Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PUMPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Optimization of a photovoltaic pumping system based on the optimal control theory

This paper suggests how an optimal operation of a photovoltaic pumping system based on an induction motor driving a centrifugal pump can be realized. The optimization problem consists in maximizing the daily pumped water quantity via the optimization of the motor efficiency for every operation point. The proposed structure allows at the same time the minimization the machine losses, the field oriented control and the maximum power tracking of the photovoltaic array. This will be attained based on multi-input and multi-output optimal regulator theory. The effectiveness of the proposed algorithm is described by simulation and the obtained results are compared to those of a system working with a constant air gap flux. (author)

14 SOLAR ENERGY↗

Optical Pumping Spin Exchange {sup 3}He Gas Cells for Magnetic Resonance Imaging

We present a device for spin-exchange optical pumping system to produce large quantities of polarized noble gases for Magnetic Resonance Imaging (MRI). A method and design of apparatus for pumping the polarization of noble gases is described. The method and apparatus enable production, storage and usage of hyperpolarized noble gases for different purposes, including Magnetic Resonance Imaging of human and animal subjects. Magnetic imaging agents breathed into lungs can be observed by the radio waves of the MRI scanner and report back physical and functional information about lung's health and desease. The technique known as spin exchange optical pumping is used. Nuclear magnetic resonance is implemented to measure the polarization of hyperpolarized gas. The cells prepared and sealed under high vacuum after handling Alkali metals into the cell and filling with the {sup 3}He-N{sub 2} mixture. The cells could be refilled. The {sup 3}He reaches around 50% polarization in 5-15 hours.

60 APPLIED LIFE SCIENCES↗

Enhancement of {sup 129}Xe polarization by off-resonant spin exchange optical pumping

A high power narrow line width (38 W, 0.09 nm full width at half maximum) external cavity diode laser is investigated for rubidium spin exchange optical pumping of {sup 129}Xe. This tunable photon source has a constant line width, independent of operating power or wavelength within a 1 nm tuning range. When using this laser, an increase in the {sup 129}Xe nuclear polarization is observed when optically pumping at a lower wavelength than the measured Rb electron D{sub 1} absorption. The exact detuning from D{sub 1} for the highest polarization is dependent upon the gas density. Furthermore, at high power and/or high Rb density, a reduction in the polarization occurs at the optimum wavelength as previously reported in spin exchange optical pumping studies of {sup 3}He which is consistent with high absorption close to the cell front face. These results are encouraging for moderate high throughput polarization of {sup 129}Xe in the midpressure range of (0.5-2.0 amagat).

74 ATOMIC AND MOLECULAR PHYSICS↗

Efficient single-mode (TEM{sub 00}) Nd : YVO{sub 4} laser with longitudinal 808-nm diode pumping

A single-mode Nd : YVO{sub 4} laser with unidirectional longitudinal pumping by laser diodes with λ = 808 nm and a power of 40 W is studied. In the TEM{sub 00} mode, the output laser power is 24 W with the optical efficiency η{sub opt} = 57.1 % (slope efficiency 63.3 %), which, as far as we know, is the best result for Nd{sup 3+} : YVO{sub 4} lasers with longitudinal pumping at λ = 808 nm from one face of the active crystal. Estimates of thermal effects show that, using a Nd : YVO{sub 4} crystal (length 20 mm, diameter 3 mm, dopant concentration 0.27 at%) with two undoped ends and bidirectional diode pumping with a total power of 170 W, one can obtain an output power of ∼100 W in the TEM{sub 00} mode from one active element. (lasers)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of characteristics of a diode-pumped rubidium vapour laser using a kinetic algorithm

We consider diode-pumped alkali vapour lasers (DPALs), which make it possible to achieve a high output power. Characteristics of such DPALs strongly depend on the physical properties of buffer gases and on structural parameters of a vapour cell. Special attention is paid to a diode-pumped rubidium vapour laser (DPRVL): We have investigated the effect of different conditions on its characteristics. The results show that the linewidth of the D{sub 2} line of a DPRVL and the fine-structure mixing rate between two excited energy levels, which are two crucial factors in implementing a high-power DPRVL, increase with the pressure of buffer gases and the temperature of the vapour cell. It is demonstrated that the population ratio of two excited energy levels is close to that corresponding to a thermal equilibrium as the pressure of buffer gases and the temperature of the vapour cell become higher. We have found that the optimal values of the methane pressure, the cell temperature and the cell length can be determined through a kinetic analysis. The conclusions can be valuable for designing configurations of an end-pumped DPAL. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strong effective saturation by optical pumping in three-level systems

