Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Investigation of the Glen Torridon Clay-Bearing Unit and Overlying Greenheugh Pediment by the Sample Analysis at Mars Instrument Suite

Exploring the Glen Torridon (GT) clay-bearing unit in Gale crater has long been a prime goal for the Mars Science Laboratory (MSL) because of spectral signatures of smectite identified from orbit. Smectite clay minerals can indicate habitable environments [1,2] and possibly facilitate the preservation of organic compounds [e.g., 3-7].Also, sulfate-bearing layers overlie GT and this sequence may record a large-scale change in aqueous conditions overtime [8].The Sample Analysis at Mars (SAM) instrument suitehas been essential in understanding volatile-bearing phases in Gale crater materials. SAM EGA has detected H2O, CO2, O2, H2, SO2, H2S, HCl, NO, and other trace gases, including organic fragments, evolved from many samples on heating. The identity and evolution temperature of evolved gases can support mineral detection by CheMin instrument X-ray diffraction (XRD)and place constraints on trace volatile-bearing phases, clay mineral compositions, and X-ray amorphous materials. In GT, SAM analyzed the sample Kilmarie (KM) from the Jura member, Glen Etive (GE), Mary Anning (MA) and Groken (GR)from the Knockfarril Hill member (KHm), Glasgow (GG) and Hutton (HU) from the fractured Intermediate Unit (fIU), and Edinburgh (EB) from the Stimson formation rocks of the Greenheugh Pediment (GP). The Jura, KHm and fIU are all members of the Murray formation. HU was sampled near the basal Siccar Point group (SPg) unconformity between the fIU and GP, in an area that exhibits a brighter tone and differences in geochemistry compared to Murray materials down-section [9,10]. CheMin XRD of most samples (except for HU and EB)showed large abundances of smectite clay minerals (~25-35%) and all samples showed X-ray amorphous materials and relatively low amounts of well-crystalline hematite[11]. SAM evaluated mineralogy through evolved gas analysis mass spectrometry (EGA) while detailed organic chemistry of several samples was examined by pyrolysis gas chromatography mass spectrometry and wet chemistry experiments [12,13].Here we discuss data and interpretations from SAM EGA analyses.

Mars↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

Volatile Organic Compounds Emitted from Air Fresheners: Plug-Ins at Home and Little Trees in Cars

Air fresheners contain volatile organic compounds (VOCs), some of which are possible hazardous air pollutants, carcinogens, or chemicals associated with adverse health effects such as asthma. This screening study identifies VOCs emitted from two types of air fresheners. Plug-in air fresheners are household products that release scents from a heated liquid. Little Tree air fresheners are commonly used solid devices designed to hang in from the rear view mirror in cars. VOCs that were released from heated samples of air fresheners were identified by gas chromatography mass spectroscopy (GCMS). Amongst VOCs commonly known to have scent properties, this screening also revealed the presence of compounds that are not associated with fragrances and that may have adverse health effects. In a pilot study to characterize how air fresheners affect air quality in real settings, air samples were collected on solid-phase microextraction (SPME) field samplers in a home setting and inside a vehicle, before and during air-freshener use. This pilot demonstrated some limited potential for SPME field samplers to track changes in VOC levels in real-life settings.

Adriana Pino-Delgado↗

Plasma Abatement of Volatile Organic Compounds for Treatment of Spacecraft Trash Combustion Gaseous Effluents.

One approach that has been investigated for trash management aboard long-duration crewed exploration space missions is the so-called Trash-to-Gas approach. This technology uses a thermal process (i.e., combustion, pyrolysis, etc.) to convert crew trash into relatively non-reactive gases (i.e., CO2, CO, etc.) that can be easily vented overboard. One difficulty with this approach is the potential for the contamination of the spacecraft habitable volume from the myriad volatile organic compounds (VOCs) that are concurrently produced from these thermal processes. One possible VOC abatement process is to apply a plasma to the effluent gases. Plasmas provide high energy electrons and ions that are capable of breaking down gaseous organic species generally into smaller compounds. To explore Plasma VOC abatement, the authors constructed a plasma gas system that recirculates a particular VOCladen gas mixture through a plasma torch. This allows the periodic collection of aliquots of gaseous samples for subsequent analyses via gas chromatography mass spectrometry, designed to quantify the remaining VOC materials. The VOCs evaluated included 100 ppm of acetone, benzene, ethanol, and pentane in a background of carbon dioxide. The plasma conversion of all analytes followed first order rate kinetics, and complete VOC elimination was observed after 10 min or less of treatment, for all analytes measured. Additionally, it was observed that the plasma caused the conversion of CO2 into oxygen and CO.

