Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Analyzing the Effects of Cyberattacks on Distribution System State Estimation

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyberattacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyberattack scenarios on matrix completion. Realistic cyberattack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Grid Value Investigation of Medium-Voltage Back-to-Back Converters

This paper presents the results of an investigation into the value that medium voltage back-to-back (MVB2B) converters can be realized through two potential applications: voltage regulation via the provision of reactive power supply or absorption, and distributed energy resource (DER) hosting capacity improvement via the controlled transfer of real power within the distribution system. Two groups of distribution systems have been prepared for the value investigation: the IEEE 123-bus system for the voltage regulation study and two utility-provided, realistic distribution systems for the DER hosting capacity improvement study. The results demonstrate that the MVB2B converter can realize significant value for the grid through these two applications. In particular, with the MVB2B converter transferring power between two feeders, DER-based power can be routed to nearby loads instead of feed through the distribution substation. Additionally, the size of energy storage elements used to enable higher levels of DERs can be significantly reduced.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Probabilistic Resilience of DER Systems - A Simulation Assisted Optimization Approach

Energy systems resilience is becoming increasingly important as the frequency of major grid outages increases. In this work, we present a methodology to optimize a behind-tlie-meter distributed energy resource system to sustain a site's critical loads during a pre-defined outage period. With the fixed system design, we then propose an outage simulation approach to estimate the resilience potential of the DER system to sustain loads beyond the fixed outage period - a yearlong resilience performance analysis. We apply statistical analysis to assess the system's resilience performance over a broader parametric problem space on an hourly, monthly, and yearly basis. We demonstrate the impact of the pre-defined outage period on the resilience performance through a case study. Results show that the probability of surviving a random outage of a given duration changes from 20% to 95% when the outage is modeled for a weekday instead of a weekend for the given load-profile.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Isolating p- and n-Doped Fingers With Intrinsic Poly-Si in Passivated Interdigitated Back Contact Silicon Solar Cells

Polycrystalline silicon on silicon oxide (poly-Si/SiO x ) passivating contacts enable ultra high efficiency interdigitated back contact silicon solar cells. To prevent shunt between n- and p-type doped fingers, an insulating region is required between them. We evaluate the use of intrinsic poly Si for this isolation region. Interdigitated fingers were formed by plasma deposition of doped hydrogenated amorphous silicon through mechanically aligned shadow masks, on top of a full-area intrinsic amorphous silicon layer. High temperature annealing then crystallized the a-Si:H to poly Si and drove in the dopants. Two mechanisms were identified which cause contamination of the intrinsic poly Si gap during processing. During deposition of doped fingers, we show using secondary ion mass spectrometry and conductivity measurements that the intrinsic gap becomes contaminated by doped a-Si:H tails several nanometers thick to concentrations of ~10 20 cm -3 . Another source of contamination occurs during high-temperature annealing, where dopants desorb from doped regions and readsorb onto intrinsic a Si:H. Both pathways reduce the resistivity of the intrinsic gap from ~10 5 Ω·cm to ~10 -1 Ω·cm. We show that plasma etching of the a-Si:H surface before crystallizing with a capping layer can eliminate the contamination of the intrinsic poly-Si, maintaining a resistivity of ~10 5 Ω·cm. Lastly, this demonstrates masked plasma deposition as a dopant patterning method for Si solar cells.

14 SOLAR ENERGY↗

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own. While the integration issues span numerous timescales (from microseconds to many months), this article focuses on reliability and stability challenges on short timescales (microseconds to seconds). In other words, we seek to answer (to the extent that it is currently known) how to ensure the frequency and voltage stability in an island power system with very high instantaneous levels of wind and PVs. And because island power systems are often among the first to reach these very high instantaneous levels of wind and PV generation, we note that they are forging a path for larger interconnected power systems to follow.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Economic Comparison Between Battery and Supercapacitor for Hourly Dispatching Wave Energy Converter Power

This paper demonstrates a dispatching scheme of slider-crank wave energy converter (WEC) power generation using two different kinds of energy storage components, namely, Lithium-ion (Li-ion) battery and Supercapacitors (SC). The performance of the two energy storage components has been compared in order to develop the most economical energy storage system for WEC hourly dispatching scheme. The cost optimization of the energy storage system considering both cycling and calendar aging expenses is made based on its usage of depth of discharge. In this study, extensive simulation is conducted in MATLAB/Simulink platform, and it is found that SC is a better solution than Li-ion battery in terms of economic assessment for hourly dispatching WEC power.

50 EE - Wind and Water Power Program - Water (EE-4↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Practical Operations of Energy Storage Providing Ancillary Services: From Day-Ahead to Real-Time

As renewable resources are increasingly penetrating power systems, energy storage systems (ESSs) become essential in providing both energy arbitrage and ancillary services. Because of its high flexibility, ESSs have been taken into account in the daily operation of the bulk power system in many places. This paper proposes a general framework in the current electricity market environment to help system operators model the participation of multi-type ESSs and evaluate the performance of both energy arbitrage and reserve provision. We discuss different levels of ESSs' flexibility in providing ancillary services and also consider a deliberate and practical implementation of the modeling. This framework can be seamlessly integrated into the daily market operation without sacrificing computational efficiency. Numerical experiments validate the efficacy of the proposed framework and show that ESSs possess excellent potential in providing ancillary services for the bulk power system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluation of Curtailment Associated with PV System Design Considerations

