Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Exploring the Birth and Evolution of the Universe: How Detectors Have Revolutionized Space Astronomy

The past century has seen tremendous advances in the capability of instruments used for astronomical imaging and spectroscopy. Capabilities of instruments have expanded in many dimensions; the scale of telescopes has grown tremendously, the wavelengths used for astronomy have grown from visible light to the full electromagnetic spectrum, extending from gamma rays to low frequency radio waves. Additional advances have been enabled by the availability of space facilities, which eliminate the effects of the earths atmosphere and magnetosphere, and allow cooling of instruments to avoid instrumental thermal radiation. Even with all these advances, the increase in capability of detection systems has produced truly revolutionary improvements in capability. Today, I will describe the advances in astronomical detection from the photographic plates of the early 20th century to the giant high efficiency focal planes being developed for modern space and ground based astronomical instrument. I will review the demanding performance requirements set by space astronomy, and show how the detector community has risen to the challenge in producing high performance detectors for the Hubble Space Telescope, the Spitzer Space Telescope, and the James Webb Space Telescope, now under development.

Moseley, Samuel H.↗

Nephelometer Instrument Handbook

The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

47 OTHER INSTRUMENTATION↗

SpecFIDLER User Manual: Software Version 2.4.0

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.5.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.6.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.3.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Comparison of the MODIS and VIIRS On-Board SD and SDSM Performance

The MODIS reflective solar bands (RSB) are calibrated on-orbit using a solar diffuser (SD) with its on-orbit degradation, or change in the bi-directional reflectance factor (BRF) monitored using a solar diffuser stability monitor (SDSM). By performing alternate observations of direct sunlight via an attenuation screen and of sunlight reflected diffusely off the SD, the SDSM monitors the on-orbit degradation of the SD. The MODIS SDSM has 9 detectors, covering wavelengths from 0.41 to 0.94 microns. Both Terra and Aqua MODIS instruments have successfully operated for more than 16 years on-orbit, with the SD experiencing significant degradation at the shortest wavelength (about 50 percent for Terra MODIS and about 20 percent for Aqua MODIS at 0.41 microns). The first VIIRS instrument on the Suomi NPP spacecraft was launched in October 2011 and the follow-on instrument was launched in November 2017 on the JPSS-1 spacecraft (now NOAA-20). Both the VIIRS instruments carry a MODIS-like SD and SDSM system with an improved design based on the lessons learned from MODIS. Unlike MODIS, the VIIRS SDSM collects data using 8 detectors covering a similar wavelength range as MODIS. A similar wavelength dependent SD degradation pattern is also observed in both VIIRS instruments. This paper provides a comparison of the on-orbit performance of the four instruments in terms of the on-orbit changes in the SDSM detector responses and on-orbit degradations of their SDs. The NOAA-20 VIIRS instrument is still in its first year of operation and hence the early performance of the Terra and Aqua MODIS and SNPP VIIRS is discussed to provide a perspective comparison.

VIIRS↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

The MERiT Onboard the CeREs: A Novel Instrument to Study Energetic Particles in the Earth's Radiation Belts

The Miniaturized Electron pRoton Telescope, MERiT, is a low‐mass, low‐power, compact instrument using an innovative combination of particle detectors, sensor electronics, and onboard processing. MERiT is flying on the Compact Radiation belt Explorer, CeREs, a 3U CubeSat launched into a low earth orbit of 500‐km altitude and inclination of 85° on 16 December 2018. The primary and secondary science goals of CeREs are to investigate electron microbursts and to study solar particles. MERiT comprises a stack of solid state detectors (SSD) behind space facing avalanche photo diodes (APDs) surrounded by W‐Al shielding to reduce side‐penetrating particle background. The APD‐SSD combination enables measurement of electrons from 5 to 200 keV and 1 to 8 MeV; protons from 200–400 keV and 7–100 MeV in differential channels with energy resolution ΔE/E≈30% for both electrons and protons. MERiT measures microbursts with a high time resolution ranging from 4 to 16 ms and solar particles with a cadence of 1 s. MERiT energy channels and cadences are software configurable via algorithms and lookup tables residing on a field‐programmable gate array. The lookup tables can be changed via ground commands. MERiT geometry factor is 31 sq.cm‐sr and optimized to measure microbursts with the instrument viewing the local zenith in orbit. MERiT enables investigation of dynamical processes of radiation belt electron energization and loss, solar electron and proton transport, and their access to the Earth's polar caps. We describe the MERiT sensor design, calibration, operational modes, data products, and science goals.

Kanekal, S. G.↗

Encke flyby science package

Cometary exploration objectives are considered, giving attention to reasons for the selection of Encke as a target for early exploration missions. An Encke environmental model is discussed together with the scientific requirements of an exploratory mission, instrument selection criteria, and the science payload. The instruments to be used include a television camera, an IR radiometer, a UV spectrometer, a mass spectrometer, a Sisyphus dust detector, devices for the measurement of the EM field, and instruments for the determination of plasma characteristics. It is pointed out that solar electric propulsion affords the only practical, currently available means of reaching Encke with the desired encounter velocity below 7.5 km/sec.

