Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas Separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Weak Lensing Results of the Merging Cluster A1758

Here we present the weak lensing results of A1758, which is known to have four cluster members undergoing two separate mergers, A1758N and A1758S. Weak lensing results of A1758N agree with previous weak lensing results of clusters lE0657-558 (Bullet cluster) and MACS J0025.4-1222, whose X-ray gas components were found to be largely separated from their clusters' gravitational potentials. A1758N has a geometry that is different from previously published mergers in that one of its X-ray peaks overlays the corresponding gravitational potential and the other X-ray peak is well separated from its cluster's gravitational potential.

Markevitch, M.↗

University of Minnesota, Twin Cities Final Scientific/Technical Report Small Scale Ammonia Synthesis Using Stranded Wind Energy

Ammonia absorber columns offer an alternative separation unit to replace condensation in the Haber-Bosch synthesis loop. Metal halide salts can selectively separate ammonia from the reactor outlet gas mixture and incorporate it into their crystal lattice with remarkably high thermodynamic capacity. While the salts’ working capacity can be limited and unstable when they are in their pure form, the capacity is stable and can be high when using a porous ceramic support. In this project, we found optimal conditions for sorbent fabrication, we demonstrated benchmark levels of uptake and release of ammonia, and we fabricated and demonstrated a prototype at a scale of 1 kg/day ammonia. This task allowed us to assess improvement in the techno-economic prospects for this new separation approach, making viable more distributed production of green ammonia from geographically dispersed renewable energy sources.

08 HYDROGEN↗

Ultra-selective CANAL Polymers for Hydrogen-based Membrane Separations after Long-Term Aging

Hydrogen is a critically important molecule in the chemicals and energy industries, driving the need for efficient purification technologies such as membrane-based separations. However, polymer membranes often suffer from physical aging, leading to decreased gas permeability over time. This study leverages the unique aging behavior of contorted microporous polymers, synthesized via catalytic arene-norbornene annulation (CANAL) polymerization, to enhance molecular sieving for H 2 separations. While prior studies demonstrated a 1000% increase in H 2 /CH 4 selectivity with minimal permeability loss over 150 days, we extend this investigation to hyperaged (∼1 year) CANAL polymers and evaluate their performance under various conditions of industrial relevance. We report a remarkable 6100% increase in H 2 /CH 4 selectivity and a 2400% improvement in H 2 /N 2 selectivity, with only a 55% decline in H 2 permeability. These membranes exhibit excellent long-term stability in binary and ternary gas mixtures and at elevated temperatures. Additionally, extended aging enhances H 2 /CO 2 selectivity beyond the 2008 upper bound due to improved size-sieving. High-temperature permeation experiments and grand canonical Monte Carlo simulations reveal that H 2 permeability increases from 570 to 3500 barrer as the temperature rises from 35 °C to 190 °C, while H 2 /CO 2 selectivity declines from 14 to 3 due to the higher diffusion activation energy of CO 2 . Despite this tradeoff, hyperaged CANAL membranes maintain performance beyond the 200 °C upper bound, having selectivity–permeability performance comparable to many state-of-the-art membranes for H 2 /CO 2 separations. As a result, this study highlights the robustness and industrial viability of ultra-selective CANAL polymers for hydrogen purification, contributing to advancements in clean energy and sustainable separation technologies.

36 MATERIALS SCIENCE↗

Membrane-Based Gas Traps for Ammonia, Freon-21, and Water Systems to Simplify Ground Processing

