Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electricity Demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Energy Arbitrage with Hydrogen: HTSE + Combustion Turbine

The Light Water Reactor Sustainability (LWRS) program seeks to keep Nuclear Power Plants (NPPs) competitive in the changing energy market. The Flexible Plant Operation and Generation (FPOG) pathway investigates Energy Storage Systems (ESS) to give operators an alternative to curtailment or paying to put power on the grid. This work investigates the concept of diverting heat and electricity to High Temperature Steam Electrolysis (HTSE) to produce hydrogen when grid demand is low, storing that hydrogen, then burning it in a combustion turbine to produce zero-emission electricity when grid demand is high. A process model of the combustion turbine was developed in Aspen HYSYS, which was used to complete a parametric analysis and techno-economic analysis.

08 HYDROGEN↗

Case Study: Hybrid Carbon Conversion Using Low-Carbon Energy Sources in Coal-Producing States

The demand for more carbon efficient power sources and a decrease in natural gas prices has decreased the desire for coal power. This decrease in demand has led to massive job losses in coal mining regions over the past decade. The purpose of this project is to develop a hybrid energy system utilizing both a coal power plant and advanced reactor, which is competitive with natural gas by improving on profitability and decreasing carbon emissions. This report details the problem with a summary of the impact on the coal industry and the availability of renewable energy sources in the Appalachian region. Because of the geography of the region, variable renewable energy sources are not available without significant size and siting restrictions. However, biomass in the form of wood waste is abundant and can be used as a carbon neutral energy source. Combining biomass and coal processing, in addition to thermal power plants, can increase system profits and efficiency by providing peaking power and conversion opportunities for secondary markets. The electric load is based on publicly available demand data from Appalachian Power, which services the western Virginia and southern West Virginia in the Appalachian region. The demand information is combined by service, normalized, and scaled to an average demand of 1000 kW, which will be the basis for sizing the hybrid energy system. A traditional screening curve analysis for a coal plant and advanced reactor shows that the least cost design varies significantly based on the assumed discount rate and capital recovery period. An optimization program to size the design in TEAL based on the load curve gives 10 optimal designs, all with a negative resulting net present value (NPV) and a coal plant capacity of less than 15%. Including profits from selling captured carbon at a flat rate results in a positive NPV; however, the coal capacity factor only increases to about 40%. There are limitations with this optimization as well since the price of CO2 is likely to decrease as more is sold to the conversion market. The suggested design will combine coal power, an advanced reactor, and coal and biomass coprocessing to produce a variety of products that can be sold to the conversion market while increasing system efficiency. The analysis of conversion pathways for coal and biomass reveals that multiple options will need to be included in the analysis to produce the optimal system design. Three systems will be optimized and compared to determine the best design based on the figures of merit of total NPV and cost of carbon avoided. The first system will include a coal power plant and an advanced reactor that will sell electricity to the grid to meet demand and sell captured carbon to the conversion market. The second system adds a high-temperature steam electrolysis plant, which will utilize electricity during times of low demand to produce hydrogen and sell it to the conversion market. The third system adds biomass and coal processing with options for hydrocarbon oils, syngas to be produced for the conversion market, and electricity generation to power components within the system or provide peaking power. This analysis will be based on a new approach that combines traditional screening curve methods with a dispatch algorithm that optimizes the system based on the opportunity cost of different production options. The resulting optimization algorithm should provide results with less processing time than HERON’s decision tree method. The results from this analysis will determine an optimal design and reinforce the benefits of coal power when used in a hybrid energy system. The initial results show that the addition of a secondary market for carbon sales could result in a positive NPV and increases the capacity factor of the coal plant as compared to a design with only sales to the electricity market. The addition of more markets and additional coal consumption from biomass coprocessing could increase NPV further, replace carbon in other markets through the sale of biomass-derived hydrocarbons, and demonstrate the value of coal power technology.

