Quantum complexity of time evolution with chaotic Hamiltonians

We study the quantum complexity of time evolution in large-N chaotic systems, with the SYK model as our main example. This complexity is expected to increase linearly for exponential time prior to saturating at its maximum value, and is related to the length of minimal geodesics on the manifold of unitary operators that act on Hilbert space. Using the Euler-Arnold formalism, we demonstrate that there is always a geodesic between the identity and the time evolution operator e -iHt whose length grows linearly with time. This geodesic is minimal until there is an obstruction to its minimality, after which it can fail to be a minimum either locally or globally. We identify a criterion — the Eigenstate Complexity Hypothesis (ECH) — which bounds the overlap between offdiagonal energy eigenstate projectors and the k-local operators of the theory, and use it to argue that the linear geodesic will at least be a local minimum for exponential time. We show numerically that the large-N SYK model (which is chaotic) satisfies ECH and thus has no local obstructions to linear growth of complexity for exponential time, as expected from holographic duality. In contrast, we also study the case with N = 2 fermions (which is integrable) and find short-time linear complexity growth followed by oscillations. Our analysis relates complexity to familiar properties of physical theories like their spectra and the structure of energy eigenstates and has implications for the hypothesized computational complexity class separations PSPACE * BQP/poly and PSPACE * BQSUBEXP/subexp, and the “fast-forwarding” of quantum Hamiltonians.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subsystem complexity and holography

As a probe of circuit complexity in holographic field theories, we study sub-system analogues based on the entanglement wedge of the bulk quantities appearing in the “complexity = volume” and “complexity = action” conjectures. We calculate these quantities for one exterior region of an eternal static neutral or charged black hole in general dimensions, dual to a thermal state on one boundary with or without chemical potential respectively, as well as for a shock wave geometry. We then define several analogues of circuit complexity for mixed states, and use tensor networks to gain intuition about them. In the action approach, we find two possible cases depending on an ambiguity in the definition of the action associated with a counterterm. In one case, there is a promising qualitative match between the holographic action and what we call the purification complexity, the minimum number of gates required to prepare an arbitrary purification of the given mixed state. In the other case, the match is to what we call the basis complexity, the minimum number of gates required to prepare the given mixed state starting from a minimal complexity state with the same eigenvalue spectrum. One way to fix this ambiguity is to choose an action definition such that UV divergent part is positive, in which case the best match to the action result is the basis complexity. In contrast, the holographic volume does not appear to match any of our definitions of mixed-state complexity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Axion misalignment driven to the hilltop

The QCD axion serves as a well-motivated dark matter candidate and the misalignment mechanism is known to reproduce the observed abundance with a decay constant $f_a \simeq \mathcal{O}(10^{12})$ GeV for a misalignment angle $\theta_{\rm mis} \simeq \mathcal{O}(1)$. While $f_a \ll 10^{12}$ GeV is of great experimental interest, the misalignment mechanism requires the axion to be very close to the hilltop, i.e. $\theta_{\rm mis} \simeq \pi$. This particular choice of $\theta_{\rm mis}$ has been understood as fine-tuning the initial condition. We offer a dynamical explanation for $\theta_{\rm mis} \simeq \pi$ in a class of models. The axion dynamically relaxes to the minimum of the potential by virtue of an enhanced mass in the early universe. This minimum is subsequently converted to a hilltop because the CP phase of the theory shifts by $\pi$ when one contribution becomes subdominant to another with an opposite sign. We demonstrate explicit and viable examples in supersymmetric models where the higher dimensional Higgs coupling with the inflaton naturally achieves both criteria. Associated phenomenology includes a strikingly sharp prediction of $3 \times 10^9$ GeV $\lesssim f_a \lesssim 10^{10}$ GeV and the absence of isocurvature perturbation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

J/ ψ -hadron correlations at midrapidity in pp collisions at $\sqrt{s}$ = 13 TeV

We report on the measurement of inclusive, non-prompt, and prompt J/ψ-hadron correlations by the ALICE Collaboration at the CERN Large Hadron Collider in pp collisions at a center-of-mass energy of 13 TeV. The correlations are studied at midrapidity (|y| < 0.9) in the transverse momentum ranges p T < 40 GeV/c for the J/ψ and 0.15 < p T < 10 GeV/c and |η| < 0.9 for the associated hadrons. The measurement is based on minimum bias and high multiplicity data samples corresponding to integrated luminosities of L int = 34 nb −1 and L int = 6.9 pb −1 , respectively. In addition, two more data samples are employed, requiring, on top of the minimum bias condition, a threshold on the tower energy of E = 4 and 9 GeV in the ALICE electromagnetic calorimeters, which correspond to integrated luminosities of L int = 0.9 pb −1 and L int = 8.4 pb −1 , respectively. The azimuthally integrated near and away side yields of associated charged hadrons per J/ψ trigger are presented as a function of the J/ψ and associated hadron transverse momentum. The measurements are discussed in comparison to PYTHIA calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced negative energy with a massless Dirac field