Gas traps are critical for the smooth operation of coolant loops because gas bubbles can cause loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and blockage of passages to remote systems. Coolant loops are ubiquitous in space flight hardware, and thus there is a great need for this technology. Conventional gas traps will not function in micro-gravity due to the absence of buoyancy forces. Therefore, clever designs that make use of adhesion and momentum are required for adequate separation, preferable in a single pass. The gas traps currently used in water coolant loops on the International Space Station are composed of membrane tube sets in a shell. Each tube set is composed of a hydrophilic membrane (used for water transport and capture of bubbles) and a hydrophobic membrane (used for venting of air bubbles). For the hydrophilic membrane, there are two critical pressures, the pressure drop and the bubble pressure. The pressure drop is the decrease in system pressure across the gas trap. The bubble pressure is the pressure required for air bubbles to pass across the water filled membrane. A significant difference between these pressures is needed to ensure complete capture of air bubbles in a single pass. Bubbles trapped by the device adsorb on the hydrophobic membrane in the interior of the hydrophilic membrane tube. After adsorption, the air is vented due to a pressure drop of approximately 1 atmosphere across the membrane. For water systems, the air is vented to the ambient (cabin). Because water vapor can also transport across the hydrophobic membrane, it is critical that a minimum surface area is used to avoid excessive water loss (would like to have a closed loop for the coolant). The currently used gas traps only provide a difference in pressure drop and bubble pressure of 3-4 psid. This makes the gas traps susceptible to failure at high bubble loading and if gas venting is impaired. One mechanism for the latter is when particles adhere to the hydrophobic membrane, promoting formation of a water layer about it that can blind the membrane for gas transport (Figure 1). This mechanism is the most probable cause for observed failures with the existing design. The objective of this project was to devise a strategy for choosing new membrane materials (database development and procedure), redesign of the gas trap to mitigate blinding effects, and to develop a design that can be used in ammonia and Freon-21 coolant loops.

Ritchie, Stephen M. C.↗

Sample Acquisition and Analytical Chemistry Challenges to Verifying Compliance to Aviators Breathing Oxygen (ABO) Purity Specification

NASA has been developing and testing two different types of oxygen separation systems. One type of oxygen separation system uses pressure swing technology, the other type uses a solid electrolyte electrochemical oxygen separation cell. Both development systems have been subjected to long term testing, and performance testing under a variety of environmental and operational conditions. Testing these two systems revealed that measuring the product purity of oxygen, and determining if an oxygen separation device meets Aviator's Breathing Oxygen (ABO) specifications is a subtle and sometimes difficult analytical chemistry job. Verifying product purity of cryogenically produced oxygen presents a different set of analytical chemistry challenges. This presentation will describe some of the sample acquisition and analytical chemistry challenges presented by verifying oxygen produced by an oxygen separator - and verifying oxygen produced by cryogenic separation processes. The primary contaminant that causes gas samples to fail to meet ABO requirements is water. The maximum amount of water vapor allowed is 7 ppmv. The principal challenge of verifying oxygen produced by an oxygen separator is that it is produced relatively slowly, and at comparatively low temperatures. A short term failure that occurs for just a few minutes in the course of a 1 week run could cause an entire tank to be rejected. Continuous monitoring of oxygen purity and water vapor could identify problems as soon as they occur. Long term oxygen separator tests were instrumented with an oxygen analyzer and with an hygrometer: a GE Moisture Monitor Series 35. This hygrometer uses an aluminum oxide sensor. The user's manual does not report this, but long term exposure to pure oxygen causes the aluminum oxide sensor head to bias dry. Oxygen product that exceeded the 7 ppm specification was improperly accepted, because the sensor had biased. The bias is permanent - exposure to air does not cause the sensor to return to its original response - but the bias can be accounted for by recalibrating the sensor. After this issue was found, continuous measurements of water vapor in the oxygen product were made using an FTIR. The FTIR cell is relatively large, so response time is slow - but moisture measurements were repeatable and accurate. Verifying ABO compliance for oxygen produced by commercial cryogenic processes has a different set of sample acquisition and analytical chemistry challenges. Customers want analytical chemists to conserve as much as possible. Hygrometers are not exposed to hours of continuous flow of oxygen, so they don't bias, but small amounts of contamination in valves can cause a "fail". K bottles are periodically cleaned and recertified - after cleaning residual moisture can cause a "fail". Operators let bottle pressure drop to room pressure, introduce outside air into the bottle, and the subsequent fill will "fail". Outside storage of K‐bottles has allowed enough in‐leakage, so contents will "fail".

