Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Diagnosis of PV Cell Passivation Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on the cell ("AR c corrosion") was previously observed in studies using hot-humid test conditions with external high voltage (HV) bias. Because AR c corrosion is not well understood, mini-modules (MiMos) were examined in a comparative experiment using PERC and PERT as well as legacy Al-BSF cells. For separate MiMos with the cell circuit electrical at +1500 V, -1500 V, or unbiased "V oc", test conditions in the comparative study included 60degrees C/60% RH for 96 h, as in IEC TS 62804-1; 70degrees C/70%RH for 200 h; and 85degrees C/85% RH for 200 h. Characterizations at each read point included: camera and electroluminescence (EL) imaging, colorimetry, and I-V curve tracing. Characterizations at the final read point included: SunsVoc; spatially mapping external quantum efficiency (EQE); high resolution: photoluminescence (PL), EL, and dark lock-in thermographic (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos (stepped HV aging) and full-sized modules (outdoor aging) from previous studies. AR c corrosion was specifically observed for the glass/encapsulant/cell side of +1500 V (HV+) stressed MiMos, where appearance, color, and reflectance were the characteristics most distinguished relative to simultaneously occurring degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to silicon oxide or hydrous silica, preferentially occurring at the edges and tips of the pyramidal textured cell surface.

aging↗

Extracting Resilience Metrics From Distribution Utility Data Using Outage and Restore Process Statistics

Resilience curves track the accumulation and restoration of outages during an event on an electric distribution grid. We show that a resilience curve generated from utility data can always be decomposed into an outage process and a restore process and that these processes generally overlap in time. We use many events in real utility data to characterize the statistics of these processes, and derive formulas based on these statistics for resilience metrics such as restore duration, customer hours not served, and outage and restore rates. The formulas express the mean value of these metrics as a function of the number of outages in the event. We also give a formula for the variability of restore duration, which allows us to predict a maximum restore duration with 95% confidence. Overall, we give a simple and general way to decompose resilience curves into outage and restore processes and then show how to use these processes to extract resilience metrics from standard distribution system data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strain mapping of three-dimensionally structured two-dimensional materials

Strain plays a crucial role in tuning materials’ properties, influencing their optical, electrical, and chemical performances. In two-dimensional (2D) materials, applied stress often induces out-of-plane deformation, resulting in a more intricate three-dimensional (3D) topography, where mapping the strain remains a challenge due to the limitations of conventional characterization techniques. In this work, we introduce BRIGHT (Bragg-Rod Informed, Gradient-based Height-mapping Technique), an integrated method for reconstructing both the topography and planar strain profile of 3D-structured 2D materials using nanobeam four-dimensional scanning transmission electron microscopy (4D-STEM). We apply BRIGHT to a MoS2-MoSe2 transition metal dichalcogenide (TMD) lateral heterojunctions exhibiting built-in strain and out-of-plane ripples and show that varying heterojunction widths lead to distinct surface morphologies and corresponding changes in the planar strain distribution. These results establish a foundation for more effective strain engineering in 2D materials by accounting for out-of-plane structural features, thereby enabling more precise control of strain-dependent properties.

Mireles, Adan [Rice Univ., Houston, TX (United Sta↗

Demonstration of a modeling toolkit for the design of building electrical distribution systems

The deployment of building equipment (e.g., lighting, security) and miscellaneous electrical loads that fundamentally require DC power for operation is increasing. Powering these DC loads has traditionally required an AC/DC converter, but the installation of photovoltaic (PV) and battery energy storage systems that primarily produce DC power eliminates the need for AC/DC converters at each end-device. However, analyzing system energy efficiency and cost for different electrical distribution architectures can be challenging as software tools that support this are not readily available. This paper presents preliminary results from a laboratory verification of the Building Electrical Efficiency Analysis Model (BEEAM) toolkit that was developed to address this gap. Three different eight-luminaire lighting systems comprised of market-available products were designed and modeled: one that used traditional AC distribution, a second that used a hybrid AC -to- centralized DC electrical distribution architecture, and a third that used a hybrid AC -to- distributed DC architecture. Notably, AC/DC conversions are required in all three systems. BEEAM models for LED drivers as well as Power-over-Ethernet (PoE) switches were created using laboratory characterization data. The lighting systems were simulated in Modelica, and the results were compared with each other and physics-based expectations. Simulation results show that PoE system energy efficiency is highly dependent on both device specification (e.g., LED driver and PoE switch efficiency) and system architecture (e.g., PoE switch loading) choices, as expected. For the products and system architectures selected for this study, the two DC systems were found to be less efficient than the AC system over the course of typical operation. In future work, simulation results will be compared with laboratory measurements to validate the usefulness of this software for design, and lighting systems with integrated PV and battery energy storage will be simulated to quantify the energy performance improvements that result from the elimination of some AC/DC converters.

