Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOADS - PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Power-to-load balancing for asymmetric heave wave energy converters with nonideal power take-off

The aim of this study is to maximize the power-to-load ratio for asymmetric heave wave energy converters. Linear hydrodynamic theory was used to calculate bounds of the expected time-averaged power (TAP) and corresponding surge-restraining force, pitch-restraining torque, and power take-off (PTO) control force with the assumption of sinusoidal displacement. This paper formulates an optimal control problem to handle an objective function with competing terms in an attempt to maximize power capture while minimizing structural and actuator loads in regular and irregular waves. Penalty weights are placed on the surge-restraining force, pitch-restraining torque, and PTO actuation force, thereby allowing the control focus to concentrate on either power absorption or load mitigation. The penalty weights are used to control peak structural and actuator loads that were found to curb the additional losses in power absorption associated with a nonideal PTO. Thus, in achieving these goals, a per-unit gain in TAP would not lead to a greater per-unit demand in structural strength, hence yielding a favorable benefit-to-cost ratio. Demonstrative results for 'The Berkeley Wedge' in the form of output TAP, reactive TAP needed to drive WEC motion, and the amplitudes of the surge-restraining force, pitch-restraining torque, and PTO control force are shown.

16 TIDAL AND WAVE POWER↗

Loading across the Periodic Table: Introducing 14 Different Metal Ions To Enhance Metal–Organic Framework Performance

Loading metal guests within metal–organic frameworks (MOFs) via secondary functional groups is a promising route for introducing or enhancing MOF performance in various applications. In this work, 14 metal ions (Li + , Na + , K + , Mg 2+ , Ca 2+ , Ba 2+ , Zn 2+ , Co 2+ , Mn 2+ , Ag + , Cd 2+ , La 3+ , In 3+ , and Pb 2+ ) have been successfully introduced within the MIL-121 MOF using a cost-efficient route involving free carboxylic groups on the linker. The local and long-range structure of the metal-loaded MOFs is characterized using multinuclear solid-state NMR and X-ray diffraction methods. We note Li/Mg/Ca-loaded MIL-121 and Ag nanoparticle-loaded MIL-121 exhibit enhanced H 2 and CO 2 adsorption; Ag nanoparticle-loaded MIL-121 also demonstrates remarkable catalytic activity in the reduction of 4-nitrophenol.

36 MATERIALS SCIENCE↗

Designing Lithium–Sulfur Batteries with High-Loading Cathodes at a Lean Electrolyte Condition

Developing lithium–sulfur cells with a high-loading cathode at a lean-electrolyte condition is the key to bringing the lithium–sulfur technology into the energy-storage market. However, it has proven to be extremely challenging to develop a cell that simultaneously satisfies the abovementioned metrics while also displaying high electrochemical efficiency and stability. Here, we present a concept of constructing a conductive cathode substrate with a low surface area and optimized nanoporosity (i.e., limited micropores in the porous matrix) that enables achieving a high sulfur loading of 13 mg cm –2 and a high sulfur content of 75 wt % with an extremely low electrolyte/sulfur ratio of just 4.0 μL mg –1 . The high-loading nanocomposite cathodes demonstrate high-areal capacities of 9.3 mA h cm –2 , high energy densities of 18.6 mW h cm –2 , and superior cyclability with excellent capacity retention of 85% after 200 cycles. These values are higher than the benchmarks set up for developing future commercial lithium–sulfur cells (i.e., areal capacity of >2–4 mA h cm –2 , energy density of >8–13 mW h cm –2 , and a long cycle life of 200 cycles with a capacity retention of 80%). The cathode design further exhibits high-rate capability from C/20 to 1 C rates and great potential to attain ultrahigh sulfur loading and a content of 17 mg cm –2 and 80 wt %. Furthermore, the key nanostructural feature that enables realizing fast-charge transport is the low surface area and limited microporosity that avoid the fast consumption of the electrolyte during cell cycling.