Joel A. Olson↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

The Non-Destructive Separation of Diverse Astrobiologically Relevant Organic Molecules By Customizable Capillary Zone Electrophoresis and Monolithic Capillary Electrochromatography

The in situ detection of organic molecules in space is key to understanding the variety and the distribution of the building blocks of life, and possibly the detection of extraterrestrial life itself. Gas chromatography mass spectrometry (GC-MS) has been the most sensitive analytical instrument for organic analyses in flight, and was used on missions from NASA’s Viking, Phoenix, Curiosity missions to ESA’s Rosetta space probe. While pyrolysis GC-MS revealed the first organics on Mars, this step alters or degrades certain fragile molecules that are excellent biosignatures including polypeptides, oligonucleotides and polysaccharides, rendering the intact precursors undetectable. We have identified a solution tailored to the detection of biopolymers and other biomarkers by the use of liquid-based capillary electrophoresis and electrochromatography. In this study, we show that a capillary electrochromatography (CEC) approach using monolithic stationary phases with tailor-made surface chemistry can separate and identify various polycyclic aromatic hydrocarbons (PAHs), nucleobases and aromatic acids that could be formed under astrophysically relevant conditions. In order to simulate flyby organic sample capture, we conducted hypervelocity impact experiments which consisted of accelerating peptide-soaked montmorillonite particles to a speed of 5.6 km/sec, and capturing them in an amorphous silica aerogel of 10 and 30 mg/cc bulk density. Bulk peptide extraction from aerogel followed by capillary zone electrophoresis led to the detection of only two stereoisomeric peptide peaks. The recovery rates of each step of the extraction procedure after the hypervelocity impact suggest that major peptide loss occurred during the impact. Our study provides initial exploration of feasibility of this approach for capturing intact peptides, and subsequently detecting candidate biomolecules during flight missions that would be missed by GC-MS alone. As the monolith-based electrochromatography technology could be customized to detect specific classes of compounds as well as miniaturized, these results demonstrate the potential of the instrumentation for future astrobiology-related spaceflight missions.

Flyby sample return↗

PAHs, Hydrocarbons, and Dimethylsulfides in Asteroid Ryugu Samples A0106 and C0107 and the Orgueil (CI1) Meteorite

Evaluating the molecular distribution of organic compounds in pristine extraterrestrial materials is cornerstone to understanding the abiotic synthesis of organics and allows us to better understand the molecular diversity available during the formation of our solar system and before the origins of life on Earth. In this work we identify multiple organic compounds in solvent extracts of asteroid Ryugu samples A0106 and C0107 and the Orgueil meteorite using two-dimensional gas chromatography and time-of-flight high resolution mass spectrometry (GC×GC-HRMS). Our analyses found similarities between the molecular distribution of organic compounds in Ryugu and the CI carbonaceous chondrite Orgueil. Specifically, several PAHs and organosulfides were found in Ryugu and Orgueil suggesting an interstellar and parent body origin for these compounds. We also evaluated the common relationship between Ryugu, Orgueil, and comets like Wild-2; however, until comprehensive compound-specific isotopic analyses for these organic species are undertaken, and until the effects of parent body processes and Earth’s weathering processes on meteoritic organics are better understood, their parent-daughter relationships will remain unanswered. Finally, the study of organic compounds in Ryugu samples and the curation practices for the future preservation of these unvaluable materials are also of special interest for future sample return missions, including NASA’s OSIRIS-REx asteroid sample return mission.

Hayabusa2↗

Plasma Abatement of Volatile Organic Compounds

One difficulty with crewed space operations is the potential for the contamination of the spacecraft habitable volume from volatile organic compounds (VOCs) that may be present. One possible VOC abatement process is to apply a plasma to the contaminated gases. Plasmas provide high energy electrons and ions that are capable of breaking down gaseous organic species generally into smaller compounds. To explore plasma VOC abatement, the authors constructed a plasma gas system that recirculates a particular VOC-laden gas mixture through a plasma torch. This allows for the periodic collection of aliquots of gaseous samples for subsequent analyses via gas chromatography mass spectrometry, designed to quantify the remaining VOC materials. The VOCs evaluated included 100 ppm of acetone, benzene, ethanol, and pentane in a background of carbon dioxide. The plasma conversion of all analytes followed first-order rate kinetics, and VOC elimination was observed after 10 min or less of treatment for all analytes measured. Additionally, it was observed that the plasma caused the conversion of CO 2 into oxygen and CO.