Distributed photovoltaic (PV) systems equipped with advanced inverters can control real and reactive power output based on grid and atmospheric conditions. The Volt-Var control method allows inverters to regulate local grid voltages by producing or consuming reactive power. Based on their power ratings, the inverters may need to curtail real power to meet the reactive power requirements, which decreases their total energy production. To evaluate the expected curtailment associated with Volt-Var control, yearlong quasi-static time-series (QSTS) simulations were conducted on a realistic distribution feeder under a variety of PV system design considerations. Overall, this paper found that the amount of curtailed energy is low (<; 0.55%) compared to the total PV energy production in a year but is affected by several PV system design considerations.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Performance Evaluation of Data-Enhanced Hierarchical Control for Grid Operations

This paper presents a hardware-in-the-loop (HIL) simulation to evaluate the performance of voltage regulation of Data-Enhanced Hierarchical Control (DEHC). This DEHC uses an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results demonstrate functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues such as instability for field deployment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Multi-Function AAA Algorithm Applied to Frequency Dependent Line Modeling

Modeling of power distribution system components that are valid for a wide range of frequencies are crucial for highly accurate modeling of electromagnetic transient (EMT) events. This has recently become of interest due to the improvements needed for the resilient operation of distribution systems. Vector fitting (VF) is a very popular and commonly used algorithm for wide band representations of power system components in EMT simulations. In this research, we present a new multi-input rational approximation algorithm (MIAAA) and illustrate its advantages with respect to VF using examples of approximations of admittance matrices discussed in the literature. We show that MIAAA not only outperforms VF in terms of achieving better accuracy using lesser number of poles, but also has no numerical issues achieving convergence. In contrast to VF, MIAAA is not sensitive to the location of input sample points and it does not require good estimates for the location of the desired approximation poles. The novelty of this research work is the use of recent mathematical results to solve existing challenges in distribution system modeling and to develop rational approximations for power system models that intend to be optimal in terms of accuracy and performance.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid

Legacy energy management systems for distribution system or microgrids are typically driven by economics. During extreme events, resiliency can be defined as ability of the system to keep supplying critical loads. Resilient operation during extreme events (e.g. avalanche in Alaska) may require decision variables to be different and conflicting with economic operation. Operational objectives are driven by a complex consideration of the economic, reliable and resilient operation of the system: economic and reliable in normal operating state and resilient during extreme events. Challenge is to move between economic and resilient operation in optimal manner and setting up problem formulation and constraints specially with Distributed Energy Resources (DERs). In this paper, we focus on striking a balance between optimal economic and resilient operation using novel formulation and developed tool called Resiliency Enabled Energy System Operation Toolbox (RE-ESOT). Simulation results are provided for a real islanded grid in Alaska with battery energy systems.

50 EE - Wind and Water Power Program - Water (EE-4↗

Dynamic Modeling of Full Converter Adjustable-speed Pumped Storage Hydropower (FC AS-PSH)

Full converter adjustable-speed pumped storage hydropower (FC AS-PSH) technology, as one of advanced-PSH technology, is developed from wind turbine technology. By making the synchronous machine connect to the grid through a full-size converter, FC AS-PSH has a wider adjustment range of speed and a better reactive power control capability compared with a doubly-fed asynchronous generator AS-PSH technology. When it plays as an energy backup in the power system, FC AS-PSH can provide a much faster response than conventional-PSH (C-PSH) which makes this technology provide better ancillary service for a high renewable penetrated system. In this paper, the dynamic modeling of FC AS-PSH is fully studied. We develop a detailed model of this technology in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform. Especially, the first governor model is developed based on the Engineer’s Program Control Language (EPCL) user-defined model in this platform. All operation modes are validated and studied under a system contingency. Besides, comparison cases between FC AS-PSH and C-PSH are studied to show advantages providing from FC AS-PSH when it works with renewable energy.

50 EE - Wind and Water Power Program - Water (EE-4↗

Blackstart of Power Grids with Inverter-Based Resources

This paper presents the findings of our investigation into inverter-based resource-(IBR-) driven blackstart of electric grids. Four potential black-start configurations with different setups are presented. To evaluate the technical feasibility of IBR-driven black start in the four configurations, a behavioral model of inverters that mimics current-limited inverter operation is developed using variable resistors in the MATLAB Simulink/Simscape environment. The inverter model is connected to an induction motor through transformers and a transmission line to simulate its startup. Simulation results show that even with the limited current supply capability of inverters because of their physical constraints, IBRs can black-start a motor under certain conditions. Results also show that by using soft-start techniques, such as ramped supply voltage, inrush currents can be reduced, thereby expanding the conditions under which IBRs can provide black-start support. Simulation results with different scenarios lead to discussions and key takeaways that could be valuable for further IBR-driven black-start research.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Fault Response of Distributed Energy Resources Considering the Requirements of IEEE 1547-2018

Inverter-based DER responses to faults on the electric power system are different than those of conventional generators and are often poorly understood. Inverter fault responses are largely software-defined, within physics-based constraints. DERs are regulated by standards and grid codes that also constrain their responses. Though fault response of DERs will vary widely, for any DER following any particular standard, a pattern of fault response can be synthesized by observing that particular standard. In this paper, the recently published IEEE 1547-2018 is examined to explore the general fault response of any DER that follows IEEE 1547-2018. Additionally, an IEEE 1547-2018 compliant inverter model is developed and tested in simulation to find the fault response, and that response is compared with the fault response of a commercial off-the-shelf inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Synthesis of CdSeCdSexTe1-x/CdTe for Graded Solar Cells

Here, we have developed CdSe x Te 1-x /CdTe bilayer deposition for graded solar cell technology. Smoothly graded Se profiles with > 16% efficiency with Jsc=28 m A/cm 2 and 20-ns bulk lifetime has been observed observed. The CdSeTe reveals longer carrier lifetimes than CdTe within the same device.

41 EE - Solar Energy Technologies Office (EE-4S)↗