Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HYDROGEN STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Crowd-Sourced Technology Challenge for Improving Visual Color Detection of Hydrazine and Monomethylhydrazine Vapors in Spacecraft Environments

NASA currently uses a visual colorimetric detection method for potential hydrazine, monomethylhydrazine (MMH), or unsymmetrical dimethylhydrazine (UDMH) contamination in the International Space Station. Astronauts exposed to propellants or their residues during extravehicular activities may transfer contaminants into the airlock. The colorimetric detection method employs the Contamination Detection Kit (CDK), which uses a potassium tetrachloroaurate redox reaction with the propellant hydrazine vapors and a color comparison card to determine airborne concentrations. Seeking ideas for improvement, the NASA Tournament Lab (NTL) crowdsourced a way to tackle the challenge of detecting hydrazine and MMH vapors using colorimetric detection methods. This Rid the Rocket competition drew over 200 participants and 20 submissions from around the world proposing innovative ways to develop a new chemical colorimetric detection method for hydrazine and MMH vapors on spacecraft. Using a phased approach to evaluate contestants, NASA eventually narrowed the field to five finalists from the United States, Romania, Taiwan, and India. Concept papers and hardware submissions were judged on feasibility, creativity, and ability to detect hydrazine and MMH vapors before being sent to the NASA White Sands Test Facility for laboratory evaluation. Finalists employed variations of sampling methods and color-detection chemistry using a variety of sampling pumps and indicator pads or solutions—including those employing potassium or hydrogen tetrachloroaurate, para -dimethylaminobenzaldehyde (PDAB), and modifiers including sodium metasilicate and cetyltrimethylammonium bromide—to enhance gold nanoparticle formation and surface plasmon resonance (SPR) resulting in visual blue to purple color development. This paper presents a summary of the crowdsourced submissions and results of laboratory testing.

Crowd-Sourced↗

Cryogenic techniques for large superconducting magnets in space

A large superconducting magnet is proposed for use in a particle astrophysics experiment, ASTROMAG, which is to be mounted on the United States Space Station. This experiment will have a two-coil superconducting magnet with coils which are 1.3 to 1.7 meters in diameter. The two-coil magnet will have zero net magnetic dipole moment. The field 15 meters from the magnet will approach earth's field in low earth orbit. The issue of high Tc superconductor will be discussed in the paper. The reasons for using conventional niobium-titanium superconductor cooled with superfluid helium will be presented. Since the purpose of the magnet is to do particle astrophysics, the superconducting coils must be located close to the charged particle detectors. The trade off between the particle physics possible and the cryogenic insulation around the coils is discussed. As a result, the ASTROMAG magnet coils will be operated outside of the superfluid helium storage tank. The fountain effect pumping system which will be used to cool the coil is described in the report. Two methods for extending the operating life of the superfluid helium dewar are discussed. These include: operation with a third shield cooled to 90 K with a sterling cycle cryocooler, and a hybrid cryogenic system where there are three hydrogen-cooled shields and cryostat support heat intercept points.

Green, M. A.↗

Optimized shielding for space radiation protection

Future deep space mission and International Space Station exposures will be dominated by the high-charge and -energy (HZE) ions of the Galactic Cosmic Rays (GCR). A few mammalian systems have been extensively tested over a broad range of ion types and energies. For example, C3H10T1/2 cells, V79 cells, and Harderian gland tumors have been described by various track-structure dependent response models. The attenuation of GCR induced biological effects depends strongly on the biological endpoint, response model used, and material composition. Optimization of space shielding is then driven by the nature of the response model and the transmission characteristics of the given material.

NASA Discipline Radiation Health↗

Generation of radioisotopes for medical applications using high-repetition, high-intensity lasers

We used the PW high-repetition laser facility VEGA-3 at Centro de Láseres Pulsados in Salamanca, with the goal of studying the generation of radioisotopes using laser-driven proton beams. Various types of targets have been irradiated, including in particular several targets containing boron to generate α-particles through the hydrogen–boron fusion reaction. We have successfully identified γ-ray lines from several radioisotopes created by irradiation using laser-generated α-particles or protons including 43 Sc, 44 Sc, 48 Sc, 7 Be, 11 C and 18 F. We show that radioisotope generation can be used as a diagnostic tool to evaluate α-particle generation in laser-driven proton–boron fusion experiments. We also show the production of 11 C radioisotopes, ≈ 6 × 10 6 , and of 44 Sc radioisotopes, ≈ 5 × 10 4 per laser shot. This result can open the way to develop laser-driven radiation sources of radioisotopes for medical applications.