01 COAL, LIGNITE, AND PEAT↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Hardware Specification and Reference Design for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner. To address the needs of the SMBs, the Department of Energy’s Building Technologies Office jointly funded Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to design, develop, test, and validate a low-cost, interoperable, user-centric, retrofit supervisory controller kit (SC-SMB) that can be used to continuously optimize energy consumption and deliver demand flexibility of SMBs, including all-electric buildings, and provide a means for maximizing decarbonization benefits. The team also includes industry partners Edo and Intellimation. Previously, the team drafted an SC-SMB system specification document (Goodman et al. 2023). This document describes a reference design of a low-cost supervisory control system for SMBs, including the various hardware components, software system, and an example implementation of the reference design. The final release of the reference design is planned for December 2025. Section 2.0 of the report documents the relevant building types that the SC-SMB system is suitable for. Section 3.0 documents the various hardware components, their function, cost, whether they are off-the-shelve, support standard communication, etc., and the software system. An example deployment in a 10,000-sf building with six rooftop units, a hot water heater, solar, and storage is described in Section 4.0. The planned next steps are described in Section 5.0, and references are listed in Section 6.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainable Coal Tar Pitch Carbon Fiber Manufacturing

Coal is a versatile resource that has historically propelled the Industrial Revolution, transportation, and energy generation, and continues to meet needs for power. The United States possesses the largest worldwide coal reserves (with a 2019 total production-to-recoverable-reserves ratio of 0.05) that are of high quality and are cost-effective to recover (i.e., $0.03/kg–$0.10/kg). However, the demand of coal for power generation has declined because of a shift to natural gas (because of lower natural gas prices) and to renewable energy sources. This decline has affected the economic viability US coal industry. Historically, domestic demand for coal was driven mostly by the electric power sector, which accounts for about 93% of the total demand, followed by industrial uses (primarily for cement and chemicals at a minimal level) and steel production (coke). The complex, dense carbon chemical structure of coal, abundant domestic supply, and stable, low price gives it great potential for use in a wide range of value-added non-fuel coal products (e.g., nanomaterials at $20,000/kg–$100,000/kg and commercial-grade carbon fiber at $22/kg–$33/kg), as well as in upgraded coal fuels.

01 COAL, LIGNITE, AND PEAT↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

Greenhouse gas emissions embodied in the U.S. solar photovoltaic supply chain

Abstract Solar photovoltaic (PV) electricity is considered to be an important source of electricity generation in the quest for net-zero carbon emissions. However, the growth of solar electricity is creating both increased material demands and increased greenhouse gas (GHG) emissions from silicon and PV manufacturing (also referred to as embodied GHG emissions of solar electricity). Here we analyze the silicon and solar PV supply chain for the United States (U.S.) market and find that the embodied GHG emissions of solar PV panel materials (such as silicon), manufacture, logistics, and installation in the U.S. given the current supply chain are 36 g CO 2 e kWh −1 of solar electricity generated. Eighty-five percent of the embodied GHG emissions are from PV panel production processes in China and other Asia–Pacific countries. Moving the silicon and PV manufacturing to the U.S. would reduce the embodied GHG emissions of solar electricity by 16% from its current level, primarily because of the lower GHG emission intensity of the U.S. electrical grid and the lower GHG emissions for aluminum electrolysis in North America. Future scenario analysis shows that by 2030, with the U.S. PV domestic supply chain and its decarbonized grid electricity and aluminum production, as well as improving PV conversion efficiency, the embodied GHG emissions of solar electricity in the U.S. will be reduced to 21 g CO 2 e kWh −1 .

14 SOLAR ENERGY↗

Modeling and stability analysis for the upper atmosphere research satellite auxiliary array switch component

A feedback control system, called an auxiliary array switch, was designed to connect or disconnect auxiliary solar panel segments from a spacecraft electrical bus to meet fluctuating demand for power. A simulation of the control system was used to carry out a number of design and analysis tasks that could not economically be performed with a breadboard of the hardware. These tasks included: (1) the diagnosis of a stability problem, (2) identification of parameters to which the performance of the control system was particularly sensitive, (3) verification that the response of the control system to anticipated fluctuations in the electrical load of the spacecraft was satisfactory, and (4) specification of limitations on the frequency and amplitude of the load fluctuations.

