather, rapid innovation and rock-bottom prices, solar installations need tighter quality control, standards and testing. Solar energy is being adopted the world over. Prices have plunged 100-fold since 1980. By 2023, the installed capacity of photovoltaics globally is expected to surpass 1 terawatt — 30–100 TW will be required by 2050. Yet colliding trends mean that many of the technologies being installed today might not last until then if quality is not assured.

14 SOLAR ENERGY↗

Overview of Opportunities for Co-Location of Solar Energy Technologies and Vegetation

Large-scale solar facilities have the potential to contribute significantly to national electricity production. Many solar installations are large-scale or utility-scale, with a capacity over 1 MW and connected directly to the electric grid. Large-scale solar facilities offer an opportunity to achieve economies of scale in solar deployment, yet there have been concerns about the amount of land required for solar projects and the impact of solar projects on local habitat. During the site preparation phase for utility-scale solar facilities, developers often grade land and remove all vegetation to minimize installation and operational costs, prevent plants from shading panels, and minimize potential fire or wildlife risks. However, the common site preparation practice of removing vegetation can be avoided in certain circumstances, and there have been successful examples where solar facilities have been co-located with agricultural operations or have native vegetation growing beneath the panels. In this study we outline some of the impacts that large-scale solar facilities can have on the local environment, provide examples of installations where impacts have been minimized through co-location with vegetation, characterize the types of co-location, and give an overview of the potential benefits from co-location of solar energy projects and vegetation. The varieties of co-location can be replicated or modified for site-specific use at other solar energy installations around the world. We conclude with opportunities to improve upon our understanding of ways to reduce the environmental impacts of large-scale solar installations.

14 SOLAR ENERGY↗

Agent-Based Modeling for the Circular Economy: Lessons Learned From Three Case Studies

The circular economy (CE) aims at decoupling human activities from resource use, creating wealth in the process. Recently, many scholars have questioned the link between increased circularity and sustainability, resulting in many methodological approaches being developed for that purpose. This presentation summarizes the insights gained from the application of agent-based modeling (ABM) to study the techno-economic and social conditions promoting circularity and sustainability of three technologies: photovoltaic (PV) modules, hard disk drives (HDDs), and wind blades. Four main categories of agents are defined in the ABM: asset owners, service providers (e.g., refurbishers), recyclers, and manufacturers. Two main CE strategies are represented: lifetime extension (through repair or reuse) and recycling. The developed models start by projecting installed capacities and end-of-life (EOL) quantities. Then the theory of planned behavior - a social psychology model explaining behavior adoption based on attitude, peer influence, and costs - is used to model the asset owners' EOL decision (i.e., landfill, recycle or extend the lifetime of the asset). Then, the quantities of assets flowing to the recycler and service provider agents and quantities of materials flowing to manufacturers are computed. Recyclers' economies of scale are dynamically modeled, and the value generated by the CE strategies for the recyclers, service providers, and manufacturers is computed within the model. When data are available, avoided greenhouse gas emissions resulting from the CE strategies adoption are calculated exogenously from the ABM simulations. Results show that with improved used PV modules warranties, the reuse CE strategy adoption increases from 1% to 23% between 2020 and 2050. Similarly, improved standards could enhance HDDs end-users trust in data-wiping - a prerequisite to reuse - leading to a 3-fold increase in the reuse rate and avoid about 5 million tons of CO2 eq by 2050. Regarding wind blades, 5-15 years lifetime extension could reduce EOL blade quantities by 13%. High costs and logistic issues prevent blades from being recycled in greater quantities. One insight from the case studies is the necessity to have mature secondary markets for reuse to be a viable option. Interestingly, PV reuse is limited by the willingness of PV owners to purchase used modules (on the demand side), while HDDs reuse is constrained by the lack of trust toward data-wiping (limiting the supply of used HDDs). The six limits of the CE concepts presented by Korhonen et al. (2018) are finally used to interpret the results. The HDD case study is an exemplary lock-in, where the first accepted practice (shredding) retains most of the market. The PV results illustrate the technical limitation to reuse, as the growing demand cannot be supplied entirely with used PV modules. The wind case study shows the relevance of clearly defining physical flows - what type of waste should wind blades be considered, how should they be transported and landfilled? - a crucial consideration that also applies to PV modules. Finally, the three case studies highlight the relevance of studying a technology's technical, economic, and market material efficiency potentials altogether and the potential benefit of coupling ABM to life cycle assessment.

