Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy

The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3-50.4 Gy with daily fraction size of 1.7-2.0 Gy. Total dose to the scar PTV was prescribed to 58.0-60.2 Gy at 2.0-2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTV received 1.7-1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of image value-to-density table (IVDT) on the accuracy of delivery quality assurance (DQA) process in helical tomotherapy

The effect of the accuracy in the application of the image value-to-density table (IVDT) from kilovoltage computed tomography (kVCT) and mega-voltage computed tomography (MVCT) images on the delivery quality assurance (DQA) in helical tomotherapy (HT) was analyzed. The DQA plans were prepared with a kVCT image of a cheese phantom for 10 HT patients, and the difference in absolute dose equivalence between the planned and real measurement was evaluated according to the accuracy of IVDT application. The difference between the calculated dose distribution and real dose distribution measured with MapCHECK (SunNuclear, Melbourne, FL) was analyzed through the DQA process with a kVCT MapCHECK image and the same analysis was performed with an MVCT MapCHECK image. The IVDT for kVCT was applied to MVCT and the variation in error between the planned and real measurement caused by improper application of IVDT was evaluated. The accuracy of the IVDT application in the homogeneous water-equivalent cheese phantom had only a minor influence on the dose calculation. Although the overall accuracy of the calculated dose was increased when the proper IVDT was applied, this result had no statistical significance. The MVCT image of MapCHECK contained less error between the calculated dose and delivered dose with a high pass rate. The proper IVDT application to the MVCT image of MapCHECK increased the accuracy of dose calculation, and this result had a statistical significance. Application of the correct IVDT is important in HT DQA and its significance is increased when using phantoms consisting of inhomogeneous density materials.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implant breast reconstruction followed by radiotherapy: Can helical tomotherapy become a standard irradiation treatment?

To evaluate the benefits and limitations of helical tomotherapy (HT) for loco-regional irradiation of patients after a mastectomy and immediate implant-based reconstruction. Ten breast cancer patients with retropectoral implants were randomly selected for this comparative study. Planning target volumes (PTVs) 1 (the volume between the skin and the implant, plus margin) and 2 (supraclavicular, infraclavicular, and internal mammary nodes, plus margin) were 50 Gy in 25 fractions using a standard technique and HT. The extracted dosimetric data were compared using a 2-tailed Wilcoxon matched-pair signed-rank test. Doses for PTV1 and PTV2 were significantly higher with HT (V95 of 98.91 and 97.91%, respectively) compared with the standard technique (77.46 and 72.91%, respectively). Similarly, the indexes of homogeneity were significantly greater with HT (p = 0.002). HT reduced ipsilateral lung volume that received {>=}20 Gy (16.7 vs. 35%), and bilateral lungs (p = 0.01) and neighboring organs received doses that remained well below tolerance levels. The heart volume, which received 25 Gy, was negligible with both techniques. HT can achieve full target coverage while decreasing high doses to the heart and ipsilateral lung. However, the low doses to normal tissue volumes need to be reduced in future studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiobiologic comparison of helical tomotherapy, intensity modulated radiotherapy, and conformal radiotherapy in treating lung cancer accounting for secondary malignancy risks

