Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Dual-Purpose Canister Filling Demonstration Project Progress Report

This report discusses the progress made at the Oak Ridge National Laboratory to support direct disposal of dual-purpose canisters (DPCs). Acceptable filler materials should demonstrate that the probability of criticality in DPCs during the disposal timeframe is below the probability threshold for inclusion in a repository performance assessment. This effort, which will ultimately result in a full-scale demonstration, includes computational fluid dynamics (CFD) modelling developed to gauge the filling process and to uncover any unforeseen issues. Filling simulations of the lower region (mouse holes) of a prototypic DPC show successfully simulate filling of the void space inside the canister and a smooth, even progression of the liquid level. Flow through a pipe that is similar to the drainpipe in a DPC is being investigated separately to gain valuable insight of the flow regime inside a pipe. Three physical experiments validating the computational filling model have been completed using surrogate liquids. One experiment using molten metal has been completed and the results demonstrate adequate filling of the canister void spaces. Although the scale experiment observed some void spaces related to shrinkage of the metal during cooling, the volume filled is expected to be sufficient to meet the purpose of moderator exclusion. Further experiments will scale up the geometry, moving towards a full-sized DPC demonstration, and provide a more rigorous investigation of candidate filler materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Kiloampere, Variable-Temperature, Critical-Current Measurements of High-Field Superconductors

We review variable-temperature, transport critical-current ($I_\text{c}$) measurements made on commercial superconductors over a range of critical currents from less than 0.1 A to about 1 kA. We have developed and used a number of systems to make these measurements over the last 15 years. Two exemplary variable-temperature systems with coil sample geometries will be described: a probe that is only variable-temperature and a probe that is variable-temperature and variable-strain. The most significant challenge for these measurements is temperature stability, since large amounts of heat can be generated by the flow of high current through the resistive sample fixture. Therefore, a significant portion of this review is focused on the reduction of temperature errors to less than ±0.05 K in such measurements. A key feature of our system is a pre-regulator that converts a flow of liquid helium to gas and heats the gas to a temperature close to the target sample temperature. The pre-regulator is not in close proximity to the sample and it is controlled independently of the sample temperature. This allows us to independently control the total cooling power, and thereby fine tune the sample cooling power at any sample temperature. The same general temperature-control philosophy is used in all of our variable temperature systems, but the addition of another variable, such as strain, forces compromises in design and results in some differences in operation and protocol. These aspects are analyzed to assess the extent to which the protocols for our systems might be generalized to other systems at other laboratories. Our approach to variable-temperature measurements is also placed in the general context of measurement-system design, and the perceived advantages and disadvantages of design choices are presented. To verify the accuracy of the variable-temperature measurements, we compared critical-current values obtained on a specimen immersed in liquid helium (“liquid” or $I_{\text{c}}$ $_{\text{liq}}$) at 5 K to those measured on the same specimen in flowing helium gas (“gas” or Ic gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb 3 Sn, and MgB 2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the “correct” critical current, which was assumed to be the $I_{\text{c}}$ $_{\text{liq}}$. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases.

47 OTHER INSTRUMENTATION↗

Pressure drop in the SHOOT superfluid helium acquisition system

Central to the upcoming Superfield Helium On-Orbit Transfer (SHOOT) demonstration is the fluid acquisition system. The main component of the system is a rectangular cross-section gallery area with one side fabricated from a fine mesh screen. He II enters through the screen and is delivered to a fountain effect pump. A model is proposed to predict the pressure drop as fluid flows through the screen and an expression is derived for the required gallery arm length as a function of flow rate demand. The model is compared with measurement of pressure drop in a full scale SHOOT gallery arm operated with flow rates of up to 850 cu dm/hr. The tests were conducted in the University of Wisconsin horizontal liquid helium flow facility to minimize gravitational effects.

Nissen, J. A.↗

On The Validity of the Assumed PDF Method for Modeling Binary Mixing/Reaction of Evaporated Vapor in GAS/Liquid-Droplet Turbulent Shear Flow

An Investigation of the statistical description of binary mixing and/or reaction between a carrier gas and an evaporated vapor species in two-phase gas-liquid turbulent flows is perfomed through both theroetical analysis and comparisons with results from direct numerical simulations (DNS) of a two-phase mixing layer.