gamma ray spectroscopy↗

The MELCOR Analysis of Chinshan Nuclear Power Plant Spent Fuel Pool for Fukushima-like Accident

The safety analysis of the nuclear power plant (NPP) is very important work in the NPP safety. Especially after the Fukushima NPP accident occurred, the importance of NPP safety analysis has been raised and there is more concern for the safety of NPPs in Taiwan. Because the earthquake and tsunami occurred, the cooling system of spent fuel pool failed and the safety issue of spent fuel pool generated in Japan's Fukushima NPP. Chinshan NPP is the first NPP in Taiwan which is BWR/4 plant and OLTP (Original Licensed Thermal Power) for each unit is 1775 MWt. Chinshan NPP finished SPU (stretch power uprate) and the operating power is 103.66% of the OLTP, which is 1840 MWt now. After Fukushima NPP accident occurred, in order to concern the safety of Chinshan NPP spent fuel pool, we performed the safety analysis of spent fuel pool by using MELCOR/SNAP which also assumed the cooling system of spent fuel pool failed. The geometry of Chinshan NPP spent fuel pool is 12.17 m x 7.87 m x 11.61 m and the initial condition is 60 deg. (water temperature) / 1.013 x 10{sup 5} Pa. And, the total power of the fuels is roughly 8.9 MWt initially. MELCOR is developed by Sandia National Laboratories. MELCOR is a fully integrated, engineering-level computer code that models the progression of severe accidents in light water reactor NPPs, including containment response and leakage of activity to the environment. A broad spectrum of severe accident phenomena in both BWRs and PWRs is treated in MELCOR in a unified framework. These include thermalhydraulic response in the reactor coolant system, reactor cavity, containment, and confinement buildings; core heatup, degradation, and relocation; core-concrete attack; hydrogen production, transport, and combustion; fission product release and transport behavior. Current uses of MELCOR include estimation of severe accident source terms and their sensitivities and uncertainties in a variety of applications. According to Dr. Carbajo's paper, MELCOR was used to perform the study of spent fuel pool of Fukushima Daiichi Unit 4. Niina E. Koenoenen used MELCOR to establish the spent fuel pool model of a Nordic BWR. The loss-of-pool-cooling accidents was simulated and analyzed by this model. The above studies indicate that MELCOR is capable of handling the simulation of the spent fuel pool. An increasing number of researchers are using MELCOR code to analyze test facilities and nuclear power plants. Jun Wang et al. used MELCOR to perform core degradation simulation and MELCOR results were compared with CORA experimental data. Through this work, they reviewed the performance of MELCOR COR package in detail. Tae Woon Kim et al. developed MELCOR model of APR1400 (an advanced pressurized water reactor). They used this model to perform the LBLOCA transient simulation and sensitivity study. Longze Li et al. established the MELCOR model of CPR1000 (a Chinese pressurized reactor 1000-MW power plant). The station blackout (SBO) with failure of the steam generator (SG) safety relief valve (SRV) transient was simulated and analyzed by this model. SNAP is a graphic user interface program that processes the inputs and outputs of MELCOR. In addition, there is an animation function in SNAP which can present the animation of analysis results. There are two main steps in this research. The first step was the establishment of Chinshan NPP spent fuel pool MELCOR/SNAP model. And the transient analysis of Chinshan NPP spent fuel pool MELCOR/SNAP model under the cooling system failure condition was performed. The next step was the comparison among the MELCOR, TRACE and CFD data. TRACE and CFD data were from INER reports. In addition, the animation model of Chinshan NPP spent fuel pool was presented by using the animation function of SNAP with MELCOR/SNAP analysis results. This study has developed MELCOR/SNAP model of Chinshan NPP spent fuel pool successfully. By using the above model, the safety analysis of the spent fuel pool was performed under the cooling system of spent fuel pool failed condition. The analysis results of MELCOR, TRACE and CFD were similar in this case. It indicated that there was a respectable accuracy in MELCOR/SNAP model. The analysis results depicted that the uncovered of the fuels occurred at 2.6 day and the metal-water reaction of fuels occurred roughly at 3.7 day after the cooling system failed. The above results indicated that the failure of cladding occurred after 3.7 day. This study's results can help to evaluate the safety issue of Chinshan NPP spent fuel pool. In addition, the cooling system and some mitigation measures of spent fuel pool is not simulated in the above model. However, we will do it in the future. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Study on the Transfer of Cs, Sr, Pu and Water in Concrete for the Estimation of Contamination - 20085