Graf, John↗

Development of Carbon Molecular Sieves Hollow Fiber Membranes based on Polybenzimidazole Doped with Polyprotic Acids with Superior H 2 /CO 2 Separation Properties (Final Report)

The goal of this project was to develop a highly efficient membrane-based process to capture CO 2 from coal-derived syngas with 95% CO 2 purity, achieving the cost of electricity (COE) 30% below the baseline capture approaches (i.e., Selexol process) when coupled with the advancement in other areas of the power generation facility. Our core approach is based on high-permeance hollow fiber membranes (HFMs) with superior H 2 /CO 2 separation properties at the syngas process conditions, which can then be further utilized to design membrane reactors for process intensification of H 2 production and purification and CO 2 capture. Three organizations with complementary skills collaborated to achieve the goal, including the University at Buffalo (UB), Los Alamos National Laboratory (LANL), and Trimeric Corporation (Trimeric). We formulated logical steps to bring the membrane technology from Technology Readiness Level (TRL) 3 (Experimental proof of concept) to TRL 4 (Laboratory scale validation in relevant environment). During the budget period (BP) 1, we screened various polymeric materials and identified polybenzimidazole doped with inorganic polyprotic acids as the desirable platform. The acid doping increases the H 2 /CO 2 selectivity, and the sequential carbonization increases H 2 permeability while retaining the high selectivity. By manipulating the acid type and doping level and the carbonization temperature, we demonstrated advanced carbon molecular sieving (CMS) materials with H 2 permeability of above 200 Barrer (1 Barrer = 10 -10 cm 3 (STP) cm cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of above 40 at 200-300°C with simulated syngas containing CO and water vapor. For example, the PBI-(H 3 PO 4 ) 0.11 carbonized at 700 °C exhibits H 2 permeability of 200 Barrer and H 2 /CO 2 selectivity of 60 at 200 °C, and H 2 permeability of 240 Barrer and H 2 /CO 2 selectivity of 54 at 225 °C, which meets the targeted properties and surpasses Robeson’s upper bound. During the BP2, we focused on the conversion of the advanced CMS materials to stable HFMs. Membranes with H 2 permeance of 1,090 GPU (1 GPU = 10 -6 cm 3 (STP) cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of 57 at 300 °C were successfully fabricated. The effects of temperature, gas compositions, pressure, and time on the separation properties were systematically investigated. Pencil modules were continuously evaluated for 219 h (dry pure gas) and 669 h (dry simulated syngas) and showed initial decline in permeance and increased H 2 /CO 2 selectivity over time, ultimately achieving a steady state stable value, indicating that the ageing phenomena in the nanoporous structures of the membranes during the test. Membrane reactors were fabricated based on the CMS membranes and evaluated for water-gas shift (WGS) reaction. The use of membranes slightly improves the conversion of the CO. However, parametric tests of the membrane reactors at various temperatures and flow rates need to be conducted, as well as the membranes with improved separation performance. We performed a sensitivity analysis on the impact of H 2 /CO 2 selectivity on the COE based on a hybrid process of a membrane unit and cryogenic unit developed by Membrane Technology and Research, Inc. (MTR). Three H 2 /CO 2 selectivity (40, 60, and 15) cases were developed and compared with the baseline capture process (Case B5B) provided by the DOE report. Increasing the membrane H 2 /CO 2 selectivity reduces COE, but the rate of the decrease of COE also diminishes. The COE values for H 2 /CO 2 selectivities of 40 and 60 were nearly the same. As the H 2 /CO 2 selectivity increases, the inert recycling decreases, leading to smaller equipment, less auxiliary power requirements, and less heating, cooling, and refrigeration duty. The refrigeration system used to liquefy the CO 2 is the most expensive piece of equipment and consumes the most electricity within the CO 2 capture process. Increasing the CO 2 concentration in the recycle stream would improve the economics of the process by reducing the refrigeration duty requirement of the unit and also allow for higher liquefaction temperatures. The high H 2 -selective membrane developed by our team may be applicable in other separation processes where lower pressure H 2 retains value. Typically, hydrogen retains its pressure when it is separated from syngas components. Residual components may be used as low-quality fuel and then vented to the atmosphere. Applications might include control of H 2 /CO ratios or mitigation of the water gas shift reaction by CO 2 recycling to the feed of a gasifier or steam methane reformer. To summarize, we have developed industrial HFMs with the best H 2 /CO 2 separation performance reported in the literature. The membranes demonstrate stability with simulated syngas and show great potential for membrane reactors for WGS reactions, lowering the cost of blue H 2 production.

