Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Saturn Magnetospheric Impact on Surface Molecular Chemistry and Astrobiological Potential of Enceladus

The active south polar surface of Enceladus is exposed to strong chemical processing by direct interaction with charged plasma and energetic particles in the local magnetospheric environment of this icy moon. Chemical oxidation activity is suggested by detection of H202 at the surface in this region and less directly by substantial presence of C02, CO, and N2 in the plume gases. Molecular composition of the uppermost surface, including ejecta from plume activity, is radiolytically transformed mostly by penetrating energetic electrons with lesser effects from more depleted populations of energetic protons. The main sources of molecular plasma ions and E-ring dust grains in the magnetospheric environment are the cryovolcanic plume emissions from Enceladus. These molecular ions and the dust grains are chemically processed by magnetospheric interactions that further impact surface chemistry on return to Enceladus. For example, H20 neutrals dominating the emitted plume gas return to the surface mostly as H30+ ions after magnetospheric processing. Surface oxidant loading is further increased by return of radiolytically processed ice grains from the E-ring. Plume frost deposition and micrometeoroid gardening protect some fraction of newly produced molecular species from destruction by further irradiation. The evident horizontal and vertical mobility of surface ices in the south polar region drive mixing of these processed materials into the moon interior with potential impacts on deep ice molecular chemistry and plume gas production. Similarly as suggested previously for Europa, the externally driven source of radiolytic oxidants could affect evolution of life in any subsurface liquid water environments of Enceladus.

Cooper, Paul D.↗

High pressure cosmochemistry applied to major planetary interiors: Experimental studies

The measurement of equilibria in binary fluid-solid systems in diamond anvil cells, represents a major advance of the art of high-pressure experimentation. Vibrational spectroscopy, direct visual observations, and X-ray diffraction crystallography of materials confined in externally heated cells are the primary experimental probes being used. Adiabats in these systems are being measured in order to constrain models of heat flow in these bodies and to detect phase transitions by thermal anomalies. Other studies are directed toward interpreting high pressure reactions in these systems that are suggested by shockwave measurements, and developing methods for reaching high temperatures and high pressures of planetary interest in diamond cells. The overall objective of this project is to determine the properties of the H2-He-H2O-HN3-CH4 system and related small-molecule systems that are needed to constrain theoretical models of the interiors of the major planets.

Nicol, M. F.↗

Infalling Planetesimals in Pre-Main Sequence Stellar Systems

These are exciting times in the study of planetary system formation with a steadily expanding inventory of exo-planet detections, and imaging of dust disks around nearby young and main sequence stars. While these discoveries imply that our Solar System is far from unique, linking the data for the protoplanetary and debris disks to mature planetary systems requires a demonstration that disk evolution proceeds via planetesimal production and growth to the formation of planets. Theoretical studies of planet formation indicate that planetesimals grow, via runaway accretion, to lunar-sized (approx. = 2000 km) embryos in 10(exp 5) years. Recent gas giant planet formation studies have suggested that most of the action in planet formation occurs over 1-16 Myr, with formation of planets similar to Jupiter in t less than 10 Myr, within the time interval that infrared (IR) and optical emission line studies have demonstrated that circumstellar material remains detectable around both solar mass and intermediate mass stars. Direct imaging of exo-planetesimals is not feasible with current and foreseeable technology, since such bodies have substantially less surface area than micron-sized grains distributed in a disk, and thus are inefficient IR emitters. However, such bodies may be indirectly detectable.

Grady, Carol A.↗

Integration of Dust Prediction Systems and Vegetation Phenology to Track Pollen for Asthma Alerts in Public Health

Initial efforts to develop a deterministic model for predicting and simulating pollen release and downwind concentration to study dependencies of phenology on meteorology will be discussed. The development of a real-time, rapid response pollen release and transport system as a component of the New Mexico Environmental Public Health Tracking System (EPHTS), is based on meteorological models, NASA Earth science results (ESR), and an in-situ network of phenology cameras. The plan is to detect pollen release verified using ground based atmospheric pollen sampling within a few hours using daily MODIS daa in nearly real-time from Direct Broadcast, similar to the MODIS Rapid Response System for fire detection. As MODIS winds down, the NPOESS-VIIRS sensor will assume daily vegetation monitoring tasks. Also, advancements in geostationary satellites will allow 1km vegetation indices at 15-30 minute intervals. The pollen module in EPHTS will be used to: (1) support public health decisions for asthma and allergy alerts in New Mexico, Texas and Oklahoma; (2) augment the Centers for Disease Control and Prevention (CDC)'s Environmental Public Health Tracking Network (EPHTN); and (3) extend surveillance services to local healthcare providers subscribing to the Syndrome Reporting Information System (SYRIS). Previous studies in NASA's public health applications portfolios provide the infrastructure for this effort. The team is confident that NASA and NOAA ESR data, combined into a verified and validated dust model will yield groundbreaking results using the modified dust model to transport pollen. The growing ESR/health infrastructure is based on results from a rapid prototype scoping effort for pollen detection and simulation carried out by the principal investigators.

