Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAINTENANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Digital-Twin-Enabling Technologies for Online Condition Monitoring of Nuclear Power Plant Components

Online condition monitoring is an area of active research that may enable optimized scheduling, maintenance, and safety of nuclear power plant components, reducing unnecessary derates while simultaneously improving operational capacity. Digital twins (DTs) are one avenue to conduct online condition monitoring and are currently being explored by national laboratories and universities alike. DTs for online condition monitoring are, in essence, state concurrent models that emulate a physical process which predicts a parameter and compares it against a measured value. A DT’s goal is to provide additional insights by combining and interpreting various sources of information for preventative maintenance scheduling optimization or early fault detection. DTs for condition monitoring are projected to be valuable for meeting requirements under 10 CFR 50.55a, “Codes and Standards,” and 10 CFR 50.65, “Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants”. However, DT technologies are still under significant development, and the process for developing a DT for condition monitoring has not been formalized. Therefore, in this work, we present an initial framework for developing a DT, discuss and review the various challenges and considerations for DT deployment, and identify the opportunities that a DT can improve. The presented framework is intended to help developers formulate a strategy when approaching DT development for condition monitoring. In conclusion, a DT use case for a reactor coolant pump is presented to demonstrate the proposed framework.

advanced sensor instrumentation↗

Novel reusable animal model for comparative evaluation of in vivo growth and protein-expression of Escherichia coli O157 strains in the bovine rumen

Previously, we had demonstrated that Escherichia coli O157:H7 (O157) strain 86–24 expresses proteins involved in survival rather than virulence in vitro in rumen fluid from dairy cattle limit fed a maintenance diet. Here, we verified if this observation would be true for different O157 strains grown in vitro in rumen fluid from, and in vivo in the rumen of, animals on contrasting maintenance (high fiber) and lactation (high energy-protein) diets usually limit fed to dairy cattle. For the in vivo studies, an economical, novel, reusable and non-terminal rumen-fistulated animal model permitting simultaneous evaluation of multiple bacterial strains in the bovine rumen was developed. All experiments were conducted in duplicate using different animals to account for host-related variations. The O157 strains included, 86–24, EDL933 and the super shed SS-17. E. coli Nal R (#5735), derived from a bovine intestinal commensal E. coli, was included as a control. As expected, diet influenced ruminal pH and volatile fatty acid (VFA) composition. The pH ranged from 6.2–7.0 and total VFA concentrations from 109–141 μM/ml, in animals fed the maintenance diet. In comparison, animals fed the lactation diet had a ruminal pH ranging between 5.18–6.0, and total VFA of 125–219 μM/ml. Strain dependent differences in O157 recovery from the rumen fluid of cattle fed either diet was observed, both in vitro and in vivo, with O157 strains 86–24 and EDL933 demonstrating similar survival patterns. Analysis of the O157 proteomes expressed in the rumen fluid/rumen verified previous observations of adaptive responses. Any difference in the adaptive response was mainly influenced by the animal’s diet and growth conditions (in vitro and in vivo) and not the O157 strain. These new insights into the O157 responses could help formulate modalities to control O157 across strains in cattle at all stages of husbandry.

59 BASIC BIOLOGICAL SCIENCES↗

U.S. Effort Support to Examinations at Fukushima - Meeting Notes with Updated Information Requests (FY2020)

