Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Understanding the Feasibility of MAB Phase Structures for Lunar Applications

During the ten-week internship, my work focused on synthesis, characterization, and tailoring the flowability of the MAB phase powders for improving the surface finish and decreasing porosity of 3D-printed MAB phase structures. My mentor for the project was Dr. Samuel Hocker from NASA Langley and my faculty advisor was Dr. Surojit Gupta from the University of North Dakota. I also collaborated with Daniel Trieff from the University of North Dakota in developing characterization paradigm of 3D printed samples. The microencapsulation was performed via novel solvent casting-based microencapsulation process pioneered in UND, wherein a polymer (PLA, PHA) was dissolved into dichloromethane and precipitated onto the surface of the MoAlB particles. Two 100mL samples of microencapsulated powder was outsourced to Particle Technology Labs for flowability testing along with a 100mL control sample to determine if microencapsulation is a valid method for improving the flowability. The microencapsulated powders were characterized using SEM, Differential Scanning Calorimetry, and optical microscopy. The SEM images showed no change between the pure and microencapsulated powders. The optical microscopy analysis indicated a reduction in reflectivity for the PLA microencapsulated powders as well as hydrophobic properties. Both results suggest that microencapsulation was successful as PLA is a hydrophobic polymer and the change in reflectivity could be a result of the light being dispersed through the polymer coating. A reflectivity analysis will be done to bring more perspective to these observations. If powder flowability is improved, then the project will move forward with testing the printability of the microencapsulated powders and characterizing the structures using the designed characterization protocol. We are waiting for the DSC results. The characterization protocol for the 3D-printed MAB structures included a visual inspection of the plates to rule out any samples that had spalled or delaminated, optical microscopy to document surface features, porosity, and decomposition, and cleaning of the plates using an ultrasonic bath in preparation for SEM, EDS, and profilometry analyses.

MAB Phase↗

80-GHz MMIC HEMT Voltage-Controlled Oscillator

A voltage-controlled oscillator (VCO) that operates in the frequency range from 77.5 to 83.5 GHz has been constructed in the form of a monolithic microwave integrated circuit (MMIC) that includes high-electron-mobility transistors (HEMTs). This circuit is a prototype of electronically tunable signal sources in the 75-to-110-GHz range, needed for communication, imaging, and automotive radar applications, among others. This oscillator (see Figure 1) includes two AlInAs/GaInAs/InP HEMTs. One HEMT serves mainly as an oscillator gain element. The other HEMT serves mainly as a varactor for controlling the frequency: the frequency-control element is its gate-to-source capacitance, which is varied by changing its gate supply voltage. The gain HEMT is biased for class-A operation (meaning that current is conducted throughout the oscillation cycle). Grounded coplanar waveguides are used as impedance-matching transmission lines, the input and output matching being chosen to sustain oscillation and maximize output power. Air bridges are placed at discontinuities to suppress undesired slot electromagnetic modes. A high density of vias is necessary for suppressing a parallel-plate electromagnetic mode that is undesired because it can propagate energy into the MMIC substrate. Previous attempts at constructing HEMT-based oscillators yielded circuits with relatively low levels of output power and narrow tuning ranges. For example, one HEMT VCO reported in the literature had an output power of 7 dBm (.5 mW) and a tuning range 2-GHz wide centered approximately at a nominal frequency of 77 GHz. In contrast, as shown in Figure 2, the present MMIC HEMT VCO puts out a power of 12.5 dBm (.18 mW) or more over the 6-GHz-wide frequency range from 77.5 to 83.5 GHz

Samoska, Lorene↗

Near Infrared In-situ Measurements for the Detection of Keyhole Porosity in Autogenous Ti-6AL-4V Welds

Certification of additive manufactured metal parts requires nondestructive evaluation (NDE) to ensure build quality. NDE can be performed during the build process or post build. For large parts with complex geometries, post build NDE can be challenging. In-situ NDE potentially provides a way to perform the inspection layer by layer. This work explores the use of a high speed near infrared (NIR) camera that is focused in-line with a laser to obtain high spatial and temporal resolution thermal imagery of the melt pool and associated cooling areas. The thermal data is obtained during a laser melting process using Ti-6AL-4V plate and of particular interest is the detection of keyhole porosity. Keyhole porosity can result from non-optimal build conditions, such as excessive laser power at a given laser scanning speed, that creates an entrapped bubble. The NIR measured melt pool and cooling areas are processed to detect keyhole porosity. The results are compared to X-ray CT results for validation.