agent-based modeling↗

Going to the Next Level: The Growth of Distributed Energy Resources [Guest Editorial]

The six articles in this special section focus on distributed energy resources (DERs). Since the first issue in this magazine on DER grid integration in the summer of 2009, DERs, specifically, solar PV-based systems, have evolved considerably to meet the needs of the power system from a planning and operations perspective. The result of this evolution is the theme of this issue: DERs play a major role in the power system. When relatively small numbers of PVs were first being installed, they were often showcases or demonstrations for the underlying technology, which was still quite expensive. The grid integration of these systems was a great research project, but many impacts we now see regularly simply did not exist at the earlier low-penetration levels. Now, nearly every distribution utility has experienced at least a few instances and challenges of DER integration within its service territory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of high concentration photovoltaics (HCPV) power plants in the US Southwest: Economic assessment and sensitivity analysis

High concentration photovoltaic (HCPV) technologies offer several advantages over typical PV systems. In this study, a detailed economic assessment and sensitivity analysis of deploying HCPV plants in the US southwest is performed. To do this, a 20 MWdc HCPV power plant is designed using the System Advisor Model (SAM) and is evaluated from both technical and financial aspects. The sensitivity analysis shows that reducing the installed cost per capacity of the HCPV system can significantly improve the economics and reduce the levelized cost of electricity (LCOE) and levelized power purchase agreement (LPPA). Also, providing proper incentives including both investment tax credits (ITC) and production tax credit (PTC), loan debt ratio, and interest rate are among the most influential parameters. The analysis shows that with the 30% ITC, the LCOE, and LPPA of the designed HCPV projects are between $65.4/MWh and $69.3/MWh and between $71.0/MWh and $75.2/MWh, respectively. The estimated LCOE and LPPA values are almost 50% higher than the utility-scale PV projects. If proper funding is provided to continue the support of the HCPV system, they would become more economical and competitive with PV plants. Federal and state government policies must also be established to advocate HCPV systems.

14 SOLAR ENERGY↗

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY↗

Impact of Solar Array Position on ISS Vehicle Charging

The International Space Station (ISS), because of its large structure and high voltage solar arrays, has a complex plasma interaction with the ionosphere in low Earth orbit (LEO). This interaction of the ISS US Segment photovoltaic (PV) power system with the LEO ionospheric plasma produces floating potentials on conducting elements of the ISS structure relative to the local plasma environment. To control the ISS floating potentials, two Plasma Contactor Units (PCUs) are installed on the Z1 truss. Each PCU discharges accumulated electrons from the Space Station structure, thus reducing the potential difference between the ISS structure and the surrounding charged plasma environment. Operations of the PCUs were intended to keep the ISS floating potential to 40 Volts (Reference 1). Exposed dielectric surfaces overlying conducting structure on the Space Station will collect an opposite charge from the ionosphere as the ISS charges. In theory, when an Extravehicular Activity (EVA) crewmember is tethered to structure via the crew safety tether or when metallic surfaces of the Extravehicular Mobility Unit (EMU) come in contact with conducting metallic surfaces of the ISS, the EMU conducting components, including the perspiration-soaked crewmember inside, can become charged to the Space Station floating potential. The concern is the potential dielectric breakdown of anodized aluminum surfaces on the EMU producing an arc from the EMU to the ambient plasma, or nearby ISS structure. If the EMU arcs, an electrical current of an unknown magnitude and duration may conduct through the EVA crewmember, producing an unacceptable condition. This electrical current may be sufficient to startle or fatally shock the EVA crewmember (Reference 2). Hence, as currently defined by the EVA community, the ISS floating potential for all nominal and contingency EVA worksites and translation paths must have a magnitude less than 40 volts relative to the local ionosphere at all times during EVA. Arcing from the EMU is classified as a catastrophic hazard, which requires two-failure tolerant controls, i.e., three hazard controls. Each PCU is capable of maintaining the ISS floating potential below the requirement during EVA. The two PCUs provide a single failure tolerant control of ISS floating potential. In the event of the failure of one or two PCUs, a combination of solar array shunting and turning the solar arrays into their own wakes will be used to supply control of the plasma hazard (Reference 3). The purpose of this paper is to present on-orbit information that shows that ISS solar array placement with respect to the ISS velocity vector can control solar array plasma charging, and hence, provide an operational control for the plasma hazard. Also, this paper will present on-orbit information that shows that shunting of the ISS solar arrays can control solar array plasma charging, and hence, provide an additional operational control for the plasma hazard.

