Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATIENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Performance of advanced trauma life support procedures in microgravity

BACKGROUND: Medical operations on the International Space Station will emphasize the stabilization and transport of critically injured personnel and so will need to be capable of advanced trauma life support (ATLS). METHODS: We evaluated the ATLS invasive procedures in the microgravity environment of parabolic flight using a porcine animal model. Included in the procedures evaluated were artificial ventilation, intravenous infusion, laceration closure, tracheostomy, Foley catheter drainage, chest tube insertion, peritoneal lavage, and the use of telemedicine methods for procedural direction. RESULTS: Artificial ventilation was performed and appeared to be unaltered from the 1-G environment. Intravenous infusion, laceration closure, percutaneous dilational tracheostomy, and Foley catheter drainage were achieved without difficulty. Chest tube insertion and drainage were performed with no more difficulty than in the 1-G environment due to the ability to restrain patient, operator and supplies. A Heimlich valve and Sorenson drainage system were both used to provide for chest tube drainage collection with minimal equipment, without the risk of atmospheric contamination, and with the capability to auto-transfuse blood drained from a hemothorax. The use of telemedicine in chest tube insertion was demonstrated to be useful and feasible. Peritoneal lavage using a percutaneous technique, although requiring less training to perform, was found to be dangerous in weightlessness due to the additional pressure of the bowel on the anterior abdominal wall creating a high risk of bowel perforation. CONCLUSIONS: The performance of ATLS procedures in microgravity appears to be feasible with the exception of diagnostic peritoneal lavage. Minor modifications to equipment and techniques are required in microgravity to effect surgical drainage in the presence of altered fluid dynamics, to prevent atmospheric contamination, and to provide for the restraint requirements. A parabolic simulation system was developed for equipment and procedure verification, physiological research, and possible crew medical officer training in the future.

Parabolic Flight↗

Coping with the diagnostic complexities of the compartment syndrome

This review recognizes that, given the various complexities associated with the condition, no pat answers can be given to fit every patient with the compartment syndrome. The authors first give a definition of the syndrome, together with a brief account of how this self-perpetuating pathologic cycle is triggered. Next, they delineate specific anatomical features of compartments that are likely to be involved, and follow this with an inventory of symptoms and signs to look for in suspected cases. After sorting out the entities that can mimic the compartment syndrome, the authors describe three essential techniques of measuring tissue pressure, which can prove invaluable in diagnosing the compartment syndrome.

NASA Program Biomedical Research↗

[Real time 3D echocardiography]

Three-dimensional representation of the heart is an old concern. Usually, 3D reconstruction of the cardiac mass is made by successive acquisition of 2D sections, the spatial localisation and orientation of which require complex guiding systems. More recently, the concept of volumetric acquisition has been introduced. A matricial emitter-receiver probe complex with parallel data processing provides instantaneous of a pyramidal 64 degrees x 64 degrees volume. The image is restituted in real time and is composed of 3 planes (planes B and C) which can be displaced in all spatial directions at any time during acquisition. The flexibility of this system of acquisition allows volume and mass measurement with greater accuracy and reproducibility, limiting inter-observer variability. Free navigation of the planes of investigation allows reconstruction for qualitative and quantitative analysis of valvular heart disease and other pathologies. Although real time 3D echocardiography is ready for clinical usage, some improvements are still necessary to improve its conviviality. Then real time 3D echocardiography could be the essential tool for understanding, diagnosis and management of patients.

Review↗

Erythropoietin withdrawal alters interactions between young red blood cells, splenic endothelial cells, and macrophages: an in vitro model of neocytolysis