We have studied nonlinear absorption from the In P{sub 1/2,3/2} ground-state doublet in a resistively heated high-temperature cell and a hollow cathode lamp. Using probe and pump lasers at 410 and 451 nm, respectively, absorption spectra with nonlinear properties caused by saturated absorption, coherent dark resonances, and optical pumping are observed. A theoretical description in terms of a density-matrix theory agrees very well with the observed spectra and identifies optical pumping as a dominating process of broadening in the stepwise contribution rather than velocity-changing collisions. Our experiments suggest that the theory used here is widely applicable in saturation spectroscopy on three-level LAMBDA systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optically pumped atoms with velocity- and spin-changing collisions at low gas pressures

We discuss optical pumping when (a) the collision rates of optically pumped atoms with atoms or molecules of the background gas are small enough that individual velocity groups can be preferentially excited by a monochromatic light beam, (b) the collision rates are still fast enough to partially transfer the spin polarization to other velocity groups, and (c) there are nonnegligible losses of polarization due to collisional spin relaxation and Larmor precession. These conditions lead to a strong correlation between the velocity and the spin polarization of the atoms - that is, to 'spin-tagging' of the different velocity groups. This regime is similar to that of optically pumped {sup 23}Na atoms of the Earth's upper atmosphere, but it is seldom encountered in laboratory experiments. For cooling and trapping experiments, the collision rates with background gas are negligible. For gas-cell experiments the velocity-changing rates are normally so fast compared to spin relaxation or Larmor precession rates that the atoms have a Maxwellian velocity distribution with negligible correlation between the spin polarization and the velocity. We analyze the limiting cases of strong and weak collisions, which change the velocity by a large or small fraction, respectively, of the mean thermal velocity. The Keilson-Storer model [J. Keilson and A. E. Storer, Q. Appl. Math. 10, 243 (1952)] is used to discuss strong collisions, with memory parameter {alpha}=0 and weak collisions with {alpha}{yields}1. For weak collisions, the physics can be modeled by coupled Fokker-Planck equations, identical to those for forced diffusion in a harmonic-oscillator potential well. In this limit there are solutions analogous to the quantum mechanical coherent states of a harmonic oscillator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid Optical Pumping of Optically Dense Alkali-Metal Vapor without Quenching Gas

Optical pumping of an optically thick atomic vapor typically requires a quenching buffer gas, such as N{sub 2}, to prevent radiation trapping of unpolarized photons which would depolarize the atoms. We show that optical pumping of a trace contamination of Rb present in K metal results in a 4.5 times higher polarization of K than direct optical pumping of K in the absence of N{sub 2}. Such spin-exchange polarization transfer from optically thin species is useful in a variety of areas, including spin-polarized nuclear scattering targets and electron beams, quantum-nondemolition spin measurements, and ultrasensitive magnetometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laboratory Test Report for Fujitsu 12RLS and Mitsubishi FE12NA Mini-Split Heat Pumps

Mini-split heat pumps are being proposed as a new retrofit option to replace resistance heating in the Pacific Northwest. NREL has previously developed a field test protocol for mini-split systems to ensure consistent results from field tests. This report focuses on the development of detailed system performance maps for mini-split heat pumps so that the potential benefits of mini-split systemscan be accurately analyzed for different climate regions and housing types. This report presents laboratory test results for two mini-split heat pumps. Steady-state heating and cooling performance for the Fujitsu 12RLS and Mitsubishi FE12NA was tested under a wide range of outdoor and indoor temperatures at various compressor and fan speeds. Cycling performance for each unit was also testedunder both modes of operation. Both systems performed quite well under low loads and the experimental test data aligned with manufacturer reported values. Adequate datasets were attained to promote performance modeling of these two systems in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Blender Pump Fuel Survey: CRC Project E-95-2

With the increasing fuel diversity in the marketplace, the Coordinating Research Council and the U.S. Department of Energy's National Renewable Energy Laboratory conducted a survey of mid-level ethanol blends (MLEBs) in the market. A total of 73 fuel samples were collected from 20 retail stations. To target Class 4 volatility, the fuel samples were collected primarily in the midwestern United States in the month of February. Samples included the gasoline (E0), Flex Fuel, and every MLEB that was offered from each of the 20 stations. Photographs of each station were taken at the time of sample collection, detailing the pump labeling and configuration. The style and labeling of the pump, hose, and dispenser nozzle are all important features to prevent misfueling events. The physical location of the MLEB product relative to the gasoline product can also be important to prevent misfueling. In general, there were many differences in the style and labeling of the blender pumps surveyed in this study. All samples were analyzed for volatility and ethanol content. For the MLEB samples collected, the fuels tended to be lower in ethanol content than their indicated amount; however, the samples were all within 10 vol% of their indicated blend level. One of the 20 Flex Fuel samples was outside of the allowable limits for ethanol content. Four of the 20 Flex Fuel samples had volatility below the minimum requirement for Class 4.

