Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Description and operating performance of a parallel-rail electric-arc system with helium driver gas for the Langley 6-inch expansion tube

A parallel-rail arc-discharge system to heat and pressurize the initial helium driver gas of the Langley 6-inch expansion tube is described. This system was designed for a 2.44-m-long driver vessel rated at 138 MPa, with a distance between rails of 20.3 cm. Electric energy was obtained from a capacitor storage system rated at 12,000 V with a maximum energy of 5 MJ. Tests were performed over a range of energy from 1.74 MJ to the maximum value. The operating experience and system performance are discussed, along with results from a limited number of expansion-tube tests with air and carbon dioxide as test gases.

Moore, J. A.↗

A numerical study of thunderstorm electrification - Model development and case study

A numerical model was developed for examining the thunderstorm electrification process in which it is assumed that the electrification is entirely due to noninductive charge transfer between colliding ice crystals and hail. Since this ice-hail charge mechanism is very dependent on particle sizes and distributions, an explicit microphysical framework is used. To maintain simplicity, the electrification model is kinematic; thus the temperature and velocity fields are input into the electrification model. The cloud model of Taylor (1989) was used to generate the temperature and velocity fields to examine the July 19, 1981, Cooperative Convective Precipitation Experiment thundercloud. Using these fields, the electrification model produced time-dependent ice particle concentrations, radar reflectivities, charge, and vertical electric field distributions in good general agreement with those observed. The model produced a maximum electric field strength of 1.27 kV/cm, which is on the order of that needed for lightning initiation, and this maximum occurred very close to the time of the observed discharge. Thus, the ice-hail charge mechanism appears to have played an important role in the electrical development of the July 19 cloud.

Norville, K.↗

Mesoscale observations of lightning from Space Shuttle

Motion pictures have been taken at night by astronauts on the space shuttle showing lightning discharge that spread horizontally at speeds of 100,000/msec for distances over 60 km. Tape recordings have been made of the accompanying optical pulses detected with a photocell optical system. The observations show that lightning is often a mesoscale phenomena that can convey large amounts of electric charge to Earth from an extensive cloud system via a cloud to ground discharge.

Vonnegut, B.↗

Mesoscale observations of lightning from Space Shuttle

Motion pictures have been taken at night by astronauts on the space shuttle showing lightning discharge that spread horizontally at speeds of 100,000/msec for distances over 60 km. Tape recordings have been made of the accompanying optical pulses detected with a photocell optical system. The observations show that lightning is often a mesoscale phenomena that can convey large amounts of electric charge to earth from an extensive cloud system via a cloud to ground discharge.

Vonnegut, B.↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 micrometers in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 micrometers or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Electric Propulsion↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 μm in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 μm or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Rohit Shastry↗

Gas composition sensing using carbon nanotube arrays

A method and system for estimating one, two or more unknown components in a gas. A first array of spaced apart carbon nanotubes (''CNTs'') is connected to a variable pulse voltage source at a first end of at least one of the CNTs. A second end of the at least one CNT is provided with a relatively sharp tip and is located at a distance within a selected range of a constant voltage plate. A sequence of voltage pulses {V(t.sub.n)}.sub.n at times t=t.sub.n (n=1, . . . , N1; N1.gtoreq.3) is applied to the at least one CNT, and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of a curve I(t.sub.n) for current or a curve e(t.sub.n) for electric charge transported from the at least one CNT to the constant voltage plate. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas.

Li, Jing↗

Azimuthal structures and turbulent transport in Penning discharge

Azimuthal structures in cylindrical Penning discharge are studied with a 2D3V radial–azimuthal PIC/MCC model with the axial magnetic field. The discharge is self-consistently supported by ionization due to the axial injection of electrons. It is shown that the steady-state discharge can be supported in two different regimes with different types of observed azimuthal structures. The transition between the regimes is controlled by the mechanism of the energy input to the discharge. In the first regime (low energy of the injected electrons), with the pronounced m = 1 spoke activity, the power input is dominated by the energy absorption due to the radial current and self-consistent electric field. In the other regime (higher energy of the injected electrons), with prevalent small-scale m > 1 spiral structures, and the lower values of the anomalous transport, the total energy deposited to the discharge is lower and is mostly due to the direct input of the kinetic energy from the axial electron beam. Here we show that the large (m = 1) spoke and small-scale structures occur as a result of Simon–Hoh and lower hybrid instabilities driven by the electric field, density gradient, and collisions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Unit of Lightning