Much is still not known about the end-state of core materials in each unit that was operating on March 11, 2011 at the Fukushima Daiichi Nuclear Power Station (Daiichi). Information obtained from Daiichi is required to inform Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This document, which has been updated to include Fiscal Year 2020 (FY2020) information, summarizes results from a U.S. effort to review Daiichi information and extract insights to enhance the safety of existing and future nuclear power plant designs. This U.S. effort, which was initiated in 2014 by the Department of Energy Office of Nuclear Energy (DOE-NE), is completed by a group of experts in reactor safety and plant operations that identify examination needs and evaluate recent Daiichi examination data to address these needs. Since its inception, comprehensive annual reports were issued that document significant safety insights being obtained in areas of special emphasis: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties related to severe accident modeling progression, these insights have and continue to be used to update guidance for severe accident prevention, mitigation, and emergency planning. Reduced uncertainties in modeling the events at Daiichi improve the realism of reactor safety evaluations that inform future D&D activities. For FY2020, it was decided that the program would gain more benefit from a more concise report that emphasizes new information and insights that affect prior findings and recommendations from the U.S. experts participating in this effort. A key aspect of prior U.S. efforts, the updated list of information requests, is included in this letter report to ensure that they are transmitted to organizations within Japan. In addition, findings and associated recommendations are provided regarding information presented by TEPCO Holdings, Nuclear Damage Compensation and Decommissioning Facilitation Corporation (NDF), and the Japan Atomic Energy Agency (JAEA). This letter report also continues to emphasize how information obtained from the affected reactors at Daiichi has been and will continue to be used to update severe accident management strategies, improve maintenance activities (especially in areas of radiation protection) and reduce uncertainties in systems analysis code models. In addition, recommendations are included that would expand the use of this information to provide insights regarding maintenance, radiation protection, design, and siting activities of existing and new reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification and validation of developed short-term forecasting models

Recent advancements in machine learning (ML) and artificial intelligence (AI) technologies provide an opportunity for leveraging data-driven algorithms to predict future nuclear power plant (NPP) operating conditions by using recorded plant process data. Successfully implementing these models can lead to cost-reducing, conditioned-based predictive maintenance through optimized maintenance schedules and a reduction of unnecessary maintenance activities. This report discusses the verification and validation of short-term forecasting processes (i.e., data cleaning, feature selection, model optimization, and forecasting) developed in previous reports. The verification and validation (V&V) process demonstrates the expected precision and accuracy when the ML model encounters new datasets from different systems. Shapley additive explanations were used as the primary means of feature selection across these different data set. Individual models were trained for each data set, then validated through a cross-validation procedure. In this report, two different ML models were tasked to predict variables from three different plant process data sets with varying prediction horizons. The results indicate that support vector regression (SVR) outperformed long short-term memory (LSTM) neural networks in regard to each data set and each prediction horizon in this study, but further tuning and optimization could improve long short-term memory results. However, each forecasting model showed reduced performance as the prediction horizon was extended from 1 hour to 1 day ahead. Research is ongoing to evaluate the optimal input variable space, which is based on a given set of process parameters, to further improve forecasting accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reliability and Maintainability Changing the Culture

The Reliability and Maintainability team strives to ensure the reliability, availability, and maintainability of plant assets throughout their life cycle. This objective is accomplished by providing world-class maintenance engineering support and maintenance processes. University of Tennessee’s Reliability and Maintainability Center (UT RMC) Partnership – Provided subject matter expert (SME) analysis of current state of both sites integrated work control (IWC) and maintenance execution processes.

47 OTHER INSTRUMENTATION↗

Analytics-at-scale of Sensor Data for Digital Monitoring in Nuclear Plants (3 rd Annual Report)

Nuclear power plants collect and store large volumes of heterogeneous data from various components and systems. With recent advances in machine learning (ML) techniques, these data can be leveraged to develop diagnostic and short-term forecasting models to better predict future equipment condition. Maintenance operations can then be planned in advance whenever degraded performance is predicted, thus resulting in fewer unplanned outages and the optimization of maintenance activities. This enables lower maintenance costs and improves the overall economics of nuclear power. This report primarily focuses on developing a short-term forecasting process that leverages a feature selection process to distill large volumes of heterogeneous data and predict specific equipment parameters. A variety of feature selection methods, including Shapley Additive Explanations (SHAP) and variance inflation factor (VIF), were used to select the optimal features as inputs for three ML methods: long short-term memory (LSTM) networks, support vector regression (SVR), and random forest (RF). Each combination of model and input features was used to predict a pump bearing temperature both 1 and 24 hours in advance, based on actual plant system data. The optimal inputs for the LSTM and SVR were selected using the SHAP values, while the optimal input for the RF consisted solely of the response variable itself. Each model produced similar 1-hour-ahead predictions, with root mean square errors (RMSEs) of roughly 0.006. For the 24-hour-ahead predictions, differences could be seen between LSTM, SVR, and RF, as reflected by model performances of 0.036 ± 0.014, 0.0026 ± 0, and 0.063 ± 0.004 RMSE, respectively. As big data and continuous online monitoring become more widely available, the proposed feature selection process can be used for many applications beyond the prediction of process parameters within nuclear infrastructure. This report summarizes the Fiscal Year 2021 research progress encompassing the (1) data cleaning and feature selection necessary for ML applications; (2) development of short-term forecasting models to predict future plant process parameters for both single and multiple time steps ahead; and (3) validation of the feature selection methods and short-term forecasting models given new data from different systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Artificial Intelligence/Machine Learning Technologies for Advanced Reactors (Workshop Summary Report)

