Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Pushing Green: Leveraging Home Energy Score to Promote Deep-Energy Retrofits in Portland, Oregon

In the United States, 39% of total energy is consumed by the building sector, 20% of which is attributed to residential buildings. Older homes, built before 1992 when the U.S. Department of Energy’s (DOE) Building Energy Codes Program was established, represent approximately 68% of residential building stock in the country and often have significant air leakage, inadequate insulation and inefficient heating & cooling systems. These older homes have long been the elephant in the room: how can programs effectively increase efficiency in all of the homes in need? Developed by DOE, the Home Energy Score was established to provide homeowners, buyers, and renters a comparable score measuring a home's energy use. Much like the MPG rating of automobiles, the Home Energy Score provides an overview of a residential building’s energy efficiency. In 2016, the City of Portland passed an ordinance requiring all residential properties to receive a Home Energy Score before being listed for sale, a mandate that was implemented January 1, 2018. Since 2018, more than 22,000 homes throughout the Portland Metro area have received Home Energy Scores (amounting to over 10% of Portland's single-family homes). This paper explores the sample of Home Energy Scores throughout Portland, including at the neighborhood level, identifies trends in efficiency measures, describes how the data has been used to date and proposes ways program administrators can use the Home Energy Score to increase the impact of energy efficiency programs on a city-scale.

Antonopoulos, Chrissi A.↗

Modeling Thermal Interactions between Buildings in an Urban Context

Thermal interactions through longwave radiation exchange between buildings, especially in a dense urban environment, can strongly influence a building’s energy use and environmental impact. However, these interactions are either neglected or oversimplified in urban building energy modeling. We developed a new feature in EnergyPlus to explicitly consider this term in the surface heat balance calculations and developed an algorithm to batch calculating the surrounding surfaces’ view factors using a ray-tracing technique. We conducted a case study with a district in the Chicago downtown area to evaluate the longwave radiant heat exchange effects between urban buildings. Results show that the impact of the longwave radiant effects on annual energy use ranges from 0.1% to 3.3% increase for cooling and 0.3% to 3.6% decrease for heating, varying among individual buildings. At the district level, the total energy demand increases by 1.39% for cooling and decreases 0.45% for heating. We also observe the longwave radiation can increase the exterior surface temperature by up to 10 °C for certain exterior surfaces. These findings justify a detailed and accurate way to consider the thermal interactions between buildings in an urban context to inform urban planning and design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Urban Surface Radiative Energy Budgets Determined Using Aircraft Scanner Data

It is estimated that by the year 2025, 80% of the world's population will live in cities. The extent of these urban areas across the world can be seen in an image of city lights from the Defense Meteorological Satellite Program. In many areas of North America and Europe, it is difficult to separate individual cities because of the dramatic growth and sprawl of urbanized areas. This conversion of the natural landscape vegetation into man-made urban structures such as roads and buildings drastically alter the regional surface energy budgets, hydrology, precipitation patterns, and meteorology. One of the earliest recognized and measured phenomena of urbanization is the urban heat island (UHI) which was reported as early as 1833 for London and 1862 for Paris. The urban heat island results from the energy that is absorbed by man-made materials during the day and is released at night resulting in the heating of the air within the urban area. The magnitude of the air temperature difference between the urban and surrounding countryside is highly dependent on the structure of the urban area, amount of solar immolation received during the day, and atmospheric conditions during the night. These night time air temperature differences can be in the range of 2 to 5 C. or greater. Although day time air temperature differences between urban areas and the countryside exists during the day, atmospheric mixing and stability reduce the magnitude. This phenomena is not limited to large urban areas, but also occurs in smaller metropolitan areas. The UHI has significant impacts on the urban air quality, meteorology, energy use, and human health. The UPI can be mitigated through increasing the amount of vegetation and modification of urban surfaces using high albedo materials for roofs and paved surfaces. To understand why the urban heat island phenomenon exists it is useful to define the surface in terms of the surface energy budget. Surface temperature and albedo is a major component of the surface energy budget. Knowledge of it is important in any attempt to describe the radiative and mass fluxes which occur at the surface. Use of energy terms in modeling surface energy budgets allows the direct comparison of various land surfaces encountered in a urban landscape, from vegetated (forest and herbaceous) to non-vegetated (bare soil, roads, and buildings). These terms are also easily measured using remote sensing from aircraft or satellite platforms allowing one to examine the spacial variability. The partitioning of energy budget terms depends on the surface type. In natural landscapes, the partitioning is dependent on canopy biomass, leaf area index, aerodynamic roughness, and moisture status, all of which are influenced by the development stage of the ecosystem. In urban landscapes, coverage by man-made materials substantially alters the surface face energy budget. The remotely sensed data obtained from aircraft and satellites, when properly calibrated allows the measurement of important terms in the radiative surface energy budget a urban landscape scale.