20 FOSSIL-FUELED POWER PLANTS↗

Spatially Resolved Galactic Wind in Lensed Galaxy RCSGA 032727-132609

We probe the spatial distribution of outflowing gas along four lines of sight separated by up to 6 kpc in a gravitationally lensed star-forming galaxy at z = 1.70. Using Mg II and Fe II emission and absorption as tracers, we find that the clumps of star formation are driving galactic outflows with velocities of − 170 to − 250 km/s. The velocities of Mg II emission are redshifted with respect to the systemic velocities of the galaxy, consistent with being backscattered. By contrast, the Fe II fluorescent emission lines are either slightly blueshifted or at the systemic velocity of the galaxy. Taken together, the velocity structure of the Mg II and Fe II emission is consistent with arising through scattering in galactic winds. Assuming a thin shell geometry for the outflowing gas, the estimated masses carried out by these outflows are large (approx 30-50 M/yr), with mass loading factors several times the star formation rate. Almost 20 per cent to 50 per cent of the blueshifted absorption probably escapes the gravitational potential of the galaxy. In this galaxy, the outflow is 'locally sourced', that is, the properties of the outflow in each line of sight are dominated by the properties of the nearest clump of star formation; the wind is not global to the galaxy. The mass outflow rates and the momentum flux carried out by outflows in individual star-forming knots of this object are comparable to that of starburst galaxies in the local Universe.

Bordoloi, Rongmon↗

Enzyme-based CO2 capture for advanced life support

Elevated CO2 levels in air can lead to impaired functioning and even death to humans. Control of CO2 is critical in confined spaces that have little physical or biological buffering capacity (e.g., spacecraft, submarines, or aircraft). A novel enzyme-based contained liquid membrane bioreactor was designed for CO2 capture and certain application cases are reported in this article. The results show that the liquid layer accounts for the major transport resistance. With addition of carbonic anhydrase, the transport resistance decreased by 71%. Volatile organic compounds of the type and concentration expected to be present in either the crew cabin or a plant growth chamber did not influence carbonic anhydrase activity or reactor operation during 1-day operation. Alternative sweep method studies, examined as a means of eliminating consumables, showed that the feed gas could be used successfully in a bypass mode when combined with medium vacuum pressure (-85 kPa) to achieve CO2 separation comparable to that with an inert sweep gas. The reactor exhibited a selectivity for CO2 versus N2 of 1400:1 and CO2 versus O2 is 866:1. The CO2 permeance was 1.44 x 10(-7) mol m-2 Pa-1 s-1 (4.3 x 10(-4) cm3 cm-2 s-1 cmHg-1) at a feed concentration of 0.1% CO2. These data show that the enzyme-based contained liquid membrane is a promising candidate technology that may be suitable for NASA applications to control CO2 in the crew or plant chambers.

NASA Discipline Life Support Systems↗

On Parametric Sensitivity of Reynolds-Averaged Navier-Stokes SST Turbulence Model: 2D Hypersonic Shock-Wave Boundary Layer Interactions

Examined is sensitivity of separation extent, wall pressure and heating to variation of primary input flow parameters, such as Mach and Reynolds numbers and shock strength, for 2D and Axisymmetric Hypersonic Shock Wave Turbulent Boundary Layer interactions obtained by Navier-Stokes methods using the SST turbulence model. Baseline parametric sensitivity response is provided in part by comparison with vetted experiments, and in part through updated correlations based on free interaction theory concepts. A recent database compilation of hypersonic 2D shock-wave/turbulent boundary layer experiments extensively used in a prior related uncertainty analysis provides the foundation for this updated correlation approach, as well as for more conventional validation. The primary CFD method for this work is DPLR, one of NASA's real-gas aerothermodynamic production RANS codes. Comparisons are also made with CFL3D, one of NASA's mature perfect-gas RANS codes. Deficiencies in predicted separation response of RANS/SST solutions to parametric variations of test conditions are summarized, along with recommendations as to future turbulence approach.