A workshop on artificial intelligence and machine learning (AI/ML) for advanced reactors (AR) was held October 5-6, 2021. The workshop was to be attended in-person at ANL but COVID restrictions forced the workshop to go virtual. The objectives of the workshop were to identify the most promising AI/ML opportunities for improving advanced reactor design, optimizing plant performance, and enhancing economic competitiveness and to develop an understanding of the scientific, engineering and licensing challenges facing their application. The workshop planning committee included GAIN, EPRI and NEI and members of three national laboratories (ANL, INL, and ORNL). The workshop was attended by more than 200 individuals representing academic and scientific institutions and the nuclear power industry. The definition put forth for an AI/ML system was one that perceives its environment and takes actions that maximize its chance of achieving its goals. In this report AI/ML refers to next generation algorithms that include deep learning, statistical analysis and data analytics and associated scientific computing and their potential application to the design, licensing, operation and maintenance of ARs. These methods typically incorporate models built from process data and may also include data generated by simulations that represent the behavior of a system. The workshop was organized in response to the growing interest in application of AI/ML for improving the economic competitiveness of nuclear energy. Increasingly more resources are being allocated to investigating the benefits of AI/ML methods. The DOE created the Artificial Intelligence & Technology Office to promote their development. And within the Office of Nuclear Energy, resources have been allocated to explore and understand the potential benefits of AI/ML. Additionally, the national laboratories are strategically positioned with DOE computing facilities such as Summit, Perlmutter, Aurora and Frontier that support large-scale simulations, hybrid HPC models with AI surrogates, and the exploration of new types of generative models emerging from multi-model data streams and sources. The workshop was organized with members of the AR community to understand the effort and to identify the level of interest and progress in this emerging technology. The workshop discussions focused on identifying opportunities for AI/ML across diverse areas of the nuclear industry and identifying current scientific and engineering challenges for advanced reactors that might be addressed through transformational uses of AI/ML. Discussion panels focused on four high-interest technical domains for advanced reactors: design, maintenance and operations, energy storage, and materials. The results of those discussions are summarized in this report. This includes opportunities that were identified for exploiting AI techniques and methods to improve the efficacy and efficiency of reactor analysis and to improve the operation and optimization of advanced reactors. Advanced reactor developers expressed an interest in learning more about AI/ML methods and their application. This included understanding whether ML methods can provide an advantage over existing nonlinear data regression methods for collapsing high-fidelity simulation results into faster running models. A consensus emerged that AR advances planned for the next decade will benefit from the use of AI/ML tools. The need exists to understand and model complex systems across length scales and modalities. AI/ML is a tool for discovery that can yield a set of engineering principles for use by nuclear engineers, licensing bodies, and operators to solve problems in plant design, safety analyses, autonomous operation, and predictive maintenance. While AI/ML represents a new set of tools, an awareness by the nuclear community of the full potential is still in the early stages so there is a need to increase awareness. It appears that the wide-spread adoption of AI/ML tools for ARs would be facilitated by future educational workshops that describe foundational methods and capabilities and describe successful applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Earned Value Management Systems for Operations Activities

An earned value management system (EVMS), which monitors contractor performance, is a requirement for program and project management for all major acquisitions by the United States Federal Government with development effort: (i.e., an asset requiring management attention because of its importance to an agency’s mission; high development, operating, or maintenance costs; high risk and/or high return). As an area less explored in earned value management (EVM) practices, this paper will survey the application of an EVMS for operations activities defined as: (1) Non-capital asset activities that are projects (or project - like) with definable start and end dates, with discrete scopes of work, and measurable accomplishments; as well as (2) Routine or recurring facility or environmental operations. This paper will examine the use of an EVMS to evaluate performance of operations and maintenance activities required once construction of a capital asset is complete and being used as intended. Such activities include upgrades and maintenance in order for capital assets to meet their mission function over a life-cycle (through repair, replacement, etc.). This paper will provide background on this topic from the perspective of the Department of Energy (DOE) Environmental Management (EM) Program. In addition, it will provide material from a panel discussion provided by a group of experts from the October 2019 Office of Environmental Management Project Management Workshop, as well as material from subsequent research on this topic.