additive manufacturing↗

(U) Endpoint Energy and Scintillator Geometry Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy Radiography

High-energy radiography is used to image imploding materials to better understand weapon design and performance. The Enhanced Capabilities for Subcritical Experiments (ECSE) is a new facility proposal that aims to collect radiographic images of nuclear material. As part of the facility design, we aim to optimize data quality and radiographic performance by investigating different detector designs. We addressed design decisions by simulating different scintillator designs using M CNP6 and calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(O)). First, we investigated the effects of the x-ray endpoint energy on the detector response. We generated three x-ray spectra with endpoint energies of 20 MeV, 22 MeV, and 24 MeV. The three raw spectra were filtered using the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) line-of-sight materials along with 1) flat field filtration using 7 cm tungsten alloy in the bullnose and 2) an FTO with 4 plates. The scatter-to-direct radiation ratio was much larger for FTO with 4 plates (50-60%) compared to the flat field with 7 cm of bullnose material (8%). We used these filtered spectra to calculate the detector response for the original DARHT segmented scintillator design. We found that the endpoint energy and filtration had a negligible effect on the detector response. The quantum efficiency was 0.63, the Swank factor was 0.84, and the DQE(O) was 0.53 for all six spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3-D Surface Depression Profiling Using High Frequency Focused Air-Coupled Ultrasonic Pulses

Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. This article shows quantitative surface topography profiles as obtained using only high-frequency focused air-coupled ultrasonic pulses. The profiles were obtained using a profiling system developed by NASA Glenn Research Center and Sonix, Inc (via a formal cooperative agreement). (The air transducers are available as off-the-shelf items from several companies.) The method is simple and reproducible because it relies mainly on knowledge and constancy of the sound velocity through the air. The air transducer is scanned across the surface and sends pulses to the sample surface where they are reflected back from the surface along the same path as the incident wave. Time-of-flight images of the sample surface are acquired and converted to depth/surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in air (V). The system has the ability to resolve surface depression variations as small as 25 microns, is useable over a 1.4 mm vertical depth range, and can profile large areas only limited by the scan limits of the particular ultrasonic system. (Best-case depth resolution is 0.25 microns which may be achievable with improved isolation from vibration and air currents.) The method using an optimized configuration is reasonably rapid and has all quantitative analysis facilities on-line including 2-D and 3-D visualization capability, extreme value filtering (for faulty data), and leveling capability. Air-coupled surface profilometry is applicable to plate-like and curved samples. In this article, results are shown for several proof-of-concept samples, plastic samples burned in microgravity on the STS-54 space shuttle mission, and a partially-coated cylindrical ceramic composite sample. Impressive results were obtained for all samples when compared with diamond-tip profiles and measurements from micrometers. The method is completely nondestructive, noninvasive, non-contact and does not require light-reflective surfaces.

Roth, Don J.↗

Extensional Flow of a Polystyrene Boger Fluid Through a 4:1:4 Axisymmetric Contraction/Expansion

The creeping flow of a dilute (0.025 wt%) monodisperse polystyrene/polystyrene Boger fluid through a 4:1:4 axisymmetric contraction/expansion is experimentally observed for a wide range of Deborah numbers. Pressure drop measurements across the orifice plate show a large extra pressure drop that increases monotonically with Deborah number above the value observed for a similar Newtonian fluid at the same flow rate. This enhancement in the dimensionless pressure drop is not associated with the onset of a flow instability, yet it is not predicted by existing steady-state or transient numerical computations with simple dumbbell models. It is conjectured that this extra pressure drop is the result of an additional dissipative contribution to the polymeric stress arising from a stress-conformation hysteresis in the strong non-homogeneous extensional flow near the contraction plane. Such a hysteresis has been independently measured and computed in recent studies of homogeneous transient uniaxial stretching of PS/PS Boger fluids. Flow visualization and velocity field measurements using digital particle image velocimetry (DPIV) show large upstream growth of the corner vortex with increasing Deborah number. At large Deborah numbers, the onset of an elastic instability is observed, first locally as small amplitude fluctuations in the pressure measurements, and then globally as an azimuthal precessing of the upstream corner vortex accompanied by periodic oscillations in the pressure drop across the orifice.