Waghale, Anay S.↗

Electrochemical Reactivity of Hydrogen Storage Materials: Exploring Borohydride and Hydrazinium Salt Mixtures

Electrochemical characterization of hydrogen storage materials was conducted in a non-aqueous environment to investigate the direct electrochemical release and consumption of hydrogen and the potential for regeneration. We first address the challenge of minimal solubility of the synthetic precursors, sodium borohydride (NaBH 4 ) and hydrazinium bromide (N 2 H 5 Br), in both organic and inorganic solvents. We next determine and calibrate a reference electrode formulation compatible with our non-aqueous media and analytes that demonstrates a stable reference potential. We employ cyclic voltammetry (CV) to characterize the precursors and mixtures thereof. Each CV peak is assigned to a corresponding electrochemical reaction. Using the rate-dependent CV method and Randles–Ševčík equation, we calculate the diffusion coefficient of each chemical (NaBH 4 and N 2 H 5 Br). Analysis of the CVs, coupled with 11B NMR analysis, reveals a room temperature chemical transformation of NaBH 4 and N 2 H 5 Br mixtures into hydrazine borane (N 2 H 4 BH 3 ). These results are particularly significant, considering the limited information available on the electrochemical characterization of metal borohydride and hydrazinium salt in non-aqueous media. This work establishes a foundation for adapting a non-aqueous electrochemical system to further study the borohydride family of chemistries and to design and develop electrochemical devices for direct electrical and chemical energy interconversion with hydrogen storage materials.

08 HYDROGEN↗

Electronic noise of a single skyrmion

To enable the practical use of skyrmion-based devices, it is essential to achieve a balance between energy efficiency and thermal stability while also ensuring reliable electrical detection against noise. Understanding how a skyrmion interacts with material disorder and external perturbations is thus essential. Here, we investigate the electronic noise of a single skyrmion under the influence of thermal fluctuations and spin currents in a magnetic thin film. We detect the thermally induced noise with a 1/ƒ $\gamma$ signature in the strong pinning regime but a random telegraph noise in the intermediate pinning regime. Both the thermally dominated and current-induced telegraphlike signals are detected in the weak pinning regime. Our results provide a comprehensive electronic noise picture of a single skyrmion, demonstrating the potential of noise fluctuation as a valuable tool for characterizing the pinning condition of a skyrmion. In conclusion, these insights could also aid in the development of low-noise and reliable skyrmion-based devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ComEd Climate Risk and Adaptation Outlook, Phase 1: Temperature, Heat Index, and Average Wind

This Climate Risk and Adaptation Outlook report presents the research and findings of a joint venture between Commonwealth Edison (ComEd) and Argonne National Laboratory (Argonne) to evaluate future climate risks to ComEd’s infrastructure and operations. ComEd recognizes that its position as the state of Illinois’ largest electric utility, serving roughly 70% of the state’s population, underscores the importance for communities across Illinois to consider climate risk as they plan for future conditions. Climate impacts, such as more severe heatwaves or more frequent flood events, can disrupt the generation, transmission, and distribution of electricity and create public health challenges. Taking a proactive approach to adapt to climate risks will help ensure that ComEd continues to serve its growing customer-base reliably and efficiently. This Climate Risk and Adaptation Outlook serves as an important first step to inform ComEd’s grid planning efforts, but Argonne and ComEd recognize that additional research beyond this report will be necessary to characterize future climate conditions more comprehensively throughout northern Illinois, to assess their impacts to grid assets and system operations, and to index effective adaptation options at an asset-level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A method to observe field-region oxide charge and inter-electrode isolation from CV-characteristics of n-on-p devices

Abstract N-on-psilicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditionalp-on-nsensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO 2 -passivatedn-on-psensors is the generation of an inversion layer under the Si/SiO 2 -interface by a positive interface-oxide-charge (N ox ) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolnts (p-stp,p-spray) between n + -electrodes. Focusing on the guard-ring regions ofn-on-psensors where no isolation implants are applied between the electrodes, a capacitance-voltage (CV) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage (V th,iso ) in theCV-characteristics of a biased n + -electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measuredV th,iso was found to contain information on the field-regionN ox and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiatedn-on-psensors, the results indicate that position sensitiven-on-psensors without isolation implants may be feasible in future HEP experiments.