Hypersonic↗

Cluster Observations for Combined X-Ray and Sunyaev-Zel'dovich Estimates of Peculiar Velocities and Distances

Measurements of the peculiar velocities of galaxy clusters with respect to the Hubble flow allow the determination of the gravitational field from all matter in the universe, not just the visible component. The Sunyaev-Zel'dovich (SZ) effect (the inverse-Compton scattering of cosmic microwave background photons by the hot gas in clusters of galaxies) allows these velocities to be measured without the use of empirical distance indicators. Additionally, because the magnitude of the SZ effect is independent of redshift, the technique can be used to measure velocities out to the epoch of cluster formation. The SZ technique requires a determination of the temperature of the hot cluster gas from X-ray observations, and measurements of the SZ effect at millimeter wavelengths to separate the contribution from the thermal motions within the gas from that of the cluster peculiax velocity. We have constructed a bolometric receiver, the Sunyaev-Zel'dovich Infrared Experiment, specifically to make measurements of the SZ effect at millimeter wavelengths in order to apply the SZ technique to peculiar velocity measurements. This receiver has already been used to set limits to the peculiar velocities of two galaxy clusters at z approx. 0.2. As a test of the SZ technique, the double cluster pair Abell 222 and 223 was selected for observation. Measurements of the redshifts of the two components suggest that, if the clusters are gravitationally bound, they should exhibit a relative velocity of 10OO km/ s, well above the expected precision of 200 km/ s (set by astrophysical confusion) that is expected from the SZ method. The temperature can be measured from ASCA data which we obtained for this cluster pair. However, in order to ensure that the temperature estimate from the ASCA data was not dominated by cooling flows within the cluster, we requested ROSAT HRI observations of this cluster pair. Analysis of the X-ray properties of the cluster pair is continuing by combining the ROSAT observations funded under this proposal, archival PSPC data and our own PI ASCA data. The imaging data shows that neither cluster has a strong cooling flow, although A223 is the more compact of the two components. A223 also has a sub-cluster projected 1 Mpc to the North. The observed properties of this cluster pair are strikingly similar to those of the well-studied pair of A399 and A401 which are widely believed to be interacting and are in the initial stages of merging. This strengthens our selection of this cluster pair as a test for cluster peculiar motions. Combining these X-ray observations with SUZIE measurements of the SZ effect will provide important constraints on cluster merger models. This part of the program has been heavily delayed by bad weather at Mauna Kea, however SZ observations were obtained in November 1997 as part of a separately funded effort. These data are currently being analyzed.

Lange, A. E.↗

Review of Release Behavior of Hydrogen & Natural Gas Blends from Pipelines

Hydrogen can be used to reduce carbon emissions by blending into other gaseous energy carriers, such as natural gas. However, hydrogen blending into natural gas has important implications for safety which need to be evaluated. Hydrogen has different physical properties than natural gas, and these properties affect safety evaluations concerning a leak of the blended gas. The intent of this report is to begin to investigate the safety implications of blending hydrogen into the natural gas infrastructure with respect to a leak event from a pipeline. A literature review was conducted to identify existing data that will better inform future hazard and risk assessments for hydrogen/natural gas blends. Metrics with safety implications such as heat flux and dispersion behavior may be affected by the overall blend ratio of the mixture. Of the literature reviewed, there was no directly observed separation of the hydrogen from the natural gas or methane blend. No literature was identified that experimentally examined unconfined releases such as concentration fields or concentration at specific distances. Computational efforts have predicted concentration fields by modified versions of existing engineering models, but the validation of these models is limited by the unavailability of literature data. There are multiple literature sources that measured flame lengths and heat flux values, which are both relevant metrics to risk and hazard assessments. These data can be more directly compared to the outputs of existing engineering models for validation.

03 NATURAL GAS↗

Electrochemical Ammonia Compression

An electrochemical (EC) compressor is a solid-state compression device. For decades, researchers have been studying EC compressors for applications for a variety of energy systems. As the world transitions away from fossil fuel energy sources, EC compression emerges as a promising technique for energy storage, specifically energy stored in the form of pressurized ammonia. Ammonia is also a commonly used refrigerant. The present studies examine the viability of EC compression for ammonia storage and refrigeration. EC ammonia compression increases the concentration of an ammonia-hydrogen mixture via the input of electrical energy and a series of chemical reactions. A polymer electrolyte membrane separates the low-concentration side from the high-concentration side of the device. On the low-pressure (anode) side hydrogen atoms oxidize and react with ammonia molecules, forming positively charge ammonium ions. The ions traverse the membrane electrolytically. The ammonium ions are reduced and revert back to hydrogen and ammonia upon reaching the high-pressure (cathode). An external circuit provides the current needed to sustain the reactions. In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm2 of active area. We demonstrated the operation of larger cells with 100 cm2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state. We analyzed the effects of pressure and current on the EC compressor performance. We measured the flow rates of gas leaving the compressors and analyzed the composition using gas chromatography. We tested methods of separating ammonia from the effluent vapor, which contained hydrogen and water vapor. We found that back diffusion adversely affected the performance, especially when we maintained high pressure lifts.

