Photometry of asteroids
Photographic and photoelectric photometry of asteroids, discussing luminescence, reflectivities, light curves, colors and phase variations observations
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Photographic and photoelectric photometry of asteroids, discussing luminescence, reflectivities, light curves, colors and phase variations observations
Optical fluorescence of lunar transients in UV to IR range for rock forming silicates, using electron microprobe with cathode luminescence capability
Luminescence biometer detects presence of life by means of light-emitting chemical reaction of luciferin and luciferase with adenosine triphosphate (ATP) that occurs in all living cells. Amount of light in reaction chamber is measured to determine presence and extent of life.
A study of techniques for preparing n-type material and junctions which yield the most consistent high diode efficiency values high lighted the role that Ga vacancies and/or associated defects play in reducing the green luminescent efficiency of n-type GaP. A useful method for obtaining good quality material was developed. It is shown that junction formation at high temperatures in a process where the n to p transition occurs without removing the substrate from the furnace yields devices superior to those obtained by diffusion or double epitaxy in the conventional manner previously used for GaP junction formation.
Theoretical and experimental investigations on CdS single crystals and CuxS:CdS photovoltaic cells prepared from CdS single crystals by a chemical-dip procedure are described. The studies are aimed at clarifying cell mechanisms which affect key cell properties (efficiency, reliability, and lifetime) by examining the properties of intrinsic and extrinsic defects in the junction and surface regions and their effects on carrier transport through these regions. The experimental research described includes studies of thermal, infrared, and field quenching of acceptor-doped CdS crystals; investigation of optical and electrical properties of CuxS:CdS photovoltaic cells (current-voltage characteristics, spectral distribution of photocurrent and photovoltage) and the dependence of these properties on temperature and light intensity; measurement of changes, as a result of heat treatment in ultrahigh vacuum, in the spectral distribution of photoconductivity at room temperature and liquid nitrogen temperature, the luminescence spectrum at liquid nitrogen temperature, and the thermally stimulated current curves of CdS crystals; determination of the effect of irradiation with 150 keV (maximum) X-rays on the spectral distribution of photoconductivity and thermally-stimulated current of CdS crystals; and studies of the effect of growth conditions on the photoconductive properties of CdS crystals.
The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.
The photoluminescence and optical transmission of the four widely used diffusion-pump oils, DC-705, DC-704, Convalex-10, and Convoil-20, were measured. Each of the oils was found to be transparent throughout the visible region, showed some absorption in the near-UV region, and became very opaque below approximately 300 nm. Both Convalex-10 and Convoil-20 turned yellow after exposure to UV light. No such change was noted in DC-705 or DC-704. Photoluminescence was produced in each of the four oils when irradiated with UV light. Both DC-705 and DC-704 had a nearly identical luminescence spectra that peaked at 350 nm. The spectra of Convalex-10 and Convoil-20 were fairly complex, with several peaks in the visible region.
In situ measurements of nitric oxide and ozone were carried out at altitudes up to 21 km during two flights of a U-2 aircraft on Dec. 6 and 18, 1973, over the west coast of the United States. A chemiluminescent detector based on the luminescent reaction of nitric acid with excess ozone was used in nitric acid measurements. Ozone concentration measurements were based on the absorption of the Hg line at 2,537 A in the Hartley continuum. The results are compared with available data.
The use of ZnSe to obtain efficient, short wavelength injection luminescence was investigated. It was proposed that shorter wavelength emission and higher efficiency be achieved by employing a p-i-n diode structure rather than the normal p-n diode structure. The intervening i layer minimizes concentration quenching effects and the donor-acceptor pair states leading to long wavelength emission. The surface p layer was formed by ion implantation; implantation of the i layer rather than the n substrate permits higher, uncompensated p-type doping. An ion implanted p-n junction in ZnSe is efficiency-limited by high electron injection terminating in nonradiative recombination at the front surface, and by low hole injection resulting from the inability to obtain high conductivity p-type surface layers. While the injection ratio in p-n junctions was determined by the radio of majority carrier concentrations, the injection ratio in p-i-n structures was determined by the mobility ratios and/or space charge neutrality requirements in the i layer.
A new concept for particle acceleration for micrometeoroid simulation was developed at NASA Marshall Space Flight Center, using a high-density self-luminescent fast plasma flow to accelerate glass beads (with a diameter up to 1.0 mm) to velocities between 15-20 km/sec. After a short introduction to the operation of the hypervelocity range, the eight-converter-camera unit used for the photographs of the plasma flow and the accelerated particles is described. These photographs are obtained with an eight-segment reflecting pyramidal beam splitter. Wratten filters were mounted between the beam splitter and the converter tubes of the cameras. The photographs, which were recorded on black and white film, were used to make the matrices for the dye-color process, which produced the prints shown.