As part of the 'Nuclear Energy Science and Technology and Human Resources Development project- through concentrating wisdom-by MEXT' in Japan, the major results from the second year of a project on the analysis of radionuclide contamination mechanisms of concrete and the estimation of contamination distribution at the Fukushima Daiichi nuclear power station active during 2018-2020 are presented. The transfer of Cs, Sr, Pu, and water through concrete was studied experimentally. In a saturated condition, the clay did not affect the transfer and Cs penetrated much faster than Sr. In the dried condition, clay retarded Cs transfer. Carbonation of the concrete retarded the transfer of Cs and Sr. Pu was expected to be precipitated immediately in a high pH condition of concrete. Water suction depends on the temperature. Further, the detailed mechanism was analyzed by {sup 1}H-NMR. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calibrating the Helium Pressurization System for the Space Shuttle Liquid-Hydrogen Tank

Analysis of the results from the STS-114 tanking tests and subsequent launch called into question existing thermal and mass models of helium pressurization of the liquid hydrogen tank. This hydrogen tank, which makes up the bottom two-thirds of the External Tank, is pressurized prior to launch to avoid cavitation in the Shuttle Main Engine pumps. At about 2 minutes prior to launch, the main vent valve is closed, and pressurized helium flows into the tank ullage space to achieve set point pressure. As the helium gas cools, its pressure drops, calling for additional helium. Subsequent helium flows are provided in short, timed pulses. The number of pulses is taken as a rough leak indicator. An analysis of thermal models by Marshall Space Flight Center showed considerable uncertainty in the pressure-versus-time behavior of the helium ullage space and the ability to predict the number of pulses normally expected. Kennedy Space Center proposed to calibrate the dime-sized orifice, which together with valves, controls the helium flow quantity (Figure 1). Pressure and temperature sensors were installed to provide upstream and downstream measurements necessary to compute flow rate based on the orifice discharge coefficient. An assessment of flow testing with helium indicated an extremely costly use of this critical resource. In order to reduce costs, we proposed removing the orifices from each Mobile Launcher Platform (MLP) and asking Colorado Engineering Experiment Station Inc. (CEESI) to calibrate the flow. CEESI has a high-pressure air flow system with traceable flow meters capable of handling the large flow rates. However, literature research indicated that square-edged orifices of small diameters often exhibit significant hysteresis and nonrepeatability in the vicinity of choked or sonic flow. Fortunately, the MLP orifices behaved relatively well in testing (Figure 2). Using curve fitting of the air-flow data, in conjunction with ASME orifice modeling equations, a method of relating the helium mass flow to measured air flow data was obtained. This analysis showed that the highest uncertainty in flow occurred in the vicinity of the choking pressure ratio, as would be expected. In addition, analysis of typical flow pulses showed that most of the helium flow occurred either well below or well above this uncertain area. The final result is the ability to provide postlaunch estimates of helium mass flows that are within 1.5 percent of the actual value.

Source record↗

Hydrogen-powered Electrochemically-driven CO 2 Removal from Air Containing 400 to 5000 ppm CO 2

The performance of a hydrogen-powered, electrochemically-driven CO 2 separator (EDCS) was demonstrated at cathode inlet CO 2 concentrations from 400 ppm to 5,000 ppm. The impact of current density and CO 2 concentration were evaluated to predict operating windows for various applications. The single-cell data was used to scale a 100 cm 2 , multi-cell stack using a shorted-membrane design for four applications: direct air capture (DAC), hydroxide exchange membrane fuel cell (HEMFC) air pretreatment, submarine life support, and space habitation. For DAC, a 339-cell EDCS stack (7.7 L, 17 kg) was projected to remove 1 tonne CO 2 per year. The addition of the EDCS in HEMFC systems would result in nearly a 30% increase in volume, and therefore further improvements in performance would be necessary. A module containing five 338-cell EDCS stacks (38 L, 85 kg) in parallel can support a 150 person crew at 2.1% of the volume of the liquid amine system employed in submarines. For space habitation, a 109-cell EDCS stack (3.2 L, 10 kg) is adequate for 6 crewmembers, and is less than 1% the size and 5% the weight of the current CO 2 removal system installed on the International Space Station.