30 DIRECT ENERGY CONVERSION↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units With Exhaust Air Energy Recovery

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chemical Sensing and Chemoresponsive Pumping with Conical-Pore Polymeric Membranes

Synthetic membranes containing asymmetrically shaped pores have been shown to rectify the ionic current flowing through the membrane. Ion-current rectification means that such membranes produce nonlinear current–voltage curves analogous to those observed with solid-state diode rectifiers. In order to observe this ion-current rectification phenomenon, the asymmetrically shaped pores must have pore-wall surface charge. Pore-wall surface charge also allows for electroosmotic flow (EOF) to occur through the membrane. We have shown that, because ion-current is rectified, EOF is likewise rectified in such membranes. This means that flow through the membrane depends on the polarity of the voltage applied across the membrane, one polarity producing a higher, and the opposite producing a lower, flow rate. As is reviewed here, these ion-current and EOF rectification phenomena are being used to develop new sensing technologies. Results obtained from an ion-current-based sensor for hydrophobic cations are reviewed. In addition, ion-current and EOF rectification can be combined to make a new type of device—a chemoresponsive nanofluidic pump. This is a pump that either turns flow on or turns flow off, when a specific chemical species is detected. Results from a prototype Pb 2+ chemoresponsive pump are also reviewed here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fakir fuel pump

In designing the Fakir fuel pump, the fundamental idea was to obtain a simple and reliable method of conveying the fuel from a low tank to the carburetor, with the avoidance of the faults of all former methods and the simultaneous warming of the fuel by means of the heat of compression generated. The principle of the Fakir fuel pump rests on the well-known principle of the diaphragm pump, which must be suitably adapted to the present purpose.

PUMPS, FUEL↗

Development of Environmentally Benign Heat Pump Water Heaters for the US Market

Improving energy efficiency in water heating applications is important to the nation's energy strategies. Water heating in residential and commercial buildings accounts for about 10% of U.S. buildings energy consumption. Heat pump water heating (HPWH) technology is a significant breakthrough in energy efficiency, as an alternative to electric resistance water heating. Heat pump technology has shown acceptable payback period with proper incentives and successful market penetration is emerging. However, current HPWH require the use of refrigerants with high Global Warming Potential (GWP). Furthermore, current system designs depend greatly on the backup resistance heaters when the ambient temperature is below freezing or when hot water demand increases. Finally, the performance of current HPWH technology degrades greatly as the water set point temperature exceeds 330 K. This paper presents the potential for carbon dioxide, CO2, as a natural, environmentally benign alternative refrigerant for HPWH technology. In this paper, we first describe the system design, implications and opportunities of operating a transcritical cycle. Next, a prototype CO2 HPWH design featuring flexible component evaluation capability is described. The experimental setup and results are then illustrated followed by a brief discussion on the measured system performance. The paper ends with conclusions and recommendations for the development of CO2 heat pump water heating technology suitable for the U.S. market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Highlight: NREL Tests Integrated Heat Pump Water Heater Performance in Different Climates (Fact Sheet)

This technical highlight describes NREL tests to capture information about heat pump performance across a wide range of ambient conditions for five heat pump water heaters (HPWH). These water heaters have the potential to significantly reduce water heater energy use relative to traditional electric resistance water heaters. These tests have provided detailed performance data for these appliances, which have been used to evaluate the cost of saved energy as a function of climate. The performance of HPWHs is dependent on ambient air temperature and humidity and the logic controlling the heat pump and the backup resistance heaters. The laboratory tests were designed to measure each unit's performance across a range of air conditions and determine the specific logic controlling the two heat sources, which has a large effect on the comfort of the users and the energy efficiency of the system. Unlike other types of water heaters, HPWHs are both influenced by and have an effect on their surroundings. Since these effects are complex and different for virtually every house and climate region, creating an accurate HPWH model from the data gathered during the laboratory tests was a main goal of the project. Using the results from NREL's laboratory tests, such as the Coefficient of Performance (COP) curves for different air conditions as shown in Figure 1, an existing HPWH model is being modified to produce more accurate whole-house simulations. This will allow the interactions between the HPWH and the home's heating and cooling system to be evaluated in detail, for any climate region. Once these modeling capabilities are in place, a realistic cost-benefit analysis can be performed for a HPWH installation anywhere in the country. An accurate HPWH model will help to quantify the savings associated with installing a HPWH in the place of a standard electric water heater. In most locations, HPWHs are not yet a cost-effective alternative to natural gas water heaters. The detailed system performance maps that were developed by this testing program will be used to: (1) Target regions of the country that would benefit most from this technology; (2) Identify improvements in current systems to maximize homeowner cost savings; and (3) Explore opportunities for development of advanced hot water heating systems.

03 NATURAL GAS↗

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

air-source heat pumps↗

Guide to Geothermal Heat Pumps

Geothermal heat pumps, also known as ground source heat pumps, geoexchange, water-source, earth-coupled, and earth energy heat pumps, take advantage of this resource and represent one of the most efficient and durable options on the market to heat and cool your home.

geothermal heat pumps, cooling technologies, groun↗