Rothstein, Jonathan P.↗

Controlling matric potential in microfluidics to examine microbial dynamics in unsaturated porous media

The use of microfluidics for the study of soil microbial ecology is an emerging field. Most microfluidic studies of biological systems, however, have been performed under fully saturated conditions that are not representative of natural soil. Therefore, while microfluidics offer many unique capabilities that other methodologies cannot, they are not currently suited to address the effects of matric potential, an important variable defining the microbial moisture niche. Here, a methodology is presented that allows the user to control the aqueous conditions within microfluidic networks by manipulating matric potential using a hanging water column. The method relies on hydrophilic surface treatment of the microfluidic device using polyvinyl alcohol (PVA) and incorporating a bed of small pores at the network boundaries, which serve as a porous ceramic plate analogue (PPA). The method was validated on a simple capillary bundle and then on a more complex pore network. A water retention curve, exhibiting hysteresis, was generated for the pore network over a narrow matric potential range of 0 to – 5 kPa. Both the drainage and wetting curves were reproducible, as were the spatial configuration and the number of fragmented moisture niches in the pore network, particularly on the drainage curve. In contrast, the wetting curve exhibited greater variability in spatial configuration due to the “ink bottle effect,” where capillarity was interrupted by wider pore bodies. Ultimately, the methodology provides realistic pore-scale moisture conditions that can be easily manipulated and maintained, enabling new opportunities to explore soil biophysics and microbial biogeography in unsaturated porous media. As a brief example, images showing the localization of fluorescently tagged Pantoea sp. YR343 at −4.3 kPa are presented, highlighting bacterial distributions in water films and air-water interfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Seismotectonic evidence for subduction beneath the Eastern Greater Caucasus

SUMMARY We generated high-resolution 3-D seismic velocity models as well as a relocated earthquake catalogue across the eastern Greater Caucasus and Kura basins. This work was done using data from the recently upgraded Republic Seismological Survey Center's (RSSC) seismic network. We generated our tomographic images of crustal velocity structure in Azerbaijan using double-difference inversions (i.e. tomoDD and hypoDD). Earthquake catalogues from the RSSC between 2011 and 2016 were used; these catalogues include absolute arrival times of 103 288 P- and 120 952 S-wave traveltime picks for 7574 events recorded at 35 stations in Azerbaijan. Beginning with a layered, 1-D velocity model that was estimated using VELEST, we inverted simultaneously for relative location, Vp and Vs on a 3-D grid with dimensions 670 × 445 × 45 km, with a uniform grid spacing of 55 × 55 × 5 km for all of Azerbaijan. We observe that the relocated hypocentres cluster into two depth ranges, at the surface and at depth, that appear to correspond to major fault zones and the top of a subducting plate. Additionally, we note intermediate depth seismicity (∼50–60 km) beneath the Kura Basin, and a northward deepening of earthquake depths. Seismic velocities vary significantly throughout the study region; we observe very slow velocities throughout the Kura Basin between 5 and 15 km, and elevated velocities at 20–35 km. The wholesale velocity structure and seismic structure of Kura Basin strongly mirrors that of the Caspian Sea, which suggests that the geodynamics of the Caspian continue westwards into Azerbaijan. The key results of this study suggest that the northward subduction observed in the Caspian Sea continues beneath the Eastern Greater Caucasus, as well as provides evidence for active faulting along the southern margin of the mountain range.

Gunnels, Michael↗

Microstructural characterization of as-fabricated monolithic plates with boron carbide, aluminum boride, and zirconium boride burnable absorbers

