Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LASER OUTPUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

High-power single-element pseudomorphic InGaAs/GaAs/AlGaAs single quantum well lasers for pumping Er-doped fiber amplifiers

A 980-nm-ridge waveguide pseudomorphic InGaAs/GaAs/AlGaAs single-quantum-well laser with a maximum single-ended output power of 240 mW from a facet-coated device is fabricated from a graded-index separate-confinement heterostructure grown by molecular-beam epitaxy. The laser oscillates in the fundamental spatial mode, allowing 22 percent coupling efficiency into a 1.55-micron single-mode optical fiber. Life testing at an output power of 30 mW per facet from uncoated devices reveals a superior reliability to GaAs/AlGaAs quantum-well lasers but also the need for protective facet coatings for long term reliability at power levels required for pumping Er-doped fiber amplifiers.

Larsson, A.↗

Interaction of a finite train of short pulses with an atomic ladder system

When a train of optical pulses interacts with a medium, the time between pulses and the pulse-to-pulse phase jump have a profound effect on the outcome of the interaction. For a near-infinite train of regularly separated pulses having a constant pulse-to-pulse phase jump, as in the output of a frequency comb laser interacting with a ladder system, excitation of that system has been previously calculated and compared with experiment. In that case, the number of pulses in the train is very large, and the energy per pulse is very small. In the present work, the other extreme is experimentally examined: A small number of regularly spaced optical pulses are made to interact with a three-level ladder system in atomic rubidium. The pulses have been amplified, possibly placing the interactions into a nonperturbative regime. The experimental results are compared to a simple intuitive model and found to be in good general agreement. However, some aspects of the experimental results seem to be at odds with the simple model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Properties of AlN films deposited by reactive ion-plasma sputtering

The properties of SiO{sub 2}, Al{sub 2}O{sub 3}, and AlN dielectric coatings deposited by reactive ion-plasma sputtering are studied. The refractive indices of the dielectric coatings are determined by optical ellipsometry. It is shown that aluminum nitride is the optimal material for achieving maximum illumination of the output mirror of a semiconductor laser. A crystalline phase with a hexagonal atomic lattice and oxygen content of up to 10 at % is found by transmission electron microscopy in the aluminum-nitride films. It is found that a decrease in the concentration of residual oxygen in the chamber of the reactive ion-plasma sputtering installation makes it possible to eliminate the appearance of vertical pores in the bulk of the aluminum-nitride film.

36 MATERIALS SCIENCE↗

Conversion of a TEM10 beam into two nearly Gaussian beams

To achieve high output power and/or high efficiencies, laser systems are often designed to operate with either high-order or multiorder transverse modes. This comes at the expense of beam quality. Herein, a technique for converting the two lobes of a higher-order (Hermite–Gaussian TEM10) beam into two TEM00 beams is discussed. It is shown that nearly 94% of the power in a single lobe of the TEM10 beam spatially overlaps an appropriately chosen TEM00 beam. Beam quality (defined by the M2 beam quality factor) is increased by separating the two TEM10 lobes with an edge aperture. A single-mode optical fiber can be used as a spatial filter to eliminate residual higher-order mode content. This study suggests that more than 90% of the power in a TEM10 beam can be converted into two separate TEM00 beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave biasing improves detector response in the infrared region

Detection system, which incorporates advantages of microwave biasing, measures output of a carbon dioxide laser at 10.6 microns with a factor of 1,000 improvement in sensitivity. Material lifetime, rather than external circuitry, limits detector response time.

Sun, C.↗

The NASA high power carbon dioxide laser: A versatile tool for laser applications

A closed-cycle, continuous wave, carbon dioxide high power laser has been designed and fabricated to support research for the identification and evaluation of possible high power laser applications. The device is designed to generate up to 70 kW of laser power in annular shape beams from 1 to 9 cm in diameter. Electric discharge, either self sustained or electron beam sustained, is used for excitation. This laser facility provides a versatile tool on which research can be performed to advance the state-of-the-art technology of high power CO2 lasers in such areas as electric excitation, laser chemistry, and quality of output beams. The facility provides a well defined, continuous wave beam for various application experiments, such as propulsion, power conversion, and materials processing.