Instruments & Instrumentation↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Environmental influence on cracking and debonding of electrically conductive adhesives

Electrically conductive adhesives (ECAs) are starting to replace metallic solders in recent designs of photovoltaic (PV) modules. This transition represents a significant material change, and a proper understanding of the durability and reliability of the new interconnect needs to be established. This paper presents our continued work on developing a degradation model for ECA interconnects in PV modules. Here, we characterize the fracture mechanics properties of an epoxy-based ECA, for both critical and subcritical, mode I and mode II loading conditions. Emphasis is on the influence of different environmental conditions such as temperature and humidity. We use the Finite Element Method to account for residual stresses, induced by temperature changes and moisture absorption, and correct the apparent fracture toughness. We found that high moisture levels not only can weaken the fracture resistance of the ECA interconnect, but can also promote subcritical debonding at significantly lower driving forces than in dry environments.

42 ENGINEERING↗

Physical signatures of fermion-coupled axion dark matter

In the presence of axion dark matter, fermion spins experience an “axion wind” torque and an “axioelectric” force. We investigate new experimental probes of these effects and find that magnetized analogs of multilayer dielectric haloscopes can explore orders of magnitude of new parameter space for the axion-electron coupling. We also revisit the calculation of axion absorption into in-medium excitations, showing that axioelectric absorption is screened in spin-polarized targets, and axion wind absorption can be characterized in terms of a magnetic energy loss function. Finally, our detailed theoretical treatment allows us to critically examine recent claims in the literature. We find that axioelectric corrections to electronic energy levels are smaller than previously estimated and that the purported electron electric dipole moment due to a constant axion field is entirely spurious.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Introductory guide to the application of XPS to epitaxial films and heterostructures

XPS is an important characterization method for epitaxial films and heterostructures. Although standard approaches to XPS data collection and analysis provide useful information such as average composition and the presence of contaminants, more in-depth analysis provides information about film structure, surface termination, built-in electric potentials and band offsets. The high degree of structural order in these materials enables such information to be extracted from spectral data but also adds complications to the analysis. This guide highlights three topics of importance in this field: i) the impacts of crystallinity on XPS signals and quantification, ii) the unexpected spectral line shapes that can occur in unusual or novel materials, and, iii) the ability of XPS to yield information about built-in potentials and band offsets. Concepts are demonstrated using complex oxide heterostructures. Although the topics are highly relevant to epitaxial films and heterostructures, they also apply to signal crystals of complex materials

97 MATHEMATICS AND COMPUTING↗

Surface Oxidation Behavior of FeNi-based Metal Amorphous Nanocomposite (MANC) Alloys for High-Speed Motor Applications

New interest in high performance soft magnetic materials (SMMs) have been fueled by the need to lower losses at higher operating frequencies while maintaining high flux density and tunable permeability in electrical motors, transformer, and generator applications. Conventional SMMs like electrical steels and Fe-based metal amorphous nanocomposite (MANC) alloys are dominated by eddy current losses at high frequencies. Recent breakthrough in high-performance FeNi MANC have shown promise in reducing eddy current losses as compared to electrical steels. Their intrinsic adherent native surface oxide layer provides sufficient electrical insulation to reduce interlaminate eddy current losses. However, notwithstanding advances in MANCs, there exists a gap in literature on investigations of the surface oxide layer responsible for significant reduction of interlaminate eddy current losses in magnetic cores. This work presents a detailed characterization of the surface oxide, oxidation behavior, and relationship between oxide thickness and resistivity of a new FeNi MANC alloy (Fe70Ni30)80Nb4B14Si2.

Egbu, James↗

Thin-Entrance Window Process for Soft X-Ray Sensors

New free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250 eV to 1.5 KeV. Achieving adequately shallow entrance windows is challenging because the high temperature anneal needed to activate the dopant also drives the dopant profile deeper, growing the region that is insensitive to soft x-rays. A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. The microwave anneal technique can activate dopants at low substrate temperature, with minimal dopant diffusion, and can be used to fabricate both n-type and p-type entrance windows. SRP and SIMS measurements were used to verify dopant activation with negligible dopant diffusion. We then applied the microwave anneal process to a planar sensor wafer, using the new process to create the backside diode contact. Electrical test of the resulting sensors shows good reverse bias characteristics. The sensors have been bump-bonded to a read-out ASIC and used successfully to measure an Fe-55 x-ray spectrum. Process and device simulations were performed to characterize the quantum efficiency of the entrance window for soft x-rays. This technique is useful for other sensor applications requiring a shallow entrance window, including detectors for UV photons, low energy ions and low energy electrons.