25 ENERGY STORAGE↗

Microreactor System Design for a NASA In Situ Propellant Production Plant on Mars

The NASA In Situ Resource Utilization (ISRU) program is planning near-term missions to Mars that will include chemical processes for converting the carbon dioxide (CO2) and possibly water from the Martian environment to propellants, oxygen, and other useful chemicals. The use of indigenous resources reduces the size and weight of the payloads from Earth significantly, representing enormous cost savings that make human exploration of Mars affordable. Extraterrestrial chemical processing plants will need to be compact, lightweight, highly efficient under reduced gravity, and extraordinarily reliable for long periods. Microchemical and thermal systems represent capability for dramatic reduction in size and weight, while offering high reliability through massive parallelization. In situ propellant production (ISPP), one aspect of the ISRU program, involves collecting and pressurizing atmospheric CO2, conversion reactions, chemical separations, heat exchangers, and cryogenic storage. A preliminary system design of an ISPP plant based on microtechnology has demonstrated significant size, weight, and energy efficiency gains over the current NASA baseline. Energy management is a strong driver for Mars-based processes, not only because energy is a scarce resource, but because heat rejection is problematic; the low pressure environment makes convective heat transfer ineffective. Energy efficiency gains are largely achieved in the microchemical plant through extensive heat recuperation and energy cascading, which has a small size and weight penalty because the added micro heat exchangers are small. This leads to additional size and weight gains by reducing the required area of waste heat radiators. The microtechnology-based ISPP plant is described in detail, including aspects of pinch analysis for optimizing the heat exchanger network. Three options for thermochemical compression Of CO2 from the Martian atmosphere, adsorption, absorption, and cryogenic freezing, are presented, as well as three options for water decomposition, low temperature electrolysis, high temperature electrolysis, and thermochemical decomposition. Other elements of the plant include Sabatier and reverse water gas shift reactors, water recovery, chemical separations, and cryogenic storage. Data are presented supporting preliminary sizing of components, and results of the system design are compared to the existing NASA baseline that is based on conventional technologies.

TeGrotenhuis, W. E.↗

Rare gas analysis of size fractions from the Fayetteville meteorite

Eight size separates of grains from the Fayetteville meteorite ranging from less than 20 microns to greater than 1 millimeter are being analyzed for their rare gas elemental and isotopic composition. Measurements on five samples were performed. All five reveal a mixture of solar, planetary, cosmic ray produced and radiogenic gases. The solar component is of particular interest since it suggest that the meteorite may represent a fragment of an ancient protoplanetary regolith which was exposed to the solar wind. Solar wind elements are implanted in the outer few hundred Angstroms of exposed grains and are therefore expected to be surface correlated. At present the data do not suggest that such a correlation exists, but the final conclusion must await further analyses and data reduction.

Jordan, Jim L.↗

Untapped Benefits of Porous Liquids for Gas Capture: Low-Energy Regeneration

Current liquid-phase gas capture materials incur high operational costs due to energy-intensive regeneration processes, creating an industrial need for alternative materials that retain engineering benefits while reducing energy requirements. Porous liquids (PLs), liquid-phase materials with permanent internal porosity, have emerged as promising replacements with excellent gas absorption capacity and selectivity. Despite these benefits, evaluation of regeneration in PLs remains rare. In this Perspective, we evaluate the effects of solvent interactions, mass transport, and binding site formation that control PL regeneration. While conventional regeneration methods exist in PLs, the diversity of PL compositions allows for novel regeneration processes including light irradiation via use of photosensitive azobenzene-based cages, isostatic compression to collapse internal pore structures, and localized heating via sonication for gas desorption. In conclusion, the wide variability in porous host materials that generate the internal porosity in PLs facilitates innovative low-energy regeneration pathways, positioning them as a transformative solution in separation technologies.

