Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Exploring the Mineralogy of the Moon with M3

From the initial era or lunar exploration, we have learned that many processes active on the early Moon are common to most terrestrial planets, including the record of early and late impact bombardment. Since most major geologic activity ceased on the Moon approx. 3 Gy ago, the Moon's surface provides a record of the earliest era of terrestrial planet evolution. The type and composition of minerals that comprise a planetary surface are a direct result of the initial composition and subsequent thermal and physical processing. Lunar mineralogy seen today is thus a direct record of the early evolution of the lunar crust and subsequent geologic processes. Specifically, the distribution and concentration of specific minerals is closely tied to magma ocean products, lenses of intruded or remelted plutons, basaltic volcanism and fire-fountaining, and any process (e.g. cratering) that might redistribute or transform primary and secondary lunar crustal materials. The Moon Mineralogy Mapper (M3, or "m-cube") is a state-of-the-art imaging spectrometer that will fly on Chandrayaan-1, the Indian Space Research Organization (ISRO) mission to be launched late 2007 to early 2008. M3 is one of several foreign instruments chosen by ISRO to be flown on Chandrayaan-1 to complement the strong ISRO payload package. M3 was selected through a peer-review process as part of NASA s Discovery Program. It is under the oversight of PI Carle Pieters at Brown University and is being built by an experienced team at the Jet Propulsion Laboratory. Data analysis and calibration are carried out by a highly qualified and knowledgeable Science Team. To characterize diagnostic properties of lunar minerals, M3 acquires high spectral resolution reflectance data from 700 to 3000 nm (optional to 430 nm). M3 operates as a pushbroom spectrometer with a slit oriented orthogonal to the S/C orbital motion. Measurements are obtained simultaneously for 640 cross track spatial elements and 261 spectral elements. This translates to 70 m/pixel spatial resolution from a nominal 100 km polar orbit for Chandrayaan-1 . The primary science goal of M3 is to characterize and map lunar surface mineralogy in the context of its geologic evolution as outlined above. This translates into several sub-topics that focus on exploring the mineral character of the highland crust, characterizing the diversity basaltic volcanism, and identifying potential volatile concentrations near the poles. The primary exploration goal is to assess and map lunar mineral resources at high spatial resolution to support planning for future, targeted missions.

Pieters, C. M.↗

Hierarchically Structured Non-Intrusive Sign Language Recognition

This work presents a hierarchically structured approach at the nonintrusive recognition of sign language from a monocular frontal view. Robustness is achieved through sophisticated localization and tracking methods, including a combined EM/CAMSHIFT overlap resolution procedure and the parallel pursuit of multiple hypotheses about hands position and movement. This allows handling of ambiguities and automatically corrects tracking errors. A biomechanical skeleton model and dynamic motion prediction using Kalman filters represents high level knowledge. Classification is performed by Hidden Markov Models. 152 signs from German sign language were recognized with an accuracy of 97.6%.

Zieren, Jorg↗

Stereo and IMU-Assisted Visual Odometry for Small Robots

This software performs two functions: (1) taking stereo image pairs as input, it computes stereo disparity maps from them by cross-correlation to achieve 3D (three-dimensional) perception; (2) taking a sequence of stereo image pairs as input, it tracks features in the image sequence to estimate the motion of the cameras between successive image pairs. A real-time stereo vision system with IMU (inertial measurement unit)-assisted visual odometry was implemented on a single 750 MHz/520 MHz OMAP3530 SoC (system on chip) from TI (Texas Instruments). Frame rates of 46 fps (frames per second) were achieved at QVGA (Quarter Video Graphics Array i.e. 320 240), or 8 fps at VGA (Video Graphics Array 640 480) resolutions, while simultaneously tracking up to 200 features, taking full advantage of the OMAP3530's integer DSP (digital signal processor) and floating point ARM processors. This is a substantial advancement over previous work as the stereo implementation produces 146 Mde/s (millions of disparities evaluated per second) in 2.5W, yielding a stereo energy efficiency of 58.8 Mde/J, which is 3.75 better than prior DSP stereo while providing more functionality.

