Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Status of MICE

The Muon Ionization Cooling Experiment (MICE) is an experiment currently under construction at the Rutherford Appleton Laboratory (RAL) in the UK. The aim of the experiment is to demonstrate the concept of ionization cooling for a beam of muons, crucial for the requirements of a Neutrino Factory and a Muon Collider. Muon cooling is achieved by measuring the reduction of the four dimensional transverse emittance for a beam of muons passing through low density absorbers and then accelerating the longitudinal component of the momentum using RF cavities. The absorbers are maintained in a focusing magnetic field to reduce the beta function of the beam and the RF cavities are kept inside coupling coils. The main goal of MICE is to measure a fractional drop in emittance, of order -10% for large emittance beams, with an accuracy of 1%(which imposes a requirement that the absolute emittance be measured with an accuracy of 0.1%). This paper will discuss the status of MICE, including the progress in commissioning the muon beam line at the ISIS accelerator at RAL, the construction of the different detector elements in MICE and the prospects for the future.

43 PARTICLE ACCELERATORS↗

Moessbauer Study and Macroscopic/Global Magnetic Behavior of Powdered Ilmenite (FeTiO{sub 3}) Sample

In this article, the commercial synthetic powdered sample of ilmenite (FeTiO{sub 3}) has been re-examined by Moessbauer spectroscopy in the paramagnetic regime from 77 K to 280 K and in a magnetically ordered state below 57 K. The effective vibrating mass and the Debye temperature was found to be (78{+-}3) amu and (359{+-}27) K, respectively. The two sextet components were used for correct fitting of the Moessbauer spectra recorded at 5 K and 45 K in an external magnetic field of 5 T. Moreover, the macroscopic magnetic measurements were carried out by an MPMS XL-7 magnetometer to determine a temperature dependence of the molar susceptibility and hysteresis loops of this sample. The Moessbauer spectra and magnetization measurements confirm that below the ordering temperature of ilmenite, it behaves as a non-ideal antiferromagnetic material with a significant magnetic hardening at low temperatures. In addition, the magnetic molar susceptibility follows a Curie-Weiss law with C{sub m=5.8x10{sup -5}Km{sup 3}/mol}, and Weiss temperature {theta}{sub p} = 30.6 K.

36 MATERIALS SCIENCE↗

Dry calibration of electromagnetic flowmeters based on numerical models combining multiple physical phenomena (multiphysics)

This paper presents a method for dry calibration of an electromagnetic flowmeter (EMF). This method, which determines the voltage induced in the EMF as conductive liquid flows through a magnetic field, numerically solves a coupled set of multiphysical equations with measured boundary conditions for the magnetic, electric, and flow fields in the measuring pipe of the flowmeter. Specifically, this paper details the formulation of dry calibration and an efficient algorithm (that adaptively minimizes the number of measurements and requires only the normal component of the magnetic flux density as boundary conditions on the pipe surface to reconstruct the magnetic field involved) for computing the sensitivity of EMF. Along with an in-depth discussion on factors that could significantly affect the final precision of a dry calibrated EMF, the effects of flow disturbance on measuring errors have been experimentally studied by installing a baffle at the inflow port of the EMF. Results of the dry calibration on an actual EMF were compared against flow-rig calibration; excellent agreements (within 0.3%) between dry calibration and flow-rig tests verify the multiphysical computation of the fields and the robustness of the method. As requiring no actual flow, the dry calibration is particularly useful for calibrating large-diameter EMFs where conventional flow-rig methods are often costly and difficult to implement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetite Nanoparticles Coated with Rifampicin and Chlortetracycline for Drug Delivery Applications

Four types of biocompatible magnetic fluids based on superparamagnetic nanoparticles with Fe{sub 3}O{sub 4} cores were functionalized with antibiotics (rifampicin or chlortetracycline) as potential candidates for in vivo biomedical applications, such as magnetically controlled drug delivery. The synthesis consisted in coprecipitation of iron oxide in basic, as well as in acid medium, followed by the dispersion of the resulted magnetite nanoparticles in aqueous solution containing the antibiotic. The chosen method to prepare the magnetite-core/drug-shell systems avoided intermediate organic coating of the magnetic nanoparticles. Comparative analysis of the rheological features of the aqueous magnetic fluid samples was performed. The structural features of the coated magnetic particles were investigated by X-Ray Diffraction (XRD), Transmission Electron Microscopy (TEM) and Vibrating Sample Magnetometry (VSM). Good crystallinity and adequate stability in time were evidenced. Drug delivery curves were spectrophotometrically provided.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Precision measurement of {pi}{pi} scattering lengths at the NA48/2 experiment

