Real-time monitoring of the orthohydrogen fraction in a liquid hydrogen moderator

Here, we present the first direct measurements of the orthohydrogen fraction in an operating liquid hydrogen moderator loop at a high-powered neutron source. We have developed a Raman immersion probe capable of characterizing the orthohydrogen and parahydrogen makeup of a liquid hydrogen loop approximately every ten seconds, which can see orthohydrogen fractions lower than 0.20 without difficulty. At the Spallation Neutron Source, where the time-averaged power deposition in the studied moderator system is around 0.02 W/cm 3 , the orthohydrogen fraction increases with beam power and equilibrates at levels of 0.40 and responds to beam trips in a dynamic fashion. Additionally, we find that without deliberate catalyst systems in place, the relaxation due to the piping in the system has insignificant effect in catalyzing the relaxation of freshly condensed hydrogen toward thermodynamic equilibrium, and that the radiation levels associated with activation in a non-operating spallation neutron source target-moderator-reflector assembly likewise has insignificant effect on the liquid hydrogen kinetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A position and pulse shape discriminant p -terphenyl detector module

We present the development of a neutron detector array module made with para-terphenyl, a bright, fast, n/γ discriminating crystalline organic scintillator. The module is comprised of 2 cm × 2 cm × 2 cm p-terphenyl crystals that have been optically coupled together to create a pseudo-bar module. While only relying on two photo detectors, the module is capable of distinguishing interactions between up to eight crystals. Furthermore, the module retains the p-terphenyl’s pulse shape discrimination (PSD) capability. Together this makes the pseudo-bar module a promising position-sensitive neutron detector. Here we present characteristics of the pseudo-bar module - its timing resolution as well as its pulse shape and position discrimination capabilities, and briefly discuss future plans for utilizing an array of pseudo-bar modules in a useful neutron detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transportable, Low-Dose Active Fast-Neutron Imaging

This document contains a description of the method of transportable, low-dose active fast-neutron imaging as developed by ORNL. The discussion begins with the technique and instrumentation and continues with the image reconstruction and analysis. The analysis discussion includes an example of how a gap smaller than the neutron production spot size and detector size can be detected and characterized depending upon the measurement time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative assessment of neutron flux sensor technologies for advanced reactors

This report documents the comparative assessment of the rhodium-based self-powered neutron detectors (Rh-SPND), micro-pocket fission detectors (MPFD), and dosimetry wires in heated irradiations at the Neutron Radiography reactor facility at Idaho National Laboratory. The sensors performances are evaluated high-temperature environments (upwards of 850°C) during maximum reactor power to simulate use in advanced reactor applications. The performance of the Rh-SPNDs indicates the experiment cartridge heater power supply interferes with the SPND signals. This interference become increasingly significant at temperatures above 500°C with minimal interference observed for temperatures below 500°C. This work also demonstrated the fabrication process for the updated design of the MPFD, but issues related to the seal welds were identified and usable data was limited. Finally, the dosimetry measurements were within the expected range correlated with reactor power; thus, the dosimetry results were used to provide preliminary SPND calibration factors. The results from this experiment serves as a reference for developing and testing of flux sensors that are designed for high-temperature irradiations and advanced reactor deployments. This includes upcoming FY22 irradiations at the Massachusetts Institute of Technology Reactor and the Neutron Radiography (NRAD) reactor utilizing additional fission chambers from Photonis Technologies and fission chambers and SPNDs from The French Alternative Energies and Atomic Energy Commission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comprehensive Study of the Model Mercury-Based Cuprate Superconductors