For the past century, scientists have made quantitative measurements of lightning discharges. In the process, they refined the definition of a lightning unit, or basic quantum of lightning, in order to base it on observable parameters. Although many components of a lightning discharge have been identified, lightning usually occur in groups of discharges or pulses that, although complex, can be organized into units of flashes. This unit definition is based mainly on measurements of lightning from electric field, video, and ground flash lightning locating networks. More recent instrumentation with various combinations of high sensitivity, high temporal, or high spatial resolution often measure signals produced by lightning that do not cleanly divide into flashes. The data from these systems indicate the need or a more fundamental unit for lightning. Such a unit would be of benefit for both basic understanding of lightning and comparing lightning information between instruments. Without a common lightning unit definition, intercomparisons are difficult. For an example, the Lightning Detection And Ranging system (LDAR) at Kennedy Space Center (KSC) have detected ,flash' rates as high as 600 per minute while analysis based on the Advanced Ground Based Field Mill network (AGBFM) detect only 33 "flashes" per minute in the same area and time periods. The satellite based Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) sometimes see single "flashes" that last longer than 10 seconds. Such long duration flashes are not found in electric field records or ground strike location system data sets. The unit of lightning should be based on the fundamental components of the lightning discharge. This should make the unit as generally applicable as possible. For example, studies of NO(x) production by lightning depend on parameters of the individual lightning channels and not the summary flash characteristics. For such studies, the best unit of lightning may be closer to the classical stroke in the electric field data sets, flash in the LDAR data sets, and group in the OTD/LIS data sets. For this type of study, however, more than just the stroke count information is needed. In this paper, we will outline the current definitions of the unit of lightning and propose new basic definitions for the unit of lightning. Since different instruments detect lightning in different ways and different studies may need almost mutually exclusive aspects of the lightning discharge, there may not be a single definition of the unit of lightning that can be applied to all systems and all studies. However, common components can be found since all instrumentation are detecting aspects of the same phenomenon.

Mach, Douglas M.↗

Electric fields in the solar atmosphere - A review

A review is presented of remote sensing techniques which measure the electric field component transverse to the line of sight and achieve a sensitivity range of 5-10 V/cm. Three models are shown to predict quasistatic, macroscopic values of E(parallel), the electric field component parallel to the magnetic vector, beyond the sensitivity range considered. These processes are: the discharge model of flares; the models of return currents related to flare particle beams; and the models of neutral sheets related to two-ribbon flares and postflare loops. Time dependent electric fields related to MHD and plasma waves, and to plasma disturbance, may allow the detection of both E components (parallel and perpendicular). The uncertainty relating to the emission measures, time scales, volumes, and plasma conditions of these flares and electrified plasma volumes is emphasized. It is pointed out, however, that important information can be obtained by observing electric fields at existing sensitivity levels. By measuring these E-fields, the understanding of flares and related dynamic events can be improved.

Foukal, P.↗

Li Stripping Behavior of Anode‐Free Solid‐State Batteries Under Intermittent‐Current Discharge Conditions

Anode‐free manufacturing holds promise to enable high energy densities and lower Lithium (Li)‐metal solid‐state batteries (LMSSBs). Nevertheless, in contrast to thick Li foil (>50 µm), the stripping capacity of in situ‐formed Li (10–30 µm) is limited due to diminished creep flow, resulting in reduced accessible capacity. This study explores the correlation between stripping capacity and surface roughness of garnet Li 7 La 3 Zr 2 O 12 (LLZO) solid electrolyte. The results reveal that stripping capacity can be enhanced through the surface modification of solid electrolytes. Additionally, this study scrutinizes the stripping behavior of in situ Li under intermittent‐current discharge conditions, which are more relevant to the operational conditions of electric vehicles (EVs). It is demonstrated that, when compared to constant‐current stripping, intermittent‐current stripping effectively suppresses void formation and enhances the stripping capacity of in situ Li by 40%. It is considered that the intermittent current inhibits the accumulation of Li vacancies, thereby delaying the void formation. These findings provide valuable insights into the development of high‐performance anode‐free LMSSBs for EVs.

