Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electronic Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Invited Article: An integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument

We report on the development of the first integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument, covering an ultra wide spectral range from 3 cm{sup −1} to 7000 cm{sup −1} (0.1–210 THz or 0.4–870 meV). The instrument comprises four sub-systems, where the magneto-cryostat-transfer sub-system enables the usage of the magneto-cryostat sub-system with the mid-infrared ellipsometer sub-system, and the far-infrared/terahertz ellipsometer sub-system. Both ellipsometer sub-systems can be used as variable angle-of-incidence spectroscopic ellipsometers in reflection or transmission mode, and are equipped with multiple light sources and detectors. The ellipsometer sub-systems are operated in polarizer-sample-rotating-analyzer configuration granting access to the upper left 3 × 3 block of the normalized 4 × 4 Mueller matrix. The closed cycle magneto-cryostat sub-system provides sample temperatures between room temperature and 1.4 K and magnetic fields up to 8 T, enabling the detection of transverse and longitudinal magnetic field-induced birefringence. We discuss theoretical background and practical realization of the integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument, as well as acquisition of optical Hall effect data and the corresponding model analysis procedures. Exemplarily, epitaxial graphene grown on 6H-SiC, a tellurium doped bulk GaAs sample and an AlGaN/GaN high electron mobility transistor structure are investigated. The selected experimental datasets display the full spectral, magnetic field and temperature range of the instrument and demonstrate data analysis strategies. Effects from free charge carriers in two dimensional confinement and in a volume material, as well as quantum mechanical effects (inter-Landau-level transitions) are observed and discussed exemplarily.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlative Magnetic Imaging of Heat-Assisted Magnetic Recording Media in Cross Section Using Lorentz TEM and MFM

In order to increase the storage density of hard disk drives, a detailed understanding of the magnetic structure of the granular magnetic layer is essential. Here, we demonstrate an experimental procedure of imaging recorded bits on heat-assisted magnetic recording (HAMR) media in cross section using Lorentz transmission electron microscopy (TEM). With magnetic force microscopy and focused ion beam (FIB), we successfully targeted a single track to prepare cross-sectional TEM specimens. Then, we characterized the magnetic structure of bits with their precise location and orientation using Fresnel mode of Lorentz TEM. Here, this method can promote understanding of the correlation between bits and their material structure in HAMR media to design better the magnetic layer.

36 MATERIALS SCIENCE↗

Results from 2010 Caliban Criticality Dosimetry Intercomparison

The external dosimetry program participated in a criticality dosimetry intercomparison conducted at the Caliban facility in Valduc, France in 2010. Representatives from the dosimetry and instrumentation groups were present during testing which included irradiations of whole-body beta/gamma (HBGT) and neutron thermoluminescent dosimeters (TLDs), a fixed nuclear accident dosimeter (FNAD), electronic alarming dosimeters, and a humanoid phantom filled with reference man concentrations of sodium. This report reviews the testing procedures, preparations, irradiations, and presents results of the tests.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic control assembly qualification model

Fabrication and testing of the magnetic control assembly (MCA) are summarized. The MCA was designed as an add-on unit for certain existing components of the Nimbus and ERTS attitude control system. The MCA system consists of three orthogonal electromagnets; a magnetometer probe capable of sensing external fields in the X, Y, and Z axes; and the control electronics. An operational description of the system is given along with all major drawings and photographs. Manufacturing and inspection procedures are outlined and a chronological list of events is included with the fabrication summary.

Shen, R. C.↗

A catalogue of solar cosmic ray events: IMPS 4 and 5, May 1967 - December 1972

This catalogue of solar cosmic ray events has been prepared for the use of solar physicists and other interested scientists. It contains some 185 solar particle events detected by the Goddard Space Flight Center Cosmic Ray Experiments on IMP's IV and V (Explorer 34 and 41) for the period May 1967 - December 1972. The data is presented in the form of hourly averages for three proton energy intervals - 0.9 - 1.6 MeV; 6 - 20 MeV and 20 - 80 MeV. In addition the time histories of .5 - 1.1 MeV electrons are shown on a separate scale. To assist in the identification of related solar events, the onset time of the electron event is indicated. The details of the instrumentation and detector techniques are described. Further descriptions of data reduction procedure and on the time-history plots are given.