Alred, John↗

Ground-Mounted Solar Array in Hospitality

This case study describes how Marriott franchise TownePlace Suites developed a large solar installation on a previously unused four-acre piece of land adjoining the hotel.

Commercial, hospitality, hotel, ground mounted arr↗

Utility-Scale Solar 2014. An Empirical Analysis of Project Cost, Performance, and Pricing Trends in the United States

Other than the nine Solar Energy Generation Systems (“SEGS”) parabolic trough projects built in the 1980s, virtually no large-scale or “utility-scale” solar projects – defined here to include any groundmounted photovoltaic (“PV”), concentrating photovoltaic (“CPV”), or concentrating solar thermal power (“CSP”) project larger than 5 MW AC – existed in the United States prior to 2007. By 2012 – just five years later – utility-scale had become the largest sector of the overall PV market in the United States, a distinction that was repeated in both 2013 and 2014 and that is expected to continue for at least the next few years. Over this same short period, CSP also experienced a bit of a renaissance in the United States, with a number of large new parabolic trough and power tower systems – some including thermal storage – achieving commercial operation. With this critical mass of new utility-scale projects now online and in some cases having operated for a number of years (generating not only electricity, but also empirical data that can be mined), the rapidly growing utility-scale sector is ripe for analysis. This report, the third edition in an ongoing annual series, meets this need through in-depth, annually updated, data-driven analysis of not just installed project costs or prices – i.e., the traditional realm of solar economics analyses – but also operating costs, capacity factors, and power purchase agreement (“PPA”) prices from a large sample of utility-scale solar projects in the United States. Given its current dominance in the market, utility-scale PV also dominates much of this report, though data from CPV and CSP projects are presented where appropriate.

14 SOLAR ENERGY↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fundamentals Approach to Plant Capacity Testing

This paper provides a recommended method for evaluating the AC capacity of a photovoltaic (PV) generating station. It also presents companion guidance on setting the facilitys capacity guarantee value. This is a principles-based approach that incorporates plant fundamental design parameters such as loss factors, module coefficients, and inverter constraints. This method has been used to prove contract guarantees for over 700 MW of installed projects. The method is transparent, and the results are deterministic. In contrast, current industry practices incorporate statistical regression where the empirical coefficients may only characterize the collected data. Though these methods may work well when extrapolation is not required, there are other situations where the empirical coefficients may not adequately model actual performance.This proposed Fundamentals Approach method provides consistent results even where regression methods start to lose fidelity.

14 SOLAR ENERGY↗

Combined Transmission and Distribution Test System to Study High Penetration of Distributed Solar Generation

Transmission and distribution (T&D) standard test systems are currently defined separately, and are critical for researchers and engineers to test new solutions. Growing installation of energy resources in distribution and sub-transmission systems is creating higher interactions between T&D systems. This paper proposes a standard test system to study T&D interactions for high penetration of solar photovoltaic (PV) generation. The proposed test system can be used to study and propose solutions to problems such as reverse power flows and voltage control affected by PV variability. The proposed test system combines the transmission IEEE 118 bus system, with the distribution IEEE 123-node feeder. The original test systems are significantly enhanced by adding high penetration of solar PV generation with corresponding full-year minute-resolution chronological data. Conventional generation chronology is achieved by adding dispatch and unit commitment data for AC optimal power flow solutions. And chronological load data is added in both aggregated and disaggregated fashions. Sample applications of the data are provided highlighting voltage control challenges, and the proposed system is made available openly online.

Samaan, Nader A.↗

Home Owners Association Checklist

The following checklist is to assist in determining if a Solar Installation can be prohibited or forced to relocate in accordance with Texas House Bill Number 362.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermally Conductive Backsheets (TCB) of PV Modules: Positive Impacts on Performance, Lifetime and LCOE

The operating temperatures of photovoltaic (PV) modules can be impacted by the selection of specific packaging materials, e.g., backsheets and encapsulants. This research focuses on the evaluation of operating temperature reduction of one-cell modules by comparing conventional Tedlar/polyester/Tedlar (TPT) backsheet with novel thermally conductive backsheets (TCBs) materials. A large number of one-cell modules with two TCB types (TCB_A and TCB_B) and baseline TPT type were fabricated and installed in three different climatic conditions of the hot-dry desert in Arizona (high and low wind speed locations) and North Carolina (temperate with low wind speed location). In this study, these two TCBs were compared with conventional TPT backsheet in terms of performance, lifetime and levelized cost of energy (LCOE). The field results were analyzed for thermal performance of TCBs compared to TPT at three sites for two and half years. This study concludes that the thermal and electrical performances of the PV modules can be improved by using TCB_A in hot and dry climate sites and TCB_B at temperate climate sites. Therefore, the lifetime of TCB-based modules is expected to be higher than TPT-based modules. Using backsheet-specific power degradation levels and assuming the same cost for both types of backsheets, the LCOE of modules using TCBs is estimated to be lower than that of TPT.