Wolfgang, R.↗

Modeling Variable Renewable Energy and Storage in the Power Sector

The emergence of variable renewable energy and battery storage technologies have fundamentally transformed the electric power sector and generated demand for analysis to understand their roles in future energy systems. Although unique characteristics of these resources are well-recognized and require more sophisticated methodologies to capture effectively, guidance is limited on best practices and research gaps. This paper selectively reviews recent literature and draws upon our collective modeling experience to offer recommendations to analysts and consumers of model outputs on approaches for modeling variable renewable energy and storage in long-term electric sector models. We focus on regional- and national-scale models with technological, temporal, and spatial detail given their prevalence in planning and policy analysis, though insights are applicable in other settings. The review highlights how the research frontier has advanced in representing renewables and energy storage over the past decade; however, given the many considerations involved with appropriately capturing salient economic and operational characteristics of renewables, there is a gap between commonly used models and state-of-the-art methods. Model simplifications can materially impact policy analysis associated with power sector decarbonization and high renewables deployment, and improving model representations of variable renewables can enhance insights for policymakers and other stakeholders. This review can point the way for improved methods for established models and designs for emerging ones.

energy and environmental policy↗

Hybrid chemical-electric trajectories for a Mars Sample Return orbiter

The Earth return orbiter component of a Mars sample return campaign is a high total impulse mission with challenging timeline constraints. These competing demands mean a hybrid chemical-electric propulsion architecture may be needed for a feasible design, with chemical propulsion providing timely impulse and electric propulsion providing high volume impulse. We describe an approach to map out the hybrid trajectory design space and create a database to use in conjunction with a spacecraft design tool, enabling co-optimization of trajectory and spacecraft. This method is applied to both the outbound and inbound legs of a Mars sample return mission concept.

Lock, Rob↗

Community and Passenger Survey Responses for Bastrop, Texas Low-Speed Electric Vehicle Mobility Service Project

This document describes the contents of the following data products: 1. ALL-survey_results_NREL_LiveWire_04_14_2023 (Excel file with two worksheets) 2. eCab_DOE_NREL_LiveWire_04_14_2023_results_all_surveys_except_SP_csv (CSV file) 3. eCab_DOE_NREL_LiveWire_04_14_2023_SP_survey_results_only_csv (CSV file). These data products contain the results of the surveys conducted throughout the DOE-funded Electric First-/Last-Mile On-Demand Shuttle Service for Rural Communities in Central Texas project. The Excel file is the original database of all the survey results (contained in two worksheets). The CSV files are those two worksheets saved as individual CSV files.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseload Hydrogen Production Using Nuclear and Renewable Energy: A Comparative Analysis

As the global push towards net zero carbon gains momentum, the demand for clean hydrogen is expected to grow rapidly across various sectors, including transportation, industries and electrical grids. To meet this growing hydrogen demand, baseload hydrogen production facilities capable of providing a continuous and reliable supply of hydrogen will be necessary throughout the world. This paper explores the technoeconomic feasibility of establishing baseload electrolytic hydrogen production facilities in the United States, utilizing different clean generation resources. The key criteria include maintaining a consistent supply of clean hydrogen without putting baseload demand stress to already vulnerable power grid. In order to do that, the proposed facilities will host onsite clean power generation and energy storage technologies. The proposed facilities can capitalize on available investment and production incentives and have ability to export excess electricity to the utility at a bulk price. Several scenarios are considered based on the clean energy resources to support the electrolysis process including light water reactors (LWRs) currently evaluating retirement options, wind, solar PVs, and advanced small modular reactors (SMRs). For each scenario, a hypothetical hydrogen production facility is considered in a location in the US where the primary generation resource is at its peak strength. Comparative analysis in this paper reveal that the nuclear power plants are most economically viable for baseload hydrogen production facilities, outperforming renewable-based facilities with significantly lower levelized cost of hydrogen (LCOH). Even under best-case scenarios for resource availability, incentives and export prices, renewable-based facilities face challenges due to daily and seasonal generation variability, resulting in large installation sizes and lower capacity factors. Among renewable-based facilities, complementarity hybrids, providing more stable power supply, demonstrate superior economics compared to facilities based on a single renewable technology. While LWR-powered facility can achieve a negative LCOH with incentives, SMR-powered facilities can provide economic hydrogen supply with LCOH below $1/kg with high temperature electrolysis option. The analysis in this paper underscores the pivotal role of nuclear energy in the future hydrogen economy.

