Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Measurement of Muon Neutrino Quasielastic Scattering on a Hydrocarbon Target at E ν ~3.5 GeV

We report a study of ν μ charged-current quasielastic events in the segmented scintillator inner tracker of the MINERvA experiment running in the NuMI neutrino beam at Fermilab. The events were selected by requiring a μ⁻ and low calorimetric recoil energy separated from the interaction vertex. We measure the flux-averaged differential cross section, dσ/dQ², and study the low energy particle content of the final state. Deviations are found between the measured dσ/dQ² and the expectations of a model of independent nucleons in a relativistic Fermi gas. We also observe an excess of energy near the vertex consistent with multiple protons in the final state.

Fiorentini, G. A.↗

Measurements of Four-Lepton Production at the Z Resonance in p p Collisions at s = 7 and 8 TeV with ATLAS

Measurements of four-lepton (4,$\ell$,$\ell$=$e,μ$) production cross sections at the Z resonance in pp collisions at the LHC with the ATLAS detector are presented. For dilepton and four-lepton invariant mass regions m &ell;+&ell;- >5 GeV and 80 < m 4&ell; < 100 Gev, the measured cross sections are 76 ± 18(stat) ±4 (syst) ±1.4(lumi) fb and 107 ±9 (stat) ±4 (syst) ±3.0(lumi) fb at $ \sqrt{s} $ = 7 and 8 Tev, respectively. By subtracting the nonresonant 4&ell; production contributions and normalizing with Z→μ + μ - events, the branching fraction for the Z boson decay to 4&ell; is determined to be (3.20±0.25(stat)±0.13(syst))×10 -6 , consistent with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the ZZ Production Cross Section in $pp$ Collisions at $\sqrt{s}$ = 13 TeV with the ATLAS Detector

The ZZ production cross section in proton-proton collisions at 13 TeV center-of-mass energy is measured using 3.2 fb$^{-1}$ of data recorded with the ATLAS detector at the Large Hadron Collider. The considered Z boson candidates decay to an electron or muon pair of mass 66-116 GeV. The cross section is measured in a fiducial phase space reflecting the detector acceptance. It is also extrapolated to a total phase space for Z bosons in the same mass range and of all decay modes, giving $16.7^{+2.2}_{-2.0}$(stat)$ ^{+0.9}_{-0.7}$(syst)$ ^{+1.0}_{-0.7}$(lumi) pb. The results agree with standard model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct lifetime measurements of the excited states in Ni 72

The lifetimes of the first excited 2 + and 4 + states in 72 Ni were measured at the National Superconducting Cyclotron Laboratory with the recoil-distance Doppler-shift method, a model-independent probe to obtain the reduced transition probability. Excited states in 72 Ni were populated by the one-proton knockout reaction of an intermediate energy 73 Cu beam. γ-ray-recoil coincidences were detected with the γ-ray tracking array GRETINA and the S800 spectrograph. Our results provide evidence of enhanced transition probability B(E2;2 + → 0 + ) as compared to 68 Ni, but do not confirm the trend of large B(E2) values reported in the neighboring isotope 70 Ni obtained from Coulomb excitation measurement. The results are compared to shell model calculations. Here, the lifetime obtained for the excited 4 + 1 state is consistent with models showing decay of a seniority ν = 4, 4 + state, which is consistent with the disappearance of the 8+ isomer in 72 Ni.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of Two Excited Bc+ States and Measurement of the Bc+ (2S) Mass in pp Collisions at s =13 TeV

Signals consistent with the Bc+(2S) and Bc∗+(2S) states are observed in proton-proton collisions at s=13 TeV, in an event sample corresponding to an integrated luminosity of 143 fb-1, collected by the CMS experiment during the 2015-2018 LHC running periods. These excited bc states are observed in the Bc+π+π- invariant mass spectrum, with the ground state Bc+ reconstructed through its decay to J/ψπ+. The two states are reconstructed as two well-resolved peaks, separated in mass by 29.1±1.5(stat)±0.7(syst) MeV. The observation of two peaks, rather than one, is established with a significance exceeding five standard deviations. The mass of the Bc+(2S) meson is measured to be 6871.0±1.2(stat)±0.8(syst)±0.8(Bc+) MeV, where the last term corresponds to the uncertainty in the world-average Bc+ mass. © 2019 CERN for the CMS Collaboration. Published by the American Physical Society under the terms of the »https://creativecommons.org/licenses/by/4.0/» Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.

60 APPLIED LIFE SCIENCES↗

Femtosecond X-Ray Free Electron Laser Pulse Duration Measurement from Spectral Correlation Function

We present a novel method for measuring the duration of femtosecond x-ray pulses from self-amplified spontaneous emission free electron lasers by performing statistical analysis in the spectral domain. Analytical expressions of the spectral correlation function were derived in the linear regime to extract both the pulse duration and the spectrometer resolution. Numerical simulations confirmed that the method can be also used in the nonlinear regime. The method was demonstrated experimentally at the Linac Coherent Light Source by measuring pulse durations down to 13 fs FWHM.