BACKGROUND: We have described the rapid destruction of young red blood cells (neocytolysis) in astronauts adapting to microgravity, in polycythemic high altitude dwellers who descend to sea level, and in patients with kidney disorders. This destruction results from a decrease in erythropoietin (EPO) production. We hypothesized that such EPO withdrawal could trigger physiological changes in cells other than red cell precursors and possibly lead to the uptake and destruction of young red cells by altering endothelial cell-macrophage interactions, most likely occurring in the spleen. METHODS: We identified EPO receptors on human splenic endothelial cells (HSEC) and investigated the responses of these cells to EPO withdrawal. RESULTS: A monolayer of HSEC, unlike human endothelial cells from aorta, glomerulus, or umbilical vein, demonstrated an increase in permeability upon EPO withdrawal that was accompanied by unique morphological changes. When HSEC were cultured with monocyte-derived macrophages (but not when either cell type was cultured alone), EPO withdrawal induced an increased ingestion of young red cells by macrophages when compared with the constant presence or absence of EPO. CONCLUSIONS: HSEC may represent a unique cell type that is able to respond to EPO withdrawal by increasing permeability and interacting with phagocytic macrophages, which leads to neocytolysis.

NASA Discipline Cardiopulmonary↗

Monitoring for neuroprotection. New technologies for the new millennium

Monitoring for neuroprotection, like surgery, has placed on emphasis on minimal or non-invasiveness. Monitoring of parameters that truly reflect the degree of injury to the nervous system is another goal. Thus, two themes for the coming decade in neuromonitoring will be: (1) less-invasive monitoring; and (2) parameters that more closely reflect the etiological factors in ischemic or other neuroinjury. In this paper, we review neuromonitoring techniques and devices that can be used readily in the operating room or intensive care unit setting. Those that require transport of the patient to a special facility (e.g., for computed tomography or magnetic resonance imaging/spectroscopy) and those that have been in standard practice for neuromonitoring (e.g., electrophysiological monitoring--EEG, evoked potentials) are not considered. The two techniques considered in detail are (1) continuous multiparameter local brain tissue monitoring with microprobes, and (2) non-invasive continuous local brain tissue oxygenation monitoring by near infrared spectroscopy. Both techniques have been cleared by the Food and Drug Administration (FDA) for clinical use. The rationale for their use, the nature of the devices, and clinical results to date are reviewed. It is expected that both techniques will gain wide acceptance during the coming decade; further advances in neuromonitoring that can be expected further into the twenty-first century are also discussed.

Review↗

Familial orthostatic tachycardia due to norepinephrine transporter deficiency

Orthostatic intolerance (OI) or postural tachycardia syndrome (POTS) is a syndrome primarily affecting young females, and is characterized by lightheadedness, palpitations, fatigue, altered mentation, and syncope primarily occurring with upright posture and being relieved by lying down. There is typically tachycardia and raised plasma norepinephrine levels on upright posture, but little or no orthostatic hypotension. The pathophysiology of OI is believed to be very heterogeneous. Most studies of the syndrome have focused on abnormalities in norepinephrine release. Here the hypothesis that abnormal norepinephrine transporter (NET) function might contribute to the pathophysiology in some patients with OI was tested. In a proband with significant orthostatic symptoms and tachycardia, disproportionately elevated plasma norepinephrine with standing, impaired systemic, and local clearance of infused tritiated norepinephrine, impaired tyramine responsiveness, and a dissociation between stimulated plasma norepinephrine and DHPG elevation were found. Studies of NET gene structure in the proband revealed a coding mutation that converts a highly conserved transmembrane domain Ala residue to Pro. Analysis of the protein produced by the mutant cDNA in transfected cells demonstrated greater than 98% reduction in activity relative to normal. NE, DHPG/NE, and heart rate correlated with the mutant allele in this family. CONCLUSION: These results represent the first identification of a specific genetic defect in OI and the first disease linked to a coding alteration in a Na+/Cl(-)-dependent neurotransmitter transporter. Identification of this mechanism may facilitate our understanding of genetic causes of OI and lead to the development of more effective therapeutic modalities.