Various types of photomultiplier tubes useful for space applications were irradiated with 1- and 2-MeV electrons at Van Allen radiation belt fluxes of 100,000 to 10 millions electrons/sq cm-sec. The increase in the dark current due to electron irradiation was observed at various bias voltages under worst-case conditions (no shielding). Results were presented in the form of dark current plotted against electron flux. All the tubes tested showed extremely large increases in dark current. Tube types 541A, 6217, 6199, and 6903 exhibited the largest increases under irradiation, whereas type 1P22 was affected the least. All the damage observed was transient. The luminescence produced in the optical window probably accounts for a large part of the dark-current increases, but there were some effects possibly due to direct irradiation of the photocathode and dynode chain.
The contributions of Cerenkov emission, luminescence, secondary electron emission, and bremsstrahlung to radiation-induced data current and noise of multiplier phototubes were analyzed quantitatively. Fluorescence and Cerenkov emission in the tube window are the major contributors and can quantitatively account for dark count levels observed in orbit. Radiation-induced noise can be minimized by shielding, tube selection, and mode of operation. Optical decoupling of windows and cathode (side-window tubes) leads to further reduction of radiation-induced dark counts, as does reducing the window thickness and effective cathode area, and selection of window/cathode combinations of low fluorescence efficiency. In trapped radiation-free regions of near-earth orbits and in free space, Cerenkov emission by relativistic particles contributes predominantly to the photoelectron yield per event. Operating multiplier phototubes in the photon (pulse) counting mode will discriminate against these large pulses and substantially reduce the dark count and noise to levels determined by fluorescence.
The principal effect of thermal and optical treatments in an ionic solid is to alter the lattice defect equilibrium, including the concentration and arrangement of ion vacancies, impurities, impurity-vacancy associates, and assorted electrons and holes which may be associated with such defects. This paper examines the relationship between these defects and thermoluminescence in the case of lithium fluoride at and above room temperature. The discussion focuses on lattice defect equilibrium, thermoluminescent trapping centers, the relationship between recombination and luminescence, the supralinearity and sensitization of the dosimetry grade of LiF and activation energy parameters.
Four examples of specific fiber optic sensor system designs, each of which demonstrates a different optical modulation format, are described. The birefrigent temperature transducer illustrates direct digital signal modulation. The temperature/pressure dependent semiconductor filter illustrates high-pass optical wavelength signal encoding. The coupled polarized-mode transducer shows how a solid-state sensor can produce narrow-bandpass optical wavelength signal encoding. The luminescent temperature sensor illustrates a way to construct a solid state sensor in order to produce pulse width modulation of an optical signal.
A method and apparatus for removing porphyrins from a fluid sample which are unrelated to the number of bacteria present in the sample and prior to combining the sample with luminol reagent to produce a light reaction is disclosed. The method involves a pre-incubation of the sample with a dilute concentration of hydrogen peroxide which inactivates the interfering soluble porphyrins. Further, by delaying taking a light measurement for a predetermined time period after combining the hydrogen peroxide-treated water sample with a luminol reagent, the luminescence produced by the reaction of the luminol reagent with ions present in the solution, being short lived, will have died out so that only porphyrins within the bacteria which have been released by rupturing the cells with the sodium hydroxide in the luminol reagent, will be measured. The measurement thus obtained can then be related to the concentration of live and dead bacteria in the fluid sample.
A model is proposed to account for the observed properties of Io. The crust is probably siliceous, but the outermost visible surface is composed primarily of several allotropes of elemental sulfur, plus frosts of SO2, H2S, and S2O. The 4-micron feature in Io's IR reflectance is identified as the (nu 1 + nu 3) band of SO2 frost. A possible source of the S is dissociation of iron sulfide brought up from the core by mantle convection. The SO2 is produced in the volcanoes, and the H2S by interaction of magnetospheric protons with the surface S. Delayed luminescence from S2O could cause the posteclipse brightening. The orbital torus is sustained by evaporation from molten ejecta from the volcanoes. Several additional diagnostic absorption bands and two additional minor torus species are predicted by this model.
An experimental evaluation of a swirl-stabilized combustor is presented. The combustor is composed of two confined, concentric, swirling jets. The inner jet flow is lean premixed methane and air; the outer flow is air. Combustion is stabilized on a swirl-induced recirculation zone. Mean temperature and mean concentrations of major species are measured throughout the combustor, including the recirculation zone. Fine wire thermocouples are used to measure temperature. A gas chromatograph and a chemi-luminescence analyzer are employed to analyze samples extracted by a water-cooled gas-sampling probe. Results are presented in the form of isotherms and isopleths of species concentration in the combustor for two swirl conditions: co-swirl and counter-swirl. The effects of swirl on the combustion are discussed in light of flame quenching due to rapid dilution and cooling of the reacting inner jet flow by mixing with the outer flow. Evidence for probe induced perturbations of the combustion process is observed.
Serum samples obtained from 15 astronauts before and after spaceflights were studied with the use of the indirect immunofluorescent method. In seven astronauts antibodies to different elements of the human heart muscle appeared after flights. Strong and very strong luminescence of the elements of heart muscle tissue was detected in the astronauts after the third space flight. In a study of the sera on sections of bovine heart muscle tissue the reactions of the sera taken before and after flight were found to show no essential differences.