Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Organic electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Dipole Moment Calculations Using Multiconfiguration Pair-Density Functional Theory and Hybrid Multiconfiguration Pair-Density Functional Theory

The dipole moment is the molecular property that most directly indicates molecular polarity. The accuracy of computed dipole moments depends strongly on the quality of the calculated electron density, and the breakdown of single-reference methods for strongly correlated systems can lead to poor predictions of the dipole moments in those cases. Here, we derive the analytical expression for obtaining the electric dipole moment by multiconfiguration pair density functional theory (MCPDFT), and we assess the accuracy of MC-PDFT for predicting dipole moments at equilibrium and nonequilibrium geometries. We show that MC-PDFT dipole moment curves have reasonable behavior even for stretched geometries, and they significantly improve upon the CASSCF results by capturing more electron correlation. Herein, the analysis of a dataset consisting of 18 first-row transition metal diatomics and 6 main-group polyatomic molecules with multireference character suggests that MC-PDFT and its hybrid extension (HMC-PDFT) perform comparably to CASPT2 and MRCISD+Q methods and have a mean unsigned deviation of 0.2–0.3 D with respect to the best available dipole moment reference values. We explored the dependence of the predicted dipole moments upon the choice of the on-top density functional and active space, and we recommend the tPBE and hybrid tPBE0 on-top choices for the functionals combined with the moderate correlated participating orbital scheme for selecting the active space. With these choices, the mean unsigned deviations (in debyes) of the calculated equilibrium dipole moments from the best estimates are 0.77 for CASSCF, 0.29 for MC-PDFT, 0.24 for HMCPDFT, 0.28 for CASPT2, and 0.25 for MRCISD+Q. These results are encouraging because the computational cost of MC-PDFT or HMC-PDFT is largely reduced compared to the CASPT2 and MRCISD+Q methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Particle Spectroscopy as a Versatile Tool to Explore Lower-Dimensional Structures of Inorganic Perovskites

The remarkable defect tolerant nature of inorganic cesium halide perovskites leading to near unity photoluminescence (PL) quantum yield (QY) and narrow emission linewidth across the entire visible spectrum, have provided a tantalizing platform for a development of a plethora of light-emitting applications. Recently, lower dimensional (2D, 1D, and 0D) perovskites have attracted further attention due to the enhanced thermal, photo and chemical stability as compared to their three-dimensional (3D) analogues. Combination of the external size quantization and internal octahedral organization provides a unique opportunity to study and harness “multidimensional” electronic properties engineered both on atomic scale and the nanoscale. However, crucial research to understand the elementary charge carrier dynamics in lower dimensional perovskites lags far behind the enormous effort to incorporate them into optoelectronic devices. In this Perspective, we provide a review of recent developments that focus on studies of the dynamics of excitonic complexes in Cs-based perovskite nanocrystals using single-particle time-resolved PL spectroscopy and photon correlation measurements. Single photon statistical studies not only offer the unprecedented level of detail to directly assess various recombination pathways but also provide insights into specifics of carrier’s localization. Further, we discuss the underlying physicochemical processes that govern PL emission and draw attention to a number of attributes within this class of the materials, especially lower-dimensional perovskites that may indicate the common origin of the PL emission, as well as provide a route map for the vast unexplored territories where single particle spectroscopy can be a powerful tool to unravel crucial information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unraveling the mechanism of tip-enhanced molecular energy transfer

Electronic Energy Transfer (EET) between chromophores is fundamental in many natural light-harvesting complexes, serving as a critical step for solar energy funneling in photosynthetic plants and bacteria. The complicated role of the environment in mediating this process in natural architectures has been addressed by recent scanning tunneling microscope experiments involving EET between two molecules supported on a solid substrate. These measurements demonstrated that EET in such conditions has peculiar features, such as a steep dependence on the donor-acceptor distance, reminiscent of a short-range mechanism more than of a Förster-like process. By using state of the art hybrid ab initio/electromagnetic modeling, here we provide a comprehensive theoretical analysis of tip-enhanced EET. In particular, we show that this process can be understood as a complex interplay of electromagnetic-based molecular plasmonic processes, whose result may effectively mimic short range effects. Therefore, the established identification of an exponential decay with Dexter-like effects does not hold for tip-enhanced EET, and accurate electromagnetic modeling is needed to identify the EET mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-Resolved Probing of the Iodobenzene C-Band Using XUV-Induced Electron Transfer Dynamics