The use of burnable absorbers can be beneficial for nuclear reactors by extending the fuel’s operational cycle, providing additional criticality control, and flattening the power profile. In this work, three burnable absorber materials (boron carbide, aluminum boride, and zirconium boride) embedded in aluminum have been fabricated into foils and clad in AA-6061 for potential use in high performance research reactors. The as-fabricated boron-containing phases were determined using transmission electron microscopy to be AlB2, B4C, and ZrB2. TEM also revealed weak bonding at the B4C-matrix interface. SEM showed a relatively uniform spatial distribution of boron-containing phases for all the candidate materials. Higher porosity was observed in the foil containing ZrB2 in its as-rolled condition. The porosity in the ZrB2 foil was reduced by hot isostatic pressing. The size and shape distributions of the boron-containing phases were analyzed on the criteria of cross-sectional area, perimeter, roundness, circularity, and aspect ratio. A method of converting the 2D burnable absorber dispersoids seen in cross-sectional microscopy images into 3D volumes was derived using both spherical and ellipsoidal geometry models. The difference in calculated burnable absorber dispersoid average volume between the two models ranges from 20% to 100%, which could impact burnable absorber burnout rates due to differences in neutron self-shielding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Terahertz Chiral Metamaterials Enabling Broadband Polarization Conversion Using Polarization Guiding Effect

Polarization control plays a vital role in terahertz (THz) photonics, enabling a wide range of applications from imaging and spectroscopy to sensing and wireless communication. However, conventional polarization control methods at THz frequencies are limited by narrow operational bandwidths and excessive absorption losses. In this work, we present a broadband THz polarization control based on the polarization guiding effect. We design and fabricate a THz polarization rotator capable of rotating incident linear polarization by 90°. The device consists of 24 twistingly stacked silicon–air metagrating layers that introduce a large degree of form birefringence, with each metagrating layer being 280 µm thick and sequentially twisted by 3.75°. Numerical simulations using the Berreman 4 × 4 method predict broadband operation of the device. Experimental validation using THz time-domain spectroscopy confirms efficient and broadband 90° polarization rotation from 0.2 to 1.25 THz. Based on this concept, we further propose THz Q-plates for the generation of broadband structured vector beams with radial and azimuthal polarization states. This work offers a scalable, material-agnostic platform for advanced THz polarization manipulation and vector beam engineering, opening new pathways for next-generation THz photonic devices.

36 MATERIALS SCIENCE↗

Compositional Analysis of Martian Soil: Synergism of APEX and MECA Experiments on MPS 2001

The APEX (ATHENA Precursor Experiment) payload for the Mars 2001 mission will analyze soil and dust with a multispectral panoramic imager and an emission spectrometer on a mast on the lander, a Moessbauer spectrometer on the lander robotic arm (RA), and APXS measurements on the Marie Curie rover. These analytical methods will provide data on elemental abundances and mineralogy. The MECA payload on the lander will apply microscopy, AFM, wet chemistry, adhesive substrates, and electrometry to determine the shape and size of particles in the soil and dust, the presence of toxic substances, and electrostatic, magnetic, and hardness qualities of particles. The two experiments will complement one another through several interactions: (1) The panoramic imager provides the geological setting in which both APEX and MECA samples are acquired, (2) The RA provides samples to MECA from the surface and subsurface and will permit APEX analytical tools access to materials below the inunediate surface, (3) Comparisons can be made between elemental analyses of the Moessbauer, IR, APXS on APEX and the wet chemistry of MECA which will define trace elements (ionic species in solution) and soil redox potential and conductivity. (4) APEX bulk compositional measurements will place MECA trace measurements in context, and similarly, MECA microscopy will provide particle size data that may correlate with compositional differences determined by the APEX instruments. Additionally, lithic fragments viewed by the NMCA microscope station should correlate with mineral/rock species inferred by APEX data, (5) If APEX instruments detect quartz for example, the scratch plates of the N4ECA microscope stage will define if a mineral of this hardness is registered during abrasion tests. This is by no means an exhaustive list of potential interactions, but it is clear that both the sheer number of analytical techniques and their complementarity should provide an analytically powerful capability for both planetary and BEDS communities.