Joel A. Olson↗

2023 Cleanroom Monitoring for OSIRIS-REx

OSIRIS-REx is an asteroid sample return mission that delivered asteroid regolith from Bennu to Earth on 9/24/2023 [1]. Cleanroom monitoring of OSIRIS-REx Curation facilities has been ongoing since 2021 when construction of the OSIRIS-REx lab at Johnson Space Center (JSC) was completed [2]. The monitoring continues inside of the OSIRIS-REx lab in Houston. Monitoring was also conducted on a temporary cleanroom constructed inside a hangar at the Utah Test and Training Range (UTTR) to initially receive the Sample Return Capsule (SRC) upon its landing there. The following reports on cleanroom monitoring that has taken place in the months leading up to as well as after OSIRIS-REx return. Monitoring techniques used include particle counts, deployment of Si wafer witness plates (Balazs, Inc.) and Al foil witness plates, gas sampling (Balazs, Inc.) and microbiological monitoring. We collected particle counts at both the lab at JSC as well as the temporary cleanroom at UTTR. Particle counts were taken monthly from six locations in the lab at JSC. Particle counts were taken from seven locations at UTTR in July, August, and September. The UTTR cleanroom particle counts were taken daily in the five days leading to OSIRIS-REx return as well as consistently the day of return (every 2 minutes and 15 seconds 7:21 am- 6:27 pm) from one location inside the cleanroom. The particle counts at UTTR consistently stayed well within the ranges of its required ISO 7 equivalent classification (352,000 maximum particles/ m3 ≥ 0.5 μm). Most analysis showed that the particle counts were far below ISO 7 requirements (highest measured count was 61,484 particles/ m3 ≥ 0.5 um). but the elevated instances correlated to exterior hangar doors being open. Particle counts were reduced when keeping exterior hangar doors closed. The particle counts at JSC have stayed consistently within their ISO 5 equivalent classification (3,520 maximum particles/ m3 ≥ 0.5 um). In most instances, the counts are much better except in one instance where the count measured 13,381 particles/ m3 ≥ 0.5 um. The high spike in particle counts in the JSC lab correlated with the air handlers being shut down temporarily the previous day. The particle counts taken in the same location quickly reduced and measured 0 when taken a month later with the air handlers on. We deployed 8-inch semiconductor polished Si wafer witness plates for 24-hour periods inside of the OSIRIS-REx Curation lab at JSC (in July, August, September, and November 2023) and the cleanroom at UTTR (July and September 2023) to test for possible organic and inorganic contaminants. We also deployed these wafers inside of the OSIRIS-REx Touch-and-Go sample Acquisition Mechanism (TAGSAM) glovebox (where Bennu sample processing occurs) and desiccator (Bennu sample storage) at JSC in August 2023. These samples were all sent to Balazs for analysis via Thermal Desorption Gas Chromatography Mass Spectroscopy (TD-GC-MS) to quantify organic compounds and vapor phase decomposition inductively coupled plasma mass spectrometry (VPD-ICP-MS) to quantify inorganic contaminants. We collected air samples using an adsorbent tube connected to a pump for six hours (100 mL/minute) inside of both the JSC lab and the UTTR cleanroom. These samples were taken at JSC in July, August, September, November, and December and at UTTR in July and September. Additionally, a sample was taken just outside of the TAGSAM glovebox airlock door in July. These samples were sent to Balazs for analysis of volatile organics in air. Overall, the OSIRIS-REx lab at JSC and cleanroom at UTTR yielded very low organic and inorganic contaminants (similar results to Genesis lab at JSC which is ISO 4 equivalent) except for boron, which is attributed to the borosilicate glass in the fan filter units. We collected monthly surface and air samples inside the JSC lab to monitor potential microbial contamination. We report the recovery rate for each sampling event, which is defined as the number of samples exhibiting bacterial or fungal growth divided by the total number of samples collected. Since the lab was commissioned in 2021 the median recovery rate is 29%. This recovery rate is consistent with other ISO 5 equivalent labs used to curate astromaterials collections. Increases in recovery rate correspond to construction and/or extra activity in the lab. However, increases in recovery rate do not reliably correlate to increases in particle counts, which highlights the need for a dedicated microbial monitoring program for biologically sensitive collections. We sampled the temporary clean room at UTTR in July, August, and September of 2023 to monitor potential microbial contamination. The recovery rate decreased from 80% in August to 29% in September. However, in all instances, the diversity of bacteria and fungi was higher in the UTTR cleanroom than in the JSC lab. We routinely collected more than twenty different organisms from the UTTR cleanroom. In the JSC lab the median diversity is 2 organisms. Based on these results we hypothesize that microbes from UTTR could be transported back to JSC with the Bennu samples. To mitigate this risk, in September of 2023, we implemented additional cleaning procedures in the JSC lab to reduce the bioburden on surfaces that could come into direct contact with hardware used to process Bennu samples. Since adopting these additional cleaning measures, the median recovery rate has decreased to 14%. We did not observe an increase in fungal or bacterial diversity in the lab in the October sampling. We will continue to monitor this trend closely for the next several months. Supported by NASA under Award NNH09ZDA007O and Contract NNM10AA11C.

