Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Systems, method and computer-accessible medium for providing balanced asymmetric interferometry for vibrationally isolated optical scanning probe(s)

An exemplary apparatus can provide radiation to a sample(s), which can include, for example, a radiation source arrangement configured to provide radiation, a beam splitter configured to split the radiation into (i) a first radiation, and (ii) a second radiation. An optical element can also be provided which, in operation, can, e.g., (a) receive the first radiation and the second radiation, (b) reflect the first radiation as a reference radiation, (c) provide the second radiation as illumination for the sample(s), (d) receive a resultant radiation from the sample(s) that can be based on the illumination from the second radiation, and (e) provide the reference radiation and the resultant radiation to be detected and used for interferometric imaging or spectroscopy.

McLeod, Alexander Swinton↗

Double-walled containment cell

Double-walled containment cells are described as may be used for storage, transport, and examination of a sample held within the cell by use of optical analysis techniques. A double-walled containment cell can include multiple types of windows that can be located as desired on the containment cells and thereby provide for optical access to a sample for multiple optical analysis techniques. Disclosed containment cells can be sized and designed for use with existing optical analysis systems, e.g., laser ablation, X-ray diffraction, spectral analysis (e.g., Raman spectroscopy, infrared spectroscopy, laser-induced breakdown spectroscopy, etc.), imaging analysis, etc.

Villa-Aleman, Eliel↗

Goniometric and Polarized Imaging Spectroscopic Lab Measurements of Spacecraft Materials

To better characterize the spectral response of common spacecraft materials, the following laboratory measurements are presented to support the Space Situational Awareness community in the analysis of remotely sensed observational data. Of interest is classifying material reflective properties using directional reflectance spectroscopy and spatially resolved polarized imaging spectroscopy, allowing laboratory data to be applicable to ground-based optical telescope observations. The team acquired a typical CubeSat solar panel and a sample of multi-layer insulation (MLI) commonly used on spacecraft for initial measurements. The directional spectral data were collected at the Goniometer of the Rochester Institute of Technology (GRIT) laboratory with a lab and field goniometer incorporating two AnalyticalSpectral Device (ASD) spectrometers, a small Lab sphere integrating sphere also paired with an ASD spectrometer, and a Headwall micro-Hyperspec E-Series imaging spectrometer with an adjustable linear polarizer. The goniometer measures spectral bi-directional reflectance factor (BRF) data over a broad range from 350−2500 nm at 1 nm spacing with 3 nm spectral resolution in the visible and near infrared and 8 nm in the shortwave infrared. With the same spectral capabilities, the integrating sphere measures hemispherical-directional reflectance (HDR) in a 45◦-nadir configuration. The Headwall imager covers a spectral range from 400−1000 nm with 1.6 nm spectral resolution.Our initial BRF measurements show interference effects for both materials typically observed with thin films and high infrared reflectivity. In contrast, the interference effects are not present in the HDR measurements of the MLI likely due to the interference effects being averaged out over the reflecting hemisphere. Spatially resolved polarization ratio maps show variability across the materials due to the varying surface structure. We outline a plan for expanding our analysis to a broader range of materials to characterize their directional reflectance spectroscopy.