The aim of the present study is to examine the importance of using measures to predict the risk of inducing secondary malignancies in association with the clinical effectiveness of treatment plans in terms of tumor control and normal tissue complication probabilities. This is achieved by using radiobiologic parameters and measures, which may provide a closer association between clinical outcome and treatment delivery. Overall, 4 patients having been treated for lung cancer were examined. For each of them, 3 treatment plans were developed based on the helical tomotherapy (HT), multileaf collimator-based intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (CRT) modalities. The different plans were evaluated using the complication-free tumor control probability (p{sub +}), the overall probability of injury (p{sub I}), the overall probability of control/benefit (p{sub B}), and the biologically effective uniform dose (D{sup ¯¯}). These radiobiologic measures were used to develop dose-response curves (p-D{sup ¯¯} diagram), which can help to evaluate different treatment plans when used in conjunction with standard dosimetric criteria. The risks for secondary malignancies in the heart and the contralateral lung were calculated for the 3 radiation modalities based on the corresponding dose-volume histograms (DVHs) of each patient. Regarding the overall evaluation of the different radiation modalities based on the p{sub +} index, the average values of the HT, IMRT, and CRT are 67.3%, 61.2%, and 68.2%, respectively. The corresponding average values of p{sub B} are 75.6%, 70.5%, and 71.0%, respectively, whereas the average values of p{sub I} are 8.3%, 9.3%, and 2.8%, respectively. Among the organs at risk (OARs), lungs show the highest probabilities for complications, which are 7.1%, 8.0%, and 1.3% for the HT, IMRT, and CRT modalities, respectively. Similarly, the biologically effective prescription doses (D{sub B}{sup ¯¯}) for the HT, IMRT, and CRT modalities are 64.0, 60.9, and 60.8 Gy, respectively. Regarding the risk for secondary cancer, for the heart, the lowest average risk is produced by IMRT (0.10%) compared with the HT (0.17%) and CRT (0.12%) modalities, whereas the 3 radiation modalities show almost equivalent results regarding the contralateral lung (0.8% for HT, 0.9% for IMRT, and 0.9% for CRT). The use of radiobiologic parameters in the evaluation of different treatment plans and estimation of their expected clinical outcome is shown to provide very useful clinical information. The radiobiologic analysis of the response probabilities showed that different radiation modalities appear to be more effective in different patient geometries and target sizes and locations. Furthermore, there is not a clear pattern between the plans that appear to be more effective for the treatment and the risk of secondary malignancy. It seems that radiobiologically based treatment planning taking into account the risk of secondary cancer can be established as an effective clinical tool for a more clinically relevant treatment optimization.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of helical tomotherapy, intensity-modulated radiation therapy, volumetric-modulated arc therapy, and 3-dimensional conformal therapy for the treatment of T1N0 glottic cancer

Various radiotherapy planning methods for T1N0 laryngeal cancer have been proposed to decrease normal tissue toxicity. We compare helical tomotherapy (HT), linac-based intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and 3-D conformal radiotherapy (3D-CRT) techniques for T1N0 laryngeal cancer. Overall, 10 patients with T1N0 laryngeal cancer were selected and evaluated. Furthermore, 10 radiotherapy treatment plans have been created for all 10 patients, including HT, IMRT, VMAT, and 3D-CRT. IMRT, VMAT, and HT plans vs 3D-CRT plans consistently provided superior planning target volume (PTV) coverage. Similar target coverage was observed between the 3 IMRT modalities. Compared with 3D-CRT, IMRT, HT, and VMAT significantly reduced the mean dose to the carotid arteries. VMAT resulted in the lowest mean dose to the submandibular and thyroid glands. Compared with 3D-CRT, IMRT, HT, and VMAT significantly increased the maximum dose to the spinal cord It was observed that the 3 IMRT modalities studied showed superior target coverage with less variation between each plan in comparison with 3D-CRT. The 3D-CRT plans performed better at the D{sub max} of the spinal cord. Clinical investigation is warranted to determine if these treatment approaches would translate into a reduction in radiation therapy–induced toxicities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of tumor location on the intensity-modulated radiation therapy plan of helical tomotherapy

Given the design of the Helical TomoTherapy device, the patient's central axis is routinely aligned with the machine's rotational axis to prevent the patient's body from colliding with the machine walls. However, for treatment of tumors located away from the patient's central axis, this position may not be optimal as the adequate radiation dose may not reach the affected site. Our study aimed to investigate the influence of tumor location on dose quality and delivery efficiency of tomotherapy plans. A phantom and 15 patients were selected for this study. Two plans, A and B, were implemented for each case. In plan A, the patient's central axis was aligned with the machine's rotational axis, whereas in plan B, the center of the planning target volume (PTV) was aligned with the machine's rotational axis. Both plans were optimized with the same planning parameters, and the dose quality of the plans was evaluated using dosimetrics. The delivery efficiency was determined from delivery time and monitor units (MUs). A paired t-test or nonparametric Wilcoxon signed-rank test was performed for statistical comparison. In the phantom study, the median delivery times were 358 and 336 seconds for plans A and B, respectively, and this difference was significant (p = 0.005). In the patient study, the median delivery times were 348 and 317 seconds for plans A and B, respectively, and this difference was also significant (p = 0.001). The dose qualities of both plans for each patient were nearly identical. No significant differences were found in the conformal index, heterogeneity index, and mean dose delivered to normal tissue between the plans. Both phantom and patient studies showed that for normal-sized patients, the delivery time reduced as the distance between the PTV and the patient's central axis increased when the PTV center was aligned with the machine axis. In conclusion, aligning the PTV center with the machine's rotational axis by shifting the patient during tomotherapy reduces the delivery time without compromising the dose quality of intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A helical-shape scintillating fiber trigger and tracker system for the DarkLight experiment and beyond