25 ENERGY STORAGE↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Electrode Mesoscale as a Collection of Particles: Coupled Electrochemical and Mechanical Analysis of NMC Cathodes

Battery electrodes are composed of polydisperse particles and a porous, composite binder domain. These materials are arranged into a complex mesostructure whose morphology impacts both electrochemical performance and mechanical response. We present image-based, particle-resolved, mesoscale finite element model simulations of coupled electrochemical-mechanical performance on a representative NMC electrode domain. Beyond predicting macroscale quantities such as half-cell voltage and evolving electrical conductivity, studying behaviors on a per-particle and per-surface basis enables performance and material design insights previously unachievable. Voltage losses are primarily attributable to a complex interplay between interfacial charge transfer kinetics, lithium diffusion, and, locally, electrical conductivity. Mesoscale heterogeneities arise from particle polydispersity and lead to material underutilization at high current densities. Particle-particle contacts, however, reduce heterogeneities by enabling lithium diffusion between connected particle groups. While the porous composite binder domain (CBD) may have slower ionic transport and less available area for electrochemical reactions, its high electrical conductivity makes it the preferred reaction site late in electrode discharge. Mesoscale results are favorably compared to both experimental data and macrohomogeneous models. This work enables improvements in materials design by providing a tool for optimization of particle sizes, CBD morphology, and manufacturing conditions.

42 ENGINEERING↗

Radiated and conducted EMI from a 30-cm ion thruster

In order to properly assess the interaction of a spacecraft with the EMI environment produced by an ion thruster, the EMI environment was characterized. Therefore, radiated and conducted emissions were measured from a 30-cm mercury ion thruster. The ion thruster beam current varied from zero to 2.0 amperes and the emissions were measured from 5 KHz to 200 MHz. Several different types of antennas were used to obtain the measurements. The various measurements that were made included: magnetic field due to neutralizer/beam current loop; radiated electric fields of thruster and plume; and conducted emissions on arc discharge, neutralizer keeper and magnetic baffle lines.

Whittlesey, A. C.↗

ESD Challenges for NASA Astronauts in Upcoming Missions

Electrostatic charging of insulators is well known to pose potential threats to electronic systems under terrestrial systems. We were asked to evaluate potential hazards associated with replacement of an electronics board in the vacuum of space during the upcoming Hubble Service Repair mission in September 2008. A device called a "tribot" was built to simulate triboelectric charging of several insulators that are capable of contact charging against astronaut's gloves and suit materials. Materials were evaluated as the extent of not only the magnitude of electric fields generated by the frictional action, but also any resulting discharge which would be a source of EMI. Experimental results are quite surprising and unexpected when compared with tests performed under ambient conditions under dry and humid air.

Buhler, Charles R.↗

Internal Charging

(1) High energy (>100keV) electrons penetrate spacecraft walls and accumulate in dielectrics or isolated conductors; (2) Threat environment is energetic electrons with sufficient flux to charge circuit boards, cable insulation, and ungrounded metal faster than charge can dissipate; (3) Accumulating charge density generates electric fields in excess of material breakdown strenght resulting in electrostatic discharge; and (4) System impact is material damage, discharge currents inside of spacecraft Faraday cage on or near critical circuitry, and RF noise.

Minow, Joseph I.↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

NASAs Evolutionary Xenon Thruster (NEXT) Long-Duration Test (LDT) is part of the comprehensive service life assessment of the NEXT thruster. The test was voluntarily terminated in April 2014 after accumulating 51,184 hours of high voltage operation, processing 918 kg of xenon, and delivering 35.5 MN-s of total impulse. This presentation covers the post-test inspection of the thruster hardware, in particular of the discharge chamber and other miscellaneous components such as propellant isolators and electrical cabling.

Ion Thrusters↗

LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