Source record↗

NASA's Marshall Space Flight Center Recent Studies and Technology Developments in the Area of SSA/Orbital Debris

NASA/MSFC has been investigating the various aspects of the growing orbital debris problem since early 2009. Data shows that debris ranging in size from 5 mm to 10 cm presents the greatest threat to operational spacecraft today. Therefore, MSFC has focused its efforts on small orbital debris. Using off-the-shelf analysis packages, like the ESA MASTER software, analysts at MSFC have begun to characterize the small debris environment in LEO to support several spacecraft concept studies and hardware test programs addressing the characterization, mitigation, and ultimate removal, if necessary, of small debris. The Small Orbital Debris Active Removal (SODAR) architectural study investigated the overall effectiveness of removing small orbital debris from LEO using a low power, space-based laser. The Small Orbital Debris Detection, Acquisition, and Tracking (SODDAT) conceptual technology demonstration spacecraft was developed to address the challenges of in-situ small orbital debris environment classification including debris observability and instrument requirements for small debris observation. Work is underway at MSFC in the areas of hardware and testing. By combining off the shelf digital video technology, telescope lenses, and advanced video image FPGA processing, MSFC is building a breadboard of a space based, passive orbital tracking camera that can detect and track faint objects (including small debris, satellites, rocket bodies, and NEOs) at ranges of tens to hundreds of kilometers and speeds in excess of 15 km/sec,. MSFC is also sponsoring the development of a one-of-a-kind Dynamic Star Field Simulator with a high resolution large monochrome display and a custom collimator capable of projecting realistic star images with simple orbital debris spots (down to star magnitude 11-12) into a passive orbital detection and tracking system with simulated real-time angular motions of the vehicle mounted sensor. The dynamic star field simulator can be expanded for multiple sensors (including advanced star trackers), real-time vehicle pointing inputs, and more complex orbital debris images. This system is also adaptable to other sensor optics, missions, and installed sensor testing.

Wiegmann, Bruce M.↗

Comparing Pre-Launch Assumptions to In-Flight Navigation Performance of OSIRIS-REx

The Sample Return Capsule (SRC) onboard the NASA Origins, Spectral Inter-pretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx)spacecraft is currently carrying samples of the B-type asteroid Bennu for safe re-turn to Earth at the Utah Test and Training Range on September 24, 2023. These samples were collected during the Touch And Go (TAG) sampling event on October 20, 2020, when the spacecraft contacted the surface for a few seconds at a location less than 1 meter from the target. The unprecedented navigation performance achieved during that event was the culmination of experience gained during two years of cruise and two years of increasingly challenging operation sat Bennu. As we had hoped, the proximity navigation performance at Bennu exceeded pre-launch analysis. This paper will compare the navigation performance through the proximity operation phases to our pre-launch analysis and will quantify how refinements of the small force models governing the spacecraft motion near Bennu considerably improved the down-track state predictions leading up to the successful TAG event. It was evident to the team and to expert peer reviewers during the design phase that exquisite model fidelity and aggressive operational concepts, which challenged and advanced the state of the art for deep space proximity operations, would be required to meet the mission’s objectives. This paper summarizes the superlative achievements of the team in rising to and overcoming these challenges.