Chris H. Lee↗

Capabilities, Performance, and Status of the SOFIA Science Instrument Suite

The Stratospheric Observatory for Infrared Astronomy (SOFIA) is an airborne observatory, carrying a 2.5 m telescope onboard a heavily modified Boeing 747SP aircraft. SOFIA is optimized for operation at infrared wavelengths, much of which is obscured for ground-based observatories by atmospheric water vapor. The SOFIA science instrument complement consists of seven instruments: FORCAST (Faint Object InfraRed CAmera for the SOFIA Telescope), GREAT (German Receiver for Astronomy at Terahertz Frequencies), HIPO (High-speed Imaging Photometer for Occultations), FLITECAM (First Light Infrared Test Experiment CAMera), FIFI-LS (Far-Infrared Field-Imaging Line Spectrometer), EXES (Echelon-Cross-Echelle Spectrograph), and HAWC (High-resolution Airborne Wideband Camera). FORCAST is a 540 m imager with grism spectroscopy, developed at Cornell University. GREAT is a heterodyne spectrometer providing high-resolution spectroscopy in several bands from 60240 m, developed at the Max Planck Institute for Radio Astronomy. HIPO is a 0.31.1 m imager, developed at Lowell Observatory. FLITECAM is a 15 m wide-field imager with grism spectroscopy, developed at UCLA. FIFI-LS is a 42210 m integral field imaging grating spectrometer, developed at the University of Stuttgart. EXES is a 528 m high-resolution spectrograph, developed at UC Davis and NASA ARC. HAWC is a 50240 m imager, developed at the University of Chicago, and undergoing an upgrade at JPL to add polarimetry capability and substantially larger GSFC detectors. We describe the capabilities, performance, and status of each instrument, highlighting science results obtained using FORCAST, GREAT, and HIPO during SOFIA Early Science observations conducted in 2011.

SOFIA↗

Velocity-Map Imaging and Magnetic-Bottle Photoelectron Spectroscopy of [SeCCH] – : Electronic Properties and Spin–Orbit Splitting

In this work, the recently synthesized acetylide compound KSeCCH containing the main group element selenium within the novel and in crystalline form unprecedented [SeCCH] – anion was successfully investigated in the gas phase by high-resolution velocity-map imaging (VMI) and magnetic-bottle (MB) photoelectron spectroscopy coupled with an electrospray ionization source. Both VMI and MB spectra exhibited identical electron affinities (EA, 2.517 ± 0.002 eV), spin–orbit coupling (SOC) splittings (1492 ± 20 cm –1 ), and Se–C stretching frequencies (573 ± 20 cm –1 ) of the corresponding neutral tetra-atomic radical [SeCCH] • with the VMI spectrum possessing six times higher spectral resolution compared with the MB spectrum. These experimental values were well reproduced by calculations at the CCSD(T) level, in which both the isolated [SeCCH] – anion and the [SeCCH] • radical adopted linear geometries. The simulated spectra based on the calculated Franck–Condon factors, the SOC splitting, and the experimental line width matched well with the measured spectra. Furthermore, comparisons of the EA and SOC splitting values with the previously reported isolobal species [SeCN] • are also made and discussed. The decrease in the EA and SOC splitting of [SeCCH] • is ascribed to the differences in the electronegativities between C and N atoms as well as the electron density on the Se atom in its singly occupied molecular orbital (SOMO).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Instrument of the Imaging X-Ray Polarimetry Explorer

While X-ray spectroscopy, timing, and imaging have improved much since 1962 when the first astronomical nonsolar source was discovered, especially wi the launch of the Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer, and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, which in turn is a result of the fate of approved missions and because celestial X-ray sources appear less polarized than expected. Only one positive measurement has been available until now: the Orbiting Solar Observatory measured the polarization of the Crab Nebula in the 1970s. The advent of microelectronics techniques has allowed for designing a detector based on the photoelectric effect of gas in an energy range where the optics are efficient at focusing in X-rays. Here we describe the instrument, which is the major contribution of the Italian collaboration to the Small Explorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will launch in late 2021. The instrument is composed of three detector units based on this technique and a detector service unit. Three mirror modules provided by Marshall Space Flight Center focus X-rays onto the detectors. We show the technological choices, their scientific motivation, and results from the calibration of the instrument. IXPE will perform imaging, timing, and energy-resolved polarimetry in the 2–8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Density Polyethylene Custom Focusing Lenses for High-Resolution Transient Terahertz Biomedical Imaging Sensors

Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.

47 OTHER INSTRUMENTATION↗

National Diagnostic Working Group (NDWG) for inertial confinement fusion (ICF)/high-energy density (HED) science: The whole exceeds the sum of its parts

The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. Here, an abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.