gas capture↗

Analysis of Organoiodide Adsorption Mechanisms

If the United States were to engage in the reprocessing of used nuclear fuel, radioactive iodine must be removed from multiple plant off-gas streams to comply with governing regulations. One of these streams is the vessel off-gas (VOG), which arises from the separations process and is expected to contain iodine in primarily organic iodine forms and at parts-per-billion concentrations. The relative lack of knowledge surrounding organic iodine removal from the VOG prompted the US Department of Energy’s Office of Nuclear Energy to initiate experimental efforts targeted at understanding organic iodide removal from prototypic VOG streams. At Oak Ridge National Laboratory (ORNL), this effort has focused on developing a comprehensive understanding of iodine removal from VOG streams by using silver-based sorbents. An important aspect of this testing is developing an understanding of how the sorption of methyl iodide (CH 3 I), the most studied organic iodide species to date, compares with the sorption of other volatile organic iodide species potentially present in the VOG. The work presented here reflects initial testing that will continue to be developed, and final results will be incorporated into an end-of-year report that details a multiyear testing campaign designed to understand iodine mitigation from VOG streams. The goal of these experiments was to determine whether similar reaction pathways govern both CH 3 I and iodobutane (C 4 H 9 I) sorption onto silver mordenite (AgZ), a common silver-based iodine sorbent. More specifically, the authors hypothesized that the sorption of C 4 H 9 I by AgZ will result in the formation of butanol (C 4 H9OH). Effluent monitoring of CH 3 I sorption testing has confirmed methanol production, but analogous monitoring of effluents from C 4 H 9 I sorption studies has not been performed. A series of tests was completed to test this hypothesis with the aim of detecting C 4 H 9 OH downstream of the AgZ bed. Test conditions varied the bed depth, gas stream humidity, and bed temperature post sorption. The effluent gas stream downstream of the AgZ bed was sampled by using gas-tight syringes, and these samples were analyzed by a gas chromatograph coupled to a mass spectrometer. Thin bed C 4 H 9 I tests conducted at -65 and 0°C dew points did not result in C 4 H 9 OH detection in the effluent. This suggests that the sorption mechanism and subsequent reactions could be different from those observed for CH 3 I. The sorption testing continues; additional results will be included in final end-of-year report and will increase the fundamental understanding of organic iodide sorption by AgZ from VOG streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Macrovoid-free high performance polybenzimidazole hollow fiber membranes for elevated temperature H 2 /CO 2 separations

Thermally robust membranes are required for H 2 production and carbon capture from hydrocarbon fuel derived synthesis (syn) gas. Polybenzimidaole (PBI) materials have exceptional thermal, chemical and mechanical characteristics and high H 2 perm-selectivity for efficient syngas separations at process relevant conditions. The large gas volumes processed mandate the use of a high-throughput, small footprint hollow fiber membrane (HFM) platform. Here in this work, an industrially attractive spinning protocol is developed to fabricate PBI HFMs with unprecedented H 2 /CO 2 separation performance. A unique dope composition incorporating an acetonitrile diluent is discovered enabling asymmetric macro-void free PBI HFM fabrication using a water coagulant. The influences of dope viscosity, coagulant chemistry, and air gap on HFM morphology are evaluated. Elevated temperature (up to 350 °C) H 2 permeances of 400 GPU with H 2 /CO 2 selectivities > 20 are achieved. This unprecedented separation performance is a ground breaking achievement at temperatures traditionally considered out-of-reach for polymeric membranes.

08 HYDROGEN↗

Catalytic Hydrogenolysis of Polyethylene Under Reactive Separation

Deconstruction of polyolefins by catalytic hydrogenolysis is typically accompanied by the generation of undesired light gases. At reaction temperatures, the desired liquid products also tend to be volatile. Secondary cleavage of these liquid products contributes to light gas formation. The latter process was mitigated by reactive separation, continuously separating the liquid products from the catalyst throughout the experiment. At equivalent conversion, the yield and selectivity for oligomeric liquid species are increased under reactive separation, even though the carbon–carbon bond cleavage rate is slower than that in sealed experiments. More light gas is formed in the sealed reactor. Under 1 atm H 2 partial pressure, alkenes accompany the typical alkane hydrogenolysis products. Further, the alkene yield is higher, with greater selectivity for valuable α-olefins under reactive separation. These results provide the mechanistic insight that terminal alkenes are primary products of carbon–carbon bond cleavage during hydrogenolysis under experimental conditions, and secondary deconstruction of these species produces light gases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