Motivated by traversable wormhole constructions that require large amounts of negative energy, we explore constraints on the amount of negative energy that can be carried by a free Dirac field in a slab-shaped region between two parallel spatial planes. Specifically, we ask what is the minimum possible uniform energy density that can exist at some time, considering all possible states and all possibilities for the physics outside the slab. The vacuum state where we identify the two sides of the slab with antiperiodic boundary conditions gives one possible state with uniform negative energy, but we argue that states with more negative energy exist above 1+1 dimensions. Technically, we reduce the problem to studying a massive Dirac field on an interval in 1+1 dimensions and numerically search for states with uniform energy density in a lattice regulated model. We succeed in finding states with enhanced negative energy (relative to the antiperiodic vacuum) which also appear to have a sensible continuum limit. Our results for the mass-dependence of the minimum uniform energy density in 1+1 dimensions suggest that for a 3+1 dimensional massless Dirac fermion, it is possible to have states with arbitrarily large uniform negative energy density in an arbitrarily wide slab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of charged-particle spectra in Pb+Pb collisions at \( \sqrt{s_{\mathrm{NN}}}=2.76 \) TeV with the ATLAS detector at the LHC

Charged-particle spectra obtained in Pb+Pb interactions at \( \sqrt{s_{\mathrm{NN}}}=2.76 \) TeV and pp interactions at \( \sqrt{s_{\mathrm{NN}}}=2.76 \) TeV with the ATLAS detector at the LHC are presented, using data with integrated luminosities of 0.15 nb⁻¹ and 4.2 pb⁻¹, respectively, in a wide transverse momentum (0.5 < p T < 150 GeV) and pseudorapidity (|η| < 2) range. For Pb+Pb collisions, the spectra are presented as a function of collision centrality, which is determined by the response of the forward calorimeters located on both sides of the interaction point. The nuclear modification factors R AA and R CP are presented in detail as a function of centrality, p T and η. They show a distinct p T -dependence with a pronounced minimum at about 7 GeV. Above 60 GeV, R AA is consistent with a plateau at a centrality-dependent value, within the uncertainties. The value is 0.55 ± 0.01(stat.) ± 0.04(syst.) in the most central collisions. The R AA distribution is consistent with flat |η| dependence over the whole transverse momentum range in all centrality classes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

No ν s is Good News

The baryon acoustic oscillation (BAO) analysis from the first year of data from the Dark Energy Spectroscopic Instrument (DESI), when combined with data from the cosmic microwave background (CMB), has placed an upper-limit on the sum of neutrino masses, ∑m ν < 70 meV (95%). In addition to excluding the minimum sum associated with the inverted hierarchy, the posterior is peaked at ∑m ν = 0 and is close to excluding even the minumum sum, 58 meV at 2σ. In this paper, we explore the implications of this data for cosmology and particle physics. The sum of neutrino mass is determined in cosmology from the suppression of clustering in the late universe. Allowing the clustering to be enhanced, we extended the DESI analysis to ∑m ν < 0 and find ∑m ν =160 ± 90 meV (68%), and that the suppression of power from the minimum sum of neutrino masses is excluded at 99% confidence. We show this preference for negative masses makes it challenging to explain the result by a shift of cosmic parameters, such as the optical depth or matter density. We then show how a result of ∑m ν = 0 could arise from new physics in the neutrino sector, including decay, cooling, and/or time-dependent masses. These models are consistent with current observations but imply new physics that is accessible in a wide range of experiments. In addition, we discuss how an apparent signal with ∑m ν < 0 can arise from new long range forces in the dark sector or from a primordial trispectrum that resembles the signal of CMB lensing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Ancillary Information to Improve Hypocenter Estimation: Bayesian Single Event Location (BSEL).