47 OTHER INSTRUMENTATION↗

Characterization of Single-Sided Charge-Sharing CZT Strip Detectors for Gamma-Ray Astronomy

We report progress in the study of thick single-sided charge-sharing cadmium zinc telluride (CZT) strip detector modules designed to perform spectroscopy and 3-D imaging of gamma-rays. We report laboratory measurements including spectroscopy, efficiency and 3-D imaging capability of prototype detectors (15 15 7.5 cu mm) with 11x11 unit cells. We also report on Monte Carlo simulations (GEANT4 v7.1) to investigate the effect of multihits on detector performance in both spectroscopy and imaging. We compare simulation results with data obtained from laboratory measurements and discuss the implications for future strip detector designs. Keywords: CZT, strip detectors, gamma-ray

Donmez, Burcin↗

Distribution of Mn Oxidation States in Grassland Soils and Their Relationships with Soil Pores

Manganese (Mn) is known to be an active contributor to processing and cycling of soil organic carbon (C), yet the exact mechanisms behind its interactions with C are poorly understood. Plant diversity in terrestrial ecosystems drives feedback links between plant C inputs and soil pores, where the latter, in turn, impact the redox environment and Mn. This study examined associations between soil pores (>36 μm Ø) and Mn within intact soils from two grassland ecosystems, after their >6-year implementation in a replicated field experiment. In this work, we used μ-XRF imaging and XANES spectroscopy to explore spatial distribution patterns of Mn oxidation states, combined with X-ray computed microtomography and 2D zymography. A high plant diversity system (restored prairie) increased soil C and modified spatial distribution patterns of soil pores as compared to a single species system (monoculture switchgrass). In switchgrass, the abundance of oxidized and reduced Mn oxidation states varied with distance from pores consistently with anticipated O 2 diffusion, while in the soil from restored prairie, the spatial patterns suggested that biological activity played a greater role in influencing Mn distributions. Based on the findings, we propose a hypothesis that Mn transformations promote C gains in soils of high plant diversity grasslands.

54 ENVIRONMENTAL SCIENCES↗

Visualizing Electric and Magnetic Field Coupling in Au-Nanorod Trimer Structures via Stimulated Electron Energy Gain and Cathodoluminescence Spectroscopy: Implications for Meta-Atom Imaging

In this work, trimer meta-atoms composed of three gold rods in an equilateral triangular geometry were fabricated, and their near-field plasmonic responses were characterized via electron energy loss (EEL), cathodoluminescence (CL), and stimulated electron energy loss/gain (sEEL/sEEG) spectroscopy. The trimer structure hybridizes into a low-energy mode with all three rods coupling in-phase, which produces a circulating current and thus a magnetic field. The next highest-energy mode consists of two rods coupling out-of-phase and produces a net electric dipole. We investigate the near fields of hybridized magnetic and electric modes via EEL and CL and correlate their spectral characteristics and intensity maps. Then, by changing the length of the trimer rods, we tune the magnetic and electric modes to our laser energy and characterize the excited state via sEEL/sEEG spectroscopy. Exploration of the tilt dependence, relative to the optical source, of the two modes reveals that the electric mode sEEG intensity increases more than the expected sin 2 (θ) dependence of the optical electric field coupling (see the Supporting Information for a detailed description). After correcting for the tail of the close-proximity electric mode, we demonstrate sEEG via coupling of the magnetic component of the optical field to the magnetic meta-atoms, which has the expected cos 2 (θ) tilt dependence. This realization opens the possibility to explore the nanoscale excited-state near-field imaging of other magnetic meta-atom structures.

36 MATERIALS SCIENCE↗

Nanoindentation-Enhanced Tip-Enhanced Raman Spectroscopy

We combine nanoindentation, herein achieved using atomic force microscopy (AFM)-based pulsed-force lithography, with tip-enhanced Raman spectroscopy (TERS) and imaging. Our approach entails indentation and multimodal characterization of otherwise flat Au substrates, followed by chemical functionalization and TERS spectral imaging of the indented nanostructures. We find that the resulting structures, which vary in shape and size depending on the tip used to produce them, may sustain nano-confined and significantly enhanced local fields. We take advantage of the latter and illustrate TERS-based ultrasensitive detection/chemical fingerprinting as well as chemical reaction imaging – all using a single platform for nano-lithography, topographic imaging, hyperspectral dark field optical microscopy, and TERS.