25 ENERGY STORAGE↗

Optimization of the moderators in the STS preliminary design

This report details the results for an optimization of the dimensions of the moderators in the preliminary design of the Spallation Neutron Source Second Target Station (STS). This study uses the optimization algorithms of Dakota and an unstructured mesh model for the moderators in MCNP. More details on the unstructured mesh model and the automated mesh generation can be found in [3]. Parallel to this effort, the same moderator geometries have been optimized using a constructive solid geometry (CSG) MCNP model. More details on this model and its results can be found in [4]. Three optimal designs are selected for each moderator: one that is optimized for maximum peak brightness, one for maximum time-integrated brightness, and one for a combination of peak and time-integrated brightness. The backbone of the optimization work flow is provided by Dakota. For each set of design parameters requested by Dakota, a new solid geometry is automatically built in Creo and SpaceClaim, and subsequently exported to Attila4MC to generate an unstructured mesh geometry for MCNP. After the MCNP calculation is finished, the objective function (e.g., brightness metric) is returned to Dakota. After the new design has been evaluated, a result-file is written, and Dakota proposes the next set of design parameters to be evaluated. The loop continues until a specified convergence criterion has been met. The design parameters of the cylindrical (upper) moderator include the hydrogen radius, the premoderator thickness (top, bottom, radial), the beryllium radius and the horizontal position of the moderator. The crucial design choice is the hydrogen radius. A radius of 62 mm is shown to provide the maximum time-integrated brightness. The maximum peak brightness occurs with a radius of 40 mm. A combined (middle) design, which balances peak and time-integrated brightnesses, is obtained with a hydrogen radius of 50 mm. The premoderator thicknesses and the beryllium radius are slightly larger in the design optimized for time-integrated brightness than in the design optimized for peak brightness. The sensitivity to these two parameters is relatively small close to the optimal configurations. The hydrogen vessel and vacuum vessel wall thicknesses are dependent on the radius of the liquid hydrogen due to structural integrity requirements. The increased wall thicknesses for larger vessels significantly penalize the time-integrated brightness, with the maximum obtainable value reduced by more than 10% relative to earlier studies which used fixed vessel wall thicknesses. The impact of the variable wall thicknesses is much less for the peak brightness and combined brightness designs. The design parameters of the tube (lower) moderator selected for the optimization are the tube length, the annular premoderator thickness, the beryllium radius and the horizontal position of the moderator. The tube length is the crucial parameter and is chosen large (210 mm) and small (125 mm) in the designs optimized for time-integrated and peak brightness respectively. A combined optimal design has a tube length of 170 mm. The premoderator thickness and the beryllium radius are chosen larger in the design optimized for time-integrated brightness.

42 ENGINEERING↗

Anion-exchange membrane water electrolysis: insights from round-robin testing

As research and industrial interest in anion-exchange membrane water electrolysis (AEMWE) grows, there is an increasing need for reliable baselines and cross-lab validation of results. The wide variety of material sets and operating conditions under consideration for AEMWE has thus far limited efforts for standardization. In this study, round-robin testing was conducted in deionized water and KOH-based supporting electrolyte by 5 institutions from academia, national laboratories, and industry to provide baseline performance data and identify sources of cross-lab variability. Baseline membrane electrode assemblies were fabricated with commercial catalysts, membranes, and transport layers using standard techniques and tested using reagent-grade electrolytes, aiming for accessibility rather than state-of-the-art performance. From all tests, the average voltage at 1 A/cm 2 was 2.72 ± 0.17 V and 1.87 ± 0.03 V in deionized water and 0.1 M KOH, respectively. The maximum in-house and cross-lab variations at this current density were 118 mV and 476 mV in water and 60 and 88 mV in 0.1 M KOH. The KOH purity, station contamination, and temperature control were identified as possible factors affecting performance between labs, with in-house specific variation attributed to sample-to-sample differences in fabrication, cell assembly, and station contamination. This work provides a commercial baseline for the field and highlights the need for improved standardization and reproducibility in AEMWE research.