Lancashire, R. B.↗

Limitations on the use of laser velocimeter signals for particle sizing

The paper discusses the complex relationship existing between the diameter of a particle, its index of refraction, and the output signal of a fringe-type laser velocimeter, and describes a special purpose laser velocimeter for aerosol sizing that determines aerosol size distributions on the basis of Farmer's (1973) relationship between visibility and particle size. In experiments with particles of known size, this relationship is in qualitative agreement with the experimentally observed results, the main differences being that (1) the visibility does not assume a minimum value of zero, as predicted, and (2) the visibility value above which there is no ambiguity in the corresponding fringe spacing is higher than that predicted.

Orloff, K. L.↗

Magnetically-Switched, Long-Pulse XeCl Laser

Careful shaping of input pulses helps XeCl excimer laser produce lowdivergence, narrow-band light beam. Long-pulse laser achieves narrow-band output by multiple passes of beam through precisely adjusted Fabry-Perot etalons. Pulse-forming network and saturable-inductor switch enable fast pulse rise to peak voltage, followed by long residence at peak.

Pacala, T. J.↗

A signature for the Lorenz instability in quantum optics

The time averaged output power of a Lorenz laser in the self-pulsing and chaotic regime has been numerically examined. The results indicate that the change in average power when unstable behavior occurs are of the order of 1-5 percent. This negligible change could serve as an additional signature of the Lorenz instability in quantum optics.

Lawandy, N. M.↗

Applications of spaceborne laser ranger on EOS

An account is given of the design concept and potential applications in science and engineering of the spaceborne laser ranging and altimeter apparatus employed by the Geodynamics Laser Ranging System; this is scheduled for 1997 launch as part of the multiple-satellite Earth Observing System. In the retrograding mode for geodynamics, the system will use a Nd:YAG laser's green and UV output for distance determination to ground retroreflectors. Engineering applications encompass land management and long-term ground stability studies relevant to nuclear power plant, pipeline, and aqueduct locations.

Degnan, John J.↗

Surface roughness of flat and curved optical surfaces

Surface roughness measurement has several applications. Even a few A roughness will cause scattered light in optical systems. Smooth surfaces are required in a wide variety of instruments. For example, the outputs of the high power lasers are limited by the surface roughness of mirrors and windows. Similarly, the information storage capacity of magnetic media is limited by the roughness of the surface. Roughness reduces the resolving power of optics and distorts images. The performance of certain thin film components in electronic industries is affected by the roughness on the film surface. X-ray astronomical telescopes require smooth curved surfaces. To improve the surface quality, super sensitive detection methods are required. Wide ranging measurement techniques are developed based on interferometry, electron microscopy, C-rays, ellipsometry, light scattering, and using mechanical stylus, etc. Though there are several techniques available for measurement and evaluation of the surfaces, no single technique is fully adequate. Also, the technique used should be nondestructive and highly sensitive. So, an optical heterodyne profilometer was fabricated. Its current sensitivity is much better than 10A rms. It is a noncontact and nondestructive technique. The instrument can be operated even by unskilled personnel for routine measurements.

George, M. C.↗

A wide-band monolithic quasi-optical power meter for millimeter- and submillimeter-wave applications

A novel monolithic power meter has been developed for submillimeter-wave applications (100 GHz to 10 THz). The detector is a large-area bismuth bolometer integrated on a 1.2-micron-thick dielectric membrane. This approach results in a wide-band, high-responsivity detector. The power meter is simple to fabricate, is inexpensive, and can be easily calibrated using a low-frequency network. Quasi-optical measurements at 90, 140, and 240 GHz show that the bolometer is polarization-independent and could be modeled by a simple transmission line model. Absolute power measurements at 90, 140, and 240 GHz show a + or - 5 percent accuracy and agree well with a calibrated Anritsu power meter at 90 GHz. Potential application areas are power calibration, antenna coupling efficiency measurements, and absolute power measurements from solid-state devices and far-infrared lasers at submillimeter wavelengths. Absolute output power measurements on a 220-280 GHz tripler using the quasi-optical power meter are presented as an application example.