Wang, Chih-Feng↗

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U↗

Nanoscale Surface Structure of Nanometer-Thick Ferroelectric BaTiO 3 Films Revealed by Synchrotron X-ray Scanning Tunneling Microscopy: Implications for Catalytic Adsorption Reactions

Ferroelectric nanomaterials are of interest in catalysis, non-volatile memory, and neuromorphic computing among other applications because of their switchable structure that can alter electronic and interface properties of a single material. The investigation of the role of polarization on the surface structure and chemistry of ferroelectric nanomaterials is a longstanding challenge, as it ideally requires a combination of both nanoscale imaging and chemical spectroscopy. In this work we study a model ferroelectric BaTiO 3 thin film by synchrotron X-ray scanning tunneling microscopy (SX-STM), a unique method which integrates nanoscale surface imaging and chemically sensitive spectroscopy. We find that polarization switching from downward to upward in (001)single crystalline BaTiO 3 thin films increases the intensity of X-ray absorption across Ba M, Ti L and O K edges. Chemical mapping of nanometer sized domains further demonstrates the modulation of surface structures upon polarization switching, as well as confirming the trends observed in single point experiments across the surface. Here, we complement these measurements with ab-initio computational absorption spectroscopy to elucidate the effect of polarization switching on the core-hole excitations using the Bethe-Salpeter equation approach. Our experimental and theoretical results thus confirm a stronger binding strength for the upward polarized surface with molecular O 2 as a model reactant, offering mechanistic evidence that supports previous reports. This work advances the understanding of the surface chemistry and electronic structure of ferroelectrics, which can ultimately aid strategies to design interfaces with tailored properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Calibration and Validation of the SHERLOC Instrument Operating in Jezero Crater, Mars

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemistry (SHERLOC) is an instrument onboard the Mars 2020 Perseverance rover. It consists of a spectrometer that measures deep ultraviolet (DUV) resonance Raman and native fluorescence photons generated through surface interactions with a 248.6 nm pulsed laser. Two microscopic imagers, the Autofocus Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering (WATSON), provide high-resolution context images of SHERLOC targets. The ACI is co-boresighted with the spectrometer. To ensure proper calibration, the SHERLOC calibration target (SCT) is mounted on the front of the rover and consists of ten different materials. The SCT was designed, fabricated, assembled, and tested by Jacobs Technology, Inc., and NASA Johnson Space Center. The dimensions of the calibration target housing are 150 x 89 x 33 mm and it weighs ~437 g. The ten targets are arranged in two rows; the first six are hard targets (AlGaN for Raman and fluorescence, diffuse transmission target, a slice of the SaU008 Mars meteorite, an intensity maze, and polycarbonate over geocache coin) and the remaining four are soft-goods targets (Vectran, Ortho-Fabric, Teflon, and nGimat-coated Teflon). The hard targets calibrate the spectrometer’s Raman and fluorescence spectral accuracy, ambient light reflection, and Raman response curve, while the soft-goods targets are spacesuit materials that function as human exploration targets, some of which are also used for spectral calibration. SHERLOC also has an internal calibration target consisting of AlGaN on sapphire (275 nm) located inside the ACI opaque dust cover to ensure proper instrument functioning between calibration target analyses. Initial SHERLOC, ACI, and WATSON calibration and validation on Mars was performed using the internal calibration target on sols 59, 83, 98, and 141; WATSON imaging of the SCT on sols 26 and 62, and SHERLOC spectroscopy and ACI imaging of the SCT on sol 59. These early data provide initial insights into instrument performance and the stability and degradation of the calibration target materials relative to the Martian surface and dust environment. Early observations also have implications for future astronaut spacesuit materials.