Luvall, Jeffrey C.↗

Whole-building life-cycle analysis with a new GREET® tool: Embodied greenhouse gas emissions and payback period of a LEED-Certified library

Embodied greenhouse gas (GHG) emissions of building components and buildings operations need to be quantified to holistically address building sustainability. To evaluate embodied GHG emissions of buildings and to provide insights on building materials and building design decisions toward decarbonization, we have recently created a building life-cycle assessment (LCA) module in the widely used Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET (R)) LCA model. We applied the GREET building LCA module to examine embodied GHG impacts and the payback period of a LEED (Leadership in Energy and Environmental Design) certified public library in Chicago, USA. We developed localized, detailed life-cycle inventories to address individual building materials used in the library. We expanded the LCA system boundary to include the mechanical, electrical, and plumbing system, as well as refrigerant impacts, which are often ignored in previous studies. Results show that the total embodied GHG emissions are approximately 817 metric tons, or approximately 538 kg/m 2 . Sensitivity analysis highlights the positive role of increasing the use of recycled materials for reducing embodied GHG emissions. Sensitivity analysis on embodied GHG emissions payback periods shows the need to benchmark the embodied and operational carbon performance of buildings for comparison to alternative building designs and sustainability practices. Furthermore, this analysis demonstrates that building LCA models, such as the GREET building LCA module, which addresses embodied and operational GHG emission impacts of whole buildings holistically, could empower building architects, technology developers, manufacturers, and general contractors to address embodied and operational impacts holistically for building sustainability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Nuclear Energy to Support Economy-wide Net-zero Solutions: Challenges and Opportunities

Governments and private industry around the world have established aggressive goals to achieve net-zero emissions for the power, industrial, and transportation sectors by 2050. These aggressive goals demand immediate action if we are to be successful, and they require us to think more holistically about our clean energy options. Programs within the U.S. Department of Energy (DOE) are addressing these holistic solutions. Traditionally, electricity generation and management and meeting energy demands for industry and transportation are considered independently. As we seek to achieve net-zero, we need to reassess energy demands. When we consider overall energy use, only one-third is in the form of electricity. Additional energy demands are in the form of heat or steam for industrial processes, as well as transportation. These sectors are much harder to abate, and electrification may not be the best option. Reducing environmental emissions at an affordable cost, while maintaining grid reliability and resilience, will require us to use all of the clean energy resources that we have available. That means coordinating the use of nuclear, renewables, and fossil fuels with carbon capture to meet growing demands for electricity, industrial applications, and mobility. The DOE Office of Nuclear Energy (DOE-NE) program on Integrated Energy Systems (IES) is led by researchers at Idaho National Laboratory (INL) and work is conducted in partnership with an array of other DOE laboratories, industry, and academia. The primary focus of IES research is to assess the technical and economic potential of IES to enhance the flexibility and utilization of nuclear reactors working alongside renewable generators to meet an array of energy demands—thereby maximizing the utilization of clean energy resources across all energy sectors. Various energy applications and product streams beyond electricity are being evaluated, ranging from generation of potable water to production of hydrogen, fertilizers, synthetic fuels, and chemicals. The DOE-NE program additionally partners with the Hydrogen and Fuel Cell Technologies Office under the DOE Office of Energy Efficiency and Renewable Energy to jointly fund the development of analysis tools, technologies, and nuclear-integrated hydrogen demonstration projects. This presentation highlights the wide array of R&D being conducted across multiple DOE-funded programs to develop and deploy nuclear-based IES that will be key to achieving our net-zero goals. By working with key collaborators in the nuclear industry, analytical studies are now becoming a reality in demonstration projects. The presentation specifically focuses on motivations for the paradigm shift in how nuclear energy is deployed and used, opportunities for nuclear energy to support an array of non-electric application, integration options, computational tools and experimental systems to support evaluation and to accelerate deployment, and industry partnerships.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exploring the Potential of ASHRAE Guideline 36 in District Cooling Systems: Preprint