Peter G Antresian↗

Simulation and Analysis of Opportunistic MSPA for Multiple Cubesat Deployments

We describe a software approach for simultaneous demodulation and decoding of multiple frequency- multiplexed spacecraft across multiple ground stations. The approach involves the use of a single ground antenna with wide enough aperture to receive multiple angularly adjacent spacecraft simultaneously. This technique uses a wide-band RF signal digitizer coupled with easily and cheaply duplicated software-receiver modules to independently process the frequency-channelized downlink signals from the spacecraft. This approach relaxes the need for realizable modems at each antenna, for example in the Deep-SpaceNetwork (DSN), and can also function as a delayed data retrieval method for cubesat missions with routine science data return. Thus, we hope that this solution can enable more efficient utilization of DSN assets. We concentrate on a simulation similar to the proposed Exploration Mission 1 (EM-1) mission from a geometric perspective. To that end, the simulated scenario involves ten secondary cubesats deployed and tracked for a span of four days (the modeled motion over the first four days of the mission does not include any Trajectory Correction Maneuvers (TCMs) that may be necessary as the cubesats approach the moon). Transmissions from the cubesats may be received through a combination of DSN ground sites based on visibility. The cubesats are assumed to utilize typical cubesat transmit powers and a waveform similar to that of the Iris radio. One cubesat is chosen as the “target” and is considered tracked by all ground-stations throughout the simulation (i.e., it is consistently at the center of the main lobe of each ground station antenna when the ground station is in view of the cubesat in terms of elevation angle). The simulation effort involves synthesizing a wideband signal that includes the ten cubesats across a large bandwidth due to each cubesat having its own center-frequency in X-band, near 8.4 GHz. Each signal is characterized by its own Doppler-frequency shift and free-space path-loss computed through the underlying geometry of the simulation as well as the cubesat transmit power. Finally, each cubesat signal experiences a unique antenna gain at each ground station due to the underlying antenna pattern and spacecraft-ground station geometry. We establish two interesting findings: First, the link-budget for the EM-1-like scenario is almost completely limited by the angle between the center of the antenna main beam and the cubesat, which means that the signal-to-noise ratio is wholly adequate for demodulation and decoding at the simulated bitrates unless the cubesat exits the main beam. Secondly, and fortunately due to the use of a software radio architecture, we show that it is possible to successfully receive signals from most cubesats for the entire 4-day simulation. Due to the signal-to-noise ratio being sufficient for demodulation even after the side-lobe’s 17dB reduction in SNR, the software radio can still demodulate such cubesats as long as the radio is capable of re-establishing carrier lock as the cubesats leave the main beam and enter the side-lobe. Considering that the target application utilizes offline processing, a loss of lock can be detected and lock can be re-established by iterating over the data. Extensive simulations demonstrate these results.

Abraham, Douglas S.↗

The first clinical implementation of electromagnetic transponder-guided MLC tracking

Purpose: We report on the clinical process, quality assurance, and geometric and dosimetric results of the first clinical implementation of electromagnetic transponder-guided MLC tracking which occurred on 28 November 2013 at the Northern Sydney Cancer Centre. Methods: An electromagnetic transponder-based positioning system (Calypso) was modified to send the target position output to in-house-developed MLC tracking code, which adjusts the leaf positions to optimally align the treatment beam with the real-time target position. Clinical process and quality assurance procedures were developed and performed. The first clinical implementation of electromagnetic transponder-guided MLC tracking was for a prostate cancer patient being treated with dual-arc VMAT (RapidArc). For the first fraction of the first patient treatment of electromagnetic transponder-guided MLC tracking we recorded the in-room time and transponder positions, and performed dose reconstruction to estimate the delivered dose and also the dose received had MLC tracking not been used. Results: The total in-room time was 21 min with 2 min of beam delivery. No additional time was needed for MLC tracking and there were no beam holds. The average prostate position from the initial setup was 1.2 mm, mostly an anterior shift. Dose reconstruction analysis of the delivered dose with MLC tracking showed similar isodose and target dose volume histograms to the planned treatment and a 4.6% increase in the fractional rectal V{sub 60}. Dose reconstruction without motion compensation showed a 30% increase in the fractional rectal V{sub 60} from that planned, even for the small motion. Conclusions: The real-time beam-target correction method, electromagnetic transponder-guided MLC tracking, has been translated to the clinic. This achievement represents a milestone in improving geometric and dosimetric accuracy, and by inference treatment outcomes, in cancer radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-209-07: Preliminary Experimental Comparison of Spot- and Continuous Line Scanning with Or Without Rescanning for Gated Proton Therapy