25 ENERGY STORAGE↗

QUASI-ISENTROPIC COMPRESSION OF MATERIALS USING THE MAGNETIC LOADING TECHNIQUE

The magnetic loading technique using pulsed power generators was first developed about a decade ago on the Z Accelerator, and has matured significantly. The recent development of small, pulsed power generators have enabled several key issues in isentropic compression experiments (ICE), such as panel design, sample preparation, and uniformity of loading to be studied. Veloce is a medium-voltage, high-current, compact pulsed power generator developed for cost effective isentropic experiments. The machine delivers approx2.5 MA of current rapidly (approx440-530 ns) into an inductive load where significant magnetic pressures are produced. Examples of recent material strength measurements from quasi-isentropic loading and unloading of materials are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical analysis of laser-driven reservoir dynamics for shockless loading

Laser-driven plasma loader for shockless compression provides a new approach to study the rapid compression response of materials not attainable in conventional shock experiments. In this method, the strain rate is varied from {approx}10{sup 6}/s to {approx}10{sup 8}/s, significantly higher than other shockless compression methods. Thus, this loading process is attractive in the research of solid material dynamics and astrophysics. The objective of the current study is to demonstrate the dynamic properties of the jet from the rear surface of the reservoir, and how important parameters such as peak load, rise time, shockless compression depth, and stagnating melt depth in the sample vary with laser intensity, laser pulse length, reservoir thickness, vacuum gap size, and even the sample material. Numerical simulations based on the space-time conservation element and solution element method, together with the bulk ablation model, were used. The dynamics of the reservoir depend on the laser intensity, pulse length, equation of state, as well as the molecular structure of the reservoir. The critical pressure condition at which the reservoir will unload, similar to a gas or weak plasma, is 40-80 GPa before expansion. The momentum distribution bulges downward near the front of the plasma jet, which is an important characteristic that determines shockless compression. The total energy density is the most important parameter, and has great influence on the jet characteristics, and consequently on the shockless compression characteristics. If the reservoir is of a single material irradiated at a given laser condition, the relation of peak load and shockless compression depth is in conflict, and the highest loads correspond to the smallest thickness of sample. The temperature of jet front runs up several electron volts after impacting on the sample, and the heat transfer between the stagnating plasma and the sample is sufficiently significant to induce the melting of the sample surface. However, this diffusion heat wave propagates much more slowly than the stress wave, and has minimal effect on the shockless compression progress at a deeper position.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The deformation and acoustic emission of aluminum-magnesium alloy under non-isothermal thermo-mechanical loading

The following study investigates the deformation behavior and acoustic emission in aluminum-magnesium alloy under conditions of non-isothermal thermo-mechanical loading. The accumulation of deformation in the alloy, in conditions of change from room temperature to 500°C, occurs in two temperature intervals (I, II), characterized by different rates of deformation. The rate of deformation accumulation is correlated with acoustic emission. With load increasing in cycles from 40 to 200 MPa, the value of the boundary temperature (T{sub b}) between intervals I and II changes non-monotonically. In cycles with load up to 90 MPa, the T{sub b} value increases, while an increase up to 200 MPa makes T{sub b} shift toward lower temperatures. This suggests that the shift of boundaries in the region of low temperatures and the appearance of high-amplitude pulses of acoustic emission characterize the decrease of the magnitude of thermal fluctuations with increasing mechanical load, leading to the rupture of interatomic bonds in an elementary deformation act.

36 MATERIALS SCIENCE↗

Heat load of a GaAs photocathode in an SRF electron gun

A great deal of effort has been made over the last decades to develop a better polarized electron source for high energy physics. Several laboratories operate DC guns with a gallium arsenide photocathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved by using a superconducting radio frequency (SRF) electron gun, which delivers beams of a higher brightness than that from DC guns because the field gradient at the cathode is higher. SRF guns with metal and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since a bulk gallium arsenide (GaAs) photocathode is normal conducting, a problem arises from the heat load stemming from the cathode. In this paper, we present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and verification by measuring the quality factor of the gun with and without the cathode at 2 K. We simulate heat generation and flow from the GaAs cathode using the ANSYS program. Finally, by following the findings with the heat load model, we designed and fabricated a new cathode holder (plug) to decrease the heat load from GaAs.

2 K test↗

OC6 Phase I: Investigating the underprediction of low-frequency hydrodynamic loads and responses of a floating wind turbine

Phase I of the OC6 project is focused on examining why offshore wind design tools underpredict the response (loads/motion) of the OC5-DeepCwind semisubmersible at its surge and pitch natural frequencies. Previous investigations showed that the underprediction was primarily related to nonlinear hydrodynamic loading, so two new validation campaigns were performed to separately examine the different hydrodynamic load components. In this paper, we validate a variety of tools against this new test data, focusing on the ability to accurately model the low-frequency loads on a semisubmersible floater when held fixed under wave excitation and when forced to oscillate in the surge direction. However, it is observed that models providing better load predictions in these two scenarios do not necessarily produce a more accurate motion response in a moored configuration.