08 HYDROGEN↗

EMU evolution

Evolution of Extravehicular Mobility Unit (EMU) technology is necessary to support the Extravehicular Activity (EVA) requirements of the Space Station Freedom Program and those of the Space Exploration Initiative (SEI). Key qualities supporting long-duration missions include technologies that are highly reliable, durable, minimize logistics requirements, and are in-flight maintainable and serviceable. While these qualities are common to SSF and SEI EVA, development paths will differ where specific mission requirements impose different constraints. Development of reusable, regenerative technologies is necessary to minimize the logistics penalties. Increased battery discharge/recharge cycle life and usable wet life, compact high current density fuel cells, reusable CO2 absorbing media, and thermal radiation coupled with venting heat rejection technologies are just some methods of reducing consumables. Development must strive for durable, reliable systems that are in-flight serviceable and maintainable, which are vital for missions where logistics capabilities are extremely constrained. Key areas include suit components (e.g., gloves, boots, and cooling garments), and life support hardware such as fans, pumps, instrumentation, and emergency O2 systems. Higher pressure suits will reduce EVA prebreathe requirements and pre-EVA operations overall. Many challenges of higher pressure suits have been addressed by on-going development. Emphasis on glove development is necessary to provide low fatigue, dexterous glove mobility at higher suit pressures. Minimum impact hooks and scars which support an advanced SSF EMU have been identified. These accommodations permit upgrades that support servicing of low volume, high pressure oxygen systems, and hydrogen technologies such as fuel cell, and venting hydrogen heat rejection systems.

Rouen, M.↗

The space station tethered elevator system

The optimized conceptual engineering design of a space station tethered elevator is presented. The elevator is an unmanned mobile structure which operates on a ten kilometer tether spanning the distance between the Space Station and a tethered platform. Elevator capabilities include providing access to residual gravity levels, remote servicing, and transportation to any point along a tether. The potential uses, parameters, and evolution of the spacecraft design are discussed. Engineering development of the tethered elevator is the result of work conducted in the following areas: structural configurations; robotics, drive mechanisms; and power generation and transmission systems. The structural configuration of the elevator is presented. The structure supports, houses, and protects all systems on board the elevator. The implementation of robotics on board the elevator is discussed. Elevator robotics allow for the deployment, retrieval, and manipulation of tethered objects. Robotic manipulators also aid in hooking the elevator on a tether. Critical to the operation of the tethered elevator is the design of its drive mechanisms, which are discussed. Two drivers, located internal to the elevator, propel the vehicle along a tether. These modular components consist of endless toothed belts, shunt-wound motors, regenerative power braking, and computer controlled linear actuators. The designs of self-sufficient power generation and transmission systems are reviewed. Thorough research indicates all components of the elevator will operate under power provided by fuel cells. The fuel cell systems will power the vehicle at seven kilowatts continuously and twelve kilowatts maximally. A set of secondary fuel cells provides redundancy in the unlikely event of a primary system failure. Power storage exists in the form of Nickel-Hydrogen batteries capable of powering the elevator under maximum loads.

Anderson, Loren A.↗

An Overview of the Integrated Crate Interrogation System (ICIS) for use at the Savannah River Site