The NA48/2 experiment at CERN [1] collected {approx}18{center_dot}10{sup 9} charged kaon decays during the years 2003/4. Along with the primary goals of the collaboration, i.e. the measurement of the CP-violating asymmetry in the K{sup {+-}}{yields}{pi}{sup {+-}}{pi}{sup +}{pi}{sup -} and K{sup {+-}}{yields}{pi}{sup {+-}}{pi}{sup 0}{pi}{sup 0} decays thanks to the simultaneous collection of K{sup +} and K{sup -} events, the collected data allowed to perform many other interesting analyses. In this paper two independent measurements of {pi}{pi} scattering lengths will be reviewed, using NA48/2 data from the K{sup {+-}}{yields}e{sup {+-}}{nu}{pi}{sup +}{pi}{sup -} decay and from the cusp effect in K{sup {+-}}{yields}{pi}{sup {+-}}{pi}{sup +}{pi}{sup -} respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

N- and P-Type Cluster Source

We describe our newest ClusterIon registered source, and show detailed data for B{sub 18}H{sub x}{sup +}, C{sub 7}H{sub 7}{sup +}, C{sub 16}H{sub x}{sup +}, P{sub 4}{sup +}, and As{sub 4}{sup +} beams. These species are derived from both low-temperature solids and gaseous sources. 2D beam profiles are presented, along with mass spectra, beam current performance, and long-term beam reproducibility. The data were collected using the injection stage of a commercial ion implanter equipped with a 120 degree analyzer magnet. Beam profiles at magnet entrance and exit planes were produced using a specially designed 2D profiler. Beam currents were measured after mass analysis using a Faraday cup over an effective energy range of 200 eV to 10 keV.

43 PARTICLE ACCELERATORS↗

Chemical stability of highly (0001) textured Sm(CoCu){sub 5} thin films with a thin Ta capping layer

With the highest magnetocrystalline anisotropy constant (Ku) among practical magnetic materials, SmCo{sub 5} could be a very attractive candidate for future high areal density magnetic recording. However, its corrosion resistance is always a concern in recording media applications. In this paper, the chemical stability and microstructures of highly (0001) textured Sm(CoCu){sub 5} thin films with and without a 3 nm Ta capping layer were reported. For Sm(CoCu){sub 5} thin films without a capping layer, the coercivity decreases significantly (from 8kOe to 1kOe) within one month. Sm(CoCu){sub 5} thin films capped with a thin Ta layer (3 nm) behave differently. Even exposed to a laboratory environment (25 deg. C) over 3 years, the Ta-capped Sm(CoCu){sub 5} thin films are stable in terms of structural and magnetic properties, i.e., there were no changes in X-ray diffraction peaks and vibrating sample magnetometer hysteresis loops. Microstructure of Ta-capped Sm(CoCu){sub 5} thin films showed that Sm(CoCu){sub 5} formed a domelike particle assembly structure on a smooth Ru underlayer and were well covered by partially oxidized Ta capping layer, as shown by TEM cross-section micrographs. Accelerated corrosion treatment (130 deg. C, 95% relative humidity, 6 h) was performed on Ta-capped Sm(CoCu){sub 5} thin films. X-ray photoelectron spectroscopy (XPS) results showed that no Co was detected on the sample surface before the corrosion treatment, but strong XPS signals of CoOx and Co(OH)x were observed after treatment. Therefore, none of our Sm(CoCu){sub 5} thin films can pass the accelerated corrosion test. Hcp-phased CoPt-alloys are proposed as better capping materials for Sm(CoCu){sub 5} thin films in future high-density magnetic recording applications.