97 MATHEMATICS AND COMPUTING↗

Technology Maturation of Wireless Harsh Environment Sensors For Improved Condition Based Monitoring Of Coal Fired Power Generation

The overall goal of this project was to demonstrate and develop the usage of high-temperature (HT) harsh-environment (HE) wireless surface acoustic wave resonator (SAWR) sensor technology to promote reliable maintenance through condition-based maintenance (CBM) for field applications in harsh service conditions associated with power plant environments. The project aimed to advance the HT HE wireless SAWR sensor technology from TRL 5 to TRL 7. In addition to HT HE wireless temperature sensing, efforts were dedicated during this project to investigate, develop and increase the TRL from 3 to 5 for the following technologies: (a) HT HE strain sensors to address additional CBM monitoring needs, such as boiler tube mechanical / thermal stresses, which can provide early indications for boiler tube cracking and failure; and (b) HT aluminum nitride (AlN) and scandium aluminum nitride (ScAlN) based piezoelectric thin film fabrication and implementation of SAW sensors, with the goal of releasing the need to use single crystal piezoelectric materials for SAWRs and thus broaden possible technology applications to non-planar and harder to modify surfaces. To achieve the goals mentioned above, UMaine and its partner, Environetix Technologies Corporation, established partnerships with the following power plants: Longview Power (Maidsville, WV), a coal-fired power plant; Penobscot Energy Recovery Corp (PERC, Orrington, ME), a waste-to-energy power plant; and the UMaine Steam Plant (Orono, ME), an oil / natural gas power plant. To realize wireless HT HE SAWR sensor systems in these harsh service conditions, the University of Maine research team worked with Environetix and these power plants to define, design, fabricate, test and validate a mature prototype wireless temperature SAWR sensor system for boiler tube applications within the HT HE of the reheater pass damper chamber to directly and wirelessly monitor the temperature at eighteen independent boiler tube locations. The system included three levels, or “tiers”, of wireless communication to enable remote monitoring: Tier 1, the wireless link in the reheater pass damper chamber directly accessing the sensors on the boilers; Tier 2, the wireless local area network link, transmitting processed sensor information within the power plant to the Tier 3, a commercial wireless signal carrier company for secure remote data monitoring outside of the power plant. Regarding the wireless sensor system installed at Longview Power, temperature information from the boilers was continuously transmitted from the Longview boilers at Maidsville, WV, to Environetix headquarters, Orono, ME, over a 34 month period, when the system was finally decommissioned. Strain sensors and piezoelectric ScAlN thin film sensors were successfully installed on the exhaust duct at the UMaine Steam Power plant. The advances in wireless strain sensors and thin film piezoelectric film fabrication and testing were performed mostly in UMaine laboratories and field tested at the UMaine Steam Plant, due to its close proximity to UMaine/Environetix, access to the plant facility, and due to difficulties in accessing the other power plants during the COVID shut-down period. The project accomplished the TRL level increase of the targeted CBM technologies through the successful fabrication, installation, test, and validation of dedicated and commercial wireless sensor systems, utilizing the three different power plants. The outcomes of this project, including the wireless sensor data capability, are expected to yield an advance for CBM in harsh power plant environments. The reduction of maintenance costs, improved safety during plant operation, and increased power plant efficiency will lead to increased revenues (i.e., fewer forced outages) due to better process monitoring enabled by the wireless HT HE SAWR temperature sensor technology.