17 WIND ENERGY↗

Comparison of loads from HAWC2 and OpenFAST for the IEA Wind 15 MW Reference Wind Turbine

Reference wind turbines (RWTs) that reflect the state-of-the-art of current wind energy technology are necessary in order to properly evaluate innovative methods in wind turbine design and evaluation. The International Energy Agency (IEA) Wind Technology Collaboration Platform (TCP) Task 37 has recently developed a new RWT geared towards offshore floating-foundation applications: the IEA Wind 15 MW. The model has been implemented in two aeroelastic codes, OpenFAST and HAWC2, based on an underlying common ontology. However, these toolchains result in slightly different structural parameters, and the two codes utilise different structural models. Thus, to increase the utility of the model, it is necessary to compare the aeroelastic responses. This paper compares aeroelastic loads calculated using different fidelities of the blade model in OpenFAST (ElastoDyn and BeamDyn) and HAWC2 (prismatic Timoshenko without torsion and Timoshenko with fully populated stiffness matrix), where both codes use the DTU Basic controller and the same turbulence boxes to reduce discrepancies. The aeroelastic responses to steady wind, step wind and turbulent wind (per IEC 61400-1 wind class IB) are considered. The results indicate a generally good agreement between the loads dominated by aerodynamic thrust and force, especially for the no-torsion blade models. Discrepancies were observed in other load channels, partially due to differences in the asymmetric loading of the rotor and partially due to differing closed-loop dynamics, and they will be the subject of future investigations.

17 WIND ENERGY↗

Implementation of Advanced Grid Support Functionalities by Smart Operation of Residential Loads with low Cost Converter Interface

This paper investigates a grid-supportive load concept for small-scale residential appliances, focusing on a residential refrigerator. Power consumption is adjusted based on grid conditions to achieve IEEE-1547 grid support functions. Two key aspects are presented: a low-cost refrigerator converter with Lyapunov energy function-based local controllers for speed control, and the impact on a standard microgrid system, demonstrating advanced grid support from the load side. This method enhances grid resilience and reliability and can be extended to other residential loads. The study contributes to efficient and robust grid-supportive load management systems, showing promising performance. This approach has the potential to improve overall grid stability and can be adapted for various types of residential appliances. The modeling and simulations in MATLAB/Simulink and PLECS confirm the feasibility and effectiveness of the proposed solution. Future work will explore real-world implementation and scalability of this concept for broader applications.

grid supportive loads (GSL)↗

The Future Impact of Wind on BPA Power System Load Following and Regulation Requirements

Wind power is growing in a very fast pace as an alternative generating resource. As the ratio of wind power over total system capacity increases, the impact of wind on various system aspects becomes significant. This paper presents a methodology to study the future impact of wind on BPA power system load following and regulation requirements. Existing methodologies for similar analysis include dispatch model simulation and standard deviation evaluation on load and wind data. The methodology proposed in this paper uses historical data and stochastic processes to simulate the load balancing processes in the BPA power system. It mimics the actual power system operations therefore the results are close to reality yet the study based on this methodology is convenient to perform. The capacity, ramp rate and ramp duration characteristics are extracted from the simulation results. System load following and regulation capacity requirements are calculated accordingly. The ramp rate and ramp duration data obtained from the analysis can be used to evaluate generator response or maneuverability requirement and regulating units’ energy requirement, respectively.

17 WIND ENERGY↗

Balancing Power Absorption Against Structural Loads With Viscous Drag and Power-Takeoff Efficiency Considerations