Vapor Binary Mixing Turbulent flows↗

A simple and effective five-equation two-phase numerical model for liquid-vapor phase transition in cavitating flows

Numerical difficulties, notably the non-monotonic behavior of the Wood speed of sound and the volume fraction positivity, associated with the reduced five-equation two-phase flow model of Kapila et al. (2001) [A.K. Kapila, R. Menikoff, J.B. Bdzil, S.F. Son, D.S. Stewart, 2001. Two-phase modeling of deflagration-to-detonation transition in granular materials: reduced equations, Physics of Fluids 13(10), 3002–3024] have been resolved in the past through the introduction of a frozen speed of sound and an algebraic approach for mechanical relaxation afforded by a pressure non-equilibrium six-equation model proposed by [R. Saurel, F. Petitpas, R.A. Berry, 2009. Simple and efficient relaxation methods for interfaces separating compressible fluids, cavitating flows and shocks in multiphase mixture, J. Comput. Phys. 228, 1678–1712]. By contrast, it is explored and demonstrated in this work that these difficulties can in fact still be resolved within the numerical scheme for solving the reduced five-equation model by numerically replacing the Wood speed of sound for the estimates of wave speeds in the approximate Riemann solver HLLC with the monotonic mixture speed of sound for a transport five-equation model. For shock interface (artificial mixture separating pure or nearly pure fluids) interaction problems, with the apparent advantage of monotonic behavior of the speed of sound in the interface, the effect of the numerical replacement is also confined to the interface. Differences other than the behavior of the speed of sound within the interface in the solutions due to the replacement diminish with increasing resolution when reasonable solution can be obtained with Wood speed of sound. For cavitating/expansion problems in physical fluid mixture, it is pointed out and explained why acoustics in the numerical solutions still propagate at the Wood speed of sound (therefore consistent with the reduced five-equation model) even though in some cases a much higher speed of sound like the numerical replacement above for solving the reduced five-equation model or the frozen speed of sound for solving a six-equation model is used for the estimates of wave speeds in the HLLC scheme. A variant of the five-equation two-phase flow model by Saurel et al. (2008) [R. Saurel, F. Petitpas, R. Abgrall, 2008. Modelling phase transition in metastable liquids: application to cavitating and flashing flows, J. Fluid Mech. 607, 313–350] is then constructed for liquid-vapor phase transition in cavitating flows. The relaxation toward thermo-chemical equilibrium during phase transition is achieved by solving a simple system of algebraic equations for the equilibrium state variables for better efficiency, following Pelanti and Shyue (2014) [M. Pelanti, K.-M. Shyue, 2014. A mixture-energy-consistent six-equation two-phase numerical model for fluid with interfaces, cavitation and evaporation waves. J. Comput. Phys. 259, 331–357]. Therefore, the current model retains both the simplicity afforded by the five-equation model and the efficiency of the algebraic relaxation solver. An alternative algebraic approach for handling the non-conservative term (the so-called K∇ · u term) in the reduced five-equation model for mechanical equilibrium of a liquid-vapor mixture is also explored by enforcing the thermal equilibrium at the same time. Finally, numerical results of sample tests in both one and two dimensions in the literature as well as that in three dimensions demonstrate the effectiveness and ability of the proposed model to simulate cavitating flows. An interesting mechanism of shock generation by acoustics in water due to phase transition is then found by the numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reducing Fatigue in a Rotary Flowmeter

Redesign of vanes straightening flow of liquid in rotary flowmeter increase fatigue lives of vanes and rotor. Purpose of vanes to eliminate turbulence so proportionality between flow and rotor speed constant. Nonuniform but symmetrical, new spacing of straightener vanes prevents flow wake from strongly interacting with rotor blades. At same time, vanes ensure accurate flow-rate measurement.

Rao, G.↗

Effect of the greenhouse gases (CO2, H2O, SO2) on Martian paleoclimate

There is general agreement that certain surface features on Mars are indicative of the presence of liquid water at various times in the geologic past. In particular, the valley networks are difficult to explain by a mechanism other than the flow of liquid water. It has been suggested in several studies that a thick CO2 atmosphere on Mars early in its history could have provided a greenhouse warming that would have allowed the flow of water either on the surface or just below the surface. However, this effect was examined with a detailed radiation model, and it was found that if reduced solar luminosity early in the history of the solar system is taken into account, even three bars of CO2 will not provide sufficient greeenhouse warming. The addition of water vapor and sulflur dioxide (both plausible gases that may have been emitted by Martian volcanoes) to the atmosphere also fail to warm the surface above 273 K for reduced solar luminosity conditions. The increase in temperature may be large enough, however, for the formation of these features by brines.