Luvall, Jeffrey↗

Raman intensity as a probe of concentration near a crystal growing in solution

The feasibility of using Raman spectral scattering signals for measurements of concentration profiles near a crystal interface during growth or dissolution is discussed. With KH2PO4 (KDP) as a test material, optical multichannel analyzer (OMA) detection of a solute Raman vibrational band provided direct quantification of solute concentration with band intensity. The intersection of incident laser and Raman collection optics provided 3-D selective point measurements of the solution concentration field. Unlike many other techniques, the Raman band intensity is not sensitive to the typical temperature variations. Precision calibration of Raman intensity versus KDP concentration with less than 1 pct standard deviation error levels was demonstrated. A fiber optic, which sampled incident laser intensity and coupled it to the OMA, provided a fully synchronized monitor of fluctuations in laser power to correlate with observed Raman signals. With 1 W of laser power at the sample, good data statistics required eight repeated data collections at approximately 2.5 min collection. The accumulated time represents the concentration measurement time at one spatial location. Photomicroscopy documented a 30 micrometer diameter by 200 micrometer of laser Raman scattering region in the solution near the crystal surface. The laser beam was able to approach up to 25 micrometer from the crystal surface. However, a crystal surface reflected intensity contribution was weakly detectable. Nucleated microcrystals were seen in the crystal-growing solution. These microcrystals convect right up to the crystal surface and indicate no quiet diffusion region under normal gravity conditions. Translation of the solution cell with respect to the optics caused systematic intensity errors.

Wilkinson, R. Allen↗

The directivity of high-energy emission from solar flares - Solar Maximum Mission observations

The data base consisting of flares detected by the gamma-ray spectrometer (GRS) on board the Solar Maximum Mission (SMM) satellite is used to study the directivity of high-energy radiation. A number of observations are presented that, strongly indicate that the high-energy emission from flares is anisotropic. They are the following: (1) the fraction of events detected at energies above 300 keV near the limb is higher than is expected for isotropically emitting flares; (2) there is a statistically significant center-to-limb variation in the 300 keV to 1 MeV spectra of flares detected by the SMM GRS; (3) the 25-200 keV hard X-ray spectra measured during the impulsive phase by the SMM GRS show a center-to-limb variation; and (4) nearly all of the events detected at above 10 MeV are located near the limb.

Vestrand, W. Thomas↗

Miniature stress transducer has directional capability

Miniature stress transducer uses a semiconductive piezoresistive element to detect stress only on specific axes. Measurement of internal mass stress is based on the compressive deformation of the transducer. The device is applicable to constant stress monitoring in building and dam structural parts.

San Miguel, A.↗

Detection of acetylene in the Saturnian atmosphere, using the IUE satellite

Direct evidence for the presence of acetylene in the upper part of the Saturnian atmosphere is reported. This evidence consists of two spectra of Saturn obtained by using the low-dispersion mode of the short-wavelength spectrograph on the IUE satellite. A series of distinct absorption bands in the reflected solar radiation at 1750 A is attributed to acetylene. The reciprocal of the acetylene cross section at 1750 A is shown to imply 7 x 10 to the 17th molecules/sq cm in the reflecting layer. It is concluded that the radiation at 1750 A originates from less than 2.3 km-amagat within the atmosphere.

Moos, H. W.↗

Waves in frazil and pancake ice and their detection in Seasat synthetic aperture radar imagery

Measurements of wavelength and direction derived from SAR imagery obtained from Seasat in October 1987 are compared with a theoretical model of waves propagating into an ice cover composed of frazil and pancake ice. The dispersion relation for phase and group velocities is derived, and the existence of an upper frequency limit for propagation into the ice is found. The wave radiation pressure exerted on the ice is derived from the reflection coefficient at the ice edge; it is found to cause a slick of frazil ice backed by thicker floes to become more dense or thick with increasing penetration. When the frazil ice becomes transformed into pancake ice, the raised edges of the pancakes cause the ice to appear bright despite the fact that there are no waves present at the Bragg wavelength. Directional wave number spectra are derived outside and inside the ice cover. The change of wavelength and angle of refraction of the dominant wave entering the ice field are both found to be characteristic of the dispersion relation derived theoretically.