Vanhollebeke, M. A.↗

Reliability analysis

The objective was to search for and demonstrate approaches and concepts for fast wafer probe tests of mechanisms affecting the reliability of MOS technology and, based on these, develop and optimize test chips and test procedures. Progress is reported on four important wafer-level reliability problems: gate-oxide radiation hardness; hot-electron effects; time-dependence dielectric breakdown; and electromigration.

Source record↗

Improvement of critical current density in thallium-based (Tl,Bi)Sr(1.6)Ba(0.4)Ca2Cu3O(x) superconductors

Epitaxial (Tl,Bi)Sr(1.6)Ba(0.4)Ca2Cu3O(x) ((Tl,Bi)-1223) thin films on (100) single crystal LaAlO3 substrates were synthesized by a two-step procedure. Phase development, microstructure, and relationships between film and substrate were studied by X-ray diffraction (XRD), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). Resistance versus temperature, zero-field-cooled and field cooled magnetization, and transport critical current density (J(sub c)) were measured. The zero-resistance temperature was 105-111 K. J(sub c) at 77 K and zero field was greater than 2 x 10(exp 6) A/sq cm. The films exhibited good flux pinning properties.

Ren, Z. F.↗

Radiation Doses to Operators in Hepatobiliary Interventional Procedures

PurposeThe primary aim of this study is to provide a summary of operators’ radiation doses during hepatobiliary fluoroscopic guided procedures. In addition, patient dose in these procedures was also documented.Materials and MethodsA total of 283 transarterial chemoembolisation (TACE) and 302 biliary procedures, including 52 percutaneous transhepatic cholangiogram (PTC), 36 bilioplasty and 214 biliary catheter changes (BCC) performed over 14 months, were included. Electronic personal dosimeters were used to measure operator radiation doses. Effective dose (E) was calculated using modified Niklason algorithm. Patient dose was measured as dose area product (DAP) and fluoroscopy time (FT).ResultsFor TACE, E for radiologist ranged between 0 and 9.96 µSv, for radiographer 0–0.99 µSv and for nurse 0–4.65 µSv. The patient DAP and FT ranged between 1.5 and 421.9 Gy cm{sup 2} and 1.91–67.25 min. For PTC, E for the radiologist ranged between 0.33 and 55.89 µSv, for radiographer 0–38.61 µSv and for nurse 0–3.18 µSv. Patient DAP and FT ranged between 1.7 and 218.4 Gy cm{sup 2} and 2.07–71.53 min. For bilioplasty, E ranged between 0.09 and 9.24 µSv for radiologist, 0–0.84 µSv for radiographer and 0–1.38 µSv for nurse. The patients’ DAP and FT ranged from 0.7 to 52.54 Gy cm{sup 2} and 1.13–24.47 min. For BCC, E ranged from 0 to 12.78 µSv for radiologist, 0–8.43 µSv for radiographer and 0–4.05 µSv for nurse. Patient DAP and FT ranged between 0.12 and 117.3 Gy cm{sup 2} and 0.57–15.83 min.ConclusionsThis study shows that doses to all operators performing hepatobiliary interventional procedures can be very low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing chirped laser pulse parameters for electron acceleration in vacuum

Electron dynamics in the field of a chirped linearly polarized laser pulse is investigated. Variations of electron energy gain versus chirp parameter, time duration, and initial phase of laser pulse are studied. Based on maximizing laser pulse asymmetry, a numerical optimization procedure is presented, which leads to the elimination of rapid fluctuations of gain versus the chirp parameter. Instead, a smooth variation is observed that considerably reduces the accuracy required for experimentally adjusting the chirp parameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel nuclear pyrometry for the characterization of high-energy bremsstrahlung and electrons produced in relativistic laser-plasma interactions

