Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic polymer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Phase-Imaging with a Sharpened Multi-Walled Carbon Nanotube AFM Tip: Investigation of Low-k Dielectric Polymer Hybrids

Phase shift tapping mode scanning force microscopy (TMSFM) has evolved into a very powerful technique for the nanoscale surface characterization of compositional variations in heterogeneous samples. Phase shift signal measures the difference between the phase angle of the excitation signal and the phase angle of the cantilever response. The signal correlates to the tip-sample inelastic interactions, identifying the different chemical and/or physical property of surfaces. In general, the resolution and quality of scanning probe microscopic images are highly dependent on the size of the scanning probe tip. In improving AFM tip technology, we recently developed a technique for sharpening the tip of a multi-walled carbon nanotube (CNT) AFM tip, reducing the radius of curvature of the CNT tip to less than 5 nm while still maintaining the inherent stability of multi-walled CNT tips. Herein we report the use of sharpened (CNT) AFM tips for phase-imaging of polymer hybrids, a precursor for generating nanoporous low-k dielectrics for on-chip interconnect applications. Using sharpened CNT tips, we obtained phase-contrast images having domains less than 10 nm. In contrast, conventional Si tips and unsharpened CNT tips (radius greater than 15 nm) were not able to resolve the nanoscale domains in the polymer hybrid films. C1early, the size of the CNT tip contributes significantly to the resolution of phase-contrast imaging. In addition, a study on the nonlinear tapping dynamics of the multi-walled CNT tip indicates that the multi-walled CNT tip is immune to conventional imaging instabilities related to the coexistence of attractive and repulsive tapping regimes. This factor may also contribute to the phase-contrast image quality of multi-walled CNT AFM tips. This presentation will also offer data in support of the stability of the CNT tip for phase shift TMSFM.

Nguyen, Cattien V.↗

Probing single-chain conformation and its impact on the optoelectronic properties of donor–accepter conjugated polymers

The chain conformation of donor–acceptor conjugated polymers (D–A CPs) is critical to their optical and electronic properties. However, probing the conformation of D–A CPs (e.g., persistence length and contour length) at a single-chain level is challenging due to the formation of aggregates in dilute solution, even in a good solvent. In this work, we studied the chain conformation and corresponding optical spectra for high-performance D–A CPs in the single-chain state by multimodal variable-temperature scattering and spectroscopy techniques, as well as by molecular dynamics simulations. Here we found a critical role of the side-chain length and branch point in the persistence length and optical absorption due to steric effects. Hence, it is important to consider both the chain rigidity and coplanarity of the polymer backbone to achieve desirable optoelectronic properties. Our findings bridge the fundamental knowledge gaps to design new CPs with desired optoelectronic properties via molecular engineering for next-generation electronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly stretchable ionically crosslinked acrylate elastomers inspired by polyelectrolyte complexes

Dynamic bonds are a powerful approach to tailor the mechanical properties of elastomers and introduce shape-memory, self-healing, and recyclability. Among the library of dynamic crosslinks, electrostatic interactions among oppositely charged ions have been shown to enable tough and resilient elastomers and hydrogels. In this work, we investigate the mechanical properties of ionically crosslinked ethyl acrylate-based elastomers assembled from oppositely charged copolymers. Using both infrared and Raman spectroscopy, we confirm that ionic interactions are established among polymer chains. We find that the glass transition temperature of the complex is in between the two individual copolymers, while the complex demonstrates higher stiffness and more recovery, indicating that ionic bonds can strengthen and enhance recovery of these elastomers. We compare cycles to increasing strain levels at different strain rates, and hypothesize that at fast strain rates ionic bonds dynamically break and reform while entanglements do not have time to slip, and at slow strain rates ionic interactions are disrupted and these entanglements slip significantly. Further, we show that a higher ionic to neutral monomer ratio can increase the stiffness, but its effect on recovery is minimal. Lastly, taking advantage of the versatility of acrylates, ethyl acrylate is replaced with the more hydrophilic 2-hydroxyethyl acrylate, and the latter is shown to exhibit better recovery and self-healing at a cost of stiffness and strength. The design principles uncovered for these easy-to-manufacture polyelectrolyte complex-inspired bulk materials can be broadly applied to tailor elastomer stiffness, strength, inelastic recovery, and self-healing for various applications.