Purpose: We aim to compare the performance of discrete spot- or continuous line scanning combined with rescanning in mitigating residual organ motion during gated proton therapy treatments. Methods: The Quasar respiratory phantom was used to move a 2D scintillation detector on a linear trajectory with sinusoidal motion pattern (sin{sup 4}), 20 mm peak-to-peak amplitude and 5 sec period. Its motion was monitored using a customized solution based on optical tracking technology. We compared spot and line scanning plans for a monoenergetic 150 MeV circular field, 50.4 mm radius at isocenter. Transverse dose distributions at 13 cm depth in PMMA (15.47 mm water equivalent) were measured to compare three options for motion mitigation: rescanning (10× factor), gating and their combination. The gating window was centered in the trajectory plateau to simulate end-exhale gated treatment in presence of 2 mm and 4 mm residual motion, parallel or perpendicular to the primary scanning direction. Results: When the target moves perpendicular to the primary scanning direction, large dose deviations are measured (γ3%/3mm=47%) without mitigation techniques. Beam gating combined with rescanning restores target coverage (γ3%/3mm=91%). For parallel target motion, observed dose distortions in the non-compensated irradiation are smaller (γ3%/3mm=77%). Beam gating alone recovers the 100% gamma pass-rate at 3%/3mm. Continuous line scanning reduces delivery time by up to 60% with respect to discrete spot scanning in presence of motion mitigation, and improves homogeneity when rescanning is applied (up to 20%, perpendicular motion, 4 mm residual motion). Conclusion: The direction of motion has a large impact on the target dose coverage. Nevertheless, even in the worst case scenario, gating combined with rescanning could mitigate the impact of motion on dose deposition. Moreover, continuous line rescanning improves the robustness against residual motion in the gating window. This study has received funding from the European Community’s Seventh Framework Programme (FP7/2007–2013) under grant agreement n.290605 (PSI-FELLOW/COFUND) and ‘Giuliana and Giorgio Stefanini Foundation’.

60 APPLIED LIFE SCIENCES↗

Effect of intrafractional prostate motion on simultaneous boost intensity-modulated radiotherapy to the prostate: A simulation study based on intrafractional motion in the prone position

Although the prostate displacement of patients in the prone position is affected by respiration-induced motion, the effect of intrafractional prostate motion in the prone position during “simultaneous integrated boost intensity-modulated radiotherapy” (SIB-IMRT) is unclear. The purpose of this study was to evaluate the dosimetric effects of intrafractional motion on SIB-IMRT to a dominant intraprostatic lesion (IPL) using measured motion data of patients in a prone position, fixed with a thermoplastic shell. We obtained 2 orthogonal x-ray fluoroscopic images at the same moment every 0.2 seconds for 30 seconds before and after treatment, once weekly, from 7 patients with localized prostate cancer with detectable prostatic calcification. Prostate displacements in the left-right (LR), anteroposterior (AP), and superoinferior (SI) directions were calculated using the prostatic calcification as a fiducial marker. We defined the displacement between pretreatment and posttreatment as baseline drift (BD). An SIB-IMRT plan was generated in which each IPL + 3 mm received a dose of 94.5 Gy, whereas the remainder of the prostate + 7 mm received a dose of 75.6 Gy in 9 fields. A simulated plan of dose blurring was generated by the convolution of isocenter-shifted plans using measured motion data in 30 seconds and motion in 30 seconds + distance between pretreatment and posttreatment position (BD) for each of the 7 patients. The motion in 30 seconds mainly reflected respiration-induced motion. The mean displacements of BD were 1.4 mm (− 3.1 to 8.2 mm), − 2.2 mm (− 9.1 to 1.5 mm), and − 0.3 mm (− 5.0 to 1.8 mm) in the AP, SI, and LR directions, respectively. The differences in the target coverage with V{sub 90%} of the IPL and V{sub 100%} of the prostate between the simulated plan and original plan were − 3.9% to − 0.3% and − 0.6% to 1.1% for respiration-induced motion and 3.1% to − 67.8% and 3.6% to − 13.3% for BD with respiration-induced motion, respectively. The large motion of BD resulted in an inadequate coverage by the prescribed dose of the SIB-IMRT to the IPL. A 7-mm margin is recommended when real-time tracking techniques are not applied. The effect of respiration-induced motion was small, so long as a 3-mm margin was added.