08 - HYDROGEN↗

The Demand-Side Opportunity: The Roles of Distributed Solar and Building Energy Systems in a Decarbonized Grid

Building energy systems represent a significant and largely untapped demand-side grid resource. Buildings use about 75% of electricity in the United States, including around 80% of peak demand, meaning that changes in building energy use have significant implications for grid operations. Building energy technologies-including energy-efficient devices, flexible loads, and energy storage-can be coordinated and aggregated to perform similar functions as centralized grid assets. Recent advances in information and communication (ICT) technologies have significantly improved building energy technology automation, coordination, and aggregation capabilities. With declining costs and technological advances, building energy systems can increasingly compete with conventional grid assets such as natural gas plants. Building energy technologies enable the deployment of distributed solar photovoltaics (DPV). Energy-efficient buildings allow DPV to meet greater shares of building load while flexible loads and energy storage can reshape building load profiles to optimize the on-site use of DPV. Optimized on-site use of DPV increases the value proposition for DPV adoption and can help utilities cost-effectively integrate higher levels of DPV penetration. Together, DPV and building energy technologies could help grids achieve deep decarbonization more quickly and cost-effectively.

14 SOLAR ENERGY↗

Stochastic Optimization and Uncertainty Quantification of Natrium-based Nuclear-Renewable Energy Systems for Flexible Power Applications in Deregulated Markets

Rapid integration of variable renewable energy sources (VRES) has made modeling and stochastic optimization of hybrid energy systems crucial for studying their long-term performance and viability. However, most studies have focused on just historical data, which may be unreliable for capturing short-term fluctuations, rare events, and long-term patterns of energy demand, price, and the variability of renewable energy sources. For this study, optimal synthetic time series models were developed using Wasserstein distance. The models were validated by comparing the key statistical measures against those of the historical data. They were then used to optimize the integrated Natrium-style advanced energy systems and their long-term (30 years) economics. The stochastic model performs bi-level optimization to find the optimal sizes for the balance of plant and thermal energy storage, while also optimizing energy dispatch to achieve the maximum net present value. In studies of two deregulated markets (California ISO and the Electric Reliability Council of Texas), the integrated Natrium-style system performed better in CAISO than in ERCOT, given higher and more consistent electricity prices during peak-demand periods. The potentially enlarged cost associated with the variable operation and maintenance of the TES system also plays a significant role in driving the system sizing, thus its impacts on the system are investigated in detail through comparison against a baseline case. The study also finds that the bi-level optimization results based on stochastic gradient descent closely match the grid search results. The uncertainty quantification of the stochastic signals provides further NPV-related insights and probability distributions for the case studies. The normal standard error of the mean of NPV for the case with and without TES VOM for CAISO were found to be 7.73M (plus-minus sign) 1.09M USD and 104.99M (plus-minus sign) 1.25M USD, respectively based on a 95% confidence. Given the relatively small NPV variance based on 150 samples, the analysis affords the most robust possible prediction of the techno-economic performance of the integrated Natrium-style energy systems.

25 ENERGY STORAGE↗

User's manual for the Shuttle Electric Power System analysis computer program (SEPS), volume 2 of program documentation

The Shuttle Electric Power System Analysis SEPS computer program which performs detailed load analysis including predicting energy demands and consumables requirements of the shuttle electric power system along with parameteric and special case studies on the shuttle electric power system is described. The functional flow diagram of the SEPS program is presented along with data base requirements and formats, procedure and activity definitions, and mission timeline input formats. Distribution circuit input and fixed data requirements are included. Run procedures and deck setups are described.