Trevor G Graff↗

Cooperative Testing of Rocket Injectors That Use Gaseous Oxygen and Hydrogen

Gaseous oxygen and hydrogen propellants used in a special engine energy cycle called Full-Flow Staged Combustion are believed to significantly increase the lifetime of a rocket engine's pumps. The cycle can also reduce the operating temperatures of the engine. Improving the lifetime of the hardware reduces its overall maintenance and operations costs, and is critical to reducing costs for the joint NASA/industry Reusable Launch Vehicle (RLV). The work in this project will demonstrate the performance and lifetime of one-element and many-element combustors with gaseous O2/H2 injectors. This work supporting the RLV program is a cooperative venture of the NASA Lewis Research Center, the NASA Marshall Space Flight Center, Rocketdyne, and the Pennsylvania State University. Information about gas-gas rocket injector performance with O2/H2 is very limited. Because of this paucity of data, new testing is needed to improve the knowledge base for testing and designing new injectors for the RLV and to improve computer models that predict the combusting gas flows of new injector designs. Therefore, detailed observations and measurements of the combusting flow from many-element injectors in a rocket engine are being sought. These observations and measurements will be done with three different tools: schlieren photography, ultraviolet imaging, and Raman spectroscopy. The schlieren system will take photos of the density differences in combusting flow, the ultraviolet movies will determine the location of the hydroxyl (OH) radical in the combustion flow, and the Raman spectroscopic measurements will provide the combustion temperature and amount of water (H2O), hydrogen (H2), and oxygen (O2) in the combustor. Marshall is providing overall program management, design and computational fluid dynamics (CFD) analyses, as well as funding for the work at Penn State. An existing, windowed combustor and several injectors will be provided by Rocketdyne--two injectors for the initial screening tests and one with an optimized design based on the best design found in the screening tests. Lewis will provide a nozzle and several injectors for the screening test program. The configuration of the injectors will be based on a design chosen by all the participants, and their elements will be based on the coaxial and impinging flow. Lewis also will provide the instrumentation for the flow-field measurements: schlieren, ultraviolet imaging, and Raman spectroscopy. In addition, thermocouples will measure heat flow on the injector face. Other traditional measurements of rocket performance will be made as well: chamber pressure, mass flow of each propellant, purge flow, and the barrier cooling gas flow. Penn State will conduct single-element testing with the injector elements from both the Rocketdyne and the jointly designed injectors. A wide variety of traditional and nontraditional injector designs will be tested in this program. The results will be valuable in computational fluid dynamics code validation and overall rocket combustion efficiency measurements. Correlations between combustion efficiency, laser measurements of species, and ultraviolet and visible light photography will also be made. Thus far, several different single-element injectors have been tested at Penn State and Lewis. The experimental setup of a rocket engine with a viewing window is shown. The combusting flow is shown. The results are helping engineers design the many element injectors.

Source record↗

Probing the Formation of Cathode-Electrolyte Interphase on Lithium Iron Phosphate Cathodes via Operando Mechanical Measurements

Interfacial instabilities in electrodes control the performance and lifetime of Li-ion batteries. While the formation of solid-electrolyte interface (SEI) on anodes has received much attention, there is still lack of understanding about the formation of cathode-electrolyte interface (CEI) on the cathodes. To fill this gap, we report on dynamic deformations on lithium iron phosphate, LiFePO 4 cathodes during charge / discharge by utilizing in-operando digital image correlation, impedance spectroscopy and Cryo X-ray photoelectron spectroscopy. LiFePO4 cathodes were cycled in either LiPF 6 , LiClO 4 or LiTFSI- containing organic liquid electrolytes. Beyond the first cycle, Li-ion intercalation results in a nearly linear correlation between electrochemical strains and the state of (dis)-charge, regardless of the electrolyte chemistry. However, during the first charge in LiPF 6 - containing electrolyte, there is a distinct irreversible positive strain evolution at the onset of anodic current rise as well as current decay at around 4.0V. Impedance studies show the increase in surface resistance in the same potential window, suggesting the formation of CEI layers on the cathode. The chemistry of the CEI layer was characterized by X-ray photoelectron spectroscopy. LiF is detected in CEI layer starting as early as 3.4 V and Li $x$ PO $y$ F $z$ appeared at voltages higher than 4.0 V during the first charge. In conclusion, our approach offers new insights into the formation mechanism of CEI layers on the cathode electrodes, which is crucial for the development of robust cathode and electrolyte chemistries for higher performance batteries.

25 ENERGY STORAGE↗