Ling, Curtis C.↗

A directed search for extraterrestrial laser signals

The focus of NASA's Search for Extraterrestrial Intelligence (SETI) Program is on microwave frequencies, where receivers have the best sensitivities for the detection of narrowband signals. Such receivers, when coupled to existing radio telescopes, form an optimal system for broad area searches over the sky. For a directed search, however, such as toward specific stars, calculations show that infrared wavelengths can be equally as effective as radio wavelengths for establishing an interstellar communication link. This is true because infrared telescopes have higher directivities (gains) that effectively compensate for the lower sensitivities of infrared receivers. The result is that, for a given level of transmitted power, the signal to noise ratio for communications is equally as good at infrared and radio wavelengths. It should also be noted that the overall sensitivities of both receiver systems are quite close to their respective fundamental limits: background thermal noise for the radio frequency system and quantum noise for the infrared receiver. Consequently, the choice of an optimum communication frequency may well be determined more by the achievable power levels of transmitters rather than the ultimate sensitivities of receivers at any specific frequency. In the infrared, CO2 laser transmitters with power levels greater than 1 MW can already be built on Earth. For a slightly more advanced civilization, a similar but enormously more powerful laser may be possible using a planetary atmosphere rich in CO2. Because of these possibilities and our own ignorance of what is really the optimum search frequency, a search for narrowband signals at infrared frequencies should be a part of a balanced SETI Program. Detection of narrowband infrared signals is best done with a heterodyne receiver functionally identical to a microwave spectral line receiver. We have built such a receiver for the detection of CO2 laser radiation at wavelengths near 10 microns. The spectrometer uses a high-speed HgCdTe diode as the photomixer and a small CO2 laser as the local oscillator. Output signals in the intermediate frequency range 0.1-2.6 GHz are processed by a 1000-channel acousto-optic signal processor. The receiver is being used on a 1.5-m telescope on Mt. Wilson to survey a selected sample of 150 nearby stars. The current status of the work is discussed along with future project plans.

Betz, A.↗

Collisional Removal of OH (X (sup 2)Pi, nu=7) by O2, N2, CO2, and N2O

Collisional removal rate constants for the OH (X 2PI, nu = 7) radical are measured for the colliders O2, CO2, and N2O, and an upper limit is established for N2. OH(nu = 4) molecules, generated in a microwave discharge flow cell by the reaction of hydrogen atoms with ozone, are excited to v = 7 by the output of a pulsed infrared laser via direct vibrational overtone excitation. The temporal evolution of the P = 7 population is probed as a function of the collider gas partial pressure by a time-delayed pulsed ultraviolet laser. Fluorescence from the B 21 + state is detected in the visible spectral region.

Knutsen, Karen↗

Digital Receiver Phase Meter

The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density <5 microcycle/(Hz)1/2 and to be capable of determining the power spectral density of the phase difference over the frequency range from 1 mHz to 1 Hz. Such a phase meter could also be used on Earth to perform similar measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.

Marcin, Martin↗

Optically pumped alkali laser and amplifier using helium-3 buffer gas

In one embodiment, a laser oscillator is provided comprising an optical cavity, the optical cavity including a gain medium including an alkali vapor and a buffer gas, the buffer gas including .sup.3He gas, wherein if .sup.4He gas is also present in the buffer gas, the ratio of the concentration of the .sup.3He gas to the .sup.4He gas is greater than 1.37.times.10.sup.-6. Additionally, an optical excitation source is provided. Furthermore, the laser oscillator is capable of outputting radiation at a first frequency. In another embodiment, an apparatus is provided comprising a gain medium including an alkali vapor and a buffer gas including .sup.3He gas, wherein if .sup.4He gas is also present in the buffer gas, the ratio of the concentration of the .sup.3He gas to the .sup.4He gas is greater than 1.37.times.10.sup.-6. Other embodiments are also disclosed.

Beach, Raymond J↗

Method and system for laser-based formation of micro-shapes in surfaces of optical elements

A method of forming a surface feature extending into a sample includes providing a laser operable to emit an output beam and modulating the output beam to form a pulse train having a plurality of pulses. The method also includes a) directing the pulse train along an optical path intersecting an exposed portion of the sample at a position i and b) focusing a first portion of the plurality of pulses to impinge on the sample at the position i. Each of the plurality of pulses is characterized by a spot size at the sample. The method further includes c) ablating at least a portion of the sample at the position i to form a portion of the surface feature and d) incrementing counter i. The method includes e) repeating steps a) through d) to form the surface feature. The sample is free of a rim surrounding the surface feature.

36 MATERIALS SCIENCE↗