36 MATERIALS SCIENCE↗

Source of Processable Vitrimer Viscosities: Swap Frequencies and Steric Factors

Vitrimers exhibit high, processable viscosities, where other polymers do not, and are among the most promising polymers for closed-loop material circularity. We sought to investigate the underlying chemical kinetic factors that result in high viscosities for vitrimers, which are crucial to designing vitrimers with tunable viscosity. To interrogate these factors, we achieved the first simulated predictions of real vitrimer viscosities, using a novel kinetic Monte Carlo molecular dynamics method, overcoming the time and length scale gaps to predict experimental bulk viscosities. The vitrimer architecture investigated is based on poly(dimethylsiloxane) chains and vinylogous urethane bond swaps. We probed the effects of the extent of free swapping groups, %F, the activation energy, E A , and the steric factor, ρ. The steric factor is related to the intrinsic reaction probability for molecules with sufficient energy. All three factors were found to be significant, but the role of ρ was found to be the biggest and also the most underappreciated. The results show that the inclusion of accurate ρ is of critical importance for viscosity predictions, with the evidence suggesting that the typical assumption of ρ = 1 is not valid for vitrimers and that, indeed, very low steric factors are present in bond-swap vitrimers such that values of ρ < 10 –10 may be typical. This greatly influences the bond exchange rates and, ultimately, the viscosities. Recognition of this result is necessary for the prediction of vitrimer viscosities from molecular simulations and to make vitrimers by design from molecular dynamics. We also investigated the effects that E A , ρ, and the number of free swapping groups have upon vitreous range temperatures, TV, with respect to achieving a specific viscosity (η V = 1 × 10 8 Pa·s), as well as for a commonly reported higher viscosity extrapolation (η V = 1 × 10 12 Pa·s). The evidence suggests that vitrimers may follow universal curves for E A vs T V , as a function of ρ. Finally, this study achieves the first of these comparisons of molecular simulations to experiments and reveals critical insights toward creating vitrimers by design, while providing a route for the prediction of T V from kinetic Monte Carlo molecular dynamics simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CHARMM-GUI Nanomaterial Modeler for Modeling and Simulation of Nanomaterial Systems

Molecular modeling and simulation are invaluable tools for nanoscience that predict mechanical, physicochemical, and thermodynamic properties of nanomaterials and provide molecular-level insight into underlying mechanisms. However, building nanomaterial-containing systems remains challenging due to the lack of reliable and integrated cyberinfrastructures. Here we present Nanomaterial Modeler in CHARMM-GUI, a web-based cyberinfrastructure that provides an automated process to generate various nanomaterial models, associated topologies, and configuration files to perform state-of- the-art molecular dynamics simulations using most simulation packages. The nanomaterial models are based on the interface force field, one of the most reliable force fields (FFs). The transferability of nanomaterial models among the simulation programs was assessed by single-point energy calculations, which yielded 0.01% relative absolute energy differences for various surface models and equilibrium nanoparticle shapes. Three widely used Lennard-Jones (LJ) cutoff methods are employed to evaluate the compatibility of nanomaterial models with respect to conventional biomolecular FFs: simple truncation at r = 12 Å (12 cutoff), force-based switching over 10 to 12 Å (10-12 fsw), and LJ particle mesh Ewald with no cutoff (LJPME). The FF parameters with these LJ cutoff methods are extensively validated by reproducing structural, interfacial, and mechanical properties. As a result, we find that the computed density and surface energies are in good agreement with reported experimental results, although the simulation results increase in the following order: 10-12 fsw <12 cutoff < LJPME. Nanomaterials in which LJ interactions are a major component show relatively higher deviations (up to 4% in density and 8% in surface energy differences) compared with the experiment. Nanomaterial Modeler's capability is also demonstrated by generating complex systems of nanomaterial-biomolecule and nanomaterial-polymer interfaces with a combination of existing CHARMM-GUI modules. We hope that Nanomaterial Modeler can be used to carry out innovative nanomaterial modeling and simulations to acquire insight into the structure, dynamics, and underlying mechanisms of complex nanomaterial-containing systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Reflectometry Reveals Diffusion in Contrast-Matched Brush Particle Bilayers

A material system for performing layer-spread experiments on brush particle bilayers is presented and used to determine the diffusion constant of brush particles in the melt state. Selective deuteration of the core and shell of organo-silica nanoparticles grafted with poly(methyl methacrylate) was used to match the scattering length density of the core and the polymer canopy layer. This subdued the scattering of particle cores (i.e., formfactor scattering) and enabled the analysis of the interdiffusion kinetics using neutron reflectivity. For low molecular grafts, i.e., grafts with a molecular weight below the entanglement limit, the interdiffusion kinetics revealed both a sub- and Fickian diffusion regime. The former was attributed to the local dynamics that was constrained by the slow-moving cores of neighboring brush particles that acted as long-lived physical cross-links. No transition to Fickian diffusion was observed for entangled systems, even at prolonged annealing times. This suggested a higher level of kinetic restraint in entangled brush particle melts as compared to, for example, star polymers with a comparable chain length for which Fickian diffusion has been reported under similar conditions.