Time-resolved extreme ultraviolet spectroscopy was used to investigate photodissociation within the iodobenzene C-band. The carbon–iodine bond of iodobenzene was photolyzed at 200 nm, and the ensuing dynamics were probed at 10.3 nm (120 eV) over a 4 ps range. Two product channels were observed and subsequently isolated by using a global fitting method. Their onset times and energetics were assigned to distinct electron transfer dynamics initiated following site-selective ionization of the iodine photoproducts, enabling the electronic states of the phenyl fragments to be identified using a classical over-the-barrier model for electron transfer. In combination with previous theoretical work, this allowed the corresponding neutral photochemistry to be assigned to (1) dissociation via the 7B2, 8A2, and 8B1 states to give ground-state phenyl, Ph(X), and spin–orbit excited iodine and (2) dissociation through the 7A1 and 8B2 states to give excited-state phenyl, Ph(A), and ground-state iodine. The branching ratio was determined to be 87 ± 4% Ph(X) and 13 ± 4% Ph(A). Similarly, the corresponding amount of energy deposited into the internal phenyl modes in these channels was determined to be 44 ± 10 and 65 ± 21%, respectively, and upper bounds to the channel rise times were found to be 114 ± 6 and 310 ± 60 fs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualizing the Three-Dimensional Arrangement of Hydrogen Atoms in Organic Molecules by Coulomb Explosion Imaging

Structure-sensitive methods based on femtosecond light or electron pulses are now making it possible to measure how molecular structures change during light-induced processes. Despite significant progress, high-fidelity imaging of nuclear positions remains a challenge even for relatively small molecular systems and, notably, regarding the positions of hydrogen atoms. As demonstrated in recent work, X-ray-induced Coulomb explosion imaging (CEI) may overcome this obstacle, as its sensitivity does not depend on the mass of the imaged atoms. The photoinduced ring opening of the heterocyclic molecule 2(5 H )-thiophenone has attracted recent interest. Here, in this work, we show that CEI offers a powerful route to imaging the peripheral H atoms in this molecule and thus, more generally, to tracking detailed nuclear motions (e.g., isomerizations) in organic molecules on ultrafast time scales. Specifically, we record momentum-space Coulomb explosion images that report on the three-dimensional positioning of all nuclei within the molecule, for instance, distinguishing H atoms in C–H bonds that lie within or are directed out of the plane defined by the heavy atoms. The prospect of imaging peripheral H atoms to probe photochemical dynamics is explored by coupling ab initio molecular dynamics with classical Coulomb explosion simulations, thereby differentiating potential photoproduct isomers, including those whose structures primarily differ in the position of the hydrogens.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and methods for organic semiconductor devices with sputtered contact layers

Systems and methods for organic semiconductor devices with sputtered contact layers are provided. In one embodiment, an organic semiconductor device comprises: a first contact layer (140) comprising a first sputter-deposited transparent conducting oxide; an electron transport layer (130) interfacing with the first contact layer; a second contact layer (110) comprising a second sputter-deposited transparent conducting oxide; a hole transport layer interfacing with the second contact layer; and an organic semiconductor active layer (120) having a first side facing the electron transport layer and an opposing second side facing the hole transport layer; wherein either the electron transport layer or the hole transport layer comprises a buffering transport layer.

Hammond, Scott R.↗

Understanding the electron-water interaction at the molecular level: Integrating theory and experiment in the cluster regime

In this final technical report, we summarize our major accomplishments resulting from a combined experimental-theoretical approach that exploits the unique properties of molecular clusters to elucidate how local interactions at the molecular level drive the macroscopic behavior of materials and chemical transformations in liquids. The specific targets for our efforts have need to elucidate how charged entities are accommodated by hydrogen-bonding networks and to establish how the behavior of room temperature ionic liquids can be tailored for specific chemical applications. Because of their central importance in aqueous electrolyte chemistry, we have placed particular emphasis understanding the accommodation of excess electrons and protons by water. These surprisingly complex fundamental electrical charges play a fundamental role in a wide range of chemical and biological processes, and yet even a qualitative picture of their speciation in water and at the air-water interface has proven elusive. The main experimental diagnostic in our approach is to measure and analyze vibrational spectra of temperature and composition controlled molecular aggregates that isolate and amplify the spectral markers for local interactions that are often obscured in measurement on bulk or interfacial water. Our combined experimental-theoretical program has led to a greatly enhanced understanding of the nature of excess electrons and protons in water and in the process developed new and powerful methods of chemical analysis that are currently in use across the chemical sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Manipulating Photoconduction in Cu–Pyrene 1-D Coordination Nanosheets by Modulating Interlayer π–π Stacking