Bains, R. W.↗

NG-CT Peaker Upgrades with Bottoming Cycle: Preliminary Analysis

The National Energy Technology Laboratory (NETL) has conducted a preliminary analysis exploring a significant opportunity to increase the nation's power grid capacity and reliability. The study focuses on retrofitting under-utilized natural gas combustion turbines (NG-CTs), often called "peaker" plants, with a bottoming cycle to capture waste heat and generate additional electricity. This analysis shows that upgrading these existing assets could add approximately 26,250 MW of new power capacity across the United States. A detailed study of the PJM Interconnection, the nation's largest grid operator, confirmed the benefits of these upgrades. Key findings for the PJM region include: - A median increase in the plants' capacity factor by 17 percentage points. - A projected 36.2% median reduction in the levelized cost of electricity (LCOE) for the upgraded plants, with nearly 88% of them expected to break even. - An average reduction in the regional wholesale price of electricity by approximately 3.0% in the year 2030. - A significant boost to grid reliability, with a 46% reduction in projected Loss of Load Hours (LOLH). These findings suggest that retrofitting peaker plants is a promising and economically viable strategy to enhance grid performance, reduce electricity costs, and meet future demand without the challenges associated with building entirely new facilities.

bottoming cycle↗

ASPIRES: Airport Shuttle Planning and Improved Routing Event-driven Simulation

Most of the existing traffic simulation packages require significant calibration work to be able to reflect reality. To evaluate special operations including emerging technologies, a microscopic simulation that tracks detailed interactions of all the elements of the traffic systems is usually needed. This type of simulation is usually computationally demanding. This work developed an Airport Shuttle Planning and Improved Routing Event-driven Simulation (ASPIRES) package to simulate and evaluate current, potential, and future airport shuttle operations. Here, the simulation was driven by data and thus did not require much calibration effort. The discrete-event simulation nature of ASPIRES makes the simulation computationally efficient. Simulating 1 day of shuttle operations takes less than 2s. The study site of this work is the Dallas/Fort Worth International Airport in the U.S. The shuttle service that connects the five terminals of the airport and the rental car center was studied. Travel times, dwell times, and passenger arrivals were simulated using empirical distributions derived mainly from real data to capture the stochastic nature of the rental car center shuttle bus operations. Data on bus miles traveled, bus energy consumption, passenger wait times, and passengers left behind at stops were collected to study the trade-off between energy use and passenger experience. Electric bus and on-demand bus operations were also included. The simulation outputs can show passengers statistics at terminals, shuttles statistics, and charging station statistics. ASPIRES cannot be used to model a generic traffic system but is well-suited for fleet systems.

33 ADVANCED PROPULSION SYSTEMS↗

Optimization Framework to Assess the Demand Response Capacity of a Water Distribution System

As large electricity consumers, water distribution system (WDS) pumping stations have the potential to become meaningful participants in demand response (DR) programs. The authors propose an optimization framework for assessing the DR capacity of a WDS and identifying the optimal bidding strategy for maximizing WDS revenue in the DR spot market. The proposed mixed integer linear programming (MILP) model overcomes computational constraints of previous DR optimization models by adopting a preprocessing procedure to minimize the number of binary variables and implementing a convex relaxation technique to linearize the hydraulic equations. The proposed MILP model also explicitly accounts for varying levels of risk tolerance of WDS operators by varying the recovery period over which pumping returns to business-as-usual operation. The optimization framework is implemented on a skeletonized 48-node WDS model that includes 7 pumps, 6 tanks, and 39 pipes. Using a simulated DR event and water consumption profile, the authors derive the optimal DR supply curves (i.e., compensation price versus load curtailment quantity) and revenue potential of the WDS under six scenarios for DR participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