Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Magnetic properties of two-dimensional nanodots: Ground state and phase transition

We study the effect of perpendicular single-ion anisotropy, −As{sub z}{sup 2}, on the ground-state structure and finite-temperature properties of a two-dimensional magnetic nanodot in presence of a dipolar interaction of strength D. By a simulated annealing Monte Carlo method, we show that in the ground state a vortex core perpendicular to the nanodot plane emerges already in the range of moderate anisotropy values above a certain threshold level. In the giant-anisotropy regime the vortex structure is superseded by a stripe domain structure with stripes of alternate domains perpendicular to the surface of the sample. We have also observed an intermediate stage between the vortex and stripe structures, with satellite regions of tilted nonzero perpendicular magnetization around the core. At finite temperatures, at small A, we show by Monte Carlo simulations that there is a transition from the the in-plane vortex phase to the disordered phase characterized by a peak in the specific heat and the vanishing vortex order parameter. At stronger A, we observe a discontinuous transition with a large latent heat from the in-plane vortex phase to perpendicular stripe ordering phase before a total disordering at higher temperatures. In the regime of perpendicular stripe domains, namely with giant A, there is no phase transition at finite T: the stripe domains are progressively disordered with increasing T. Finite-size effects are shown and discussed.

36 MATERIALS SCIENCE↗

Atomic cascade of K{sup -}p and K{sup -}d atoms and Doppler broadening contribution on x-ray widths

In this article we present a new calculation of the cascade of K{sup -}p and K{sup -}d atoms by the Monte Carlo method. Energy dependence of the collisional cascade processes is taken into account. The x-ray yields due to the radiative transition during the cascade are also calculated. We compare our results with the previous calculations by others and by KEK and DEAR experimental data for K{sup -}p atoms. We have also investigated the kinetic energy distribution of K{sup -}p atoms and the role of Coulomb transition on x-ray yields. Finally, the Doppler broadening contribution on the measured width of x-ray spectra are determined. In order to study the strong interaction in low energies, our results for x-ray yields from K{sup -}p and K{sup -}d atoms can be compared with the forthcoming SIDDHARTA collaboration results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Excitation density distribution in electron-beam-pumped ZnSe semiconductor lasers

The spatial density distribution of the absorbed energy in ZnSe semiconductor lasers excited by electrons with energies from 2 keV to 1 MeV is calculated by the Monte-Carlo method. Approximate analytic expressions determining the absorbed energy of electrons in ZnSe are presented. The pump power threshold in a semiconductor quantum-well ZnSe structure is experimentally determined. The lasing threshold in such structures is estimated as a function of the electron energy. (active media)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and theoretical studies of the spatial distribution of the ionization rate in a non-self-sustained discharge controlled by a fast electron beam

The spatial distribution of the current density of fast electrons and the ionization rate in a gap filled with atmospheric-pressure air under the conditions of a non-self-sustained discharge controlled by a fast electron beam were investigated. The experiments were carried out in a gas-discharge chamber with a grid electrode arranged in parallel to the exit window of the ionization source. Spatial variations in the current density of fast electrons resulting from the grid were measured. The propagation of the electron beam through the discharge system was simulated numerically by the Monte Carlo method in the so-called 'effective collision' approximation. The calculated results agree well with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New particle pusher with hadronic interactions for modeling multimessenger emission from compact objects

We propose novel numerical schemes based on the Boris method in curved spacetime, incorporating both hadronic and radiative interactions for the first time. Once the proton has lost significant energy due to radiative and hadronic losses, and its gyroradius has decreased below typical scales on which the electromagnetic field varies, we apply a guiding center approximation (GCA). We fundamentally simulate collision processes either with a Monte-Carlo method or, where applicable, as a continuous energy loss, contingent on the local optical depth. To test our algorithm for the first time combining the effects of electromagnetic, gravitational, and radiation fields including hadronic interactions, we simulate highly relativistic protons traveling through various electromagnetic fields and proton backgrounds. We provide unit tests in various spatially dependent electromagnetic and gravitational fields and background photon and proton distributions, comparing the trajectory against analytic results. We propose that our method can be used to analyze hadronic interactions in black hole accretion disks, jets, and coronae to study the neutrino abundance from active galactic nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

15 GHz Monitoring of Gamma-ray Blazars with the OVRO 40 Meter Telescope in Support of Fermi

Since mid-2007, we have been monitoring {approx}1200 sources at 15 GHz with the 40 M Telescope at the Owens Valley Radio Observatory. Our sample, mostly blazars, is monitored at least twice per week, yielding densely-sampled light curves. A large fraction of the sources in our sample exhibit significant variation in 15 GHz flux density, enabling variability studies and cross-correlations with other bands. Additionally, many have been detected by the Fermi Gamma-ray Space Telescope. We compare our data with gamma-ray data from Fermi and find a statistically significant flux density correlation after accounting for red shift and selection biases using a new Monte Carlo method. The OVRO program is a part of the F-GAMMA project, which also obtains monthly 2.6-270 GHz radio spectra for a smaller, overlapping blazar sample.