2D conductive metal organic frameworks (MOFs) have become promising candidates for applications in electronic and photoelectronic devices. However, the lack of a fundamental understanding of the charge transport mechanism and synthetic design to alter their conductivity limits their potential applications. In this work, we report the design and synthesis of two 1D Cu–pyrene coordination nanosheets, Cu–pyrene-4,5,9,10 tetrathiol (Cu-PTT) and Cu–2,7-di-tert-butylpyrene-4,5,9,10-tetrathiol (Cu– tBu PTT), as models of 2D conductive MOFs, where the introduction of two different functional groups (H and tert-butyl groups) at the 2 and 7 positions of the PTT ligands is used to tune the interlayer distance and π–π stacking of MOFs. Using optical pump terahertz probe spectroscopy, we show that both nanosheets exhibit appreciable photoconduction, but the photoconduction in Cu– tBu PTT is reduced with respect to that in Cu–PTT, which can be attributed to the larger interlayer distance in the former leading to the decoupling of the interlayer charge transport pathway. Furthermore, these results demonstrate a unique strategy to investigate the impact of out-of-plane extended conjugation on photoconduction in conductive conjugated polymers, MOFs, or coordination nanosheets through adjusting their interlayer spacing.

14 SOLAR ENERGY↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

Comparative Density Functional Theory Study of Magnetic Exchange Couplings in Dinuclear Transition-Metal Complexes

Multicenter transition-metal complexes (MCTMs) with magnetically interacting ions have been proposed as components for information-processing devices and storage units. For any practical application of MCTMs as magnetic units, it is crucial to characterize their magnetic behavior, and in particular, the isotropic magnetic exchange coupling, J, between its magnetic centers. Due to the large size of typical MCTMs, density functional theory is the only practical electronic structure method for evaluating the J coupling. Here, we assess the accuracy of different density functional approximations for predicting the magnetic couplings of eight dinuclear transition-metal complexes, including five dimanganese, two dicopper, and one divanadium with known reliable experimental J couplings spanning from ferromagnetic to strong antiferromagnetic. The density functionals considered include global hybrid functionals which mix semilocal density functional approximations and exact exchange with a fixed admixing parameter, six local hybrid functionals where the admixing parameters are extended to be spatially dependent, the SCAN and r 2 SCAN meta-generalized gradient approximations (GGAs), and two widely used GGAs. We found that global hybrids tested in this work have a tendency to over-correct the error in magnetic coupling parameters from the Perdew–Burke–Ernzerhof (PBE) GGA as seen for manganese complexes. The performance of local hybrid density functionals shows no improvement in terms of bias and is scattered without a clear trend, suggesting that more efforts are needed for the extension from global to local hybrid density functionals for this particular property. The SCAN and r 2 SCAN meta-GGAs are found to perform as well as benchmark global hybrids on most tested complexes. We further analyze the charge density redistribution of meta-GGAs as well as global and local hybrid density functionals with respect to that of PBE, in connection to the self-interaction error or delocalization error.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Cation Insertion on Semiconducting Polymer Thin Films toward Electrochemical Energy Conversion