We present a novel nuclear activation-based method for the investigation of high-energy bremsstrahlung produced by electrons above 7 MeV generated by a high-power laser. The main component is a novel high-density activation target that is a pseudo alloy of several selected isotopes with different photo-disintegration reaction thresholds. The gamma spectrum emitted by the activated targets is used for the reconstruction of the bremsstrahlung spectrum using an analysis method based on Penfold and Leiss. This nuclear activation-based technique allows for the determination of the number of bremsstrahlung photons per energy bin in a wide range energy without any anticipated fit procedures. Furthermore, the analysis method also allows for the determination of the absolute yield, the energy distribution, and the temperature of high-energy electrons at the relativistic laser-plasma interaction region. The pyrometry is sensitive to energies above 7 MeV only, i.e., this diagnostic is insensitive to any low-energy processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In Situ Formation of Carbon Nanotubes Encapsulated within Boron Nitride Nanotubes via Electron Irradiation

We report experimental evidence of the formation by in situ electron-irradiation of single-walled carbon nanotubes (C NT) confined within boron nitride nanotubes (BN-NT). The electron radiation stemming from the microscope supplies the energy required by the amorphous carbonaceous structures to crystallize in a tubular form in a catalyst free procedure, at room temperature and high vacuum. The structural defects resulting from the interaction of the shapeless carbon with the BN nanotube are corrected in a self-healing process throughout the crystallinization. Structural changes developed during the irradiation process such as defects formation and evolution, shrinkage, and shortness of the BN-NT were in situ monitored. The outer BN wall provides a protective and insulating shell against environmental Perturbations to the inner C-NT without affecting their electronic properties, as demonstrated by first principles calculations.

36 MATERIALS SCIENCE↗

Robust method for broadband efficiency enhancement of electron photocathodes using optical interferences

In this work, we demonstrate the key features of an interference cathode using both simulations and experiments. We deposit Cs 3 Sb photocathodes on Ag to produce an interference enhanced photocathode with 2–5× quantum efficiency (QE) enhancement using a robust procedure that requires only a smooth metal substrate and QE monitoring during growth. We grow both an interference cathode (Ag substrate) and a typical photocathode (Si reference substrate) simultaneously to confirm that the effects are due to optical interactions with the substrate rather than photocathode composition or surface electron affinity differences. Growing the cathodes until the QE converges shows both the characteristic interference peaks during growth and the identical limiting case where the cathode is “infinitely thick,” in agreement with simulations. We also grow a cathode until the QE on Ag peaks and then stop the growth, demonstrating broadband QE enhancement.

36 MATERIALS SCIENCE↗

Simulator evaluation of system identification with on-line control law update for the controls and astrophysics experiment in space

A procedure for optimizing the performance of large flexible spacecraft that require active vibration suppression to achieve required performance is presented. The procedure is to conduct on-orbit testing and system identification followed by a control system design. It is applied via simulation to a spacecraft configuration currently being considered for flight test by NASA - the Controls, Astrophysics, and Structures Experiment in Space (CASES). The system simulator is based on a NASTRAN finite element structural model. A finite number of modes is used to represent the structural dynamics. The system simulator also includes models of the electronics, actuators, sensors, the digital controller, and the internal and external disturbances. Nonlinearities caused by quantization are included in the study to examine tolerance of the procedure to modelling errors. Disturbance and sensor noise is modelled as a Gaussian process. For system identification, the system is excited using sinusoidal inputs at the resonant frequencies of the structure using each actuator. Mode shapes, frequencies, and damping ratios are identified from the unforced response sensor data after each excitation. Then, the excitation data is used to identify the actuator influence coefficients. The results of the individual parameter identification analyses are assembled into an aggregate system model. The control design is accomplished based only on the identified model using multi-input/output linear quadratic Gaussian theory. Its performance is evaluated based on time-to-damp as compared with the uncontrolled structure.