ASHRAE Guideline 36-2021 (G36) provides high-performance control sequences for all-air and hydronic HVAC systems, and it has proven effective at reducing energy use for single building all-air equipment. The most recent version of G36 included control sequences for water-cooled chiller plants, which can be used in district cooling systems (DCSs). Despite not being a traditional application of G36 controls, DCSs could benefit from energy savings that G36 control sequences have demonstrated in single building systems. We therefore investigate the possibility to extend G36 chiller plant control from a single building to district cooling using a real-world district cooling system in Boulder, Colorado as a case study. Four timeframes representing low to peak loads are simulated and analyzed to compare energy use of the district cooling system for three control sequences. Results show that although G36 chiller plant sequences can be applied to DCSs, further analysis and potentially control optimization is needed to ensure energy savings compared to default controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Exchanger Design for Waste Heat Recovery using Additive Manufacturing

With anticipated increases in global energy use and their associated emissions, there are many efforts to improve the emissions and efficiency of many industrial processes through waste heat recovery (WHR). To maximize improvements, the heat exchangers in WHR power cycles must be designed and optimized for a given heat source. Meanwhile, additive manufacturing (AM) is a single part manufacturing technique that provides the opportunity to develop unique and complex heat exchanger designs. Consequently, this work centers on the modeling, design, optimization, and testing of AM shell and tube heat exchangers for WHR. Specifically, a modified one-dimensional (1+1-D) and three-dimensional (3-D) heat exchanger models were developed and validated, with the 1+1-D model serving as the basis for design optimization. After modifications to the design to allow for AM, heat exchanger geometry optimizations were completed, targeting increased effectiveness across a range of physical parameters. Of the designs considered, nine were additively manufactured using Ti5553, and then tested using an external heat source and working fluid. Experimentally, the nineteen-tube, zero-baffle heat exchanger displayed the best overall performance, with the effects of dimensional accuracy, surface roughness, and baffles in the other designs also indicated. Next, the experimental results were used as inputs for the 1+1-D model. Although the original model was able to predict fluid outlet temperatures within 5% differences, larger variations in the heat exchanger performance parameters, temperature differences, and pressure drop necessitated optimizing the pressure drop and heat transfer calculations within the model. Thus, the resulting improved model was able to predict the heat transfer rates, heat source temperature difference, and effectiveness within 15% differences, while showing improvements in the pressure drops and working fluid temperature differences. The improved model serves as the foundation for future work to improve the design and performance of AM heat exchangers.

Spickler, Bailey Ann↗

Novel PCM-based fin and tube heat exchanger system for building heating and cooling applications

In the United States, the building sector accounts for 40% of all energy use, and buildings are responsible for more than two-thirds of electricity consumption. Buildings remain the major driver of energy-related carbon emissions, and such emissions are projected to increase in the years ahead because of urbanization and population growth. To accomplish the low carbon energy goal in the building sector, phase change material (PCM)–based thermal energy storage (TES) is increasingly being adopted because it offers several advantages, such as reducing building peak load and energy consumption, enabling large scale deployment of renewables, and improving grid stability. The integration of TES with thermally anisotropic building envelopes (TABEs) is a promising solution because, TABE can redirect natural thermal energy from a building using hydronic loops to TES, and the stored energy can be used later for heating and cooling applications. In this study, we experimentally investigate the thermal performance of a novel fin-tube heat exchanger TES system designed for potential integration with a TABE. An experimental rig for a 5-gal PCM fin-tube heat exchanger system with water as the heat transfer medium is described which records temperatures at the heated and cooled boundaries of the system. Experimental observations provide insight into the role a TES system can play in offsetting a building’s heating and cooling demand and also offer a means to characterize the performance of PCMs for building applications. The scale and study presented in this work will help in the design of future thermal storage systems optimized for storage capacity while also accounting for overall system costs for building applications.