Rachel Comstock Funk↗

Developmental Hardware Testing Results and Forward Plans for the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Xplo-SA9T: Optimization of Sorbent Technology With Existing and New Amine Variants for Carbon Dioxide Removal and Humidity Control

Scrubbing of the spacesuit air stream to control humidity and regulate carbon dioxide (CO 2 ) relies on amine-loaded resins, colloquially known as sorbents. The efficacy of Rapid Cycle Amine technology relies on the propensity of nitrogens toward adsorption of CO 2 while simultaneously offering regenerative properties under vacuum or positive pressure. The commonly utilized sorbent, SA9T, was recreated and evaluated further to increase stability and serve as a benchmark comparison for newly synthesized amine sorbent technologies. Ongoing storage studies with eight different environments will allow the development of applicable storage protocols and provide insight into possible ammonia generation pathways. Attempts to alleviate the known issues with SA9T included the alteration of the primary amine (tetraethylenepentamine), the choice of resin, and the particle size distribution. In-house CO 2 breakthrough experiments were conducted using a specialized apparatus that can simulate spacesuit conditions, offering high-quality triplicate capacity analysis affording direct comparison to known adsorbents in the literature. Thermo-Desorption Gas Chromatography Mass Spectrometry studies on the synthesized materials revealed any reagent or solvent offgassing while Nuclear Magnetic Resonance spectroscopy tracked the stability of the bound amine. Scanning Electron Microscope images of sieved materials provided a more accurate size interpretation facilitating synthetic design and pressure drop elimination. All efficient sorbents were synthesized to a commercial batch scale subsequent to evaluation including Xplo-SA9T.

John R Tidwell↗

Investigating Commercial Off-The-Shelf (COTS) Glovebox and Support Components Compared to Custom Curatorial Laboratories

There is a need envisioned to investigate the application of commercial off-the-shelf (COTS) systems as tools that could be used within commercial preliminary curation as the expected space economy is supported and begins to take flight. NASA is involved with supporting and developing the space economy [1] and therefore it’s feasible that at some point, a commercial space company would bring back materials and either store initially, or permanently, within COTS equipment as a stand-in for custom curation laboratories. While utilizing opportunities to explore this capability at NASA-Johnson Space Center (JSC) during the establishment of other laboratories [2] it was realized that cleanliness and/or other properties could be evaluated for these COTS systems during their installation in advanced research facilities that are not ISO-class rated clean rooms. Several aspects of a COTS-Curation system were explored including various gloves for curation manipulation within a negative pressure glovebox (Fig.1), Balazs organic and inorganic contaminant levels testing prior to glovebox ever being used, mode swapping comparison of recirculation vs. single pass, constant monitoring of oxygen (O2) and moisture (H2O) levels in various conditions, etc. To acquire inorganic and organic compound loads inside the glovebox, Balazs wafer testing and gas sampling were implemented. These are standardized analytical tests provided by Balazs™ NanoAnalysis, a division of Air Liquide USA. Deployment of 8-inch silicon wafer witness plates for 24-hours in an undisturbed environment capture the organic compound load and inorganic trace metal contents which can be obtained by Vapor Phase Decomposition Inductively Coupled Plasma Mass Spectrometry (VPD ICP-MS). Balazs gas sample analysis was also performed for better measurements of volatile organic compounds (VOC) in glovebox air analyzed by Thermal Desorption Gas Chromatography Mass Spectrometry (TD GC-MS). These analytical testings were carried out in a controlled ultra high pure (UHP) gaseous nitrogen (N2)-purged environment where oxygen and moisture contents were continuously monitored at certain temperature and pressure. The preliminary outcomes of these testings are promising. The COTS systems appear to maintain the steady-state controlled environment for days, if not weeks, with uninterrupted gaseous N2-supply which was operated from a standard medium pressure LN2 250L 230L dewar, exchanged as needed. The outgassing load can be maintained by selecting the glove materials that have the least outgassing and particle shedding performances. Further experiments will be considered to validate the preliminary findings. While this project is exploratory, it is not intended as an endorsement by NASA Curation for approved materials or usage for advanced curatorial activities. NASA does not endorse nor promote any one particular product or company. References: [1] McCubbin F. M. et al. (2019) Space Science Reviews 215:A48. [2] Lewis, E.K. et. al (2024) LPSC LV, Abstract #2457.