Montgomery, Raymond C.↗

Effect of shells on photoluminescence of aqueous CdTe quantum dots

Graphical abstract: Size-tunable CdTe coated with several shells using an aqueous solution synthesis. CdTe/CdS/ZnS quantum dots exhibited high PL efficiency up to 80% which implies the promising applications for biomedical labeling. - Highlights: • CdTe quantum dots were fabricated using an aqueous synthesis. • CdS, ZnS, and CdS/ZnS shells were subsequently deposited on CdTe cores. • Outer ZnS shells provide an efficient confinement of electron and hole inside the QDs. • Inside CdS shells can reduce the strain on the QDs. • Aqueous CdTe/CdS/ZnS QDs exhibited high stability and photoluminescence efficiency of 80%. - Abstract: CdTe cores with various sizes were fabricated in aqueous solutions. Inorganic shells including CdS, ZnS, and CdS/ZnS were subsequently deposited on the cores through a similar aqueous procedure to investigate the effect of shells on the photoluminescence properties of the cores. In the case of CdTe/CdS/ZnS quantum dots, the outer ZnS shell provides an efficient confinement of electron and hole wavefunctions inside the quantum dots, while the middle CdS shell sandwiched between the CdTe core and ZnS shell can be introduced to obviously reduce the strain on the quantum dots because the lattice parameters of CdS is situated at the intermediate-level between those of CdTe and ZnS. In comparison with CdTe/ZnS core–shell quantum dots, the as-prepared water-soluble CdTe/CdS/ZnS quantum dots in our case can exhibit high photochemical stability and photoluminescence efficiency up to 80% in an aqueous solution, which implies the promising applications in the field of biomedical labeling.

36 MATERIALS SCIENCE↗

Complex Electronic Structure of Rare Earth Activators in Scintillators

To aid and further the understanding of the microscopic mechanisms behind the scintillator nonproportionality that leads to degradation of the attainable energy resolution, we have developed theoretical and experimental algorithms and procedures to determine the position of the 4f energy levels of rare earth dopants relative to the host band edge states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BAYESIAN CONFIDENCE LIMITS OF ELECTRON SPECTRA OBTAINED THROUGH REGULARIZED INVERSION OF SOLAR HARD X-RAY SPECTRA

Many astrophysical observations are characterized by a single, non-repeatable measurement of a source brightness or intensity, from which we are to construct estimates for the true intensity and its uncertainty. For example, the hard X-ray count spectrum from transient events such as solar flares can be observed only once, and from this single spectrum one must determine the best estimate of the underlying source spectrum I({epsilon}), and hence the form of the responsible electron spectrum F(E). Including statistical uncertainties on the measured count spectrum yields a 'confidence strip' that delineates the boundaries of electron spectra that are consistent with the observed photon spectrum. In this short article, we point out that the expectation values of the source brightness and its variance in a given photon energy bin are in general not (as has been assumed in prior works) equal to n, the number of counts observed in that energy bin. Rather, they depend both on n and on prior knowledge of the overall photon spectrum. Using Bayesian statistics, we provide an explicit procedure and formulas for determining the 'confidence strip' (Bayesian credible region) for F(E), thus providing rigorous bounds on the intensity and shape of the accelerated electron spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Wall loss of atomic nitrogen determined by ionization threshold mass spectrometry

In the afterglow of an inductively coupled N{sub 2} plasma, relative N atom densities are measured by ionization threshold mass spectrometry as a function of time in order to determine the wall loss time t{sub wN} from the exponential decay curves. The procedure is performed with two mass spectrometers on different positions in the plasma chamber. t{sub wN} is determined for various pressures, i.e., for 3.0, 5.0, 7.5, and 10 Pa. For this conditions also the internal plasma parameters electron density n{sub e} and electron temperature T{sub e} are determined with the Langmuir probe and the rotational temperature T{sub rot}{sup N{sub 2}} of N{sub 2} is determined with the optical emission spectroscopy. For T{sub rot}{sup N{sub 2}}, a procedure is presented to evaluate the spectrum of the transition υ{sup ′}=0→υ{sup ″}=2 of the second positive system (C{sup 3}Π{sub u}→B{sup 3}Π{sub g}) of N{sub 2}. With this method, a gas temperature of 610 K is determined. For both mass spectrometers, an increase of the wall loss times of atomic nitrogen with increasing pressure is observed. The wall loss time measured with the first mass spectrometer in the radial center of the cylindrical plasma vessel increases linearly from 0.31 ms for 3 Pa to 0.82 ms for 10 Pa. The wall loss time measured with the second mass spectrometer (further away from the discharge) is about 4 times higher. A model is applied to describe the measured t{sub wN.} The main loss mechanism of atomic nitrogen for the considered pressure is diffusion to the wall. The surface loss probability β{sub N} of atomic nitrogen on stainless steel was derived from t{sub wN} and is found to be 1 for the present conditions. The difference in wall loss times measured with the mass spectrometers on different positions in the plasma chamber is attributed to the different diffusion lengths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