The search for new physics beyond the Standard Model has interesting possibilities at low energies. For example, the recent 6.8σ anomaly reported in the invariant mass of e + e - pairs from 8 Be nuclear transitions and the discrepancy between predicted and measured values of muon g-2 give strong motivations for a protophobic fifth-force model. At low energies, the electromagnetic interaction is well understood and produces straightforward final states, making it an excellent probe of such models. However, to achieve the required precision, an experiment must address the substantially higher rate of electromagnetic backgrounds. Here in this paper, we present the results of simulation studies of a trigger system, motivated by the DarkLight experiment, using helical-shape scintillating fibers in a solenoidal magnetic field to veto electron–proton elastic scattering and the associated radiative processes. We also assess the performance of a tracking detector for lepton final states using scintillating fibers in the same setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolution of the helicity and transversity Transverse-Momentum-Dependent parton distributions

We examine the QCD evolution of the helicity and transversity parton distribution functions when including also their dependence on transverse momentum. Using an appropriate definition of these polarized transverse momentum distributions (TMDs), we describe their dependence on the factorization scale and rapidity cutoff, which is essential for phenomenological applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nucleon helicity generalized parton distribution at physical pion mass from lattice QCD

The generalized parton distributions (GPDs) offer a window on three-dimensional imaging of the nucleon, providing understanding of how the fundamental properties of the nucleon, such as its mass and spin, arise from the underlying quark and gluon degrees of freedom. In this work, we present the first lattice calculation of the nucleon isovector helicity GPD at physical pion mass, using an a≈0.09 fm lattice ensemble with 2+1+1 flavors of highly improved staggered quarks generated by MILC Collaboration. We perform the GPD calculation in Breit frame using averaged nucleon boost momentum P z ≈2.2 GeV with nonzero momentum transfers in [0.2,1.0] GeV 2 . Nonperturbative renormalization in RI/MOM scheme is used to obtain the quasi-distribution before matching to the lightcone GPDs. The three-dimensional distribution $\tilde{H}$(x, Q 2 ) is presented, along with the three-dimensional nucleon tomography and impact-parameter-dependent distribution for selected Bjorken x at μ=3 GeV in $\overline{MS}$ scheme.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A comparison of turbulent transport in a quasi-helical and a quasi-axisymmetric stellarator

Ion-temperature-gradient-driven (ITG) turbulence is compared for two quasi-symmetric (QS) stellarator configurations to determine the relationship between linear growth rates and nonlinear heat fluxes. We focus on the quasi-helically symmetric (QHS) stellarator HSX and the quasi-axisymmetric (QAS) stellarator NCSX. In normalized units, HSX exhibits higher growth rates than NCSX, while heat fluxes in gyro-Bohm units are lower in HSX. These results hold for simulations made with both adiabatic and kinetic electrons. The results show that HSX has a larger number of subdominant modes than NCSX and that eigenmodes are more spatially extended in HSX. Furthermore, we conclude that the consideration of nonlinear physics is necessary to accurately assess the heat flux due to ITG turbulence when comparing QS stellarator equilibria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hierarchical Self-Assembly Pathways of Peptoid Helices and Sheets

Peptoids (N-substituted glycines) are a class of tailorable synthetic peptidomic polymers. Amphiphilic diblock peptoids have been engineered to assemble 2D crystalline lattices with applications in catalysis and molecular separations. Assembly is induced in an organic solvent/water mixture by evaporating the organic phase, but the assembly pathways remain uncharacterized. We conduct all-atom molecular dynamics simulations of Nbrpe6Nc6 as a prototypical amphiphilic diblock peptoid comprising an NH 2 -capped block of six hydrophobic N-((4-bromophenyl)ethyl)glycine residues conjugated to a polar NH 3 (CH 2 ) 5 CO tail. We identify a thermodynamically controlled assembly mechanism by which monomers assemble into disordered aggregates that self-order into 1D chiral helical rods then 2D achiral crystalline sheets. We support our computational predictions with experimental observations of 1D rods using small-angle X-ray scattering, circular dichroism, and atomic force microscopy and 2D crystalline sheets using X-ray diffraction and atomic force microscopy. Furthermore, this work establishes a new understanding of hierarchical peptoid assembly and principles for the design of peptoid-based nanomaterials.