Curation↗

Developmental Hardware Testing Results and Forward Plans for Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Organic Products of Fatty Acid and Magnesium Sulfate Mixtures after Gamma Radiolysis: Implications for Missions to Europa

If ocean-derived materials are present at Europa’s surface, they would represent accessible records of ocean chemistry and habitability, but such materials would be further processed by the moon’s harsh radiation environment. In this study, saturated fatty acids were precipitated onto a Europa-relevant hydrated magnesium sulfate and exposed to gamma radiation doses up to 2 MGy at -196° C. Alkane chains, with carbon numbers one less than those of the starting fatty acids, were the most abundant radiolysis products in solvent and thermal extracts analyzed by gas chromatography mass spectrometry. Detections of monounsaturated fatty acids and combined radiolysis products were attributed to the experiment’s Europa-like parameters. Additionally, elevated concentrations of shorter-chain saturated fatty acids suggest that gamma radiation induced charge remote fragmentation of the alkyl chains of some starting fatty acids under these experimental conditions. Quantitation of fatty acid concentrations in the irradiated samples enabled the calculation of a radiolysis constant that indicated exposure to a 5 MGy dose of gamma radiation would have resulted in a ~90% loss of the initial fatty acid population. The samples were further studied by Raman spectroscopy and laser desorption and ionization mass spectrometry, which characterized the distribution of fatty acids and their radiolysis products on sulfate surfaces. The substantial loss of starting fatty acids typically seen with increasing radiation dose, along with the remarkable diversity of radiolysis products identified, suggest that the detection of fatty acids in irradiated sulfate deposits on Europa will be challenged by rapid destruction of any initial fatty acid populations and scrambling of their residual signals by a myriad of organic radiolysis products. If missions to Europa encounter sulfate deposits, targeting minimally irradiated units may still enable the detection of surviving fatty acid signatures that could inform about Europa’s subsurface chemistry and habitability.

James M T Lewis↗

Apollo Botany Experiments and Artemis: Discussion of Botany Experiment Records Digitized as Part of the Apollo Records Synthesis Project (ARSP)

The Artemis Program, with its objective of establishing a sustained human presence on the moon, has rekindled interest in lunar botany as an area of inquiry. Limited availability of collected lunar regolith samples for plant growth experiments underlines the need to leverage all existing historic datasets. As part of NASA’s Life Sciences Data Archive’s (LSDA) Apollo Records Synthesis Project (ARSP), a collection of historic Apollo era botany experiment research records from the former Space Life Sciences Archival Library (SLSAL) collection, these records have been digitized to improve access for data reuse. The records are related to post-mission quarantine experiments conducted to characterize any pathogenic effects of lunar regolith on exposed plant specimens and includes several possible dataset sources such as microscopy photos, laboratory notebooks, correspondence, data sheets, and gas chromatography results. This collection includes the output of investigations of taxa previously under-investigated in the context of space biology. An unusually phylogenetically diverse group of plants are represented in this dataset (including Pinaceae, Poeaceae, Solanaceae, Apiaceae and more). This presentation will discuss the contents of the collection, their historic context, the digitization of the collection, and the opportunities they may provide when placed in the larger corpus of lunar botany regolith experiments.