Postawko, S. E.↗

Sintered plug flow modulation of a vapor-liquid phase separator for a helium II vessel

Presented is a system for modulation of a superfluid (helium II) flow in a vapor-liquid phase separator, for use in cryogenic storage tanks in future space missions. The system consists of a semicircular mechanically operated shutter, downstream of the separator plug, rotated at 0.1 rpm to control the operational surface area of the separator. The mass flow rate was varied from 10 to 22 mg/s. Pressure gradients across the plug are also discussed.

Frederking, T. H. K.↗

DSMC simulation of two-phase plume flow with UV radiation

Rarefied gas-particle two-phase plume in which the phase of particles is liquid or solid flows from a solid propellant rocket of hypersonic vehicle flying at high altitudes, the aluminum oxide particulates not only impact the rarefied gas flow properties, but also make a great difference to plume radiation signature, so the radiation prediction of the rarefied gas-particle two-phase plume flow is very important for space target detection of hypersonic vehicles. Accordingly, this project aims to study the rarefied gas-particle two-phase flow and ultraviolet radiation (UV) characteristics. Considering a two-way interphase coupling of momentum and energy, the direct simulation Monte Carlo (DSMC) method is developed for particle phase change and the particle flow, including particulate collision, coalescence as well as separation, and a Monte Carlo ray trace model is implemented for the particulate UV radiation. A program for the numerical simulation of the gas-particle two-phase flow and radiation in which the gas flow nonequilibrium is strong is implemented as well. Ultraviolet radiation characteristics of the particle phase is studied based on the calculation of the flow field coupled with the radiation calculation, the radiation model for different size particles is analyzed, focusing on the effects of particle emission, absorption, scattering as well as the searchlight emission of the nozzle. A new approach may be proposed to describe the rarefied gas-particle two-phase plume flow and radiation transfer characteristics in this project.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical Modeling of Boiling in a Heated Tube

This paper presents numerical models of boiling in a heated tube using the Generalized Fluid System Simulation Program (GFSSP), a finite-volume-based general-purpose flow network code developed at NASA/Marshall Space Flight Center. The heated tube is discretized into a one-dimensional array of nodes and branches to represent the flow of liquid and vapor in a tube with a prescribed pressure differential. The solid wall is also discretized into solid nodes and conductors to allow for heat transfer between the wall and the fluid. The conservation equations of mass, momentum, and energy of the fluid are solved simultaneously with the energy conservation equation for the solid wall. Two experimental configurations of fluid flowing in a vertical tube have been simulated, one with water and the other with liquid hydrogen. This paper compares experimental data with numerical predictions based on four different published correlations for boiling heat transfer coefficients. Three of these correlations are applicable to the saturated vertical flow conditions of the experiments. One of them is applicable to film boiling and has been used for the liquid hydrogen experiment, which was in film boiling regime. For the case of boiling water, the predictions of wall temperatures using the boiling heat transfer correlations agreed well with the experimental results. However, in the case of boiling hydrogen larger discrepancies were observed between the experimental data and numerical predictions.

Majumdar, Alok↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scaling of Two-Phase Flows to Partial-Earth Gravity

A report presents a method of scaling, to partial-Earth gravity, of parameters that describe pressure drops and other characteristics of two-phase (liquid/ vapor) flows. The development of the method was prompted by the need for a means of designing two-phase flow systems to operate on the Moon and on Mars, using fluid-properties and flow data from terrestrial two-phase-flow experiments, thus eliminating the need for partial-gravity testing. The report presents an explicit procedure for designing an Earth-based test bed that can provide hydrodynamic similarity with two-phase fluids flowing in partial-gravity systems. The procedure does not require prior knowledge of the flow regime (i.e., the spatial orientation of the phases). The method also provides for determination of pressure drops in two-phase partial-gravity flows by use of a generalization of the classical Moody chart (previously applicable to single-phase flow only). The report presents experimental data from Mars- and Moon-activity experiments that appear to demonstrate the validity of this method.

Hurlbert, Kathryn M.↗