61 RADIATION PROTECTION AND DOSIMETRY↗

THE CONNECTION BETWEEN INTERNETWORK MAGNETIC ELEMENTS AND SUPERGRANULAR FLOWS

The advection of internetwork magnetic elements by supergranular convective flows is investigated using high spatial resolution, high cadence, and high signal-to-noise ratio Na I D1 magnetograms obtained with the Hinode satellite. The observations show that magnetic elements appear everywhere across the quiet Sun surface. We calculate the proper motion of these magnetic elements with the aid of a feature tracking algorithm. The results indicate that magnetic elements appearing in the interior of supergranules tend to drift toward the supergranular boundaries with a non-constant velocity. The azimuthally averaged radial velocities of the magnetic elements and of the supergranular flow, calculated from a local correlation tracking technique applied to Dopplergrams, are very similar. This suggests that, in the long term, surface magnetic elements are advected by supergranular flows, although on short timescales their very chaotic motions are driven mostly by granular flows and other processes.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-D-207A-05: Investigating Sparse-Sampled MRI for Motion Management in Thoracic Radiotherapy

Purpose: Sparse sampling and reconstruction-based MRI techniques represent an attractive strategy to achieve sufficiently high image acquisition speed while maintaining image quality for the task of radiotherapy guidance. In this study, we examine rapid dynamic MRI using a sparse sampling sequence k-t BLAST in capturing motion-induced, cycle-to-cycle variations in tumor position. We investigate the utility of long-term MRI-based motion monitoring as a means of better characterizing respiration-induced tumor motion compared to a single-cycle 4DCT. Methods: An MRI-compatible, programmable, deformable lung motion phantom with eleven 1.5 ml water marker tubes was placed inside a 3.0 T whole-body MR scanner (Philips Ingenia). The phantom was programmed with 10 lung tumor motion traces previously recorded using the Synchrony system. 2D+t image sequences of a coronal slice were acquired using a balanced-SSFP sequence combined with k-t BLAST (accn=3, resolution=0.66×0.66×5 mm3; acquisition time = 110 ms/slice). kV fluoroscopic (ground truth) and 4DCT imaging was performed with the same phantom setup and motion trajectories. Marker positions in all three modalities were segmented and tracked using an opensource deformable image registration package, NiftyReg. Results: Marker trajectories obtained from rapid MRI exhibited <1 mm error compared to kv Fluoro trajectories in the presence of complex motion including baseline shifts and changes in respiratory amplitude, indicating the ability of MRI to monitor motion with adequate geometric fidelity for the purpose of radiotherapy guidance. In contrast, the trajectory derived from 4DCT exhibited significant errors up to 6 mm due to cycle-to-cycle variations and baseline shifts. Consequently, 4DCT was found to underestimate the range of marker motion by as much as 50%. Conclusion: Dynamic MRI is a promising tool for radiotherapy motion management as it permits for longterm, dose-free, soft-tissue-based monitoring of motion, yielding richer and more accurate information about tumor position and motion range compared to the current state-of-the-art, 4DCT. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

Suppression of Biodynamic Interference by Adaptive Filtering

Preliminary experimental results obtained in moving base simulator tests are presented. Both for pursuit and compensatory tracking tasks, a strong deterioration in tracking performance due to biodynamic interference is found. The use of adaptive filtering is shown to substantially alleviate these effects, resulting in a markedly improved tracking performance and reduction in task difficulty. The effect of simulator motion and of adaptive filtering on human operator describing functions is investigated. Adaptive filtering is found to substantially increase pilot gain and cross-over frequency, implying a more tight tracking behavior. The adaptive filter is found to be effective in particular for high-gain proportional dynamics, low display forcing function power and for pursuit tracking task configurations.

Velger, M.↗

Path following using visual odometry for Mars Rover in high-slip environments.

An architecture for autonomous operation of Mars rovers in high slip environments has been designed, implemented, and tested. This architecture is composed of several key technologies that enable the rover to accurately follow a designated path, compensate for slippage, and reach intended goals independent of the terrain over which it is traversing (within the mechanical constraints of the mobility system). These technologies include: visual odometry, full vehicle kinematics, a Kalman filter, and a slop compensation/path follower. Visual odometry tracks distinctive scene features in stereo imagery to estimate rover motion between successively acquired stereo image pairs using a maximum likelihood motion estimation algorithm. The full vehicle kinematics for a rocker-bogie suspension system estimates motion, with a no-slip assumption, by measuring wheel, rates, and rocker, bogie, and steering angles. The Kalman filter merges data from an Inertial Measurement Unit (IMU) and visual odometry. This merged estimate is then compared to the kinematic estimate to determining (tracking into account estimate uncertainties) if and how much slippage has occurred then a slip vector is calculated by differencing the current Kalman filter estimate from the kinematic estimate. This slip vector is then used, in conjunction with the inverse kinematics, to determine the necessary wheel velocities and steering angles to compensate for slip and follow the desired path.