20 FOSSIL-FUELED POWER PLANTS↗

Finding of Effect, And Mitigation Documentation for Building 23-620, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-620 in the town of Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15283), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada (see Figure 1). The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-620 was built in 1968 as office space for the Los Alamos Scientific Laboratory (LASL), who worked on the design and engineering of nuclear weapons. In the 1990s, it became a maintenance facility for Reynolds Electrical & Engineering Company (REECo), and eventually, it became the Real Estate Services building in 2004. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-620 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al.) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-620 was also identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. Mitigation Report: The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 23-620 (Nevada State Historic Preservation Office [SHPO] Resource No. B15283) in the Mercury Historic District (MHD, SHPO Resource No. D230). This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Development of Event-Based Data Acquisition for Acoustic Emission Monitoring of the Structural Integrity of Wind Turbine Blades [Slides]

DOE Alignment: Reduce the cost of floating offshore wind energy in deep waters to $45/MWh by 2035 from today’s estimated $150/MWh20 by: Developing operations and maintenance strategies and increasing wind turbine reliability to reduce periods of non-operation and reduce labor at sea through remote system health monitoring, inspection, and maintenance capabilities incorporating artificial intelligence and predictive maintenance.

17 WIND ENERGY↗

5-year Infrastructure plan at FNAL

Fermilab's 5-year infrastructure plan aims to create a sustainable, safe, and long-lasting pavement network by prioritizing lower-rated pavements first for regular maintenance. FNAL should address the most distressed areas promptly, to extend sitewide pavement longevity and reduce overall maintenance costs. This approach compounds improvements by freeing future year’s capital for more routine pavement maintenance. This allows greater surface areas to be addressed each year, until a sustainable cycle can be achieved. The continually improvements enhance safety, benefit employees, visitors, and equipment transportation while aligning with Fermilab's commitment to environmental responsibility.

Washington, Davion↗

ActiveBAS: A Low-cost, Scalable Control Solution for Grid-Interactive Small and Medium Sized Commercial Buildings

This project aims to develop and enhance a low-cost, highly scalable control solution for Small and Medium-Sized Commercial Buildings (SMCB), assess the business potential at multiple sites, and perform commercialization efforts. The technology can be applied to any buildings served by multiple units, with the benefits being greatest for open-spaced buildings, such as banks, retail stores, restaurants, and factories. This project aims to develop an affordable control solution for: 1) SMCB grid responsiveness, 2) reduction of GHG by changing unit operations, 3) greater reduction in utility costs, and 4) rapid adoption in the marketplace. The proposed technology will be built on a previously developed and demonstrated MPC solution. The minimal sensor requirement and less need of control expertise are the unique feature of the algorithm that leads to low capital and maintenance costs, and short installation and implementation time. These attributes contribute to low capital and maintenance costs, as well as a short installation and implementation time. However, these advantages come with a trade-off: increased difficulties and unreliability when applying traditional modeling and MPC control approaches due to limited information. This final report describes the modeling approaches developed and tested to overcome these challenges. It begins by outlining the modeling challenge posed by minimal sensor requirements, then delves into the proposed modeling approaches, which primarily involve system identification. Finally, preliminary test results for a simulation case study are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Composite Analysis for Low-Level Waste Disposal in the Central Plateau of the Hanford Site (Annual Summary Report (FY 2023))

In accordance with DOE M 435.1-1 requirements and as implemented by DOE/RL-2000-29, the U.S. Department of Energy (DOE), Richland Operations Office has prepared this annual summary for fiscal year (FY) 2023 for maintenance of the Hanford Site Composite Analysis reported in DOE/RL-2019-52 (hereinafter referred to as the updated Hanford Site Composite Analysis). This is the first annual summary report to transition from maintenance of the initial Hanford Site Composite Analysis reported in PNNL-11800 and PNNL-11800, Addendum 1 to maintenance of the updated Hanford Site Composite Analysis following DOE approval of that update.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Finding Of Adverse Effect and Proposed Mitigation for the Removal of Joshua Trees at Building 23-210, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) recently removed two fallen Joshua trees that were part of an Accessory Resource (AR) to the former Department of Defense (DOD) Motor Pool Maintenance Compound in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. C307) on the Nevada National Security Site (NNSS) in Nye County, Nevada (Figure 1). The Joshua trees were part of AR3, a landscaped feature at the entrance to the compound. There are two remaining Joshua trees at risk of falling which may require removal in the future. The NNSA/NFO is proactively consulting with the SHPO regarding the potential removal of the remaining two trees. The purpose of the undertaking is to ensure that dead or dying Joshua trees do not cause damage to the remaining landscape elements, nor injury to NNSS employees. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-210 was the DOD’s motor vehicle maintenance compound constructed in 1951. The compound included its own repair shop and fuel station. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992. The former DOD Motor Pool Compound was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). The foundation for Building 23-210 was also identified in Appendix C of the Mercury PA as a Category III contributing element with three contributing ARs. Category III properties are those that may include elements for which there are several representatives in the MHD, such as foundations, and those elements which possess characteristics that are not unique to the MHD and are commonly found in other non-NNSS facilities. The former DOD compound, which is identified by the foundation for the Building 23-210 and its ARs, is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Development of Human and Technology Integration Guidance for Work Optimization and Effective Use of Information