The Integrated Crate Interrogation System (ICIS) was developed for use at the Savannah River Site to assay transuranic waste in large containers. The system comprises a Box Segmented Gamma Scanner (BSGS) providing high resolution gamma spectroscopy, and a Box Neutron Assay System (BNAS) providing passive neutron counting capability. The multi-modality approach is taken where the assay results from the gamma and neutron systems are combined to complement each other in satisfying Waste Isolation Pilot Plant (WIPP) criteria. This paper gives an overview of the system that has been built, factory calibrated, and delivered to the site. The BSGS is similar to a standard Canberra Segmented Gamma Box Counter, but with the addition of a transmission option for ascertaining density and rudimentary fill-height information. This supplements the Multi-Curve approach based on efficiency in energy and density. The BSGS has a moving trolley which travels on rails through a passive emission counting station using large BEGe detectors, and a transmission counting station using NaI detectors in conjunction with high- and low-beam transmission stages. The assay result provides information on the Pu, Am and/or U isotopic ratios using standard isotopic analysis codes, quantitative measurement of Pu and U for low and medium density matrices, and direct measurement of other gamma emitters in the waste that are not identified in the isotopic measurement. It also provides basic positional information to improve the accuracy of both the gamma and the neutron measurement. The BNAS is a passive neutron coincidence counter intended for use with multiplicity counting of items of various geometries. The counter utilizes 320 {sup 3}He filled proportional counters arranged in a 4 {pi} geometry about the assay cavity and divided into 80 counting channels. The assay result provides the {sup 240}Pu-effective mass with which the gamma isotopic measurement is combined to provide reliable reporting of Pu and other isotopes. It also provides the total alpha activity that must be reported as part of the characterization requirements for WIPP (or bounds on the alpha activity based on the chemical form of the alpha-emitter). The neutron assay also complements the gamma results where matrix effects, self shielding or self absorption effects, and the presence of high-Z material, severely limits accuracy. Matrix moderator corrections for the neutron assay are based on a multi-position Add-A-Source correction augmented by a Modified Hydrogen Correction. The data acquisition also incorporates a Local Coincidence Veto circuit. Following the calibration of the system at the factory, confirmatory measurements were performed to demonstrate the validity of the calibrations, and to verify that the measurement system meets the Waste Acceptance Criteria established by DOE/WIPP. (authors)

54 ENVIRONMENTAL SCIENCES↗

Numerical simulation of iodine speciation in relation to water disinfection aboard manned spacecraft I. Equilibria

Elemental iodine (I2) is currently used as the drinking water disinfectant aboard the Shuttle Orbiter and will also be incorporated into the water recovery and distribution system for the International Space Station Alpha. Controlled release of I2 is achieved using the Microbial Check Valve (MCV), a flow-through device containing an iodinated polymer which imparts a bacteriostatic residual concentration of approximately 2mg/L to the aqueous stream. During regeneration of MCV canisters, I2 concentrations of approximately 300 mg/L are used. Dissolved iodine undergoes a series of hydrolytic disproportionation and related reactions which result in the formation of an array of inorganic species including: I-, I3-, HOI, OI-, IO3-, HIO3, I2OH-, I2O(-2), and H2OI+. Numerical estimation of the steady-state distribution of inorganic iodine containing species in pure water at 25 degrees C has been achieved by simultaneous solution of the multiple equilibrium expressions as a function of pH. The results are reported herein.

NASA Discipline Environmental Health↗

Sea Ice Effect on Arctic Precipitation Field Campaign Report

This campaign, entitled Sea Ice Effect on Arctic Precipitation, started in January 2010 and ended in December 2016. The campaign involved sampling precipitation, storm by storm, within the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility observatory at Barrow, Alaska. Before the ARM Atqasuq, Alaska site was closed in September, 2014, precipitation samples were also collected at Atqasuq. The objective of this campaign was to study how sea ice retreat under warming conditions affects the arctic hydrological cycle, namely evaporation and precipitation, using oxygen and hydrogen isotopic measurements in precipitation. One of the roles of sea ice in the arctic climate system is to influence evaporative fluxes from the sea surface. When sea ice melts, the evaporation is promoted from the newly opened sea surface, which increases the moisture supply, and precipitation. Reduction of sea ice cover may feed back to the climate system in several ways. First, it affects the latent heat flux from the sea surface. Second, the increased precipitation in the Arctic may change the surface albedo. For example, if the increased precipitation falls as snow, it would increase the albedo in spring due to delayed melting. Both mechanisms would affect the radiation balance of the Arctic and thus induce additional climate change. Stable isotopic ratios in precipitation record meteorological conditions from the moisture source through the transport path and to the precipitation site. If moisture from the arctic sea surface increases, the average transport distance would decrease. This would result in an enrichment of oxygen-18 and deuterium in precipitation. Samples collected at Barrow allow us to track the moisture source areas for each sampled storm and analyze if the sea ice change is associate with systematic shift of hydrological conditions. Between July 2011 and December 2014, Barrow was one of the sites in a network of pan-Arctic precipitation observations in the project called iisPacs, standing for Isotopic Investigation of Precipitation in Sea ice in the Arctic Climate System. The project included eight stations where precipitation was collected following the protocols developed in Barrow and Atqasuq. These stations included Barrow and Atqasuq, Alaska, Cambridge Bay, Canada, Ny Ålesund, Norway, Ikerasaarsuk and Summit, Greenland, and Chersky and Tiksi, Russia. Currently, synthesizing data from all of these stations is in progress.