59 BASIC BIOLOGICAL SCIENCES↗

Non-Covalent Interactions and Helical Packing in Thiophene-Phenylene Copolymers: Tuning Solid-State Ordering and Charge Transport for Organic Field-Effect Transistors

In this study, we introduce two thiophene-phenylene-thiophene (TPT) polymers designed to leverage noncovalent intramolecular interactions to regulate main-chain conformation and enhance solid-state ordering. By incorporating unsubstituted thiophene (T) or bithiophene (2T) units, we reveal striking divergence in the thermal, morphological, and optoelectronic properties of the resulting films, facilitated by these noncovalent interactions. Using a combination of computational and experimental approaches, we show that annealing yields remarkably different polymer conformations and, consequently, charge transport properties. TPT-T undergoes a significant structural transformation, adopting a more planar backbone conformation and a highly crystalline, edge-on molecular orientation. In contrast, the introduction of a single additional thiophene unit in TPT-2T leads to a more isotropic molecular orientation with a slight preference for face-on alignment, resulting in a heterogeneous film structure that hinders charge transport despite achieving tighter molecular packing. Remarkably, despite being composed of achiral components, TPT-2T develops chirality upon annealing, indicating the formation of a helical conformation. Organic field-effect transistor measurements reveal that the well-ordered alignment in annealed TPT-T films results in higher charge carrier mobility and a narrower distribution of mobility values than in TPT-2T. These findings provide critical insights into the structure−property relationships of conjugated polymers, offering guidance for optimizing molecular design and processing strategies for highperformance organic electronic materials.

36 MATERIALS SCIENCE↗

Quasi-One-Dimensional Structure and Possible Helical Antiferromagnetism of RbMn 6 Bi 5

Quasi-one-dimensional materials exhibit not only unique crystal structure but also abundant physical properties such as charge density wave, Luttinger liquid, and superconductivity. In this study, we report the discovery, structure, and physical properties of a new manganese-based quasi-one-dimensional material RbMn 6 Bi 5 , which crystallizes in a monoclinic space group C 2/ m (No. 12) with lattice parameters a = 23.286(5) Å, b = 4.6215(9) Å, c = 13.631(3) Å, and β = 125.00(3)°. The structure features [Mn 6 Bi 5 ] –1 double-walled column extending along the [010] direction, together with Bi–Bi homoatomic bonds linking the columns and the countercation Rb + . The temperature-dependent resistivity clearly indicates a significant resistivity anisotropy for RbMn 6 Bi 5 , whereas the magnetic susceptibility and specific heat measurements show that RbMn 6 Bi 5 is antiferromagnetic below 82 K. The density functional theory calculations indicate that RbMn 6 Bi 5 is a quasi-one-dimensional metal with possible helical antiferromagnetic configuration. The discovery of RbMn 6 Bi 5 confirms the viability of discovering new quasi-one-dimensional materials in manganese-based compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanomolar Sensitivity Chirality Transfer from Designed Helical Repeat Proteins to Achiral CdS Nanorods

Bridging chirality across length scales with inorganic− organic hybrid materials is a rapidly expanding area of research. Here, we establish asymmetry at CdS nanorod (NR) interfaces using a designed helical repeat protein bearing four cysteine residues (DHR- 4Cys). Hydrophobic NRs are transferred into water with glycine, and then glycine is displaced by DHR-4Cys, leveraging the thiophilicity of cadmium. Circular dichroism (CD) in the visible, coincident with CdS electronic transitions, reveals a chiral DHR-4Cys:CdS interface. Here, the dissymmetry factor [g-factor = 4.5 × 10 −4 (short NRs) and 5.0 × 10 −4 (long NRs)] is weakly dependent on the NR length, and CD persists at nanomolar protein loadings. Additionally, control experiments demonstrate that DHR-4Cys:CdS NR chirality is dictated by the local coordination of Cys with no significant contribution from the chiral secondary structure of the protein (g-factors of short and long Cys:CdS NRs are 4.8 × 10 −4 and 4.0 × 10 −4 , respectively). Together with far-UV CD and transmission electron microscopy, which provide evidence of preserved protein structure, these results provide the first demonstration that a structurally defined protein can induce chirality in CdS nanocrystals while maintaining protein structure at biologically relevant concentrations.