47 OTHER INSTRUMENTATION↗

Effects of fiber dosage, loading orientation and stress on frequency response of enhanced Carbon Nano-Fiber Aggregates

Nanomaterial additives have been broadly used in cement and concrete-based sensors to measure the stress and strain in the structure. Most of the studies focused on measuring the resistivity of sensors with Direct Current (DC) or relatively low-frequency. Here in this work, the impedance responses of enhanced Carbon Nano-Fiber Aggregates (CNFAs) at different frequencies are rigorously studied and utilized as a tool for real-time structural health monitoring (SHM). The CNFA impedance measurements at different measurement frequencies provide an extra dimension (frequency dimension) to allow the characterization of different phenomena and multimodal measurements simultaneously. First, a comprehensive physical model is established to understand the frequency responses of the CNFA impedance. Second, COMSOL Multiphysics is used to simulate the frequency responses of the CNFA impedance, which provides more insights into the electric field and current density distribution. The impedance of CNFAs decreased with the increased dosage of carbon nanofibers (CNFs). Third, experimental studies are reported in detail. The electrical impedance variation (EZV) of the CNFA in parallel orientation is 151% higher than that of perpendicular orientation at the frequency of 2612 Hz and uniaxial compression stress of 4.65 MPa. The strain-EZV curve obtained from the response spectrum is linear for frequencies ranging from 98 Hz to 463.9 kHz. The strain-EZV curve for 5625 Hz has a linear fit with the gauge factor of 147.78. At 1000 Hz, the CNFA exhibited a repeatable behavior up to 9.35 MPa and detection limit up to the stress of 18.62 MPa.

36 MATERIALS SCIENCE↗

A study on sub-bandgap photoexcitation in nitrogen- and boron-doped diamond with interdigitated device structure

Diamond is an ultrawide-bandgap semiconductor suitable for high power devices that require high current carrying capacity, high blocking voltages, and smaller form factors. We investigated various diamond structures for extrinsic photoconductive semiconductor switches, including an insulating high-pressure high-temperature type Ib (highly nitrogen-doped) substrate, a chemical vapor deposited (CVD) type IIa (unintentionally doped) substrate, a CVD grown semiconducting boron-doped epilayer on a type IIa substrate, and boron-implanted type Ib and IIa substrates. Using these samples, we fabricated and characterized planar interdigitated photoconductive switches with 30 μm, electrode gaps. 532 and 1064 nm Nd:YAG laser pulses with energies up to 3.5 mJ/pulse were used to trigger the switches. Photoresponses were measured at bias voltages ranging from 10 to 100 V, corresponding to electric fields of 3.3–33 kV/cm. In this field range, the type Ib device exhibited the highest average on/off-state current ratio, on the order of 10 11 , when triggered with 0.8 mJ/pulse, 532 nm laser pulses. However, only the CVD grown boron-doped epilayer and boron implanted IIa devices showed decent sensitivity to 1064 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalous vortex liquid in charge-ordered cuprate superconductors

The interplay between charge order and d-wave superconductivity in high-T c cuprates remains an open question. While mounting evidence from spectroscopic probes indicates that charge order competes with superconductivity, to date little is known about the impact of charge order on charge transport in the mixed state, when vortices are present. Here we study the low-temperature electrical resistivity of three distinctly different cuprate families under intense magnetic fields, over a broad range of hole doping and current excitations. We find that the electronic transport in the doping regime where long-range charge order is known to be present is characterized by a nonohmic resistivity, the identifying feature of an anomalous vortex liquid. The field and temperature range in which this nonohmic behavior occurs indicates that the presence of long-range charge order is closely related to the emergence of this anomalous vortex liquid, near a vortex solid boundary that is defined by the excitation current in the T→0 limit. Our findings further suggest that this anomalous vortex liquid, a manifestation of fragile superconductivity with a suppressed critical current density, is ubiquitous in the high-field state of charge-ordered cuprates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Boosting the External Quantum Efficiency of AlGaN-Based Metal–Semiconductor–Metal Ultraviolet Photodiodes by Electrode Geometry Variation

Fast aluminum-gallium-nitride–based metal–semiconductor–metal ultraviolet photodiodes were successfully designed, fabricated, and characterized using conventional photolithography techniques. Various electrode geometries were fabricated to investigate the influence of metal contact shapes on the device performance indices with emphasis on the response speed and bias-voltage–independent efficiency. Furthermore, based on the independently measured Hall mobility and electric field, we evaluated the carrier transit time of the devices as 1.31 ps with bias-voltage–independent external quantum efficiency of 1198% in photoconductive mode at 19.5 V and 70% at 60 V for n -doped and intrinsic devices, respectively.

42 ENGINEERING↗