arctic processes, sea ice, North Slope of Alaska, ↗

Dual Inhibitors of SARS-CoV-2 3CL Protease and Human Cathepsin L Containing Glutamine Isosteres Are Anti-CoV-2 Agents

SARS-CoV-2 3CL protease (Main protease) and human cathepsin L are proteases that play unique roles in the infection of human cells by SARS-CoV-2, the causative agent of COVID-19. Both proteases recognize leucine and other hydrophobic amino acids at the P 2 position of a peptidomimetic inhibitor. At the P 1 position, cathepsin L accepts many amino acid side chains, with a partial preference for phenylalanine, while 3CL-PR protease has a stringent specificity for glutamine or glutamine analogues. We have designed, synthesized, and evaluated peptidomimetic aldehyde dual-target (dual-acting) inhibitors using two peptide scaffolds based on those of two Pfizer 3CL-PR inhibitors, Nirmatrelvir, and PF-835321. Our inhibitors contain glutamine isosteres at the P 1 position, including 2-pyridon-3-yl-alanine, 3-pyridinyl-alanine, and 1,3-oxazo-4-yl-alanine groups. Inhibition constants for these new inhibitors ranged from K i = 0.6–18 nM (cathepsin L) and K i = 2.6–124 nM (3CL-PR), for which inhibitors with the 2-pyridon-3-yl-alanal substituent were the most potent for 3CL-PR. The anti-CoV-2 activity of these inhibitors ranged from EC 50 = 0.47–15 μM. X-ray structures of the peptidomimetic aldehyde inhibitors of 3CL-PR with similar scaffolds all demonstrated the formation of thiohemiacetals with Cys 145 , and hydrogen-bonding interactions with the heteroatoms of the pyridon-3-yl-alanyl group, as well as the nitrogen of the N-terminal indole and its appended carbonyl group at the P 3 position. The absence of these hydrogen bonds for the inhibitors containing the 3-pyridinyl-alanyl and 1,3-oxazo-4-yl-alanyl groups was reflected in the less potent inhibition of the inhibitors with 3CL-PR. In summary, our studies demonstrate the value of a second generation of cysteine protease inhibitors that comprise a single agent that acts on both human cathepsin L and SARS-CoV-2 3CL protease. Such dual-target inhibitors will provide anti-COVID-19 drugs that remain active despite the development of resistance due to mutation of the viral protease. Such dual-target inhibitors are more likely to remain useful therapeutics despite the emergence of inactivating mutations in the viral protease because the human cathepsin L will not develop resistance. This particular dual-target approach is innovative since one of the targets is viral (3CL-PR) required for viral protein maturation and the other is human (hCatL) which enables viral infection.