36 MATERIALS SCIENCE↗

Static and dynamic magnetic properties of epitaxial Co{sub 2}FeAl Heusler alloy thin films

Structural and magnetic properties of epitaxial Co{sub 2}FeAl Heusler alloy thin films were investigated. Films were deposited on single crystal MgO (001XS) substrates at room temperature, followed by an annealing process at 600 deg. C. MgO and Cr buffer layers were introduced in order to enhance crystalline quality, and improve magnetic properties. Structural analyses indicate that samples have grown in the B2 ordered epitaxial structure. VSM measures show that the MgO buffered sample displays a magnetization saturation of 1010 {+-} 30 emu/cm{sup 3}, and Cr buffered sample displays a magnetization saturation of 1032 {+-} 40 emu/cm{sup 3}. Damping factor was studied by strip-line ferromagnetic resonance measures. We observed a maximum value for the MgO buffered sample of about 8.5 x 10{sup -3}, and a minimum value of 3.8 x 10{sup -3} for the Cr buffered one.

36 MATERIALS SCIENCE↗

Epitaxial high saturation magnetization FeN thin films on Fe(001) seeded GaAs(001) single crystal wafer using facing target sputterings

It was demonstrated that Fe-N martensite ({alpha}') films were grown epitaxially on Fe(001) seeded GaAs(001) single crystal wafer by using a facing target sputtering method. X-ray diffraction pattern implies an increasing c lattice constant as the N concentration increases in the films. Partially ordered Fe{sub 16}N{sub 2} films were synthesized after in situ post-annealing the as-sputtered samples with pure Fe{sub 8}N phase. Multiple characterization techniques including XRD, XRR, TEM, and AES were used to determine the sample structure. The saturation magnetization of films with pure Fe{sub 8}N phase measured by VSM was evaluated in the range of 2.0-2.2 T. The post annealed films show systematic and dramatic increase on the saturation magnetization, which possess an average value of 2.6 T. These observations support the existence of giant saturation magnetization in {alpha}''-Fe{sub 16}N{sub 2} phase that is consistent with a recent proposed cluster-atom model and the first principles calculation [N. Ji, X. Q. Liu, and J. P. Wang, New J. Phys. 12 063032 (2010)].

36 MATERIALS SCIENCE↗

Diffractive physics in ALICE at the LHC

Diffractive and photon induced physics is a research area with a remarkable discovery potential at the LHC. ALICE has started a program to exploit its unique capabilities to study the subject in both proton-proton and heavy ion collisions. We discuss some aspects of a new sub-detector for the ALICE experiment at the LHC. This detector would enhance the performance of ALICE to address some relevant topics on this matter. It consists of four stations of scintillator pads that would tag the diffractive gap more efficiently.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preliminary Study of Two-Neutron States via the ({sup 18}O,{sup 16}O) Reaction at 84 MeV

A study of light neutron-rich nuclei has been performed at the INFN-LNS laboratory in Catania (Italy) by the ({sup 18}O, {sup 16}O) reaction at 84 MeV incident energy on {sup 9}Be, {sup 11}B and {sup 13}C targets. The {sup 16}O ejectiles have been momentum analyzed and detected at forward angles by the MAGNEX magnetic spectrometer. The energy spectra of {sup 15}C show several known low lying states up to about 7 MeV excitation energy and unknown resonant structures at higher excitation energy. The strong excitation of these latter together with the measured width of about 2 MeV FWHM could indicate the presence of collective modes of excitation connected to the transfer of a correlated neutron pair. Also considerations regarding the reaction mechanism and the nuclei involved in the transfer seem to confirm such a conclusion. Similar features characterize the energy spectra of the {sup 11}Be and {sup 13}B nuclei. The achieved mass resolution (about 1/160) guarantying the identification of the reaction products corresponding to different reaction channels has allowed to study the relative yields for the different reaction channels. The measured yields show an enhancement of the two-neutron transfer channel compared to the one-neutron transfer. This result seems to indicate that the ({sup 18}O, {sup 16}O) reaction proceeds mainly by the direct transfer of the neutron pair and that the second order processes are negligible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Qweak - A Search For New Physics