43 PARTICLE ACCELERATORS↗

The AMPIX electrochemical cell: a versatile apparatus for in situ X-ray scattering and spectroscopic measurements

This article presents a versatile easy-to-use electrochemical cell suitable for in operando , in situ measurements of battery materials during electrochemical cycling using a variety of X-ray techniques. Argonne's multi-purpose in situ X-ray (AMPIX) cell provides reliable electrochemical cycling over extended periods owing to the uniform stack pressure applied by rigid X-ray windows and the formation of a high-fidelity hermetic seal. The suitability of the AMPIX cell for a broad range of synchrotron-based X-ray scattering and spectroscopic measurements has been demonstrated with studies at eight Advanced Photon Source beamlines to date. Compatible techniques include pair distribution function analysis, high-resolution powder diffraction, small-angle scattering and X-ray absorption spectroscopy. These techniques probe a broad range of electronic, structural and morphological features relevant to battery materials. The AMPIX cell enables experiments providing greater insight into the complex processes that occur in operating batteries by allowing the electrochemical reactions to be probed at fine reaction intervals with greater consistency (within the charge–discharge cycle and between different methodologies) with potential for new time-dependent kinetic studies or studies of transient species. Representative X-ray and electrochemical data to demonstrate the functionality of the AMPIX cell are presented.

energy storage (including batteries and capacitors↗

Use Conditions and Efficiency Measurements of DC Power Optimizers for Photovoltaic Systems

No consensus standard exists for estimating annual conversion efficiency of DC-DC converters or power optimizers in photovoltaic (PV) applications. The performance benefits of PV power electronics including per-panel DC-DC converters depend in large part on the operating conditions of the PV system, along with the performance characteristics of the power optimizer itself. This work presents acase study of three system configurations that take advantage of the capabilities of DC power optimizers. Measured conversion efficiencies of DC-DC converters are applied to these scenarios to determine the annual weighted operating efficiency. A simplified general method of reporting weighted efficiency is given, based on the California Energy Commission's CEC efficiency rating and severalinput / output voltage ratios. Efficiency measurements of commercial power optimizer products are presented using the new performance metric, along with a description of the limitations of the approach.

14 SOLAR ENERGY↗

Measuring uncertainty in dose delivered to the cochlea due to setup error during external beam treatment of patients with cancer of the head and neck

Purpose: To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. Methods: Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patients were treated with conventional fractionation using an IMRT dose painting technique, most with 33 fractions. Weekly radiographic imaging was used to correct the patient setup. The authors used rigid registration of the planning CT and Cone Beam CT scans to find the translational and rotational setup errors, and the spatial setup errors of the cochlea. The planning CT was rotated and translated such that the cochlea positions match those seen in the cone beam scans, cochlea doses were recalculated and fractional doses accumulated. Uncertainties in the positions and cumulative doses of the cochlea were calculated with and without setup adjustments from radiographic imaging. Results: The mean setup error of the cochlea was 0.04 ± 0.33 or 0.06 ± 0.43 cm for RL, 0.09 ± 0.27 or 0.07 ± 0.48 cm for AP, and 0.00 ± 0.21 or −0.24 ± 0.45 cm for SI with and without radiographic imaging, respectively. Setup with radiographic imaging reduced the standard deviation of the setup error by roughly 1–2 mm. The uncertainty of the cochlea dose depends on the treatment plan and the relative positions of the cochlea and target volumes. Combining results for the left and right cochlea, the authors found the accumulated uncertainty of the cochlea dose per fraction was 4.82 (0.39–16.8) cGy, or 10.1 (0.8–32.4) cGy, with and without radiographic imaging, respectively; the percentage uncertainties relative to the planned doses were 4.32% (0.28%–9.06%) and 10.2% (0.7%–63.6%), respectively. Conclusions: Patient setup error introduces uncertainty in the position of the cochlea during radiation treatment. With the assistance of radiographic imaging during setup, the standard deviation of setup error reduced by 31%, 42%, and 54% in RL, AP, and SI direction, respectively, and consequently, the uncertainty of the mean dose to cochlea reduced more than 50%. The authors estimate that the effects of these uncertainties on the probability of hearing loss for an individual patient could be as large as 10%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determining plasmonic hot-carrier energy distributions via single-molecule transport measurements

Hot carriers in plasmonic nanostructures, generated via plasmon decay, play key roles in applications such as photocatalysis and in photodetectors that circumvent bandgap limitations. However, direct experimental quantification of steady-state energy distributions of hot carriers in nanostructures has so far been lacking. We present transport measurements from single-molecule junctions, created by trapping suitably chosen single molecules between an ultrathin gold film supporting surface plasmon polaritons and a scanning probe tip, that can provide quantification of plasmonic hot-carrier distributions. Our results show that Landau damping is the dominant physical mechanism of hot-carrier generation in nanoscale systems with strong confinement. The technique developed in this work will enable quantification of plasmonic hot-carrier distributions in nanophotonic and plasmonic devices.

Science & Technology - Other Topics↗

Comparison between the measured and calculated reactivity in measuring the effectiveness of the emergency protection at the stage of physical start-up of unit no. 3 at the Kalinin nuclear power plant

This paper presents comparisons between the effectiveness of the emergency protection under both stationary and nonstationary formulations calculated with the use of the RADUGA-7.5 package and experimental data obtained in measuring the 'weight' of the emergency protection in the process of physical start-up of the VVER-1000 reactor of unit no. 3 of the Kalinin NPP. On the basis of the results obtained, recommendations are given on comparing the measured and calculated reactivity and parameters determined by using its value.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measurement of analyzing power for the reaction p-vector +CH{sub 2} at polarized proton momentum of 7.5 GeV/c (ALPOM2 proposal)

An accurate data base for the analyzing power of thick CH{sub 2} analyzers for high energy protons has been at the basis of several research efforts in a number of laboratories. Starting in the late eighties such data were collected at SATURNE in Saclay, and with the Synchrophasotron in Dubna, and led to an extensive program of study of polarization phenomena in pd interaction, either backward elastic scattering or breakup [1–6]. At about the same time it became evident that measuring polarization observables in elastic ep was going to be the best approach to determine the form factors of the proton, G {sub Ep }and G {sub Mp }, as had been predicted by Akhiezer and Rekalo [7].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