60 APPLIED LIFE SCIENCES↗

Ares V: Game Changer for National Security Launch

NASA is designing the Ares V cargo launch vehicle to vastly expand exploration of the Moon begun in the Apollo program and enable the exploration of Mars and beyond. As the largest launcher in history, Ares V also represents a national asset offering unprecedented opportunities for new science, national security, and commercial missions of unmatched size and scope. The Ares V is the heavy-lift component of NASA's dual-launch architecture that will replace the current space shuttle fleet, complete the International Space Station, and establish a permanent human presence on the Moon as a stepping-stone to destinations beyond. During extensive independent and internal architecture and vehicle trade studies as part of the Exploration Systems Architecture Study (ESAS), NASA selected the Ares I crew launch vehicle and the Ares V to support future exploration. The smaller Ares I will launch the Orion crew exploration vehicle with four to six astronauts into orbit. The Ares V is designed to carry the Altair lunar lander into orbit, rendezvous with Orion, and send the mated spacecraft toward lunar orbit. The Ares V will be the largest and most powerful launch vehicle in history, providing unprecedented payload mass and volume to establish a permanent lunar outpost and explore significantly more of the lunar surface than was done during the Apollo missions. The Ares V consists of a Core Stage, two Reusable Solid Rocket Boosters (RSRBs), Earth Departure Stage (EDS), and a payload shroud. For lunar missions, the shroud would cover the Lunar Surface Access Module (LSAM). The Ares V Core Stage is 33 feet in diameter and 212 feet in length, making it the largest rocket stage ever built. It is the same diameter as the Saturn V first stage, the S-IC. However, its length is about the same as the combined length of the Saturn V first and second stages. The Core Stage uses a cluster of five Pratt & Whitney Rocketdyne RS-68B rocket engines, each supplying about 700,000 pounds of thrust. Its propellants are liquid hydrogen and liquid oxygen. The two solid rocket boosters provide about 3.5 million pounds of thrust at liftoff. These 5.5-segment boosters are derived from the 4-segment boosters now used on the Space Shuttle, and are similar to those used in the Ares I first stage. The EDS is powered by one J-2X engine. The J-2X, which has roughly 294,000 pounds of thrust, also powers the Ares I Upper Stage. It is derived from the J-2 that powered the Saturn V second and third stages. The EDS performs two functions. Its initial suborbital burns will place the lunar lander into a stable Earth orbit. After the Orion crew vehicle, launched separately on an Ares I, docks with the lander/EDS stack, EDS will ignite a second time to put the combined 65-metric ton vehicle into a lunar transfer orbit. When it stands on the launch pad at Kennedy Space Center late in the next decade, the Ares V stack will be approximately 381 feet tall and have a gross liftoff mass of 8.1 million pounds. The current point-of-departure design exceeds Saturn V s mass capability by approximately 40 percent. Using the current payload shroud design, Ares V can carry 315,000 pounds to 29-degree low Earth orbit (LEO) or 77,000 pounds to a geosynchronous orbit. Another unique aspect of the Ares V is the 33-foot-diameter payload shroud, which encloses approximately 30,400 cubic feet of usable volume. A larger hypothetical shroud for encapsulating larger payloads has been studied. While Ares V makes possible larger payload masses and volumes, it may alternately make possible more cost-effective mission design if the relevant payload communities are willing to consider an alternative to the existing approach that has driven them to employ complexity to solve current launch vehicle mass and volume constraints. By using Ares V s mass and volume capabilities as margin, payload designers stand to reduce development risk and cost. Significant progress has been made on the Ares V to support a plaed fiscal 2011 authority-to-proceed (ATP) milestone. The Ares V team is actively reaching out to external organizations during this early concept phase to ensure that the Ares V vehicle can be leveraged for national security, science, and commercial development needs. This presentation will discuss Ares V vehicle configuration, the path to the current concept, accomplishments to date, and potential payload utilization opportunities.

Sumrall, Phil↗

Status of the investigation of the spin structure of d, {sup 3}H, and {sup 3}He at VBLHE using polarized and unpolarized deuteron beam

The investigation of the spin structure of d, {sup 3}H, and {sup 3}He has been performed at the RIKEN acceleration research facility and VBLHE. Vector A{sub y} and tensor A{sub yy}, A{sub xx}, A{sub xz} analyzing powers for d-bar-vector d {yields} {sup 3}Hen and d-bar-vector d {yields} {sup 3}Hp are presented at 270 MeV. The mirror channels ({sup 3}Hen and {sup 3}Hp) are compared to each other in order to find possible manifestation of charge-symmetry breaking. The preliminary results on the polarization observables for d-bar-vector d {yields} {sup 3}Hp at 200MeV are also presented. The obtained data are compared with one-nucleon-exchange calculations. As a byproduct, d-bar-vector d {yields} pX and d-bar-vector {yields} {sup 12}C {yields} pX breakup reactions are investigated at 140, 200, and 270MeV. The experimental data on d-bar-vector p elastic scattering were obtained at 270, 880, and 2000 MeV at the Nuclotron. The polarization of the deuteron beam was measured at 270 MeV at the internal target station. The preliminary data on the vector A{sub y} and tensor A{sub yy}, A{sub xx} analyzing powers for the d-bar-vector p elastic scattering at 880 MeV are presented. The calculations on A{sub y}, A{sub yy}, and A{sub xx} analyzing powers for the d-bar-vector p elastic scattering at 880 MeV were performed in the framework of the multiple-scattering model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