The focus of this paper is to balance power absorption against structural loading for a novel fixed-bottom oscillating surge wave energy converter in both regular and irregular wave environments. The power-to-load ratio will be evaluated using pseudospectral control (PSC) to determine the optimum power-takeoff (PTO) torque based on a multiterm objective function. This paper extends the pseudospectral optimal control problem to not just maximize the time-averaged absorbed power but also include measures for the surge-foundation force and PTO torque in the optimization. The objective function may now potentially include three competing terms that the optimizer must balance. Separate weighting factors are attached to the surge-foundation force and PTO control torque that can be used to tune the optimizer performance to emphasize either power absorption or load shedding. To correct the pitch equation of motion, derived from linear hydrodynamic theory, a quadratic-viscous-drag torque has been included in the system dynamics; however, to continue the use of quadratic programming solvers, an iteratively obtained linearized drag coefficient was utilized that provided good accuracy in the predicted pitch motion. Furthermore, the analysis considers the use of a nonideal PTO unit to more accurately evaluate controller performance. The PTO efficiency is not directly included in the objective function but rather the weighting factors are utilized to limit the PTO torque amplitudes, thereby reducing the losses resulting from the bidirectional energy flow through a nonideal PTO. Furthermore, results from PSC show that shedding a portion of the available wave energy can lead to greater reductions in structural loads, peak-to-average power ratio, and reactive power requirement.

16 TIDAL AND WAVE POWER↗

Short-Term Forecasting of Thermostatic and Residential Loads Using Long Short-Term Memory Recurrent Neural Networks

Internet of Things (IoT) devices in smart grids enable intelligent energy management for grid managers and personalized energy services for consumers. Investigating a smart grid with IoT devices requires a simulation framework with IoT devices modeling. However, there lack comprehensive study on the modeling of IoT devices in smart grids. This paper investigates the IoT device modeling of a thermostatic load and implements the recurrent neural networks model for short-term load forecasting in this IoT-based thermostatic load. The recurrent neural network structure is leveraged to build a load forecasting model on temporal correlation. The temporal recurrent neural network layers including long short-term memory cells are employed to learn the data from both the simulation platform and New South Wales residential datasets. The simulation results are provided for demonstration.

electric load forecasting↗

Dynamic Data Repartitioning for Load-Balanced Parallel Particle Tracing

We present a novel dynamic load-balancing algorithm based on data repartitioning for parallel particle tracing in flow visualization. Instead of static data assignment, we dynamically repartition the data into blocks and reassign the blocks to processes to balance the workload distribution among the processes. Block repartitioning is performed based on a dynamic workload estimation method that predicts the workload in the flow field on the fly as the input. In our approach, we allow data duplication in the repartitioning, enabling the same data blocks to be assigned to multiple processes. Load balance is achieved by regularly exchanging the blocks (together with the particles in the blocks) among processes according to the output of the data repartitioning. Compared with other load-balancing algorithms, our approach does not need any preprocessing on the raw data and does not require any dedicated process for work scheduling, while it has the capability to balance uneven workload efficiently. Results show improved load balance and high efficiency of our method on tracing particles in both steady and unsteady flow.

data repartitioning↗

Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems

Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast Primary Frequency Response using Coordinated DER and Flexible Loads: Framework and Residential-scale Demonstration

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (~8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Agent Reinforcement Learning for Distribution System Critical Load Restoration

Grid resilience has become a critical topic recently because of the increasing occurrence of extreme events and the growing integration of intermittent renewable energy sources. To build a resilient distribution system, this paper develops a multiagent reinforcement learning-based (MARL) method to coordinate distribution energy resources (DERs) dispatch, load pickup, and network reconfiguration for load restoration after a system outage. With the help of two types of control agents, namely critical load restoration (CLR) and coordination (COR) agents, system loads can be restored efficiently, given available resources. The effectiveness and superiority of the proposed algorithm are demonstrated through simulations and comparative studies on a real distribution feeder in Western Colorado.

distribution system↗

Distributed Load Sharing Under False Data Injection Attack in an Inverter-Based Microgrid

In microgrids, distributed load sharing plays an important role in maintaining the supply-demand balance of power. Because false data injection (FDI) is one of the crucial threats faced by future microgrids, the study of the impact of FDI on distributed load sharing is both of theoretical merit and practical value. Here, we consider the distributed load sharing problem of the microgrids operating in autonomous mode under FDI. Each bus is assumed to be equipped with an agent. Under a well-developed distributed load sharing protocol based on multiagent systems, we first construct an FDI attack model, where the attacker is capable of injecting false data into the bus agents. Finally, a utilization level is introduced for coordinating generators, and its variation is evaluated in the presence of FDI attacks with given injection strategies. The stable region of the microgrid is defined, and conditions are given to determine stability. In conclusion, theoretical results are validated on the Canadian urban distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