Diffusion, Polymer Grafted Nanoparticles, Neutron ↗

Loss circulation prevention in geothermal drilling by shape memory polymer

Geothermal formations are naturally fractured with large fracture openings and networks. This can often lead to frequent drilling fluid loss events which is a major contributor to the cost and non-productive time in geothermal drilling. Development of smarter technologies and methods to tackle problem lost circulation is vital for geothermal drilling cost reduction required for geothermal energy to be recognized as a competitive alternative energy source. Mitigation of this problem and other drilling problems such as stuck pipe can minimize overall project cost. In this report, a thermoset shape memory polymer that can be activated by formation natural heat was assessed to seal near wellbore fractures in geothermal wells. The performance of the shape memory polymer (SMP) was evaluated using artificial fractures created in aluminum discs and cylindrical granite cores. Rheology and particle size distribution were considered. A novel testing setup was built for this work, which allows testing of sealing efficiency under dynamic conditions at high temperature. Analysis showed that the SMP has efficiently succeeded in forming a strong plug inside the fractures and stopped fluid loss at high sealing pressure. This smart loss circulation material can expand within the fractures to reduces non-drilling time and strengthen the wellbore in high-temperature drilling operations.

58 GEOSCIENCES↗

Dynamic Networks for On Demand Degradable Adhesives, Scaffolds and Templates (Abbreviated Final Report)

This feasibility study was motivated by a need for alternative mandrel materials to meet the next generation of inertial confinement fusion (ICF) ablator capsules. In response, a new polymer material based on reversible covalent bonds was proposed, with the objective to design thermosets to withstand elevated temperatures (140-200 degrees Celsius) while also being thermally degradable on-demand via controlled decomposition at temperatures above 200 degrees Celsius. A series of cyclopentadiene (Cp) containing thermosets were designed and synthesized to evaluate curing, reversibility and degradability controlled via retro-Diels Alder reactions using Cp-cycloaddition adducts as crosslinks. Ultimately, the current iteration of materials and strategy pursued in this study was assessed as impractical for meeting the needs and objectives of Lawrence Livermore National Laboratory’s (LLNL) target fabrication program.

36 MATERIALS SCIENCE↗

The charge reduction rate for multiply charged polymer ions via ion–ion recombination at atmospheric pressure

The charge reduction of multiply charged macromolecular ions via recombination with small ions in the gas phase is commonly employed to modulate the charge on macromolecules prior to mass spectrometric and mobility analyses. We employ a recently developed continuum-Molecular Dynamics (MD) calculation approach to determine the recombination rate coefficient of multiply charged (1 to 7 excess positive charged) polyethylene glycol ions (mass of 4600 Da) with smaller singly charged anions, modeled as NO 2 – ions. The continuum-MD approach accounts explicitly for the influence of the background gas on the recombination process, accounts explicitly for ion translational, vibrational, and rotational motion, and enables recombination rate coefficient calculation in nitrogen near atmospheric pressure, wherein neither low pressure nor high pressure recombination theories are strictly applicable. Continuum-MD simulations yield recombination rate coefficients near 3.9 × 10 –14 m 3 s –1 for singly charged ions, increasing to 3.0 × 10 –11 m 3 s –1 for the +7 ion. Pre-existing collision rate coefficient expressions for rigid ions are found to be within a factor of 2–5 of calculations for all charge states, but their use requires knowledge of an appropriate collision distance, which is not well-defined for flexible polymer ions. Continuum-MD-inferred rate coefficients are incorporated into a model of charge reduction, and the charge state distribution versus anion concentration determined with it is compared to charge reduction measurements made via atmospheric pressure differential mobility analysis. Furthermore, good agreement is observed between simulations and experiments; although results are extremely sensitive to the recombination rate coefficients, experimental results are bound by models utilizing rates within a factor of 2 (0.5–2.0×) of the continuum-MD rates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Accurate Calculation of Solvation Properties of Lithium Ions in Nonaqueous Solutions

Here, we perform all-atom molecular dynamics simulations of lithium triflate in 1,2-dimethoxyethane using six different literature force fields. This system is representative of many experimental studies of lithium salts in solvents and polymers. We show that multiple historically common force fields for lithium ions give qualitatively incorrect results when compared with those from experiments and quantum chemistry calculations. We illustrate the importance of correctly selecting force field parameters and give recommendations on the force field choice for lithium electrolyte applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Simulations of CH 4 and CO 2 Diffusion in Rigid Nanoporous Amorphous Materials