We have developed and tested an algorithm, Bayesian Single Event Location (BSEL), for esti- mating the location of a seismic event. The estimation approach di*ers from established non-linear regression techniques by using a Bayesian prior probability density function (prior PDF) to incor- porate ancillary physical basis constraints about event location. P wave arrival times from seismic events are used in the development. Depth, a focus of this paper, may be modeled with a prior PDF (potentially skewed) that captures physical basis bounds from ancillary event characteristics. For instance the surface wave Rg is present in a waveform only when an event is shallow. A high- condence Rg detection in one or more event waveforms implies a shallow-skewed prior PDF for the depth parameter. This PDF is constructed from a physically-based Rayleigh wave depth excitation eigenfunction that is based on the minimum period of observation from a spectrogram analysis and estimated near-source elastic parameters. The proposed Bayesian algorithm is illustrated with events that demonstrate its congruity with established hypocenter estimation methods and its application potential. The BSEL method is applied to the Mw 5.6 Dillon, MT earthquake of July 26, 2005 and a shallow Mw 4 earthquake that occurred near Bardwell, KY on June 6, 2003. In both cases we simulate BSEL on a small subset of arrival time data to illustrate the power of the technique. No Rg was actually observed for the Dillon, MT earthquake, but we used the minimum observed period of a Rayleigh wave (7 seconds) to reduce the depth and origin time uncertainty. A strong Rg was observed from the Bardwell, KY earthquake that places very strong constraints on depth and origin time.

58 GEOSCIENCES↗

Influence of Surgical Staples on Radiofrequency Ablation Using Multitined Expandable Electrodes

Purpose. During radiofrequency ablation (RFA), there is a risk that the multitined expandable electrode will come into contact with one of the surgical staples used to treat local recurrence after surgical operations. Our objective was to evaluate whether a surgical staple would influence the RFA of egg white using a multitined expandable electrode. Methods. Multitined expandable electrodes, LeVeen needles (expandable diameter 3.0 cm), were sunk into an egg white bath with (a) no surgical staple, (b) a surgical staple touching one of the tines, or (c) a surgical staple touching two of the tines simultaneously. By connecting the LeVeen needle and copper plate at the bottom of the bath, RFA was then performed on the egg whites as a substitute for human tissue. Ten egg white baths were ablated under each of conditions (a), (b), and (c), for a total of 30 sets of coagulated egg white. Results. There was no significant difference in the time from the power-on to the roll-off (i.e., the completion and shutting off of the electric circuit) or in the maximum diameter of the thermal lesion between conditions (a) and (b) or (a) and (c). However, the minimum diameter of the thermal lesion was significantly smaller in (c) compared with (a) (p < 0.01). Conclusions. Surgical staples have the capacity to interfere with the electromagnetic field and decrease the minimum diameter of the thermal lesion in the event that a staple touches two of the tines of a multitined expandable electrode during RFA. Although the difference might be small enough to be neglected under many clinical circumstances, we recommend that, if possible, the tines not be expanded near metallic material.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Detection of Therapeutic Response to Hepatic Arterial Infusion Chemotherapy of Liver Metastases from Colorectal Cancer Using Diffusion-Weighted MR Imaging

The purpose of this study was to investigate whether diffusion-weighted magnetic resonance imaging (DWI) is useful for early detection of the response of hepatic colorectal metastases to hepatic arterial infusion chemotherapy (HAIC) with 5-fluorouracil (5-FU). The subjects were 12 patients with hepatic colorectal metastases. The indwelling catheter for HAIC was placed in the hepatic artery, and 1000 mg/m{sup 2} 5-FU was given repeatedly once a week. DWI was performed before and 9 days after HAIC. The minimum and mean apparent diffusion coefficient (ADC) values (minADC and meanADC) were measured. The relative change in ADC values (%ADC) and the relative change in tumor size on follow-up CT after 3 months (reduction ratio) were determined. Liver metastases were divided into two groups, responder and nonresponder. The correlation between %ADC and reduction ratio was determined, and %ADC was compared between the two groups. Eleven patients successfully completed HAIC over the 3-month period; 48 metastatic lesions were evaluated. Positive correlations were observed for relative change between %minADC and reduction ratio (r = 0.709) and between %meanADC and reduction ratio (r = 0.536). Both %minADC and %meanADC were significantly greater in the responder group than in the nonresponder group. With the threshold determined as < 3.5%, the receiver-operating curve analysis showed higher sensitivity and specificity values for %minADC (100% and 92.6%, respectively) than for %meanADC (66.7% and 74.1%, respectively). In conclusion, the relative change in minimum ADC values on DWI may be useful for early detection of the response of liver metastases to HAIC with 5-FU.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Current Combined With Bipolar Radiofrequency Ablation: An Ex Vivo Feasibility Study

