Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Oscillation modes of direct current microdischarges with parallel-plate geometry

Two different oscillation modes in microdischarge with parallel-plate geometry have been observed: relaxation oscillations with frequency range between 1.23 and 2.1 kHz and free-running oscillations with 7 kHz frequency. The oscillation modes are induced by increasing power supply voltage or discharge current. For a given power supply voltage, there is a spontaneous transition from one to other oscillation mode and vice versa. Before the transition from relaxation to free-running oscillations, the spontaneous increase of oscillation frequency of relaxation oscillations form 1.3 kHz to 2.1 kHz is measured. Fourier transform spectra of relaxation oscillations reveal chaotic behavior of microdischarges. Volt-ampere (V-A) characteristics associated with relaxation oscillations describes periodical transition between low current, diffuse discharge, and normal glow. However, free-running oscillations appear in subnormal glow only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Circular multilayer zone plate for high-energy x-ray nano-imaging

A circular multilayer zone plate (MZP) was fabricated and its focusing performance was evaluated using 20-keV x-rays. MoSi{sub 2} and Si layers were alternately deposited by DC magnetron sputtering on a wire core; all the interfaces satisfied the Fresnel zone condition. The measured line spread function was converted to a point spread function by tomographic reconstruction. The results suggest that the MZP has the potential to realize the diffraction-limited resolving power, which is calculated to be 35 nm using the diffraction integral. Furthermore, scanning transmission microscopy using the MZP could resolve a 50-nm line-and-space pattern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thomson spectrometer-microchannel plate assembly calibration for MeV-range positive and negative ions, and neutral atoms

We report on the absolute calibration of a microchannel plate (MCP) detector, used in conjunction with a Thomson parabola spectrometer. The calibration delivers the relation between a registered count numbers in the CCD camera (on which the MCP phosphor screen is imaged) and the number of ions incident on MCP. The particle response of the MCP is evaluated for positive, negative, and neutral particles at energies below 1 MeV. As the response of MCP depends on the energy and the species of the ions, the calibration is fundamental for the correct interpretation of the experimental results. The calibration method and arrangement exploits the unique emission symmetry of a specific source of fast ions and atoms driven by a high power laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral characterization of storage phosphor imaging plates

This work presents attenuation and sensitivity measurements of radiographic imaging plates (IPs) with quasimonoenergetic X-rays in the 8–60 kiloelectronvolt range. The measurements are used to validate theoretical predictions. A short overview of the theoretical model is given. The model can be used to describe the sensitivity of different detector types to a wide range of X-ray energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fast microchannel plate-scintillator detector for velocity map imaging and imaging mass spectrometry

The time resolution achievable using standard position-sensitive ion detectors, consisting of a chevron pair of microchannel plates coupled to a phosphor screen, is primarily limited by the emission lifetime of the phosphor, around 70 ns for the most commonly used P47 phosphor. We demonstrate that poly-para-phenylene laser dyes may be employed extremely effectively as scintillators, exhibiting higher brightness and much shorter decay lifetimes than P47. We provide an extensive characterisation of the properties of such scintillators, with a particular emphasis on applications in velocity-map imaging and microscope-mode imaging mass spectrometry. The most promising of the new scintillators exhibits an electron-to-photon conversion efficiency double that of P47, with an emission lifetime an order of magnitude shorter. The new scintillator screens are vacuum stable and show no signs of signal degradation even over longer periods of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel double-plate capacitive proximity sensor modelling based on effective theory

A semi-analytical model for a double-plate capacitive proximity sensor is presented according to the effective theory. Three physical models are established to derive the final equation of the sensor. Measured data are used to determine the coefficients. The final equation is verified by using measured data. The average relative error of the calculated and the measured sensor capacitance is less than 7.5%. The equation can be used to provide guidance to engineering design of the proximity sensors.