79 ASTRONOMY AND ASTROPHYSICS↗

The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDI{sub vol} to account for differences between scanners

Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI{sub vol} measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI{sub vol} values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI{sub vol} value for those acquisition conditions. Results: CTDI{sub vol} values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDI{sub vol} values, the differences across scanners become very small. For the CTDI{sub vol}, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. Conclusions: This work has revealed that there is considerable variation among modern MDCT scanners in both CTDI{sub vol} and organ dose values. Because these variations are similar, CTDI{sub vol} can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDI{sub vol} to account for the differences between scanners.

61 RADIATION PROTECTION AND DOSIMETRY↗

Charging of submicron structures during silicon dioxide etching in one- and two-frequency gas discharges

A model that combines the Monte Carlo method for calculating electron and ion trajectories in three-dimensional geometry and an analytic approach developed for calculating an electric field in two-dimensional geometry is used to simulate the charging of the surface of periodic submicron SiO{sub 2} structures by electron and ion fluxes in the plasma of a one- and a two-frequency capacitive RF discharge. The energy distribution function of the electrons and ions that come to the bottom of a submicron structure in an argon and an argon-containing plasma is calculated for structures with a width of 11-45 nm and an aspect ratio of d/w = 1-10 (where d and w are the depth and width of the structure). It is shown that secondary electronelectron emission plays an important role in the redistribution of the electric charge and, accordingly, of the electric potential in a submicron structure. It is demonstrated that, when the secondary electron-electron emission mechanism is taken into account, the ion energy spectrum at the bottom of a submicron structure is shifted toward lower energies and becomes broader in comparison with the spectrum of an ion flux from an RF discharge plasma. Moreover, the shift and broadening depend only on the secondary electron-electron emission coefficient, the energy of the charged particles, and the aspect ratio.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of microstructures in radiation fields using a coupled binary-collision Monte Carlo phase field approach

The simulation of radiation effects in materials broadly falls into two categories. At short time and length scales lies the modeling of primary radiation damage, such as point defect creation, energy deposition, and ballistic mixing. This is followed by the modeling at longer time scales of thermally activated microstructure evolution and defect reactions, such as recombination, clustering, and coarsening. The binary collision Monte Carlo method is an established, numerically efficient method for the computation of primary radiation damage. Conversely, the phase field method is a state of the art method for microstructure evolution on longer time and length scales. Here we present a concurrent coupling of these two methods, overcoming the difference between the discrete object Monte Carlo paradigm for primary radiation damage and the continuum field variable approach for microstructure evolution. The coupling is bidirectional, in which the microstructure evolution in the MOOSE finite element frame- work provides the spatial scattering data set for the charged particle trans- port and receives point defect, mass transport, and heat source terms from the simulated collision cascades that contribute to the field variable evolution. The concurrent coupling scheme is implemented in the code Magpie and demonstrated by investigating patterning for a model irradiated immiscible binary alloy. The results from the coupled binary collision Monte Carlo/phase field simulations reproduce the results of analytical models for phase separation, phase mixing, and patterning, supporting the approach and indicating its utility for modeling real materials systems.

36 MATERIALS SCIENCE↗

Statistical mechanical models for dissociative adsorption of O{sub 2} on metal(100) surfaces with blocking, steering, and funneling

We develop statistical mechanical models amenable to analytic treatment for the dissociative adsorption of O{sub 2} at hollow sites on fcc(100) metal surfaces. The models incorporate exclusion of nearest-neighbor pairs of adsorbed O. However, corresponding simple site-blocking models, where adsorption requires a large ensemble of available sites, exhibit an anomalously fast initial decrease in sticking. Thus, in addition to blocking, our models also incorporate more facile adsorption via orientational steering and funneling dynamics (features supported by ab initio Molecular Dynamics studies). Behavior for equilibrated adlayers is distinct from those with finite adspecies mobility. We focus on the low-temperature limited-mobility regime where analysis of the associated master equations readily produces exact results for both short- and long-time behavior. Kinetic Monte Carlo simulation is also utilized to provide a more complete picture of behavior. These models capture both the initial decrease and the saturation of the experimentally observed sticking versus coverage, as well as features of non-equilibrium adlayer ordering as assessed by surface-sensitive diffraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetric study of surface applicators of HDR brachytherapy GammaMed Plus equipment