The combination of radiofrequency ablation (RFA) with direct current (DC) is a promising strategy to improve the efficiency of RFA. However, DC-enhanced monopolar RFA is limited by electrolytic injury at the positive-electrode site. The aim of this study was to investigate the feasibility of the DC-enhanced bipolar RFA. To obviate the need for the subcutaneous positive electrode, the DC circuit was combined with a commercially available bipolar RFA system, in which both poles of the DC circuit are connected to a single RF probe. DC was applied for 15 min and followed by RFA in bovine livers using the following various DC currents: (1) no DC (control), (2) 3V continued until the end of RFA, (3) 5V continued until the end of RFA, (4) 10V continued until the end of RFA, (5) 5V continued in the circuit with reversed pole, (6) 3V stopped after initiation of RFA, and (7) 5V stopped. Coagulation volume, temperatures at a distance of 5, 10, and 15 mm from the RF probe, mean amperage, ablation duration, applied energy, minimum impedance, and degree of tissue charring were assessed and compared (analysis of variance, Student-Newman-Keuls test). All combined DC and RFA groups did increase coagulation volume. The 10V continued group showed significantly lower applied energy, shortest ablation duration, highest minimum impedance, and highest degree of charring with the lowest coagulation volume (p < 0.05). DC-enhanced bipolar RFA with both poles of the DC circuit on a single probe appears to be ineffective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment in Emergency Setting of Acute Arterial Injuries After Orthopedic Surgery

Purpose: To assess the feasibility and effectiveness of emergency endovascular treatment of acute arterial injuries after orthopedic surgery. Materials and Methods: Fifteen patients (mean age 68.3 years) with acute arterial injuries after orthopedic surgery were observed, in particular, 5 patients with pseudoaneurysm, 9 patients with active bleeding, and 1 patient with arterial dissection. Transarterial embolization (TAE) and positioning of covered and noncovered stents were the treatments performed. Follow-up after stent implantation (mean 36 months) was performed with color Doppler US (CDU) at 1, 3, 6, and 12 months and yearly thereafter. Plain X-ray was performed to evidence dislodgment or fracture of the graft. A minimum of 12 months' follow-up is available after TAE. Results: Immediate technical success was obtained in all cases. No major complications occurred. Overall clinical success rate was 100%. During mean follow-up, stent-graft occlusions did not occurred. No recurrence and/or consequence of TAE was registered during a minimum follow-up of 12 months. Conclusions: Percutaneous treatment is a feasible and safe tool for treating arterial injuries because it can provide fast and definitive resolution of the damage. This low-invasiveness approach can be proposed as first-line treatment in patients with acute injuries after orthopedic surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of the Nonlethal Margin Inside the Visible 'Ice-Ball' During Percutaneous Cryoablation of Renal Tissue

Objective. The study was designed to determine the distance between the visible 'ice-ball' and the lethal temperature isotherm for normal renal tissue during cryoablation. Methods. The Animal Care Committee approved the study. Nine adult swine were used: three to determine the optimum tissue stain and six to test the hypotheses. They were anesthetized and the left renal artery was catheterized under fluoroscopy. Under MR guidance, the kidney was ablated and (at end of a complete ablation) the nonfrozen renal tissue (surrounding the 'ice-ball') was stained via renal artery catheter. Kidneys were explanted and sent for slide preparation and examination. From each slide, we measured the maximum, minimum, and an in-between distance from the stained to the lethal tissue boundaries (margin). We examined each slide for evidence of 'heat pump' effect. Results. A total of 126 measurements of the margin (visible 'ice-ball'-lethal margin) were made. These measurements were obtained from 29 slides prepared from the 6 test animals. Mean width was 0.75 {+-} 0.44 mm (maximum 1.15 {+-} 0.51 mm). It was found to increase adjacent to large blood vessels. No 'heat pump' effect was noted within the lethal zone. Data are limited to normal swine renal tissue. Conclusions. Considering the effects of the 'heat pump' phenomenon for normal renal tissue, the margin was measured to be 1.15 {+-} 0.51 mm. To approximate the efficacy of the 'gold standard' (partial nephrectomy, {approx}98 %), a minimum margin of 3 mm is recommended (3 Multiplication-Sign SD). Given these assumptions and extrapolating for renal cancer, which reportedly is more cryoresistant with a lethal temperature of -40 Degree-Sign C, the recommended margin is 6 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Convergence analysis for a nonlocal gradient descent method via directional Gaussian smoothing