Wadhams, Peter↗

Direct Imaging of a Cold Jovian Exoplanet in Orbit around the Sun-Like Star GJ 504

Several exoplanets have recently been imaged at wide separations of >10 AU from their parent stars. These span a limited range of ages (<50 Myr) and atmospheric properties, with temperatures of 800-1800 K and very red colors (J −H > 0.5 mag), implying thick cloud covers. Furthermore, substantial model uncertainties exist at these young ages due to the unknown initial conditions at formation, which can lead to an order of magnitude of uncertainty in the modeled planet mass. Here, we report the direct imaging discovery of a Jovian exoplanet around the Sun-like star GJ 504, detected as part of the SEEDS survey. The system is older than all other known directly-imaged planets; as a result, its estimated mass remains in the planetary regime independent of uncertainties related to choices of initial conditions in the exoplanet modeling. Using the most common exoplanet cooling model, and given the system age of 160(+350/−60) Myr, GJ 504 b has an estimated mass of 4(+4.5/−1.0) Jupiter masses, among the lowest of directly imaged planets. Its projected separation of 43.5 AU exceeds the typical outer boundary of approx.. 30 AU predicted for the core accretion mechanism. GJ 504 b is also significantly cooler (510(+30/−20) K)) and has a bluer color (J − H = −0.23 mag) than previously imaged exoplanets, suggesting a largely cloud-free atmosphere accessible to spectroscopic characterization. Thus, it has the potential of providing novel insights into the origins of giant planets, as well as their atmospheric properties.

exoplanets↗

Exoplanet Biosignatures: At the Dawn of a New Era of Planetary Observations

The rapid rate of discoveries of exoplanets has expanded the scope of the science possible for the remote detection of life beyond Earth. The Exoplanet Biosignatures Workshop-Without-Walls (EBWWW) held in 2016 engaged the international scientific community across diverse scientific disciplines, to assess the state of the science and technology in the search for life on exoplanets, and to identify paths for progress. The workshop activities resulted in five (5) major review papers which provide: 1) an encyclopedic review of known and proposed biosignatures and models used to ascertain them; 2) an in-depth review of O2 as a biosignature, rigorously examining the nuances of false positives and negatives for evidence of life; 3) a Bayesian framework to comprehensively organize current understanding to quantify confidence in biosignature assessments; 4) an extension of that Bayesian framework in anticipation of increasing planetary data and novel concepts of biosignatures, and 5) a review of the upcoming telescope capabilities to characterize exoplanets and their environment. Because of the immense content of these review papers, this summary provides a guide to their complementary scope and highlights salient features. Strong themes that emerged from the workshop were that biosignatures must be interpreted in the context of their environment, and that frameworks must be developed to link diverse forms of scientific understanding of that context to quantify the likelihood that a biosignature has been observed. Models are needed to explore the parameter space where measurements will be widespread but sparse in detail. Given the technological prospects for large ground-based telescopes and direct imaging from space-based observatories, the detection of atmospheric signatures of a few potentially habitable planets may come before 2030.

spectral imaging↗

Prospects for Inflationary B-Mode Detection

Measurements of the linear polarization of the cosmic microwave background provide a direct window into the physics of inflation. The experimental challenges are daunting: not only is the predicted signal faint compared to the photon noise limit, but it is hidden behind competing foregrounds from both local and cosmic sources. I will discuss the experimental response to these challenges and the prospects for eventual detection and characterization of the inflationary signal.

Kogut, Alan J.↗

Optical Detection of Formaldehyde

The potential for buildup .of formaldehyde in closed space environments poses a direct health hazard to personnel. The National Aeronautic Space Agency (NASA) has established a maximum permitted concentration of 0.04 ppm for 7 to 180 days for all space craft. Early detection is critical to ensure that formaldehyde levels do not accumulate. above these limits. New sensor technologies are needed to enable real time,in situ detection in a compact and reusable form factor. Addressing this need,research into the use of reactive fluorescent dyes which reversibly bind to formaldehyde (liquid or gas) has been conducted to support the development of a formaldehyde.sensor. In the presence of formaldehyde the dyes' characteristic fluorescence peaks shift providing the basis for an optical detection. Dye responses to formaldehyde exposure were characterized; demonstrating the optical detection of formaldehyde in under 10 seconds and down to concentrations of 0.5 ppm. To .incorporate the dye .in.an optical sensor device requires. a means of containing and manipulating the dye. Multiple form factors using two dissimilar s~bstrates were considered to determine a suitable configuration. A prototype sensor was demonstrated and considerations for a field able sensor were presented. This research provides a necessary first step toward the development of a compact, reusable; real time optical formaldehyde sensor suitable for use in the U.S. space program,