The cone type surface applicators used in HDR brachytherapy for treatment of small skin lesions are an alternative to be used with both electron beams and orthovoltage X-ray equipment. For a good treatment planning is necessary to know the dose distribution of these applicators, which can be obtained by experimental measurement and Monte Carlo simulation as well. In this study the dose distribution of surface applicators of 3 and 3.5 cm diameter, respectively of HDR brachytherapy GammaMed Plus equipment has been estimated using the Monte Carlo method, MCNP code. The applicators simulated were placed on the surface of a water phantom of 20 × 20 × 20 cm and the dose was calculated at depths from 0 to 3 cm with increments of 0.25 mm. The dose profiles obtained at depth show the expected gradients for surface therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hierarchical Electrode Architectures for Electrical Energy Storage & Conversion

The integration and stability of electrocatalytic nanostructures, which represent one level of porosity in a hierarchical structural scheme when combined with a three-dimensional support scaffold, has been studied using a combination of synthetic processes, characterization techniques, and computational methods. Dendritic platinum nanostructures have been covalently linked to common electrode surfaces using a newly developed chemical route; a chemical route equally applicable to a range of metals, oxides, and semiconductive materials. Characterization of the resulting bound nanostructure system confirms successful binding, while electrochemistry and microscopy demonstrate the viability of these electroactive particles. Scanning tunneling microscopy has been used to image and validate the short-term stability of several electrode-bound platinum dendritic sheet structures toward Oswald ripening. Kinetic Monte Carlo methods have been applied to develop an understanding of the stability of the basic nano-scale porous platinum sheets as they transform from an initial dendrite to hole containing sheets. Alternate synthetic strategies were pursued to grow dendritic platinum structures directly onto subunits (graphitic particles) of the electrode scaffold. A two-step photocatalytic seeding process proved successful at generating desirable nano-scale porous structures. Growth in-place is an alternate strategy to the covalent linking of the electrocatalytic nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations

Purpose: The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a linear accelerator.Methods: In order to properly characterize beams from the integrated kV CBCT system, the authors have adapted a previously developed equivalent source model consisting of an equivalent spectrum module that takes into account intrinsic filtration and an equivalent filter module characterizing the added bowtie filtration. An equivalent spectrum was generated for an 80, 100, and 125 kVp beam with beam energy characterized by half-value layer measurements. An equivalent filter description was generated from bowtie profile measurements for both the full- and half-bowtie. Equivalent source models for each combination of equivalent spectrum and filter were incorporated into the Monte Carlo software package MCNPX. Monte Carlo simulations were then validated against in-phantom measurements for both the radiographic and CBCT mode of operation of the kV CBCT system. Radiographic and CBCT imaging dose was measured for a variety of protocols at various locations within a body (32 cm in diameter) and head (16 cm in diameter) CTDI phantom. The in-phantom radiographic and CBCT dose was simulated at all measurement locations and converted to absolute dose using normalization factors calculated from air scan measurements and corresponding simulations. The simulated results were compared with the physical measurements and their discrepancies were assessed quantitatively.Results: Strong agreement was observed between in-phantom simulations and measurements. For the radiographic protocols, simulations uniformly underestimated measurements by 0.54%–5.14% (mean difference =−3.07%, SD = 1.60%). For the CBCT protocols, simulations uniformly underestimated measurements by 1.35%–5.31% (mean difference =−3.42%, SD = 1.09%).Conclusions: This work demonstrates the feasibility of using a measurement-based kV CBCT source model to facilitate dose calculations with Monte Carlo methods for both the radiographic and CBCT mode of operation. While this initial work validates simulations against measurements for simple geometries, future work will involve utilizing the source model to investigate kV CBCT dosimetry with more complex anthropomorphic phantoms and patient specific models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Classical trajectory Monte Carlo model calculations for ionization of atomic hydrogen by 75-keV proton impact

Cross sections differential with respect to the energy loss and scattering angle of the projectile have been calculated for ionization of atomic hydrogen by 75-keV proton impact using the classical trajectory Monte Carlo method. The results are compared with the experimental data measured by Laforge et al. [Phys. Rev. Lett. 103, 053201 (2009)] and Schulz et al. [Phys. Rev. A 81, 052705 (2010)], as well as with the predictions of several quantum-mechanical theoretical models. The analysis of the deviations between the classical and the quantum-mechanical results shows that the three-body fragmentation dynamics cannot be understood purely classically; for the description of the process the quantum-mechanical treatment of the interplay between the electron-projectile and the projectile-target-nucleus interaction is unavoidable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of high energy photon emissions in laser generated ultra-relativistic plasmas: Real-time synchrotron simulations