Arvidson, R.↗

Compositional Analysis of Martian Soil: Synergism of APEX and MECA Experiments on MPS 2001

The APEX (ATHENA Precursor Experiment) payload for the Mars 2001 mission will analyze soil and dust with a multispectral panoramic imager and an emission spectrometer on a mast on the lander, a Moessbauer spectrometer on the lander robotic arm (RA), and APXS measurements on the Marie Curie rover. These analytical methods will provide data on elemental abundances and mineralogy. The MECA payload on the lander will apply microscopy, AFM, wet chemistry, adhesive substrates, and electrometry to determine the shape and size of particles in the soil and dust, the presence of toxic substances, and electrostatic, magnetic, and hardness qualities of particles. The two experiments will complement one another through several interactions: (1) The panoramic imager provides the geological setting in which both APEX and MECA samples are acquired, (2) The RA provides samples to MECA from the surface and subsurface and will permit APEX analytical tools access to materials below the immediate surface, (3) Comparisons can be made between elemental analyses of the Moessbauer, IR, APXS on APEX and the wet chemistry of MECA which will define trace elements (ionic species in solution) and soil redox potential and conductivity. (4) APEX bulk compositional measurements will place MECA trace measurements in context, and similarly, MECA microscopy will provide particle size data that may correlate with compositional differences determined by the APEX instruments. Additionally, lithic fragments viewed by the MECA microscope station should correlate with mineral/rock species inferred by APEX data, (5) If APEX instruments detect quartz for example, the scratch plates of the MECA microscope stage will define if a mineral of this hardness is registered during abrasion tests. This is by no means an exhaustive list of potential interactions, but it is clear that both the sheer number of analytical techniques and their complementarity should provide an analytically powerful capability for both planetary and HEDS communities.

Arvidson, R.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

AXAF VETA-I mirror ring focus measurements

The AXAF VETA-I mirror ring focus measurements were made with an HRI (microchannel plate) X-ray detector. The ring focus is a sharply focused ring formed by X-rays before they reach the VEAT-I focal plane. It is caused by spherical aberrations due to the finite source distance and the despace in the VETA-I test. The ring focus test reveals some aspects fo the test system distortions and the mirror surface figure which are difficult or impossible to detect at the focal plane. The test results show periodic modulations of the ring radius and width which could be caused by gravity, thermal, and/or epoxy shrinkage distortions. The strongest component of the modulation had a 12-fold symmetry, because these distortions were exerted on the mirror through 12 flexures of the VETA-I mount. Ring focus models were developed to simulate the ring image. The models were compared with the data to understand the test system distortions and the mirror glass imperfection. Further studies will be done to complete this work. The ring focus measurement is a very powerful test. We expect that a similar test for the finally assembled mirror of AXAD-I will be highly valuable.

Tananbaum, H. D.↗

Seismic Tomographic Modeling of the Crust and Upper Mantle beneath Israel and the Middle East: Improved Resolution through Optimized Model Parameterization

Accurate regional seismic travel-time (RSTT) predictions rely on regional phases (e.g., Pg, Lg, Pn, Sn ) to account for 3D effects in the crust and upper mantle that are not captured by 1D models traditionally used for real-time location. The RSTT prediction model accounts for regional-scale crust and upper mantle structure globally by incorporating regional seismic phases into its travel-time calculations. Previous versions of the RSTT model have used a constant grid cell size of 1°. To improve the tomographic accuracy of recovering velocity structure at regional scales, we, in this study, perform data-driven grid refinement on the RSTT model down to a 0.125° grid (~14 km) in pursuit of two main goals: (1) to test the limits of RSTT capability and accuracy of determined velocity structure through variable grid refinement and (2) to image smaller structures in Israel and the Middle East and illuminate upper mantle dynamics operating in this complex tectonic area. We investigate the effects of model parameterization as grid cell size decreases and the trade-offs between recovered velocity structures. Our final dataset includes 4751 events and 499 stations that recorded 79,344 Pn and 7489 Pg . The variable grid refinement method allows recovery of finer-scale velocity structures and reduces travel-time residuals in areas with the highest data coverage. At smaller grid cell sizes, longer paths need to be upweighted to stabilize the inversion. Results illuminate tectonic features undefined in coarser grid-size models; in particular, we observe mantle perturbations related to the subduction zone around the Cyprian arc and crustal anomalies near the Dead Sea fault and throughout the Anatolian plate.