This is the Final Report on DE-SC0006858, which opened 15 August 2011 and closed 14 August 2017. The Principal Investigator is Martin Greven, School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 555455 (email: greven@umn.edu). The Administrative Point of Contact is Patricia Jondahl, phone: 612-624-5599, email: awards@umn.edu. The DOE Program is the Office of Basic Energy Sciences, Program manager is Dr. P. Thiyagarajan, Neutron Scattering SC-22.2/ Germantown Bldg. (email: Thiyagarajan@science.doe.gov). The chief activity was the crystal growth, characterization, neutron and X-ray scattering study of the mercury-based cuprates, arguably the most desirable high-Tc superconductors for experimental study due to their record values of Tc and their relatively simple crystal structures. It is thought that the unusual magnetic and charge degrees of freedom of the copper-oxygen sheets that form the fundamental building block of all cuprate superconductors give rise to the high Tc and to many other unusual properties exhibited by the class of quantum materials. Neutron scattering experiments were performed to reveal the nature of the magnetic degrees of freedom of the copper-oxygen sheets, whereas X-ray scattering experiments and complementary charge-transport experiments were performed to reveal the nature of the charge degrees of freedom. In addition, collaborations were initiated with experts in the use of complementary experimental techniques. The primary products are (i) scientific articles published in peer-reviewed scientific journals, (ii) scientific presentations at national and international conferences, and (iii) education of postdoctoral researchers, PhD graduate students and undergraduate researchers by providing a research experience in crystal growth, characterization and scattering. Twenty scientific papers were published in peer-reviewed journals, thirty-one invited talks were presented at national or international conferences, or as colloquia or seminars, and three postdoctoral researchers, six PhD graduate students and nine undergraduate researchers were supported wholly or in part in the pursuit of the scientific topics of this award. This report summarizes the activity and productivity, lists highlights, publications and conference presentations, postdocs, students and collaborators. A balance of zero remained at the close of the grant.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Acquisition and Reconstruction for Wavelength-Resolved Neutron Tomography

Wavelength-resolved neutron tomography (WRNT) is an emerging technique for characterizing samples relevant to the materials sciences in 3D. WRNT studies can be carried out at beam lines in spallation neutron or reactor-based user facilities. Because of the limited availability of experimental time, potential imperfections in the neutron source, or constraints placed on the acquisition time by the type of sample, the data can be extremely noisy resulting in tomographic reconstructions with significant artifacts when standard reconstruction algorithms are used. Furthermore, making a full tomographic measurement even with a low signal-to-noise ratio can take several days, resulting in a long wait time before the user can receive feedback from the experiment when traditional acquisition protocols are used. In this paper, we propose an interlaced scanning technique and combine it with a model-based image reconstruction algorithm to produce high-quality WRNT reconstructions concurrent with the measurements being made. The interlaced scan is designed to acquire data so that successive measurements are more diverse in contrast to typical sequential scanning protocols. The model-based reconstruction algorithm combines a data-fidelity term with a regularization term to formulate the wavelength-resolved reconstruction as minimizing a high-dimensional cost-function. Using an experimental dataset of a magnetite sample acquired over a span of about two days, we demonstrate that our technique can produce high-quality reconstructions even during the experiment compared to traditional acquisition and reconstruction techniques. In summary, the combination of the proposed acquisition strategy with an advanced reconstruction algorithm provides a novel guideline for designing WRNT systems at user facilities.

47 OTHER INSTRUMENTATION↗

Advanced Neutron Spectrometer

Energetic neutron measurements remain a challenge for space science investigations and radiation monitoring for human exploration beyond LEO. We are investigating a new composite scintillator design that uses Li6 glass scintillator embedded in a PVT block. A comparison between Li6 and Boron 10 loaded scintillators are being studied to assess the advantages and shortcomings of these two techniques. We present the details of the new Li6 design and results from the comparison of the B10 and Li6 techniques during exposures in a mixed radiation field produced by high energy protons interacting in a target material.