We model the emission of high energy photons due to relativistic charged particle motion in intense laser-plasma interactions. This is done within a particle-in-cell code, for which high frequency radiation normally cannot be resolved due to finite time steps and grid size. A simple expression for the synchrotron radiation spectra is used together with a Monte-Carlo method for the emittance. We extend previous work by allowing for arbitrary fields, considering the particles to be in instantaneous circular motion due to an effective magnetic field. Furthermore, we implement noise reduction techniques and present validity estimates of the method. Finally, we perform a rigorous comparison to the mechanism of radiation reaction, and find the emitted energy to be in excellent agreement with the losses calculated using radiation reaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PROBING THE EXPANSION HISTORY OF THE UNIVERSE BY MODEL-INDEPENDENT RECONSTRUCTION FROM SUPERNOVAE AND GAMMA-RAY BURST MEASUREMENTS

To probe the late evolution history of the universe, we adopt two kinds of optimal basis systems. One of them is constructed by performing the principle component analysis, and the other is built by taking the multidimensional scaling approach. Cosmological observables such as the luminosity distance can be decomposed into these basis systems. These basis systems are optimized for different kinds of cosmological models that are based on different physical assumptions, even for a mixture model of them. Therefore, the so-called feature space that is projected from the basis systems is cosmological model independent, and it provides a parameterization for studying and reconstructing the Hubble expansion rate from the supernova luminosity distance and even gamma-ray burst (GRB) data with self-calibration. The circular problem when using GRBs as cosmological candles is naturally eliminated in this procedure. By using the Levenberg–Marquardt technique and the Markov Chain Monte Carlo method, we perform an observational constraint on this kind of parameterization. The data we used include the “joint light-curve analysis” data set that consists of 740 Type Ia supernovae and 109 long GRBs with the well-known Amati relation.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of Individual Atoms in Action

The atomic dynamics of the hole in graphene was simulated via a kinetic monte carlo method. Probabilities for atomic migration, insertion and ejection were determined by ab-initio calculation. The simulation starts with a predefined hole in a graphene sheet. As it proceeds, the hole grows and the atoms along the edge rearrange themselves. The zigzag configuration is found to dominate the armchair one. http://newscenter.lbl.gov/press-releases/2009/03/26/atoms-in-action/

74 ATOMIC AND MOLECULAR PHYSICS↗

Monte Carlo dose enhancement studies in microbeam radiation therapy

Purpose: A radical radiation therapy treatment for gliomas requires extremely high absorbed doses resulting in subsequent deleterious side effects in healthy tissue. Microbeam radiation therapy (MRT) is an innovative technique based on the fact that normal tissue can withstand high radiation doses in small volumes without any significant damage. The synchrotron-generated x-ray beam is collimated and delivered to an array of narrow micrometer-sized planar rectangular fields. Several preclinical experiments performed at the Brookhaven National Laboratory (BNL) and at the European Synchrotron Radiation Facility (ESRF) confirmed that MRT yields a higher therapeutic index than nonsegmented beams of the same characteristics. This index can be greatly improved by loading the tumor with high atomic number (Z) contrast agents. The aim of this work is to find the high-Z element that provides optimum dose enhancement. Methods: Monte Carlo simulations (PENELOPE/penEasy) were performed to assess the peak and valley doses as well as their ratio (PVDR) in healthy tissue and in the tumor, loaded with different contrast agents. The optimization criteria used were maximization of the ratio between the PVDR values in healthy tissue respect to the PVDR in the tumor and minimization of bone and brain valley doses. Results: Dose enhancement factors, PVDR, and valley doses were calculated for different high-Z elements. A significant decrease of PVDR values in the tumor, accompanied by a gain in the valley doses, was found in the presence of high-Z elements. This enables the deposited dose in the healthy tissue to be reduced. The optimum high-Z element depends on the irradiation configuration. As a general trend, the best outcome is provided by the highest Z contrast agents considered, i.e., gold and thallium. However, lanthanides (especially Lu) and hafnium also offer a satisfactory performance. Conclusions: The remarkable therapeutic index in microbeam radiation therapy can be further improved by loading the tumor with a high-Z element. This study reports quantitative data on several dosimetric magnitudes in order to find the optimum contrast agent. Although the final choice of the element will also depend on possible cytotoxicity, three elements were found to be worthy of mention: gold, thallium, and lutetium.

61 RADIATION PROTECTION AND DOSIMETRY↗