Roumeliotis, Stergios I.↗

Iso-uncertainty control in an experimental fluoroscopy system

Purpose: X-ray fluoroscopy remains an important imaging modality in a number of image-guided procedures due to its real-time nature and excellent spatial detail. However, the radiation dose delivered raises concerns about its use particularly in lengthy treatment procedures (>0.5 h). The authors have previously presented an algorithm that employs feedback of geometric uncertainty to control dose while maintaining a desired targeting uncertainty during fluoroscopic tracking of fiducials. The method was tested using simulations of motion against controlled noise fields. In this paper, the authors embody the previously reported method in a physical prototype and present changes to the controller required to function in a practical setting. Methods: The metric for feedback used in this study is based on the trace of the covariance of the state of the system, tr(C). The state is defined here as the 2D location of a fiducial on a plane parallel to the detector. A relationship between this metric and the tube current is first developed empirically. This relationship is extended to create a manifold that incorporates a latent variable representing the estimated background attenuation. The manifold is then used within the controller to dynamically adjust the tube current and maintain a specified targeting uncertainty. To evaluate the performance of the proposed method, an acrylic sphere (1.6 mm in diameter) was tracked at tube currents ranging from 0.5 to 0.9 mA (0.033 s) at a fixed energy of 80 kVp. The images were acquired on a Varian Paxscan 4030A (2048 × 1536 pixels, ∼100 cm source-to-axis distance, ∼160 cm source-to-detector distance). The sphere was tracked using a particle filter under two background conditions: (1) uniform sheets of acrylic and (2) an acrylic wedge. The measured tr(C) was used in conjunction with a learned manifold to modulate the tube current in order to maintain a specified uncertainty as the sphere traversed regions of varying thickness corresponding to the acrylic sheets in the background. Results: With feedback engaged, the tracking error was found to correlate well with the specified targeting uncertainty. Tracking of the fiducial was found to be robust to changes in the attenuation presented by the varying background conditions. For a desired uncertainty of 5.0 mm, comparison of the feedback framework with a comparable system employing fixed exposure demonstrated dose savings of 29%. Conclusions: This work presents a relation between a state descriptor, tr(C), the x-ray tube current used, and an estimate of the background attenuation. This relation is leveraged to modulate the tube current in order to maintain a desired geometric uncertainty during fluoroscopy. The authors’ work demonstrates the use of the method in a real x-ray fluoroscopy system with physical motion against varying backgrounds. The method offers potential savings in imaging dose to patients and staff while maintaining tracking uncertainty during fluoroscopy-guided treatment procedures.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-04: Simulation of Errors in Maximal Intensity Projection (MIP)-Based Lung Tumor Internal Target Volumes (ITV) Using Real-Time 2D MRI and Deformable Image Registration Based Lung Tumor Tracking