36 MATERIALS SCIENCE↗

Note: A timing micro-channel plate detector with backside fast preamplifier

A timing micro-channel plate detector with a backside double-channel fast preamplifier was developed to avoid distortion during signal propagation from the anode to the preamplifier. The mechanical and electronic structure is described. The detector including its backside preamplifier is tested by a {sup 241}Am α-source and a rise time of ∼2 ns with an output background noise of 4 mV{sub rms} was achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation and porosity effects on the magnetohydrodynamic flow near a vertical plate that applies shear stress to the fluid with mass diffusion

This article studies the radiation and porosity effects on the unsteady magnetohydrodynamic free convection flow of an incompressible viscous fluid past an infinite vertical plate that applies a shear stress f(t) to the fluid. Conjugate phenomenon of heat and mass transfer is considered. General solutions of the dimensionless governing equations along with imposed initial and boundary conditions are determined using Laplace transform technique. The solution of velocity is presented as a sum of mechanical and non mechanical parts. These solutions satisfy all imposed initial and boundary conditions and reduce to some known solutions from the literature as special cases. The results for embedded parameters are shown graphically. Numerical results for skin friction, Nusselt number and Sherwood number are computed and presented in tabular forms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond laser surface structuring of silicon using optical vortex beams generated by a q-plate

We report on laser surface structuring of silicon using Ti:Sa femtosecond laser ablation with optical vortex beams. A q-plate is used to generate an optical vortex beam with femtosecond pulse duration through spin-to-orbital conversion of the angular momentum of light. The variation of the produced surface structures is investigated as a function of the number of pulses, N, at laser fluence slightly above the ablation threshold value. At low N (≈10), only surface corrugation of the irradiated, ring-shaped area is observed. This is followed by a progressive formation of regular ripples at larger N (≈100–500), which eventually transform in smaller columnar structures for N ≈ 1000. Moreover, the central, non-ablated part is gradually decorated by nanoparticles produced during laser ablation, a process which eventually leads to the formation of a central turret of assembled nanoparticles. Our experimental findings suggest the importance of a feedback mechanism and a cumulative effect on the formation of ripples with interesting patterns not achievable by the more standard beams with a Gaussian intensity profile.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication of optical multilayer for two-color phase plate in super-resolution microscope

In super-resolution microscopy based on fluorescence depletion, the two-color phase plate (TPP) is an indispensable optical element, which can independently control the phase shifts for two beams of different color, i.e., the pump and erase beams. By controlling a phase shift of the erase beam through the TPP, the erase beam can be modulated into a doughnut shape, while the pump beam maintains the initial Gaussian shape. To obtain a reliable optical multiplayer (ML) for the TPP, we designed a ML with only two optical layers by performing numerical optimization. The measured phase shifts generated by the fabricated ML using interferometry correspond to the design values. The beam profiles in the focal plane are also consistent with theoretical results. Although the fabricated ML consists of only two optical layers, the ML can provide a suitable phase modulation function for the TPP in a practical super-resolution microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved time response for large area microchannel plate photomultiplier tubes in fusion diagnostics

Fusion diagnostics that utilise high speed scintillators often need to capture a large area of light with a high degree of time accuracy. Microchannel plate (MCP) photomultiplier tubes (PMTs) are recognised as the leading device for capturing fast optical signals. However, when manufactured in their traditional proximity focused construction, the time response performance is reduced as the active area increases. This is due to two main factors: the capacitance of a large anode and the difficulty of obtaining small pore MCPs with a large area. Collaboration between Photek and AWE has produced prototype devices that combine the excellent time response of small area MCP-PMTs with a large active area by replacing the traditional proximity-gap front section with an electro-optically focused photocathode to MCP. We present results from both single and double MCP devices with a 40 mm diameter active area and show simulations for the 100 mm device being built this year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers

A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C{sup 6+}, O{sup 8+}, etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparation of magnetized nanodusty plasmas in a radio frequency-driven parallel-plate reactor

Nanodust is produced in an rf-driven push-pull parallel-plate reactor using argon with an acetylene admixture at 5–30 Pa. A scheme for the preparation of nanodust clouds with particle radii up to 400 nm for investigations in magnetized plasmas is proposed. The confinement that keeps the nanodust of different radii inside a moderately magnetized discharge (B ≤ 500 mT) is investigated by a comparison of 2d-Langmuir probe measurements in the dust-free plasma without and with a magnetic field and by the analysis of scattered light of nanodust clouds. It is shown that the dust cloud changes its shape when the dust density changes. This results in a reversed α-γ{sup ′} transition from a dense dust cloud with a central disk-like void to a dilute dust cloud with a toroidal void. When the dust density is further reduced, filaments are observed in the central part of the cloud, which were absent in the high-density phase. It is concluded that the dense nanodust cloud is able to suppress plasma filamentation in magnetized plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High performance techniques for micro channel plate computations in photo multipliers