Review, Tutorial↗

Effects of noradrenaline on human vagal baroreflexes

BACKGROUND: Baroreflex sensitivity (BRS) is depressed in conditions associated with high sympathetic nerve activity in proportion to circulating noradrenaline (NA) levels. Despite the prognostic importance of measurements of BRS in patients, there is little information on how high NA levels affect arterial baroreflex function. AIM: To understand better the role of NA in cardiovascular homeostasis. METHODS: We gave incremental intravenous NA infusions (at 50 and 100 ng/kg/min) to 12 healthy young men. We measured RR intervals and photoplethysmographic arterial pressures and estimated BRS with cross-spectral and sequence methods during metronome-guided respiration at 0.25 Hz. RESULTS: The high NA infusion rate significantly increased respiratory-frequency (0.15-0.40 Hz) RR interval spectral power and decreased low-frequency (0.04-0.15 Hz) systolic pressure spectral power compared with baseline levels (P < 0.05 for both). Cross-spectral BRS increased from an average (+/- SD) baseline level of 17.3+/-6.6 to 34.1+/-20.8 ms/mmHg at the high NA infusion rate (P < 0.05). Sequence BRS values did not increase significantly during NA infusions. The percentage of sequences with parallel changes in systolic pressures and RR intervals decreased progressively from a baseline level of 16.0+/-12.9 to 10.1+/-7.4 during the low NA infusion rate and to 6.2+/-6.2% during the high rate (P < 0.05 and 0.01, respectively). CONCLUSIONS: Increases in circulating NA to high physiological levels do not depress BRS but interfere with the close baroreflex-mediated coupling that is usually present between arterial pressure and heart rate.

Non-NASA Center↗

Determining the amount of physical activity needed for long-term weight control

OBJECTIVE: To evaluate prospectively the influence of habitual physical activity on body weight of men and women and to develop a model that defines the role of physical activity on longitudinal weight change. DESIGN AND SETTING: Occupational cohort study conducted for a mean of 5.5 y. SUBJECTS: A total of 496 (341 male and 155 female) NASA/Johnson Space Center employees who completed the 3 month education component of the employee health-related fitness program and remained involved for a minimum of 2 y. MEASUREMENTS: Body weights were measured at baseline (T1) and follow-up (T2), and habitual physical activity was obtained from the mean of multiple ratings of the 11-point (0-10) NASA Activity Scale (NAS) recorded quarterly between T1 and T2. Other measures included age, gender, VO(2 max) obtained from maximal treadmill testing, body mass index (BMI), and body fat percentage. RESULTS: Multiple regression demonstrated that mean NAS, T1 weight, aging and gender all influence long-term T2 weight. T1 age was significant for the men only. Independently, each increase in mean NAS significantly (P<0.01) reduced T2 weight in men (b=-0.91 kg; 95% CI:-1.4 to-0.42 kg) and women (b=-2.14 kg; 95% CI:-2.93 to-1.35 kg). Mean NAS had a greater effect on T2 weight as T1 weight increased, and the relationship was dose-dependent. CONCLUSIONS: Habitual physical activity is a significant source of long-term weight change. The use of self-reported activity level is helpful in predicting long-term weight changes and may be used by health care professionals when counseling patients about the value of physical activity for weight control.

Exercise↗

Orthostatic intolerance and the postural tachycardia syndrome: genetic and environment pathophysiologies. Neurolab Autonomic Team

Orthostatic intolerance is a common problem for inbound space travelers. There is usually tachycardia on standing but blood pressure may be normal, low or, rarely, elevated. This condition is analogous to the orthostatic intolerance that occurs on Earth in individuals with orthostatic tachycardia, palpitations, mitral valve prolapse, and light-headedness. Our studies during the Neurolab mission indicated that sympathetic nerve traffic is raised in microgravity and that plasma norepinephrine is higher than baseline supine levels but lower than baseline upright levels. A subgroup of patients with familial orthostatic intolerance differ from inbound space travelers in that they have an alanine-to-to-proline mutation at amino acid position 457 in their norepinephrine transporter gene. This leads to poor clearance of norepinephrine from synapses, with consequent raised heart rate. Clinical features of these syndromes are presented.

short duration↗

Mitral inertance in humans: critical factor in Doppler estimation of transvalvular pressure gradients