Tamraparni, Achutha↗

ComStock Reference Documentation (V.1)

The commercial building sector stock model, or ComStock™, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. ComStock asks and answers two questions: how is energy used in the U.S. building stock and what are the impact of energy saving technologies. Specifically, ComStock identifies where energy is being consumed geographically, in what building types and end uses, and at what times of day. Simultaneously, it identifies the impact of efficiency measures: how much energy do efficiency measures save; where, or in what use cases do measures save energy; when, or at what time of day do savings occur; and which building stock segments have the biggest savings potential. This document contains the methodology and assumptions behind ComStock and serves as a guide to its use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Fully-Compressible Equation Sets for Atmospheric Dynamics

Traditionally, the equation for the conservation of energy used in atmospheric models is based on potential temperature and is used in place of the total energy conservation. This paper compares the application of the two equations sets for both the Euler and the Navier-Stokes solutions using several benchmark test cases. A high-resolution wave-propagation method which accurately takes into account the source term due to gravity is used for computing the non-hydrostatic atmospheric flows. It is demonstrated that there is little to no difference between the results obtained using the two different equation sets for Euler as well as Navier-Stokes solutions.

Ahmad, Nashat N.↗

Accurate collision-induced line-coupling parameters for the fundamental band of CO in He - Close coupling and coupled states scattering calculations

The first accurate theoretical values for off-diagonal (i.e., line-coupling) pressure-broadening cross sections are presented. Calculations were done for CO perturbed by He at thermal collision energies using an accurate ab initio potential energy surface. Converged close coupling, i.e., numerically exact values, were obtained for coupling to the R(0) and R(2) lines. These were used to test the coupled states (CS) and infinite order sudden (IOS) approximate scattering methods. CS was found to be of quantitative accuracy (a few percent) and has been used to obtain coupling values for lines to R(10). IOS values are less accurate, but, owing to their simplicity, may nonetheless prove useful as has been recently demonstrated.

Green, Sheldon↗

Federal Energy Management 101: Track 7, Session 1

Federal Energy Management 101: What are common building systems that use energy? This session will cover the basics of HVAC, Lighting, and Building Envelope and discuss how much energy each system tends to use within facilities - and how that changes across building types. Additionally, this session will cover identifying energy conservation measures (ECMs) and the process in which they are identified, funded, implemented, and savings are verified.

101↗

Assessing solar energy and water use efficiencies in winter wheat

The water use and solar energy conversion efficiencies of two cultivars of winter wheat (Triticum aestivum L., vars, Centurk and Newton) planted at three densities, were examined during a growing season. Water use, based on soil moisture depletion, was the lowest under the light, and the highest under the heavy planting densities of both cultivars. Water use efficiency of medium and heavy planting densities were greater than the light planting densities in both cultivars. The canopy radiation extinction coefficients of both cultivars increased with increases in planting density. Efficiency of operation interception of photosynthetically active radiation by both cultivars improved from the time of jointing until anthesis, and then decreased during senescence. The efficiency of the conversion of intercepted radiation to dry matter (biochemical efficiency) decreased throughout the growing season both cultivars. The interception, biochemical, and photosynthetic efficiencies improved as planting density increased.

Asrar, G.↗

Impact of ceiling fan and room air cleaner on air mixing and fate of particulate matter in a multiroom residence

We are exposed to airborne particles of health concern in residences, and Room Air Cleaners (RACs) can remove these particles. However, they are often limited to treating local air in the room or near vicinity of the device. RAC performance in multi-room residences may be improved by ceiling fan whole-house air mixing with a minor increase in energy use. Here, this study analyzed air quality and energy efficiency from experimental measurements using combinations of ceiling fan and RAC operation. We measured removal rates of tracer gas and particles from ultrafine to 5 µm after their release in the kitchen area of a multiroom test house. Results show that the air mixing by ceiling fans increased ultrafine and > 1 µm particle removal over the baseline – with no ceiling fans and no RAC – suggesting increased deposition onto the ceiling fan blades and house surfaces. Also, ceiling fan mixing increased particle removal in all size bins over the RAC performance with no ceiling fans. The removal rate with ceiling fans and the RAC was greater than the sum of the rates from each operating alone, indicating that synergistic interactions between the ceiling fans and the RAC increased the RAC filtration rate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