We analyze the convergence of a nonlocal gradient descent method for minimizing a class of high-dimensional non-convex functions, where a directional Gaussian smoothing (DGS) is proposed to define the nonlocal gradient (also referred to as the DGS gradient). The method was first proposed in [Zhang et al., Enabling long-range exploration in minimization of multimodal functions, UAI 2021], in which multiple numerical experiments showed that replacing the traditional local gradient with the DGS gradient can help the optimizers escape local minima more easily and significantly improve their performance. However, a rigorous theory for the efficiency of the method on nonconvex landscape is lacking. In this work, we investigate the scenario where the objective function is composed of a convex function, perturbed by deterministic oscillating noise. We provide a convergence theory under which the iterates exponentially converge to a tightened neighborhood of the solution, whose size is characterized by the noise wavelength. Here, we also establish a correlation between the optimal values of the Gaussian smoothing radius and the noise wavelength, thus justifying the advantage of using moderate or large smoothing radii with the method. Furthermore, if the noise level decays to zero when approaching the global minimum, we prove that DGS-based optimization converges to the exact global minimum with linear rates, similarly to standard gradient-based methods in optimizing convex functions. Several numerical experiments are provided to confirm our theory and illustrate the superiority of the approach over those based on the local gradient.

Tran, Hoang [Oak Ridge National Laboratory (ORNL),↗

Interpreting test temperature and loading rate effects on the fracture toughness of polymer-metal interfaces via time–temperature superposition

Here, in this letter, we present interfacial fracture toughness data for a polymer-metal interface where tests were conducted at various test temperatures T and loading rates $\dot{δ}$. An adhesively bonded asymmetric double cantilever beam (ADCB) specimen was utilized to measure toughness. ADCB specimens were created by bonding a thinner, upper adherend to a thicker, lower adherend (both 6061 T6 aluminum) using a thin layer of epoxy adhesive, such that the crack propagated along the interface between the thinner adherend and the epoxy layer. The specimens were tested at T from 25 to 65 °C and $\dot{δ}$ from 0.002 to 0.2 mm/s. The measured interfacial toughness Γ increased as both T and $\dot{δ}$ increased. For an ADCB specimen loaded at a constant $\dot{δ}$, the energy release rate G increases as the crack length a increases. For this reason, we defined rate effects in terms of the rate of change in the energy release rate $\dot{G}$. Although not rigorously correct, a formal application of time–temperature superposition (TTS) analysis to the Γ data provided useful insights on the observed dependencies. In the TTS-shifted data, Γ decreased and then increased for monotonically increasing $\dot{G}$. Thus, the TTS analysis suggests that there is a minimum value of Γ. This minimum value could be used to define a lower bound in Γ when designing critical engineering applications that are subjected to T and $\dot{δ}$ excursions.

36 MATERIALS SCIENCE↗

Thermodynamic stabilization of nanocrystalline aluminum

Nanocrystalline metals are generally unstable due to a large volume fraction of high-energy grain boundaries associated with a small grain size. Preferential dopant segregation to the high-energy grain boundaries is observed to enhance the stability of the material’s microstructure by minimizing its energy. Nanocrystalline aluminum-dopant systems were evaluated for thermodynamic stability against grain growth and phase precipitation via the mechanism of grain boundary segregation according to a modified regular nanocrystalline solution model. Fifty-one potential dopant elements have been evaluated for their efficacy in stabilizing nanostructures with three potential candidates, magnesium, lanthanum, and silicon, identified possessing the characteristics to promote grain boundary segregation and a state of thermodynamic stability in aluminum’s nanocrystalline regime. Here, the minimum dopant content required to achieve nanocrystalline microstructure stability is identified for each of the three candidate elements. Beyond this minimum content, further addition of the dopant elements decreased the final microstructure’s stability with no effects on the existence of a stable nanocrystalline state.

36 MATERIALS SCIENCE↗

Particle–Hole Asymmetry and the Pseudogap Phase of the High-TC Superconductors

In the pseudogap phase of the copper oxide superconductors, a significant portion of the Fermi surface is still gapped at temperatures above the superconducting transition temperature T{sub C}. Instead of a closed Fermi surface, the low-energy electronic excitations appear to form unconnected Fermi arcs separated by gapped regions. It is generally believed that the spectral function is particle-hole symmetric (at low energies) in both regions - with a peak at the Fermi level on the Fermi arcs and a local minimum at the Fermi level in the gapped regions. Here, using high resolution angle-resolved photoemission and new techniques of analysis, we show that on a sizable portion of the Fermi surface, the electronic structure in the immediate vicinity of the Fermi level is not particle-hole symmetric in the pseudogap phase. This is clear evidence that an alternative ground state competes with the superconductivity. The observations are also consistent with the possibility that the Fermi arcs are, in fact, the inner surface of the predicted Fermi pockets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