The pressure-velocity relationship across the normal mitral valve is approximated by the Bernoulli equation DeltaP = 1/2 rhoDeltav(2) + M. dv/dt, where DeltaP is the atrioventricular pressure difference, rho is blood density, v is transmitral flow velocity, and M is mitral inertance. Although M is indispensable in assessing transvalvular pressure differences from transmitral flow, this term is poorly understood. We measured intraoperative high-fidelity left atrial and ventricular pressures and simultaneous transmitral flow velocities by using transesophageal echocardiography in 100 beats (8 patients). We computed mean mitral inertance (M) by M = integral((DeltaP)-(1/2 x rho v(2))dt/integral(dv/dt)dt and we assessed the effect of the inertial term on the transmitral pressure-flow relation. ranged from 1.03 to 5.96 g/cm(2) (mean = 3.82 +/- 1.22 g/cm(2)). DeltaP calculated from the simplified Bernoulli equation (DeltaP = 1/2. rhov(2)) lagged behind (44 +/- 11 ms) and underestimated the actual peak pressures (2.3 +/- 1.1 mmHg). correlated with left ventricular systolic pressure (r = -0.68, P < 0.0001) and transmitral pressure gradients (r = 0.65, P < 0.0001). Because mitral inertance causes the velocity to lag significantly behind the actual pressure gradient, it needs to be considered when assessing diastolic filling and the pressure difference across normal mitral valves.

NASA Discipline Cardiopulmonary↗

Late ophthalmological complications after total body irradiation in non-human primates

PURPOSE: To investigate the long-term effects of total body irradiation (TBI) on the incidence and time course of ocular complications. MATERIALS AND METHODS: Rhesus monkeys treated with TBI photon doses up to 8.5 Gy and proton doses up to 7.5 Gy were studied at intervals up to 25 years post-irradiation. They were compared with control groups with a similar age distribution. Cataract formation and ocular fundus lesions were scored according to a standardized protocol. Fluorescein angiography and histopathology was performed in selected animals. RESULTS: Cataract formation occurred after a latent period of 3-5 years. Significant cataract induction was observed for photon-doses of 8 and 8.5 Gy and beyond 20 years after proton irradiation. The severity of the lesions represents significant impairment of vision and would require cataract surgery if similar results occurred in human bone marrow transplant patients. Fluorescein angiography demonstrated a normal pattern of retinal vessels in 13 out of 14 animals (93%) from the irradiated group and in eight out of nine animals (89%) from the control group. No additional lesions apart from age-related degenerative changes could be demonstrated. Histological evaluation revealed no radiation-associated vasculopathy. CONCLUSIONS: Radiation alone for doses up to 8.5 Gy of photons does not carry a potential risk for fundus pathology, whereas clinically important cataract induction should be anticipated within 5 years after photon doses of 8.0 and 8.5 Gy and proton doses in excess of 2.5 Gy.

NASA Discipline Radiation Health↗

Determination of left ventricular volume, ejection fraction, and myocardial mass by real-time three-dimensional echocardiography

Reconstructed three-dimensional (3-D) echocardiography is an accurate and reproducible method of assessing left ventricular (LV) functions. However, it has limitations for clinical study due to the requirement of complex computer and echocardiographic analysis systems, electrocardiographic/respiratory gating, and prolonged imaging times. Real-time 3-D echocardiography has a major advantage of conveniently visualizing the entire cardiac anatomy in three dimensions and of potentially accurately quantifying LV volumes, ejection fractions, and myocardial mass in patients even in the presence of an LV aneurysm. Although the image quality of the current real-time 3-D echocardiographic methods is not optimal, its widespread clinical application is possible because of the convenient and fast image acquisition. We review real-time 3-D echocardiographic image acquisition and quantitative analysis for the evaluation of LV function and LV mass.