Christl, Mark↗

Goddard's Astrophysics Science Divsion Annual Report 2014

The Astrophysics Science Division (ASD, Code 660) is one of the world's largest and most diverse astronomical organizations. Space flight missions are conceived, built and launched to observe the entire range of the electromagnetic spectrum, from gamma rays to centimeter waves. In addition, experiments are flown to gather data on high-energy cosmic rays, and plans are being made to detect gravitational radiation from space-borne missions. To enable these missions, we have vigorous programs of instrument and detector development. Division scientists also carry out preparatory theoretical work and subsequent data analysis and modeling. In addition to space flight missions, we have a vibrant suborbital program with numerous sounding rocket and balloon payloads in development or operation. The ASD is organized into five labs: the Astroparticle Physics Lab, the X-ray Astrophysics Lab, the Gravitational Astrophysics Lab, the Observational Cosmology Lab, and the Exoplanets and Stellar Astrophysics Lab. The High Energy Astrophysics Science Archive Research Center (HEASARC) is an Office at the Division level. Approximately 400 scientists and engineers work in ASD. Of these, 80 are civil servant scientists, while the rest are resident university-based scientists, contractors, postdoctoral fellows, graduate students, and administrative staff. We currently operate the Swift Explorer mission and the Fermi Gamma-ray Space Telescope. In addition, we provide data archiving and operational support for the XMM mission (jointly with ESA) and the Suzaku mission (with JAXA). We are also a partner with Caltech on the NuSTAR mission. The Hubble Space Telescope Project is headquartered at Goddard, and ASD provides Project Scientists to oversee operations at the Space Telescope Science Institute. Projects in development include the Neutron Interior Composition Explorer (NICER) mission, an X-ray timing experiment for the International Space Station; the Transiting Exoplanet Sky Survey (TESS) Explorer mission, in collaboration with MIT (Ricker, PI); the Soft X-ray Spectrometer (SXS) for the Astro-H mission in collaboration with JAXA, and the James Webb Space Telescope (JWST). The Wide-Field Infrared Survey Telescope (WFIRST), the highest ranked mission in the 2010 decadal survey, is in a pre-phase A study, and we are supplying study scientists for that mission.

Caltech on the NuSTAR mission↗

Evidence of lithium mobility under neutron irradiation

Understanding the evolution of intermetallic materials in high-radiation environments is of great importance for fusion science and national security. Tritium ( 3 H) and lithium ( 6 Li, 7 Li) transport within neutron irradiated claddings coated with aluminide (FeAl3) has been investigated using state-of-the-art multimodal imaging. Specifically, scanning electron microscopy – focused ion beam (SEM-FIB) was used to prepare irradiated coating lift-out samples for follow-on microanalysis. Here, scanning transmission electron microscopy (STEM) was used to acquire atomic-scale information on the carbonaceous structure and elemental mapping. Atomic force microscopy (AFM) was used to determine lift-out dimensions nondestructively. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) spectral and depth profiling show unexpected lithium isotopic distributions in the irradiated cladding, raising an important evidence of possible light isotope mobility within the cladding under elevated temperature and irradiation. ToF-SIMS three-dimensional chemical mappings of mid- and bottom-cladding coatings show light isotopic (e.g., 3 H, 6 Li, 7 Li) distributions in the irradiated coating and give new insights into the fundamental mechanism related to transport mechanisms within the cladding. Multimodal imaging is power to link microstructure, chemistry, and nanoscale defects that impact reliability of these materials. Furthermore, chemical mapping offers observations of the microstructural evolution due to irradiation and provides insights into unexpected material transport under extreme conditions.

36 MATERIALS SCIENCE↗

Probing Li ion dynamics in amorphous xLi 2 SO 4 ∙(1-x)LiPO 3 by quasielastic neutron scattering

The diffusion dynamics of a series of lithium sulfate substituted phosphate glass materials xLi 2 SO 4 ∙(1-x)LiPO 3 has been probed by quasielastic neutron scattering. Amorphous Li ion conductors are attractive as electrolyte materials for all-solid state batteries because they are highly isotropic and chemically stable. Local disorder is expected to reduce barriers to ion migration – leading to improved ionic conductivity relative to their crystalline counterpart – while minimizing unwanted electron transport. We report Li self-diffusion in these materials on a length scale comparable to the interatomic spacings, obtaining values D ≃ 55 ± 4 × 10 -8 cm 2 /s at 450 K. Elastic neutron scattering measurements show an alteration of the phosphate chain backbone of the glass material.