Patty, Kira D.↗

Direct measurement of the fundamental rotational transitions of the OH radical by laser sideband spectroscopy

The direct (zero-field) spectra of the fundamental rotational transitions of the OH radical in its Omega = 3/2 and 1/2 states at 2509.9 and 1834.7 GHz are obtained using a recently developed far-infrared laser sideband spectrometer. These measurements have verified and refined the predictions of previous laser magnetic resonance work, thereby confirming the far-infrared detection of interstellar OH. The increased accuracy of these direct measurements will be useful to future astronomical and atmospheric studies of these important transitions.

Farhoomand, J.↗

Optically Stimulated Electron Emission Contamination Monitor and Method

An apparatus and method for performing quality inspections on a test surface based on optically stimulated emission of electrons. In one embodiment, the apparatus comprises a device for producing optical radiation having a plurality of different spectrum lines, selecting at least one of the spectrum lines, and directing the selected spectrum line to the test surface, and circuitry for detecting a current of photoelectrons emitted from the test surface, generating a signal indicative of photoelectron current, and for indicating a condition of quality based on the generated signal indicative of the photoelectron current. In one embodiment, the method comprises producing optical radiation having a plurality of different spectrum lines, selecting at least one of the spectrum lines and directing the selected spectrum line to the test surface, detecting a current of photoelectrons emitted from the test surface and generating a signal indicative of photoelectron current, and indicating a condition of quality based on the generated signal indicative of the photoelectron current.

Christopher S Welch↗

Arrayed Micro-Ring Spectrometer System and Method of Use

A spectrometer system includes an array of micro-zone plates (MZP) each having coaxially-aligned ring gratings, a sample plate for supporting and illuminating a sample, and an array of photon detectors for measuring a spectral characteristic of the predetermined wavelength. The sample plate emits an evanescent wave in response to incident light, which excites molecules of the sample to thereby cause an emission of secondary photons. A method of detecting the intensity of a selected wavelength of incident light includes directing the incident light onto an array of MZP, diffracting a selected wavelength of the incident light onto a target focal point using the array of MZP, and detecting the intensity of the selected portion using an array of photon detectors. An electro-optic layer positioned adjacent to the array of MZP may be excited via an applied voltage to select the wavelength of the incident light.

Choi, Sang H.↗

Cutting Edge Technologies Presentation: An Overview of Developing Sensor Technology Directions and Possible Barriers to New Technology Implementation

The aerospace industry requires the development of a range of chemical sensor technologies for such applications as leak detection, emission monitoring, fuel leak detection, environmental monitoring, and fire detection. A range of chemical sensors are being developed based on micromachining and microfabrication technology to fabricate microsensors with minimal size, weight, and power consumption; and the use of nanomaterials and structures to develop sensors with improved stability combined with higher sensitivity, However, individual sensors are limited in the amount of information that they can provide in environments that contain multiple chemical species. Thus, sensor arrays are being developed to address detection needs in such multi-species environments. These technologies and technical approaches have direct relevance to breath monitoring for clinical applications. This presentation gives an overview of developing cutting-edge sensor technology and possible barriers to new technology implementation. This includes lessons learned from previous microsensor development, recent work in development of a breath monitoring system, and future directions in the implementation of cutting edge sensor technology.

Hunter, Gary W.↗

Surface reflections of Pioneer Venus probe signals

As the four Pioneer Venus probes fell within the atmosphere toward the surface of Venus, each of them transmitted a radio signal directly to earth. Because of the relatively broad antenna beamwidth of these small probes, some of the transmitted power went down to the surface of Venus. This paper reports the discovery that the radio signals scattered off the surface are not only detectable but that their characteristics can be determined with a surprising degree of certainty. From these characteristics one can determine parameters of the Venusian atmospheric winds and of the surface that promise to be useful. Most of the scattered energy is that which originally radiated from the probes in a near-horizontal direction; the downward-directed radiation is detectable but much weaker. Refraction in the atmosphere of Venus clearly plays a significant role in establishing both the strength of scatter and its Doppler shift.

Croft, T. A.↗