Cadmium sulfide↗

Evidence for Helical Hinge Zero Modes in an Fe-Based Superconductor

Combining topology and superconductivity provides a powerful tool for investigating fundamental physics as well as a route to fault-tolerant quantum computing. There is mounting evidence that the Fe-based superconductor FeTe 0.55 Se 0.45 (FTS) may also be topologically nontrivial. Should the superconducting order be s ± , then FTS could be a higher order topological superconductor with helical hinge zero modes (HHZMs). To test the presence of these modes, we have fabricated normal-metal/superconductor junctions on different surfaces via 2D atomic crystal heterostructures. As expected, junctions in contact with the hinge reveal a sharp zero bias anomaly that is absent when tunneling purely into the c-axis. Additionally, the shape and suppression with temperature are consistent with highly coherent modes along the hinge and are incongruous with other origins of zero bias anomalies. Additional measurements with soft-point contacts in bulk samples with various Fe interstitial contents demonstrate the intrinsic nature of the observed mode. Thus, we provide evidence that FTS is indeed a higher order topological superconductor.

2D superconductor↗

Emergence of a Low-Energy Peak in the Smoothed Absolute Value Circular Dichroism Spectra of Small Helical Gold Nanorods

We calculate, using time-dependent density functional theory, absorption and circular dichroism (CD) spectra for a series of small helical gold nanorod structures with a width of 0.6 nm and length increasing from 0.7 nm for Au 24 to 1.9 nm for Au 56 . For a low-energy window, ranging from 1.7 to 4.1 eV, broadening the lines in the absorption spectra results in a low energy peak which previous studies have identified as the (localized) plasmon resonance. As expected, the absorption peak position of the plasmon resonance systematically redshifts as the length of the nanorod increases. However, trends in the CD and straightforwardly broadened CD spectra are more difficult to discern. We introduce the idea of an absolute value CD spectrum and show that broadening the lines results in a low energy peak that has not previously been reported. The peak position systematically redshifts as the length of the nanorod increases but over a significantly smaller range than that for the absorption spectrum.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Structural Origins of Nitroxide Side Chain Dynamics on Membrane Protein [alpha]-Helical Sites

Understanding the structure and dynamics of membrane proteins in their native, hydrophobic environment is important to understanding how these proteins function. EPR spectroscopy in combination with site-directed spin labeling (SDSL) can measure dynamics and structure of membrane proteins in their native lipid environment; however, until now the dynamics measured have been qualitative due to limited knowledge of the nitroxide spin label's intramolecular motion in the hydrophobic environment. Although several studies have elucidated the structural origins of EPR line shapes of water-soluble proteins, EPR spectra of nitroxide spin-labeled proteins in detergents or lipids have characteristic differences from their water-soluble counterparts, suggesting significant differences in the underlying molecular motion of the spin label between the two environments. To elucidate these differences, membrane-exposed {alpha}-helical sites of the leucine transporter, LeuT, from Aquifex aeolicus, were investigated using X-ray crystallography, mutational analysis, nitroxide side chain derivatives, and spectral simulations in order to obtain a motional model of the nitroxide. For each crystal structure, the nitroxide ring of a disulfide-linked spin label side chain (R1) is resolved and makes contacts with hydrophobic residues on the protein surface. The spin label at site I204 on LeuT makes a nontraditional hydrogen bond with the ortho-hydrogen on its nearest neighbor F208, whereas the spin label at site F177 makes multiple van der Waals contacts with a hydrophobic pocket formed with an adjacent helix. These results coupled with the spectral effect of mutating the i {+-} 3, 4 residues suggest that the spin label has a greater affinity for its local protein environment in the low dielectric than on a water-soluble protein surface. The simulations of the EPR spectra presented here suggest the spin label oscillates about the terminal bond nearest the ring while maintaining weak contact with the protein surface. Combined, the results provide a starting point for determining a motional model for R1 on membrane proteins, allowing quantification of nitroxide dynamics in the aliphatic environment of detergent and lipids. In addition, initial contributions to a rotamer library of R1 on membrane proteins are provided, which will assist in reliably modeling the R1 conformational space for pulsed dipolar EPR and NMR paramagnetic relaxation enhancement distance determination.

08 HYDROGEN↗