Existing nuclear power contributes to roughly 20% of the total electricity generation, and consistently provides the highest capacity factor of any other electricity generating resource in the United States. Despite these advantages, the existing nuclear power plant fleet in the United States has been enduring significant challenges in providing electricity in a cost-competitive manner, which has ultimately threatened the long-term economic viability of these plants. A major contributor to these increased operating and maintenance costs has been the continued reliance of a large workforce who perform their work under an operating model that has largely remained unchanged since the commissioning of these nuclear power plants. Unfortunately, while this operating model has provided safe and reliable electricity, other industries have already began transforming their workforce through the use of advanced digital technology and automation that has reduced their operating and maintenance cost significantly. In order for the United States nuclear industry to remain economically viable, a similar transformation must be considered in which digital technologies and automation capabilities are brought in to support key plant functions across all work functions across plant operation, maintenance, and support. To effectively integrate digital technology and automation in the existing nuclear power plant operating model, a multidisciplinary approach is needed that addresses technological and sociotechnical (i.e., human and technology integration) considerations. This report describes an extension to the human and technology integration methodology, herein referred to as Human Integration and Technology Task Force for Work Management Optimization (HITT), to support the safe, reliable, and efficient use of proposed innovations with the intended users in their intended environment to perform their intended tasks. By effectively incorporating human and technology integration into a plant modernization effort by using HITT, we believe that a utility can significantly improve work performance and overall workforce quality of life. For instance, if HITT is performed to optimize work management, scheduling performance and scope stability can be improved by up to 10%. HITT enables these benefits through developing a rich understanding of the work being performed, the utility’s vision, and the opportunities that provide greatest value to optimize performance through a 10-step process illustrated below as a quick guide. The quick guide contains links in the righthand side of each step that allows for navigation to the detailed section (Section 4) of HITT in this technical report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CRADA Number NFE-24-10110 with Qubit Engineering Inc. (CRADA Final Report)

Over the past year, the Qubit Engineering team has pushed the frontiers of power‑grid optimization, working in close collaboration with Oak Ridge National Laboratory (ORNL) and the Tennessee Valley Authority (TVA). Their progress is reflected in three newly submitted conference papers, “Unified Relational GNN Architecture for AC Optimal Power Flow Calculations in Electric Grids,” “Graph‑Based Attention Mechanisms for Solving the AC Optimal Power Flow Problem in Electrical‑Power Networks,” and “Enhanced Power‑Grid Maintenance Planning and Quantum‑Inspired Combinatorial Prospects.” These publications showcase state‑of‑the‑art graph‑neural‑network methods for AC‑OPF and novel quantum‑inspired heuristics for maintenance scheduling. Beyond the academic results, the Qubit team has converted the research into two production‑grade tools built on TVA data: Neuro‑Grid, an AI‑driven power‑flow simulator that provides instant, interactive full‑grid load‑flow visualizations, and Quanta‑Grid, a quantum‑inspired maintenance‑scheduling engine to support logistics optimization for power utilities. Together, these advances demonstrate how Qubit’s partnership with ORNL and TVA is delivering practical, physics‑grounded analytics for next‑generation grid management.

24 POWER TRANSMISSION AND DISTRIBUTION↗