Molecular diffusion in nanoporous materials is important in determining the rate of equilibration of various adsorption processes and plays a pivotal role in kinetic separations and membrane-based separations. Because generating realistic structures of amorphous nanoporous materials is difficult, far less is known about diffusion in amorphous nanoporous materials than in their crystalline counterparts. Here, we present molecular dynamics simulations assessing the room-temperature self-diffusion of CH 4 and CO 2 in a wide range of rigid amorphous nanoporous materials, including porous carbons, kerogens, polymers of intrinsic microporosity, and hyper-cross-linked polymers. Our results are the largest collection of molecular diffusivities in amorphous nanoporous materials to date. In each material, the diffusivity increases with the adsorbate concentration at low and moderate adsorbate concentrations, reaching a maximum before decreasing due to steric effects at higher concentrations. The observed diffusivities are much slower than that would be expected based on standard descriptions of Knudsen diffusivity. Here we show that the observed diffusivities are not correlated in a simple way with scalar descriptors of the pore structures such as the pore limiting diameter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Moisture-induced autonomous surface potential oscillations for energy harvesting

A variety of autonomous oscillations in nature such as heartbeats and some biochemical reactions have been widely studied and utilized for applications in the fields of bioscience and engineering. Here, we report a unique phenomenon of moisture-induced electrical potential oscillations on polymers, poly([2-(methacryloyloxy)ethyl] dimethyl-(3-sulfopropyl) ammonium hydroxide-co-acrylic acid), during the diffusion of water molecules. Chemical reactions are modeled by kinetic simulations while system dynamic equations and the stability matrix are analyzed to show the chaotic nature of the system which oscillates with hidden attractors to induce the autonomous surface potential oscillation. Using moisture in the ambient environment as the activation source, this self-excited chemoelectrical reaction could have broad influences and usages in surface-reaction based devices and systems. As a proof-of-concept demonstration, an energy harvester is constructed and achieved the continuous energy production for more than 15,000 seconds with an energy density of 16.8 mJ/cm 2 . A 2-Volts output voltage has been produced to power a liquid crystal display toward practical applications with five energy harvesters connected in series.

42 ENGINEERING↗

Gas Sensor Evaluations in Polymer Combustion Product Atmospheres

Toxic gases produced by the combustion or thermo-oxidative degradation of materials such as wire insulation, foam, plastics, or electronic circuit boards in space shuttle or space station crew cabins may pose a significant hazard to the flight crew. Toxic gas sensors are routinely evaluated in pure gas standard mixtures, but the possible interferences from polymer combustion products are not routinely evaluated. The NASA White Sands Test Facility (WSTF) has developed a test system that provides atmospheres containing predetermined quantities of target gases combined with the coincidental combustion products of common spacecraft materials. The target gases are quantitated in real time by infrared (IR) spectroscopy and verified by grab samples. The sensor responses are recorded in real time and are compared to the IR and validation analyses. Target gases such as carbon monoxide, hydrogen cyanide, hydrogen chloride, and hydrogen fluoride can be generated by the combustion of poly(vinyl chloride), polyimide-fluoropolymer wire insulation, polyurethane foam, or electronic circuit board materials. The kinetics and product identifications for the combustion of the various materials were determined by thermogravimetric-IR spectroscopic studies. These data were then scaled to provide the required levels of target gases in the sensor evaluation system. Multisensor toxic gas monitors from two manufacturers were evaluated using this system. In general, the sensor responses satisfactorily tracked the real-time concentrations of toxic gases in a dynamic mixture. Interferences from a number of organic combustion products including acetaldehyde and bisphenol-A were minimal. Hydrogen bromide in the products of circuit board combustion registered as hydrogen chloride. The use of actual polymer combustion atmospheres for the evaluation of sensors can provide additional confidence in the reliability of the sensor response.