Purpose: To evaluate the effect of inter- and intra-fractional tumor motion on the error in four-dimensional computed tomography (4DCT) maximal intensity projection (MIP)–based lung tumor internal target volumes (ITV), using deformable image registration of real-time 2D-sagital cine-mode MRI acquired during lung SBRT treatments. Methods: Five lung tumor patients underwent free breathing SBRT treatment on the ViewRay, with dose prescribed to PTV (4DCT MIP-based ITV+3–6mm margin). Sagittal slice cine-MR images (3.5×3.5mm pixels) were acquired through the center of the tumor at 4 frames per second throughout the treatments (3–4 fractions of 21–32 minutes duration). Tumor GTVs were contoured on the first frame of the cine and tracked throughout the treatment using off-line optical-flow based deformable registration implemented on a GPU cluster. Pseudo-4DCT MIP-based ITVs were generated from MIPs of the deformed GTV contours limited to short segments of image data. All possible pseudo-4DCT MIP-based ITV volumes were generated with 1s resolution and compared to the ITV volume of the entire treatment course. Varying pseudo-4DCT durations from 10-50s were analyzed. Results: Tumors were covered in their entirety by PTV in the patients analysed here. However, pseudo-4DCT based ITV volumes were observed that were as small as 29% of the entire treatment-ITV, depending on breathing irregularity and the duration of pseudo-4DCT. With an increase in duration of pseudo-4DCT from 10–50s the minimum volume acquired from 95% of all pseudo-4DCTs increased from 62%–81% of the treatment ITV. Conclusion: A 4DCT MIP-based ITV offers a ‘snap-shot’ of breathing motion for the brief period of time the tumor is imaged on a specific day. Real time MRI over prolonged periods of time and over multiple treatment fractions shows that the accuracy of this snap-shot varies according to inter- and intra-fractional tumor motion. Further work is required to investigate the dosimetric effect of these results.

60 APPLIED LIFE SCIENCES↗

Projection-based circular constrained state estimation and fusion over long-haul links

In this paper, we consider a scenario where sensors are deployed over a large geographical area for tracking a target with circular nonlinear constraints on its motion dynamics. The sensor state estimates are sent over long-haul networks to a remote fusion center for fusion. We are interested in different ways to incorporate the constraints into the estimation and fusion process in the presence of communication loss. In particular, we consider closed-form projection-based solutions, including rules for fusing the estimates and for incorporating the constraints, which jointly can guarantee timely fusion often required in realtime systems. We test the performance of these methods in the long-haul tracking environment using a simple example.

Liu, Qiang↗

Broken into Pieces: ATLAS and Aliqa Uma as One Single Stream

We present the first spectroscopic measurements of the ATLAS and Aliqa Uma streams from the Southern Stellar Stream Spectroscopic Survey (S 5), in combination with the photometric data from the Dark Energy Survey and astrometric data from Gaia. From the coherence of spectroscopic members in radial velocity and proper motion, we find that these two systems are extremely likely to be one stream with discontinuity in morphology and density on the sky (the “kink” feature). We refer to this entire stream as the ATLAS-Aliqa Uma stream, or the AAU stream. We perform a comprehensive exploration of the effect of baryonic substructures and find that only an encounter with the Sagittarius dwarf ∼0.5 Gyr ago can create a feature similar to the observed “kink.” In addition, we also identify two gaps in the ATLAS component associated with the broadening in the stream width (the “broadening” feature). These gaps have likely been created by small mass perturbers, such as dark matter halos, as the AAU stream is the most distant cold stream known with severe variations in both the stream surface density and the stream track on the sky. With the stream track, stream distance, and kinematic information, we determine the orbit of the AAU stream and find that it has been affected by the Large Magellanic Cloud, resulting in a misalignment between the proper motion and stream track. Together with the Orphan-Chenab Stream, AAU is the second stream pair that has been found to be a single stream separated into two segments by external perturbation.

79 ASTRONOMY AND ASTROPHYSICS↗

Projection-Based Constrained Fusion Performance with Link Loss and Measurement Bias

Sensor networks have been deployed in many real-world applications for tracking and monitoring of dynamic targets over large geographical areas. We consider a scenario where a number of ground and/or airborne sensors are used to jointly track a ground target with certain constraints on its motion dynamics, such as those defined by roadways. The state estimates from these sensors are sent over a lossy communications network to a remote fusion center for fusion. We propose both centralized and distributed projection-based methods to incorporate known constraints into the estimation and fusion process. In addition to presenting simple closed-form projected fusion solutions, we also show how to utilize knowledge of the constraints into the fusion process by two distance-based weighting methods. Wealso explore the effect of link loss and sensor measurement bias on tracking accuracy performance of constrained fusion using illustrative tracking examples. Performance evaluation results demonstrate the potential of adopting weighted average fusers in improving the overall tracking performance in the presenceof link loss and measurement bias.

Liu, Qiang↗