Newburn, R. L.↗

Spectroscopy in the 10 keV to 10 MeV range

Spectral lines in the 10 keV to 1 MeV range carry information of fundamental importance on many astronomical objects. Since the lines are directly related to specific physical processes this information is model independent and gives the physical conditions in the objects. At the sensitivities achieved to date, approximately 0.0001 to 0.001 phsq cm. sec for steady sources and approximately 0.01 to 1 ph/sq cm sec for transient sources, lines were detected from the galactic center, gamma-ray bursts and transients, X-ray pulsators, the Crab pulsar and solar flares. Future instruments with a factor of approximately 100 sensitivity improvement will allow detailed spectroscopic study of these classes of objects as well as supernova remnants, active galaxies and the interstellar medium. This sensitivity improvement can be obtained through the use of detector technology already proven in balloon and satellite instruments.

Matteson, J. L.↗

Cryogenic Detector Technology for Space Science Application

We review the current status of detector development at NASA's Goddard Space Flight Center and address future prospect for space science application. In particular, the IR detector capability and applicability to second generation SOFIA instrument will be discussed. We will examine areas such as 3-dimensional hybridization of large format bolometer arrays to readout multiplexers; advanced light coupling scheme for planar ortho-mode transducer circuitry; integration of high density readout wiring for low temperature detector arrays; and microwave multiplexers for large format superconducting detector arrays.

Ting-Wen, Hsieh↗

Overview on Shielding Analyses for the VENUS Instrument at SNS

VENUS, a world‐class versatile neutron imaging instrument, is under construction and is expected to be completed and ready to start commissioning in 2023. The range of cold to epithermal neutrons at SNS will give users of VENUS access to novel imaging methods, as well as to significantly improved existing methods. The instrument is being built on beam line 10 at Spallation Neutron Source (SNS) First Target Station (FTS) facing a decoupled poisoned hydrogen moderator. Instrument design, which includes optics, Front-End components and instrument enclosure components and shape started over 10 years ago and during this time had significant changes. All changes were supported by neutronics analyses to provide adequate shielding for both Front-End and instrument enclosure.Final optics design will provide the field of view (FOV) at the detector position (where the image is formed) to be as high as 0.20 by 0.20 m. Both the beam, which contains a large fraction of high-energy neutrons, and the desire for a large footprint on the detector are challenges for shielding design and budget, because the driving cost for the instrument is the beam line and enclosure shielding. For cost reason VENUS baseline design is optimized with respect to both the instrument cave footprint and its wall thickness, and Front-End shielding is tailored along the beam. Analyses are performed with the Monte Carlo particle transport code MCNPX version 2.7.0 to make choices on materials, thicknesses and configurations of the shielding. Numerous calculations are performed to meet space and coast constrain and to satisfy instrument physics needs and to comply with radiation protection requirements.

Gallmeier, Franz X.↗

Advanced technical developments in support of scientific experiments in space

A technique was developed for preparing solid state, lithium-drifted silicon detectors. Hollow cylindrical detectors were built and tested for possible use as anticoincidence shields to replace conventional plastic scintillators and photomultipliers. A fission cell was developed for the Pioneer F/G instruments and the IMP I subsystem. An electron current detector was developed for Jovian belt measurements of electron flux. A number of circuits and semiconductor devices was also developed.

Lamport, J. E.↗

The measured radiation environment within Spacelabs 1 and 2 and comparison with predictions

A set of passive and active radiation detectors was flown as part of the verification flight instrumentation (VFI) in an attempt to measure the radiation environment in the Spacelab (SL) module and on the pallet. SL 1 carried 4 passive and 2 active detector packages which were used to evaluate the radiation environment within the spacecraft and SL 2 carried 2 passive VFI units on the pallet. Dose equivalents of 330 + or - 70 mrem and 537 + or - 37 mrem were measured in the SL 1 module and SL 2 pallet, respectively.

Parnell, T. A.↗

High-Energy Radiation from Thunderstorms with ADELE: TGFs, Steps, and Glows

The biggest challenge in the study of high-energy processes in thunderstorms is getting a detector to the vicinity of the electrically active regions of a storm. The Airborne Detector for Energetic Lightning Emissions (ADELE) has been used to detect gamma rays from aircraft above storms and from a storm-chasing van on the ground. In August 2009, ADELE flew above Florida storms in a Gulfstream V jet, detecting the first terrestrial gamma-ray flash (TGF) seen from a plane and continuous glows of high-energy emission above thunderclouds. The presence of these glows suggests that a gradual process of relativistic runaway and feedback may help limit the total amount of charging in thunderstorms, in contrast to the traditional view that only lightning discharges compete with the charging process. The upper limits on TGF emission from intracloud and cloud-to-ground lightning from the ADELE flights demonstrated conclusively that a TGF of the sort seen from space is not associated with most lightning and not necessary to trigger it. In August 2010, observations from a van detected stepped-leader x-ray emission from at least four lightning strikes in ten days of operations. This mode of operation is therefore promising for future observations of the stepping process, although a more varied suite of instrumentation, in particular a flash-distance detector, would be useful. We will report on these results and on future possibilities for ADELE campaigns.

Smith, David M.↗