Delgado, Rafael H.↗

Fluorine-Free Precise Polymer Electrolyte for Efficient Proton Transport: Experiments and Simulations

Designing polymers with controlled nanoscale morphologies and scalable synthesis is of great interest in the development of fluorine-free materials for proton-exchange membranes in fuel cells. This study focuses on a precision polyethylene with phenylsulfonic acid branches at every fifth carbon, p5PhSA, with a high ion-exchange capacity (4.2 mmol/g). The polymers self-assemble into hydrophilic and hydrophobic co-continuous nanoscale domains. In the hydrated state, the hydrophilic domain, composed of polar sulfonic acid moieties and water, serves as a pathway for efficient mesoscopic proton conductivity. The morphology and proton transport of p5PhSA are evaluated under hydrated conditions using in situ X-ray scattering and electrochemical impedance spectroscopy techniques. Additionally, at 40 °C and 95% relative humidity, the proton conductivity of p5PhSA is 0.28 S/cm, which is four times greater than Nafion 117 under the same conditions. Atomistic molecular dynamics (MD) simulations are also used to elucidate the interplay between the structure and the water dynamics. The MD simulations show strong nanophase separation between the percolated hydrophilic and hydrophobic domains over a wide range of water contents. The percolated hydrophilic nanoscale domain facilitates the rapid proton transport in p5PhSA and demonstrates the potential of precise hydrocarbon-based polymers as processible and effective proton-exchange membranes.

36 MATERIALS SCIENCE↗

Thermo-mechanical deterioration and molecular degradation of 3D-printed methacrylate-based polymer in various chemical environments

The advancement of additive manufacturing (AM) has accelerated the development of stereolithographic (SLA) photo-curable resins, particularly methacrylate-based polymers, due to the ability to their high-resolution, robust mechanical properties, and suitability. However, their long-term performance in chemical environments remains poorly understood. This study investigates the extent and mechanisms of degradation on an SLA-printed methacrylate-based polymer subjected to various chemicals, including polar and non-polar solvents, as well as strongly acidic aqueous solutions over a 12-week accelerated aging period. A comprehensive analytical approach incorporating swelling kinetics, surface morphology, tensile and dynamic mechanical analysis (DMA), Fourier-transform infrared (FTIR) spectroscopy, and mass spectrometry (MS) was employed to characterize chemical absorption, structural integrity, and leached products. Results reveal that degradation severity is governed by both the polarity and reactivity of the chemical environment. Notably, exposure to 6 mol L -1 HNO₃ induced the most severe deterioration, with over threefold higher swelling compared to other media, and significant reductions in tensile strength, tensile modulus, and glass transition temperature (T g ). In contrast, specimens aged in non-polar solvents (xylene and dodecane) exhibited negligible chemical interaction and retained mechanical performance. FTIR and MS analyses identified acid-catalyzed hydrolysis of ester groups as prominent degradation pathways in acidic media, while diffusion-controlled plasticization prevailed in polar solvents. Furthermore, this study provides valuable insights into the chemical stability of SLA-printed polymers and develops predictive degradation profiles that are crucial for designing durable polymer systems for advanced industrial use.

36 MATERIALS SCIENCE↗

Trace explosive residue detection of HMX and RDX in post-detonation dust from an open-air environment

Explosives are often used in industry, geology, mining, and other applications, but it is not always clear what remains after a detonation or the fate and transport of any residual material. The goal of this study was to determine to what extent intact molecules of high explosive (HE) compounds are detectable and quantifiable from post-detonation dust and particulates in a field experiment with varied topography. We focused on HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazocane), which is less studied in field detonation literature, as the primary explosive material and RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) as the secondary material. The experiment was conducted at Site 300, Lawrence Livermore National Laboratory’s Experimental Test Site, in California, USA. Two 20.4 kg and one 40.8 kg above ground explosions (primarily comprised of LX-14, an HMX-based polymer-bonded high explosive) were detonated on an open-air firing area on separate days. The complex terrain of the firing area (e.g., buildings, berm, low-height obstacles) was advantageous to study HE deposition in relation to plume dynamics. Three types of samples were collected up to 100 m away from each shot: surface swipes of aluminum plates, surface swipes of fixed objects, and filters from air samples. We used atmospheric flow tube-mass spectrometry (AFT-MS) to quantify picogram levels of molecular residue of HE material in the post-detonation dust. An aliquot of sample extract in methanol (e.g., 1 µL of 0.5 mL) was placed onto a resistive material and then thermally desorbed into the AFT-MS. We successfully detected and quantified both HMX and RDX in many of the samples. Based on mass (pg) detected and solution dilution, we back-calculated the mass collected on the swipe or filter (ng per sample). The aerial distribution of molecular residue was consistent with the path of the plume, which was strongly determined by wind speed and direction at the time of each shot. The quantity of material detected appeared to correlate more with distance from the shot and the wind conditions than with shot size. This study demonstrates that the picogram detection levels of AFT-MS are well-suited for quantification of analytes (e.g., HMX and RDX) in environmental samples.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