Archives↗

Molecular Inventory and Comparative Organic Profiling of A Homogenized Aggregate Sample From Asteroid (101955) Bennu

Evaluating the distribution and diversity of solvent-soluble organic molecules in extraterrestrial materials provide information about the physicochemical environments where prebiotic chemistry occurred and is essential for assessing the inventory of prebiotic compounds available to the early Earth. In this work, we conducted a comprehensive molecular characterization of solvent-soluble organic compounds in a homogenized aggregate sample (ID: OREX-800107-128) of unsorted regolith from asteroid (101955) Bennu returned by NASA’s OSIRIS-REx mission. Using two-dimensional gas chromatography coupled with high-resolution time-of-flight mass spectrometry (GC×GC-HRMS), we identified 87 organic compounds across several molecular classes, including alkanes, polycyclic aromatic hydrocarbons, and nitrogen-, oxygen-, and sulfur-bearing species. Comparison with the organic inventory of CI (Orgueil), C2-ungrouped (Tagish Lake and Tarda), and CM2 (Murchison) carbonaceous chondrites revealed that Bennu sample OREX-800107-128 is most similar to Tagish Lake and Tarda yet compositionally distinct from all of these meteorites. This Bennu sample exhibits a relatively high abundance of low-molecular-weight aromatics (e.g., toluene), pyridine derivatives, and sulfur species such as dimethyl sulfite, consistent with episodic low-temperature aqueous alteration. The presence of these organic compounds suggests that this material experienced chemically diverse processes in the parent body conducive to complex organic synthesis, including aldol condensation reactions responsible for N- and O-bearing compounds. We also compared the molecular distributions of this Bennu sample and previously analyzed samples from (162173) Ryugu to assess potential common origins between these two carbonaceous asteroids. Bennu shows more chemically diverse and nitrogen-rich organic materials than Ryugu. While both asteroids share broadly similar primitive compositions, the observed chemical differences indicate distinct evolutionary histories within a likely common formation environment though whether Bennu and Ryugu derive from a single compositionally heterogeneous parent body or from multiple closely related progenitors remains unresolved. Further detailed comparative analyses of material from Bennu, Ryugu, and specific carbonaceous meteorites (e.g., Tagish Lake and Tarda) will provide new insights into how the N-rich molecular profile observed in Bennu samples was formed and evolved in the outer Solar System.

sample return↗

Polymeric media comprising polybenzimidazoles N-substituted with organic-inorganic hybrid moiety

A PBI compound includes imidazole nitrogens at least a portion of which are substituted with an organic-inorganic hybrid moiety may be included in a separator medium. At least 85% of the imidazole nitrogens may be substituted. The organic-inorganic hybrid moiety may be an organosilane moiety, for example, (R)Me.sub.2SiCH.sub.2-- where R is selected from among methyl, phenyl, vinyl, and allyl. The separatory medium may exhibit an H.sub.2, Ar, N.sub.2, O.sub.2, CH.sub.3, or CO.sub.2 gas permeability greater than the gas permeability of a comparable separatory medium comprising the PBI compound without substitution. The separatory medium may further include an electronically conductive medium and/or ionically conductive medium. The separatory medium may be used as a membrane (semi-permeable, permeable, and non-permeable), a barrier, an ion exhcange media, a filter, a gas chromatography coating (such as stationary phase coating in affinity chromatography), etc.

36 MATERIALS SCIENCE↗

Electrochemistry of LiCl-Li2O-H2O Molten Salt Systems

Uranium can be recovered from uranium oxide (UO2) spent fuel through the combination of the oxide reduction and electrorefining processes. During oxide reduction, the spent fuel is introduced to molten LiCl-Li2O salt at 650 degrees C and the UO2 is reduced to uranium metal via two routes: (1) electrochemically, and (2) chemically by lithium metal (Li0) that is produced electrochemically. However, the hygroscopic nature of both LiCl and Li2O leads to the formation of LiOH, contributing hydroxyl anions (OH-), the reduction of which interferes with the Li0 generation required for the chemical reduction of UO2. In order for the oxide reduction process to be an effective method for the treatment of uranium oxide fuel, the role of moisture in the LiCl-Li2O system must be understood. The behavior of moisture in the LiCl-Li2O molten salt system was studied using cyclic voltammetry, chronopotentiometry and chronoamperometry, while reduction to hydrogen was confirmed with gas chromatography.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