Semiconducting polymers are being explored for electrochemical and photoelectrochemical energy transformation and storage applications. For these applications, it is critical to understand how ion insertion from the electrolyte into polymer electrodes modulates the polymer electronic structure and electron doping levels. Here, this study explores electrochemical cation insertion in the n-type conjugated redox polymer P90, composed of alternating naphthalene diimide (NDI) acceptor and bithiophene (T2) donor units, where the NDI units are functionalized with heptaethylene glycol (HEG, 90%) and 2-octyl dodecyl (OD, 10%) side chains. By combining in situ techniques (UV-vis absorption and Raman spectroscopies with electrochemistry), structural analysis using ex situ grazing-incidence wide-angle X-ray scattering (GIWAXS), and density functional theory (DFT) calculations, we reveal that dications enable negative polaron and bipolaron formation in the P90 at less reducing potentials while supporting more bipolaron formation than the monocations; moreover, larger dications with smaller hydrated radii increase the maximum P90 electron doping level. We also determine that the monocations lead to more thermodynamically stabilized polarons compared with the dications. These findings highlight the critical role of cation identity in tuning electrochemical charging, charge stabilization, and electronic structure of n-type conjugated redox polymers, providing guidance on the rational design of polymer-based (photo)electrochemical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dissolved Oxygen Redox as the Source of Hydrogen Peroxide and Hydroxyl Radical in Sonicated Emulsive Water Microdroplets

Sonicated emulsive water microdroplets (SEWMs) accelerate and enable a variety of catalyst-free chemical transformations. However, significant unanswered questions remain regarding the chemical intermediates they form and their possible redox origin. In this study, we identified dissolved O 2 as the primary originator of reactive oxygen species (ROS) such as OH• and H 2 O 2. We uncovered the role of dissolved O 2 redox by using a combination of microelectrochemical methods to detect H 2 O 2 , isotopic methods to identify the source of H 2 O 2 , and a combination of electron spin resonance and the DMPO spin trap to detect radicals such as OH•. Notably, we found that H 2 O 2 production is correlated with O 2 content via a reduction pathway enabled by a sufficiently large reducing power that can additionally generate H 2 and even perform Pb electroless deposition on Au and Cu metal substrates. Building on our findings, continuous O 2 bubbling of SEWMs showed accumulation of H 2 O 2 up to ∼88 mM in the aqueous phase within 1 h of sonication, demonstrating the scale-up promise of this method. Distinct to sonochemistry of a single phase, this study advances our understanding of the confluence of redox and chemical reaction mechanisms within SEWMs as a biphasic system. This insight paves the way for improving their reaction kinetics, yield, and selectivity, positioning these attractive redox microreactors as alternatives to traditional electrolyzers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular-Resolution Electron Imaging of Defects and Dynamics at the Ice-Water Interface

Water crystallization into hexagonal ice (type I h ) is one of the most critical processes relevant to the Earth’s environment and human activities. However, despite recent breakthroughs in imaging non-equilibrium condensed ice structures, the ice-water interface has never been imaged at a molecular resolution. This is primarily due to the low stability of the hydrogen bonds in ice under high-resolution microscopy conditions and a lack of methods to prepare compatible samples. Here, this presentation describes the first molecular-resolution imaging of ice crystallized from liquid water and the ice-water interface using high-resolution transmission electron microscopy (HRTEM). By encapsulating deionized (DI) water between two amorphous carbon (a-C) TEM grids and subsequently freezing it with liquid N 2 on a cryo sample stage, we generated two types of ice: non-equilibrium, condensed ice from the atmosphere and encapsulated ice from the DI water (Fig. 1A). Condensed ice usually shows irregular, spherulitic shapes (Fig. 1B). Selected area electron diffraction (SAED) shows that they are a mixture of cubic and hexagonal crystals (Fig. 1C). On the contrary, encapsulated ice forms thin films that contain large-area single-crystalline regions of hexagonal ice oriented along the [0001] zone axis (Fig. 1D). Differential electron energy-loss spectroscopy (EELS) confirmed the high purity of the encapsulated ice free from organic contaminations that are common in other encapsulation methods for HRTEM such as graphene liquid cells. These single-crystalline areas are robust under the electron beam up to ~100 e/Å 2 s. Aberration-corrected HRTEM imaging in these areas achieved a line resolution of ~1.3 Å (Fig. 1E and F). This platform allows us to study near-equilibrium ice structures and dynamics at an unprecedented spatial resolution (Fig. 2). For example, we discovered subdomain-rich regions near the defective crystal edges despite the structure appearing single-crystalline according to diffraction criteria. These subdomains connect via low-angle grain boundaries with flat energy landscapes as a function of tilt angles (according to simulations), showing the high tolerance of ice to defect structures. When we tuned the sample temperature and electron flux rate, we observed radiolysis-controlled bubble generation and dissolution in ice single crystals near a steady state of bubble dynamics. Furthermore, rich beam-induced melting and recrystallization dynamics were observed at the ice-water interface with lattice resolution. These data represent the first observation of the ice-water phase transformation at the sub-nanometer level. In summary, the methods developed in this work enabled molecular-resolution observations of ice and the ice-water interface and shed light on the microstructures and phase transformation pathways. Finer control on the temperature, electron irradiation profile, and imaging detector could eventually lead to real-time observation of ice nucleation in water and address long-standing questions in the nucleation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Use of Liquid Isopropyl Alcohol and Hydrogen Peroxide Gas Plasma to Biologically Decontaminate Spacecraft Electronics