NASA Discipline Cardiopulmonary↗

Extracellular calcium sensing and extracellular calcium signaling

The cloning of a G protein-coupled extracellular Ca(2+) (Ca(o)(2+))-sensing receptor (CaR) has elucidated the molecular basis for many of the previously recognized effects of Ca(o)(2+) on tissues that maintain systemic Ca(o)(2+) homeostasis, especially parathyroid chief cells and several cells in the kidney. The availability of the cloned CaR enabled the development of DNA and antibody probes for identifying the CaR's mRNA and protein, respectively, within these and other tissues. It also permitted the identification of human diseases resulting from inactivating or activating mutations of the CaR gene and the subsequent generation of mice with targeted disruption of the CaR gene. The characteristic alterations in parathyroid and renal function in these patients and in the mice with "knockout" of the CaR gene have provided valuable information on the CaR's physiological roles in these tissues participating in mineral ion homeostasis. Nevertheless, relatively little is known about how the CaR regulates other tissues involved in systemic Ca(o)(2+) homeostasis, particularly bone and intestine. Moreover, there is evidence that additional Ca(o)(2+) sensors may exist in bone cells that mediate some or even all of the known effects of Ca(o)(2+) on these cells. Even more remains to be learned about the CaR's function in the rapidly growing list of cells that express it but are uninvolved in systemic Ca(o)(2+) metabolism. Available data suggest that the receptor serves numerous roles outside of systemic mineral ion homeostasis, ranging from the regulation of hormonal secretion and the activities of various ion channels to the longer term control of gene expression, programmed cell death (apoptosis), and cellular proliferation. In some cases, the CaR on these "nonhomeostatic" cells responds to local changes in Ca(o)(2+) taking place within compartments of the extracellular fluid (ECF) that communicate with the outside environment (e.g., the gastrointestinal tract). In others, localized changes in Ca(o)(2+) within the ECF can originate from several mechanisms, including fluxes of calcium ions into or out of cellular or extracellular stores or across epithelium that absorb or secrete Ca(2+). In any event, the CaR and other receptors/sensors for Ca(o)(2+) and probably for other extracellular ions represent versatile regulators of numerous cellular functions and may serve as important therapeutic targets.

Review↗

Ecological study of dietary and smoking links to lymphoma

The ecological approach is used to investigate dietary and smoking links to lymphoma. International mortality rate data for 1986 and 1994 by gender and age group are compared with national dietary supply values of various food components for up to 10 years prior to the mortality data as well as per capita cigarette consumption rates 5 and 15 years earlier. The non-fat portion of milk, 3-9 years prior to the 1986 mortality data and 4 years prior to the 1994 data, was found to have the highest association with lymphoma, with r as high as 0.89. The results imply that 70 percent of lymphoma mortality may be related to this dietary component. Cigarette smoking in 1980 was found to have a weaker association with 1994 lymphoma mortality rates, being most important for younger men and statistically insignificant for younger women. The non-fat milk result is consistent with both case-control studies and a Norwegian prospective study, and with the often-observed finding that abnormal calcium metabolism, hypercalciuria, and dysregulated calcitriol production are common in normocalcemic patients with non-Hodgkin's lymphoma (NHL). It is hypothesized that excess dietary calcium from milk is a significant risk factor for lymphoma.

Calcium/adverse effects↗

Homologous recombination as a potential target for caffeine radiosensitization in mammalian cells: reduced caffeine radiosensitization in XRCC2 and XRCC3 mutants

The radiosensitizing effect of caffeine has been associated with the disruption of multiple DNA damage-responsive cell cycle checkpoints, but several lines of evidence also implicate inhibition of DNA repair. The role of DNA repair inhibition in caffeine radiosensitization remains uncharacterized, and it is unknown which repair process, or lesion, is affected. We show that a radiosensitive cell line, mutant for the RAD51 homolog XRCC2 and defective in homologous recombination repair (HRR), displays significantly diminished caffeine radiosensitization that can be restored by expression of XRCC2. Despite the reduced radiosensitization, caffeine effectively abrogates checkpoints in S and G2 phases in XRCC2 mutant cells indicating that checkpoint abrogation is not sufficient for radiosensitization. Another radiosensitive line, mutant for XRCC3 and defective in HRR, similarly shows reduced caffeine radiosensitization. On the other hand, a radiosensitive mutant (irs-20) of DNA-PKcs with a defect in non-homologous end-joining (NHEJ) is radiosensitized by caffeine to an extent comparable to wild-type cells. In addition, rejoining of radiation-induced DNA DSBs, that mainly reflects NHEJ, remains unaffected by caffeine in XRCC2 and XRCC3 mutants, or their wild-type counterparts. These observations suggest that caffeine targets steps in HRR but not in NHEJ and that abrogation of checkpoint response is not sufficient to explain radiosensitization. Indeed, immortalized fibroblasts from AT patients show caffeine radiosensitization despite the checkpoint defects associated with ATM mutation. We propose that caffeine radiosensitization is mediated by inhibition of stages in DNA DSB repair requiring HRR and that checkpoint disruption contributes by allowing these DSBs to transit into irreparable states. Thus, checkpoints may contribute to genomic stability by promoting error-free HRR.