14 SOLAR ENERGY↗

GaAs/silicon PVMirror tandem photovoltaic mini‐module with 29.6% efficiency with respect to the outdoor global irradiance

Abstract Balance‐of‐system costs now dominate the installed cost of photovoltaic systems, causing the annually averaged module efficiency to become a primary system cost driver. The resulting continued push towards higher module efficiencies, coupled with the dominance of single‐axis tracking in the utility‐scale PV market, may create an opportunity for a low‐concentration tandem module technology. Here, we demonstrate such a tandem, using the “PVMirror” concept, on the mini‐module scale. The tandem couples a (concentrating) silicon PVMirror having an aperture area of 156.25 cm 2 with a gallium arsenide receiver to achieve 29.6% efficiency with respect to the outdoor global irradiance. Unlike most concentrating technologies, the silicon PVMirror collects some of the diffuse light, but the tandem would nevertheless achieve 31% efficiency in the absence of diffuse light, as in a laboratory measurement. The same tandem technology can be implemented with a wide‐bandgap thin‐film PVMirror and silicon receiver—a potentially cost‐competitive combination—when efficient wide‐bandgap cells have been developed.

Yu, Zhengshan J.↗

Evaluating the Incident Energy of Arcs in Photovoltaic DC Systems: Comparison Between Calculated and Experimental Data

Solar Photovoltaic (PV) systems have permeated the energy generation world at a very high rate, some of the safety codes and standards are still lagging in accurately assessing the hazards and risks associated with PV array arcing energies. Safety professionals and maintenance workers using NFPA 70E have utilized the Doan, Stokes & Oppenlander or Enrique models, meant to determine arc energies in DC power systems using the maximum power method. These methods may lead to an overestimate of energy available in PV systems during a fault. Since PV modules/arrays are non-linear, current limited DC devices, some of these calculation methods may not accurately predict fault energy. This paper will validate current arc energy models for PV systems by comparing experimental and calculated data. Additionally, this data will help modify the current NFPA 70E models related to smaller solar arrays. Understanding where the real safety threshold for DC arc flash in PV systems exists will help maintenance and safety professionals better prepare for a variety of work related activities. This paper will analyze real arc data taken for PV systems <1000VDC and <60amps and compare this to the calculated incident energy models, to include 70E. Thus, using these comparisons, it may be possible to reduce the safety hazard severity and thus relax the PPE requirements for installation and maintenance crews.

14 SOLAR ENERGY↗

Albedo Measurement of the Terra Pave White Albedo Product: Cooperative Research and Development Final Report

The Terra Pave team is creating an eco-friendly, cost-effective road coating that controls dust and dirt on high-traffic roads near solar field installations to reduce the dirt cover on panels, which lowers energy output. The Terra Pave White Albedo product also has the capability to increase the amount of solar radiation reflected from the ground to the backside of bifacial PV modules, thereby increasing the amount of electricity generated. This work will quantify the amount of solar radiation reflected from the Terra Pave White albedo product by measuring its albedo, which is the ratio of the reflected radiation to the incoming radiation. Albedo is measured with two horizontal pyranometers with one ground-facing and the other sky-facing.

14 SOLAR ENERGY↗

DOE Zero Energy Ready Home Case Study HIA 2020: United Way of Long Island, Net Positive All Electric Home, Port Jefferson Station, NY

Case study of a DOE 2020 Housing Innovation Award winning custom home in a mixed-humid climate that got a HERS -2 with PV, with 2,500 square feet, featuring a novel attic truss specifically designed to accommodate a ducted mini-split heat pump tucked into an insulated chase in the vented attic. The walls are constructed of 2x6 studs installed at 24 inches on center and incorporating advanced framing techniques to reduce the amount of lumber needed and to provide more room for insulation.

Building America, residential construction, home b↗