Legitimate concern exists regarding sending spacecraft and their associated hardware to solar system bodies where they could possibly contaminate the body's surface with terrestrial microorganisms. The NASA approved guidelines for sterilization as set forth in NPG 8020.12C, which is consistent with the biological contamination control objectives of the Committee on Space Research (COSPAR), recommends subjecting the spacecraft and its associated hardware to dry heat-a dry heat regimen that could potentially employ a temperature of 110(deg)C for up to 200 hours. Such a temperature exposure could prove detrimental to the spacecraft electronics. The stimulated growth of intermetallic compounds (IMCs) in metallic interconnects and/or thermal degradation of organic materials composing much of the hardware could take place over a prolonged temperature regimen. Such detrimental phenomena would almost certainly compromise the integrity and reliability of the electronics. Investigation of sterilization procedures in the medical field suggests that hydrogen peroxide (H202) gas plasma (HPGP) technology can effectively function as an alternative to heat sterilization, especially for heat-sensitive items. Treatment with isopropyl alcohol (IPA) in liquid form prior to exposure of the hardware to HPGP should also prove beneficial. Although IPA is not a sterilant, it is frequently used as a disinfectant because of its bactericidal properties. The use of IPA in electronics cleaning is widely recognized and has been utilized for many years with no adverse affects reported. In addition, IPA is the principal ingredient of the test fluid used in ionic contamination testers to assess the amount of ionic contamination found on the surfaces of printed wiring assemblies. This paper will set forth experimental data confirming the feasibility of the IPA/H202 approach to reach acceptable microbial reduction (MR) levels of spacecraft electronic hardware. In addition, a proposed process flow in which both IPA liquid and HPGP are utilized will be presented in Section 7.0.

microbial reduction↗

Pu 5f Occupation in Plutonium Dioxide

Herein an actinide N 4,5 branching ratio analysis of PuO 2 and UO 2 has been performed, including measurements with a scanning transmission electron microscope at the Advanced Light Source. It is shown that the 5f occupation of the Pu in plutonium dioxide is n = 5. This is contrary to recent results from another technique.

36 MATERIALS SCIENCE↗

Symmetry dilemmas in quantum computing for chemistry: A comprehensive analysis

Symmetry adaptation, universality, and gate efficiency are central but often competing requirements in quantum algorithms for electronic structure and many-body physics. For example, fully symmetry-adapted universal operator pools typically generate long and deep quantum circuits; gate-efficient universal operator pools generally break symmetries; and gate-efficient, fully symmetry-adapted operator pools may not be universal. In this work, we analyze such symmetry dilemmas both theoretically and numerically. On the theory side, we prove that the popular, gate-efficient operator pool consisting of singlet spin-adapted singles and perfect-pairing doubles is not universal when spatial symmetry is enforced. To demonstrate the strengths and weaknesses of the three types of pools, we perform numerical simulations using an adaptive algorithm paired with operator pools that are (i) fully symmetry-adapted and universal, (ii) fully symmetry-adapted and non-universal, and (iii) breaking a single symmetry and universal. Our numerical simulations encompass three physically relevant scenarios in which the target state is (i) the global ground state, (ii) the ground state crossed by a state differing in multiple symmetry properties, and (iii) the ground state crossed by a state differing in a single symmetry property. Our results show when symmetry-breaking but universal pools can be used safely, when enforcing at least one distinguishing symmetry suffices, and when a particular symmetry must be rigorously preserved to avoid variational collapse. Together, the formal and numerical analyses provide a practical guide for designing and benchmarking symmetry-adapted operator pools that balance universality, resource requirements, and robust state targeting in quantum simulations for chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