Monte Carlo - MC methods, requiring heavy computations of large data volume, can be used to predict the amplitude distribution and variance of outputted electron charge in Micro Channel Plates - MCPs, which are fed with primary emitted electrons in their inputs. The concept of parallel and serial combination of separate stages of such stochastic processes, which can be applied in MCP systems and simulated using MC computations, has recently proposed and shown interesting theorems and results. Separating the electron multiplication procedures, occurring in the channels of MCP systems, into sub-procedures, which are similar in nature and occur either in parallel or in consecutive manners, is equivalent to splitting the relevant stochastic system calculations into smaller ones, which can be performed concurrently and/or sequentially. In this way, calculations similar in nature, can be executed only once, thus, eliminating a great percentage of heavy computations. However, when designing and implementing the calculation inferences of the derived theorems using High Performance Computation - HPC techniques, the overall computation cost can further and significantly be reduced. In this paper, the hardware mappings of the relevant theorem inferences onto parallel computing architectures, resulting in circuits of computing blocks for calculation purposes of MCP system stochastic processes, are investigated. Each of the designed and implemented computing circuits corresponds to a theorem inference or to a combination of inferences. The parallelism of the proposed circuits consists of both the concurrent functioning of all the system blocks and of the simultaneous operation of each block, which is processing pieces of data, for many parts of the whole circuit in which it belongs. All the circuits are designed and tested using Altera Quartus II environment and can be implemented as chips, which can be incorporated in computing devices to assist Monte Carlo computations for the estimation of different MCP electron multiplication system performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Determining the detection efficiency of excited neutral atoms by a microchannel plate detector

We present a method for determining the detection efficiency of neutral atoms relative to keV ions. Excited D* atoms are produced by D{sub 2} fragmentation in a strong laser field. The fragments are detected by a micro-channel plate detector either directly as neutrals or as keV ions following field ionization and acceleration by a static electric field. Moreover, we propose a new mechanism by which neutrals are detected. We show that the ratio of the yield of neutrals and ions can be related to the relative detection efficiency of these species.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thin Fresnel zone plate lenses for focusing underwater sound

A Fresnel zone plate (FZP) lens of the Soret type creates a focus by constructive interference of waves diffracted through open annular zones in an opaque screen. For underwater sound below MHz frequencies, a large FZP that blocks sound using high-impedance, dense materials would have practical disadvantages. We experimentally and numerically investigate an alternative approach of creating a FZP with thin (0.4λ) acoustically opaque zones made of soft silicone rubber foam attached to a thin (0.1λ) transparent rubber substrate. An ultra-thin (0.0068λ) FZP that achieves higher gain is also proposed and simulated which uses low-volume fraction, bubble-like resonant air ring cavities to construct opaque zones. Laboratory measurements at 200 kHz indicate that the rubber foam can be accurately modeled as a lossy fluid with an acoustic impedance approximately 1/10 that of water. Measured focal gains up to 20 dB agree with theoretical predictions for normal and oblique incidence. The measured focal radius of 0.68λ (peak-to-null) agrees with the Rayleigh diffraction limit prediction of 0.61 λ/NA (NA = 0.88) for a low-aberration lens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection efficiency of microchannel plates for e{sup −} and π{sup −} in the momentum range from 17.5 to 345 MeV/c

High-energy e{sup –} and π{sup –} were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% ± 0.5% for electrons in the beam momenta range 17.5–300 MeV/c and 6.0% ± 1.3% for pions in the beam momenta range 172–345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter’s magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of imaging plate detector sensitivity to 5-18 MeV electrons

Imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. We calibrated at the ELSA electron beam facility (CEA DIF) the five different available types of IPs (namely, MS-SR-TR-MP-ND) to electrons from 5 to 18 MeV. In the context of diagnostic development for the PETawatt Aquitaine Laser (PETAL), we investigated the use of stacks of IP in order to increase the detection efficiency and get detection response independent from the neighboring materials such as X-ray shielding and detector supports. We also measured fading functions in the time range from a few minutes up to a few days. Finally, our results are systematically compared to GEANT4 simulations in order to provide a complete study of the IP response to electrons over the energy range relevant for PETAL experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