58 GEOSCIENCES↗

High resolution decoding of Multi-Anode Microchannel Array detectors

The Multi-Anode Microchannel Array (MAMA) is a photon counting detector which utilizes a photocathode for photon to electron conversion, a microchannel plate (MCP) for signal amplification and a proximity focused anode array for position sensitivity. The detector electronics decode the position of an event through coincidence discrimination. The decoding algorithm which associates a given event with the appropriate pixel is determined by the geometry of the array. A new algorithm incorporated into a CMOS Application Specific Integrated Circuit (ASIC) decoder which improves the pixel spatial resolution is described. The new algorithm does not degrade the detector throughput and does not require any modifications to the detector tube. The standard MAMA detector has a pixel size of 25 x 25 square microns, but with the new decoder circuit the pixel size is reduced to 12.5 x 12.5 square microns. We have built the first set of decode electronics utilizing the new ASIC chips and report here on the first imaging tests of this system.

Kasle, David B.↗

LDEF post-retrieval evaluation of exobiology interests

Cursory examination of the Long Duration Exposure Facility (LDEF) shows the existence of thousands of impact craters of which less than 1/3 exceed 0.3 mm in diameter; the largest crater is 5.5 mm. Few craters show oblique impact morphology and, surprisingly, only a low number of craters have recognizable impact debris. Study of this debris could be of interest to exobiology in terms of C content and carbonaceous materials. All craters greater that 0.3 mm have been imaged and recorded into a data base by the preliminary examination team. Various portions of the LDEF surfaces are contaminated by outgassed materials from experimenters trays, in addition to the LDEF autocontamination and impact with orbital debris not of extraterrestrial origin. Because interplanetary dust particles (IDP's) nominally impacted the LDEF at velocities greater than 3 km/s, the potential for intact survival of carbonaceous compounds is mostly unknown for hypervelocity impacts. Calculations show that for solid phthalic acid (a test impactor), molecular dissociation would not necessarily occur below 3 km/s, if all of the impact energy was directed at breaking molecular bonds, which is not the case. Hypervelocity impact experiments (LDEF analogs) were performed using the Ames Vertical Gun Facility. Grains of phthalic acid and the Murchison meteorite (grain diameter = 0.2 for both) were fired into an Al plate at 2.1 and 4.1 km/s respectively. The results of the study are presented, and it is concluded that meaningful biogenic elemental and compound information can be obtained from IDP impacts on the LDEF.

Bunch, T. E.↗

PHyTIR - A Prototype Thermal Infrared Radiometer

This paper describes the PHyTIR (Prototype HyspIRI Thermal Infrared Radiometer) instrument, which is the engineering model for the proposed HyspIRI (Hyperspectral Infrared Imager) earth observing instrument. The HyspIRI mission would be comprised of the HyspIRI TIR (Thermal Infrared Imager), and a VSWIR (Visible Short-Wave Infra-Red Imaging Spectrometer). Both instruments would be used to address key science questions related to the earth's carbon cycle, ecosystems, climate, and solid earth properties. Data gathering of volcanic activities, earthquakes, wildfires, water use and availability, urbanization, and land surface compositions and changes, would aid the predictions and evaluations of such events and the impact they create. Even though the proposed technology for the HyspIRI imager is mature, the PHyTIR prototype is needed to advance the technology levels for several of the instrument's key components, and to reduce risks, in particular to validate 1) the higher sensitivity, spatial resolution, and higher throughput required for this focal plane array, 2) the pointing accuracy, 2) the characteristics of several spectral channels, and 4) the use of ambient temperature optics. The PHyTIR telescope consists of the focal plane assembly that is housed within a cold housing located inside a vacuum enclosure; all mounted to a bulkhead, and an optical train that consists of 3 powered mirrors; extending to both sides of the bulkhead. A yoke connects the telescope to a scan mirror. The rotating mirror enables to scan- a large track on the ground. This structure is supported by kinematic mounts, linking the telescope assembly to a base plate that would also become the spacecraft interface for HyspIRI. The focal plane's cooling units are also mounted to the base plate, as is an overall enclosure that has two viewing ports with large exterior baffles, shielding the focal plane from incoming stray light. PHyTIR's electronics is distributed inside and near the vacuum enclosure, and in a nearby rack. The data acquisition technique would be to take measurements over a 51deg wide swath in the cross spacecraft velocity direction, which is brought into view through the rotating scan mirror. A landscape mosaic thus can be assembled by overlaying rows of measurements. The paper briefly outlines the proposed HyspIRI mission and its data acquisition technique; it then describes the prototype PHyTIR instrument.

Space Instrument↗