Qweak is a currently running experiment at the Thomas Jefferson National Accelerator Lab in Newport News Virginia USA that will use parity-violating elastic electron-proton scattering to measure the weak charge of the proton (Q{sup P}{sub weak}). Longitudinally polarized electrons scatter off a liquid hydrogen target and pass through a toroidal-field magnetic spectrometer. In order to perform a 4% measurement of Q{sup P}{sub weak}, we will need to measure the momentum transfer (Q{sup 2}) to 0.5%. The Q{sup 2} will be measured using a tracking system consisting of two gas electron multipliers (GEM), four horizontal drift chambers (HDC), and four vertical drift chambers (VDC). I will outline the design of the full apparatus and discuss the details of the Q{sup 2} and Q{sup P}{sub weak} measurements that will be complete in 2012 with a brief update on the experiment's progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Rietveld Method to the Structural Characteristics of some Bulk and Nanocrystalline Materials

In recent years, the full pattern structure refinement using Rietveld Method, with the advent of increased performance of powder diffractometers has allowed enormous progress in the analysis of powder diffraction data. In the full pattern structure refinement, with the possibility of varying peak shape parameters and site occupancies along with the structural and instrumental parameters, provides information not only on the crystal and magnetic structure, but also gives precise knowledge of the particle size and micro-structural strain. In this report Rietveld profile refinement of some bulk and nano crystalline materials has been presented.

36 MATERIALS SCIENCE↗

The energy dependence of the pp {yields} K{sup +}n{Sigma}{sup +} reaction

The energy dependence of the total cross section for the pp {yields} K{sup +}n{Sigma}{sup +} reaction has been investigated at the magnetic spectrometer COSY-ANKE. Signals from the production of the {Sigma}{sup +} hyperon were searched for in three simultaneously measured spectra. The values obtained for the total production cross section {sigma}({Sigma}{sup +}) are slightly below those of {sigma}({Sigma}{sup 0}) at the same excess energies. They follow a phase space dependence and do not show any evidence for strong threshold effects or a significant n{Sigma}{sup +} final state interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

End station for nanoscale magnetic materials study: Combination of scanning tunneling microscopy and soft X-ray magnetic circular dichroism spectroscopy

We have constructed an end station for nanoscale magnetic materials study at the soft X-ray beamline HiSOR BL-14 at Hiroshima Synchrotron Radiation Center. An ultrahigh-vacuum scanning tunneling microscope (STM) was installed for an in situ characterization of nanoscale magnetic materials in combination with soft X-ray magnetic circular dichroism (XMCD) spectroscopy experiment. The STM was connected to the XMCD experimental station via damper bellows to isolate it from environmental vibrations, thus achieving efficient spatial resolution for observing Si(111) surface at atomic resolution. We performed an in situ experiment with STM and XMCD spectroscopy on Co nanoclusters on an Au(111) surface and explored its practical application to investigate magnetic properties for well-characterized nanoscale magnetic materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An in-depth noise model for giant magnetoresistance current sensors for circuit design and complementary metal–oxide–semiconductor integration

Full instrumentation bridges based on spin valve of giant magnetoresistance and magnetic tunnel junction devices have been microfabricated and experimentally characterized from the DC and noise viewpoint. A more realistic model of these devices was obtained in this work, an electrical and thermal model previously developed have been improved in such a way that noise effects are also included. We have implemented the model in a circuit simulator and reproduced the experimental measurements accurately. This provides a more realistic and complete tool for circuit design where magnetoresistive elements are combined with well-known complementary metal–oxide–semiconductor modules.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MULTIWAVELENGTH OBSERVATIONS OF 3C 454.3. III. EIGHTEEN MONTHS OF AGILE MONITORING OF THE 'CRAZY DIAMOND'