36 MATERIALS SCIENCE↗

First evaluation of fast neutron imaging with LiInSe 2 semiconductors

Fast neutron imaging is a powerful tool to investigate elemental/isotopic compositions of objects, supporting both scientific studies as well as cargo scanning. Current neutron imaging systems are faced with challenges associated with timing, detection efficiency, and/or spatial resolution. Here, we report on the use of a semiconducting lithium indium diselenide neutron sensor coupled to a Timepix ASIC for fast neutron imaging. Using a 15 cm thick copper knife edge, the spatial resolution of the neutron imager was found to be 1.55 mm for 9 MeV neutrons. In conclusion, the experimental detection efficiency at 9 MeV was in general agreement with calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of inertial confinement fusion hot spot properties to the deuterium-tritium fuel adiabat

We determine the dependence of key Inertial Confinement Fusion (ICF) hot spot simulation properties on the deuterium-tritium fuel adiabat, here modified by addition of energy to the cold shell. Variation of this parameter reduces the simulation to experiment discrepancy in some, but not all, experimentally inferred quantities. Using simulations with radiation drives tuned to match experimental shots N120321 and N120405 from the National Ignition Campaign (NIC), we carry out sets of simulations with varying amounts of added entropy and examine the sensitivities of important experimental quantities. Neutron yields, burn widths, hot spot densities, and pressures follow a trend approaching their experimentally inferred quantities. Ion temperatures and areal densities are sensitive to the adiabat changes, but do not necessarily converge to their experimental quantities with the added entropy. This suggests that a modification to the simulation adiabat is one of, but not the only explanation of the observed simulation to experiment discrepancies. In addition, we use a theoretical model to predict 3D mix and observe a slight trend toward less mixing as the entropy is enhanced. Instantaneous quantities are assessed at the time of maximum neutron production, determined dynamically within each simulation. These trends contribute to ICF science, as an effort to understand the NIC simulation to experiment discrepancy, and in their relation to the high foot experiments, which features a higher adiabat in the experimental design and an improved neutron yield in the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spin-orbit excitons in CoO

CoO has an odd number of electrons in its unit cell, and therefore is expected to be metallic. Yet, CoO is strongly insulating owing to significant electronic correlations, thus classifying it as a Mott insulator. We investigate the magnetic fluctuations in CoO using neutron spectroscopy. Here, the strong and spatially far-reaching exchange constants reported recently [P. M. Sarte et al., Phys. Rev. B 98, 024415 (2018)], combined with the single-ion spin-orbit coupling of similar magnitude [R. A. Cowley et al., Phys. Rev. B 88, 205117 (2013)] results in significant mixing between jeff spin-orbit levels in the low-temperature magnetically ordered phase. The high degree of entanglement, combined with the structural domains originating from the Jahn-Teller structural distortion at ~300K, make the magnetic excitation spectrum highly structured in both energy and momentum. We extend previous theoretical work on PrTl 3 [W. J. L. Buyers et al., Phys. Rev. B 11, 266 (1975)] to construct a mean-field and multilevel spin-orbit exciton model employing the aforementioned spin exchange and spin-orbit coupling parameters for coupled Co 2+ ions lying on a rocksalt lattice. This parametrization, based on a tetragonally distorted type-II antiferromagnetic unit cell, captures both the sharp low-energy excitations at the magnetic zone center, and the energy broadened peaks at the zone boundary. However, the model fails to describe the momentum dependence of the excitations at high-energy transfers, where the neutron response decays faster with momentum than the Co 2+ form factor. We discuss such a failure in terms of a possible breakdown of localized spin-orbit excitons at high-energy transfers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Layered shielding design for an active neutron interrogation system

The use of source and detector shields in active neutron interrogation can improve detector signal. In simulations, a shielded detector with a source rotated π/3 rad relative to the opening decreased neutron flux roughly three orders of magnitude. Several realistic source and detector shield configurations were simulated. A layered design reduced neutron and secondary photon flux in the detector by approximately one order of magnitude for a deuterium–tritium source. The shield arrangement can be adapted for a portable, modular design.