NASA Discipline Radiation Health↗

Qualitative and quantitative effects of harmonic echocardiographic imaging on endocardial edge definition and side-lobe artifacts

Harmonic imaging is a new ultrasonographic technique that is designed to improve image quality by exploiting the spontaneous generation of higher frequencies as ultrasound propagates through tissue. We studied 51 difficult-to-image patients with blinded side-by-side cineloop evaluation of endocardial border definition by harmonic versus fundamental imaging. In addition, quantitative intensities from cavity versus wall were compared for harmonic versus fundamental imaging. Harmonic imaging improved left ventricular endocardial border delineation over fundamental imaging (superior: harmonic = 71.1%, fundamental = 18.7%; similar: 10.2%; P <.001). Quantitative analysis of 100 wall/cavity combinations demonstrated brighter wall segments and more strikingly darker cavities during harmonic imaging (cavity intensity on a 0 to 255 scale: fundamental = 15.6 +/- 8.6; harmonic = 6.0 +/- 5.3; P <.0001), which led to enhanced contrast between the wall and cavity (1.89 versus 1.19, P <.0001). Harmonic imaging reduces side-lobe artifacts, resulting in a darker cavity and brighter walls, thereby improving image contrast and endocardial delineation.

NASA Discipline Cardiopulmonary↗

Noninvasive estimation of transmitral pressure drop across the normal mitral valve in humans: importance of convective and inertial forces during left ventricular filling

OBJECTIVES: We hypothesized that color M-mode (CMM) images could be used to solve the Euler equation, yielding regional pressure gradients along the scanline, which could then be integrated to yield the unsteady Bernoulli equation and estimate noninvasively both the convective and inertial components of the transmitral pressure difference. BACKGROUND: Pulsed and continuous wave Doppler velocity measurements are routinely used clinically to assess severity of stenotic and regurgitant valves. However, only the convective component of the pressure gradient is measured, thereby neglecting the contribution of inertial forces, which may be significant, particularly for nonstenotic valves. Color M-mode provides a spatiotemporal representation of flow across the mitral valve. METHODS: In eight patients undergoing coronary artery bypass grafting, high-fidelity left atrial and ventricular pressure measurements were obtained synchronously with transmitral CMM digital recordings. The instantaneous diastolic transmitral pressure difference was computed from the M-mode spatiotemporal velocity distribution using the unsteady flow form of the Bernoulli equation and was compared to the catheter measurements. RESULTS: From 56 beats in 16 hemodynamic stages, inclusion of the inertial term ([deltapI]max = 1.78+/-1.30 mm Hg) in the noninvasive pressure difference calculation significantly increased the temporal correlation with catheter-based measurement (r = 0.35+/-0.24 vs. 0.81+/-0.15, p< 0.0001). It also allowed an accurate approximation of the peak pressure difference ([deltapc+I]max = 0.95 [delta(p)cathh]max + 0.24, r = 0.96, p<0.001, error = 0.08+/-0.54 mm Hg). CONCLUSIONS: Inertial forces are significant components of the maximal pressure drop across the normal mitral valve. These can be accurately estimated noninvasively using CMM recordings of transmitral flow, which should improve the understanding of diastolic filling and function of the heart.

Non-NASA Center↗

Interposition vein graft for giant coronary aneurysm repair

Coronary aneurysms in adults are rare. Surgical treatment is often concomitant to treating obstructing coronary lesions. However, the ideal treatment strategy is poorly defined. We present a case of successful treatment of a large coronary artery aneurysm with a reverse saphenous interposition vein graft. This modality offers important benefits over other current surgical and percutaneous techniques and should be considered as an option for patients requiring treatment for coronary aneurysms.

Non-NASA Center↗