We report on 18 months of multiwavelength observations of the blazar 3C 454.3 (Crazy Diamond) carried out in the period 2007 July-2009 January. In particular, we show the results of the AGILE campaigns which took place on 2008 May-June, 2008 July-August, and 2008 October-2009 January. During the 2008 May-2009 January period, the source average flux was highly variable, with a clear fading trend toward the end of the period, from an average gamma-ray flux F{sub E>100{sub MeV}} {approx}> 200 x 10{sup -8} photons cm{sup -2} s{sup -1} in 2008 May-June, to F{sub E>100{sub MeV}} {approx} 80 x 10{sup -8} photons cm{sup -2} s{sup -1} in 2008 October-2009 January. The average gamma-ray spectrum between 100 MeV and 1 GeV can be fit by a simple power law, showing a moderate softening (from GAMMA{sub GRID} {approx} 2.0 to GAMMA{sub GRID} {approx} 2.2) toward the end of the observing campaign. Only 3sigma upper limits can be derived in the 20-60 keV energy band with Super-AGILE, because the source was considerably off-axis during the whole time period. In 2007 July-August and 2008 May-June, 3C 454.3 was monitored by Rossi X-ray Timing Explorer (RXTE). The RXTE/Proportional Counter Array (PCA) light curve in the 3-20 keV energy band shows variability correlated with the gamma-ray one. The RXTE/PCA average flux during the two time periods is F{sub 3-20{sub keV}} = 8.4 x 10{sup -11} erg cm{sup -2} s{sup -1}, and F{sub 3-20{sub keV}} = 4.5 x 10{sup -11} erg cm{sup -2} s{sup -1}, respectively, while the spectrum (a power law with photon index GAMMA{sub PCA} = 1.65 +- 0.02) does not show any significant variability. Consistent results are obtained with the analysis of the RXTE/High-Energy X-Ray Timing Experiment quasi-simultaneous data. We also carried out simultaneous Swift observations during all AGILE campaigns. Swift/XRT detected 3C 454.3 with an observed flux in the 2-10 keV energy band in the range (0.9-7.5) x 10{sup -11} erg cm{sup -2} s{sup -1} and a photon index in the range GAMMA{sub XRT} = 1.33-2.04. In the 15-150 keV energy band, when detected, the source has an average flux of about 5 mCrab. GASP-WEBT monitored 3C 454.3 during the whole 2007-2008 period in the radio, millimeter, near-IR, and optical bands. The observations show an extremely variable behavior at all frequencies, with flux peaks almost simultaneous with those at higher energies. A correlation analysis between the optical and the gamma-ray fluxes shows that the gamma-optical correlation occurs with a time lag of tau = -0.4{sup +0.6}{sub -0.8} days, consistent with previous findings for this source. An analysis of 15 GHz and 43 GHz VLBI core radio flux observations in the period 2007 July-2009 February shows an increasing trend of the core radio flux, anti-correlated with the higher frequency data, allowing us to derive the value of the source magnetic field. Finally, the modeling of the broadband spectral energy distributions for the still unpublished data, and the behavior of the long-term light curves in different energy bands, allow us to compare the jet properties during different emission states, and to study the geometrical properties of the jet on a time-span longer than one year.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE IMPLICATIONS OF LATE INTERNAL DISSIPATION FOR SHALLOW-DECAY AFTERGLOW EMISSION AND ASSOCIATED HIGH-ENERGY GAMMA-RAY SIGNALS

The origin of the shallow-decay emission during early X-ray afterglows has been an open issue since the launch of the Swift satellite. One of the appealing models is the late internal dissipation model, where X-ray emission during the shallow-decay phase is attributed to internal dissipation, analogous to the prompt gamma-ray emission. We discuss possible scenarios of the late prompt emission, such as late internal shocks, magnetic reconnection, and photospheric dissipation. We also consider the consequences of late dissipation and a two-component (early and late) jet model for the high-energy (GeV-TeV) emission. We study not only synchrotron self-Compton (SSC) emission from the early and late jets but also external inverse-Compton (EIC) emission, which is naturally predicted in the late dissipation model. For the latter, we perform numerical calculations taking into account the equal-arrival-time surface of EIC photons and show that the EIC component typically has a peak at {approx}1-100 GeV which may dominate over the SSC components. We demonstrate that very high energy gamma rays from both these components are detectable for nearby and/or energetic gamma-ray bursts, with current and future Cherenkov detectors such as MAGIC, VERITAS, CTA, and HAWC, and possibly Fermi. Although the expected event rate would not be large, detections should be useful as a test of the model. Multi-wavelength observations using both the ground-based telescopes and the Swift and/or Fermi satellites are also important to constrain the models.

79 ASTRONOMY AND ASTROPHYSICS↗