Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Spin-filter tunneling detection of antiferromagnetic resonance with electrically tunable damping

Antiferromagnetic spintronics offers the potential for higher-frequency operations and improved insensitivity to magnetic fields compared to ferromagnetic spintronics. However, previous electrical techniques to detect antiferromagnetic dynamics have utilized large, millimeter-scale bulk crystals. In this work, we demonstrate direct electrical detection of antiferromagnetic resonance in structures on the few-micrometer scale using spin-filter tunneling in platinum ditelluride (PtTe 2 )/bilayer chromium sulfide bromide (CrSBr)/graphite junctions in which the tunnel barrier is the van der Waals antiferromagnet CrSBr. This sample geometry allows not only efficient detection but also electrical control of the antiferromagnetic resonance through spin-orbit torque from the PtTe 2 electrode. The ability to efficiently detect and control antiferromagnetic resonance enables detailed studies of the physics governing these high-frequency dynamics.

Cham, Thow Min Jerald [Cornell University, Ithaca,↗

Impedance-Based Detection of NO 2 Using Ni-MOF-74: Influence of Competitive Gas Adsorption

Chemically robust, low-power sensors are needed for the direct electrical detection of toxic gases. Metal–organic frameworks (MOFs) offer exceptional chemical and structural tunability to meet this challenge, though further understanding is needed regarding how coadsorbed gases influence or interfere with the electrical response. To probe the influence of competitive gases on trace NO 2 detection in a simulated flue gas stream, a combined structure–property study integrating synchrotron powder diffraction and pair distribution function analyses was undertaken, to elucidate how structural changes associated with gas binding inside Ni-MOF-74 pores correlate with the electrical response from Ni-MOF-74-based sensors. Data were evaluated for 16 gas combinations of N 2 , NO 2 , SO 2 , CO 2 , and H 2 O at 50 °C. Fourier difference maps from a rigid-body Rietveld analysis showed that additional electron density localized around the Ni-MOF-74 lattice correlated with large decreases in Ni-MOF-74 film resistance of up to a factor of 6 × 10 3 , observed only when NO 2 was present. These changes in resistance were significantly amplified by the presence of competing gases, except for CO 2 . Without NO 2 , H 2 O rapidly (<120 s) produced small (1–3×) decreases in resistance, though this effect could be differentiated from the slower adsorption of NO 2 by the evaluation of the MOF’s capacitance. Furthermore, samples exposed to H 2 O displayed a significant shift in lattice parameters toward a larger lattice and more diffuse charge density in the MOF pore. Evaluating the Ni-MOF-74 impedance in real time, NO 2 adsorption was associated with two electrically distinct processes, the faster of which was inhibited by competitive adsorption of CO 2 . Together, this work points to the unique interaction of NO 2 and other specific gases (e.g., H 2 O, SO 2 ) with the MOF’s surface, leading to orders of magnitude decrease in MOF resistance and enhanced NO2 detection. Finally, understanding and leveraging these coadsorbed gases will further improve the gas detection properties of MOF materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical Detection of Spin-Hall-Induced Auto-oscillations in Lithium Aluminate Ferrite Thin Films

Ferrimagnetic insulators with ultralow damping are of great interest for their potential applications in energy-efficient computing devices. Here, we report the direct electrical detection of magnetic auto-oscillations in unpatterned ultralow damping ferrimagnetic insulator epitaxial Li 0.5 Al 0.5 Fe 2 O 4 thin films, driven by a current in a proximal Pt nanowire. Auto-oscillations occur for only one current polarity, consistent with the spin-Hall effect inducing the oscillation state. Micromagnetic modeling shows good agreement with the experimental frequency and field dispersions, showing only one dominant oscillation mode, in contrast to the multiple modes typically observed in transition-metal nanowire-type spin-Hall nanooscillators. This study illustrates a new material system for neuromorphic computing and magnonics, a simple material platform with the direct-current generation of high-frequency (~10 GHz) signals and their electrical detection.

36 MATERIALS SCIENCE↗

The Impact of Lidar Detection Sensitivity on Assessing Aerosol Direct Radiative Effects

Spaceborne lidar observations have great potential to provide accurate global estimates of the aerosol direct radiative effect (DRE) in both clear and cloudy conditions. However, comparisons between observations from the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite (CALIPSO) and multiple years of Atmospheric Radiation Measurement (ARM) program’s ground-based Raman lidars (RL) show that CALIPSO does not detect all radiatively significant aerosol, i.e. aerosol that directly modifies the Earth’s radiation budget. We estimated that using CALIPSO observations results in an underestimate of the magnitude of the global mean aerosol DRE by up to 54%. The ARM RL datasets along with NASA Langley airborne high spectral resolution lidar (HSRL) data from multiple field campaigns are used to compute the detection sensitivity required to accurately resolve the aerosol DRE. This shows that a lidar with a backscatter coefficient detection sensitivity of about 1−2x10(exp -4)km(exp -1)sr(exp -1) at 532nm would resolve all the aerosol needed to derive the DRE to within 1%.

Tyler J. Thorsen↗

In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer

A miniaturized instrument for performing chemical and isotopic analysis of rocks has been developed. The rock sample is ablated by a laser and the neutral species produced are analyzed using the JPL-invented miniature mass spectrometer. The direct sampling of neutral ablated material and the simultaneous measurement of all the elemental and isotopic species are the novelties of this method. In this laser ablation-miniature mass spectrometer (LA-MMS) method, the ablated neutral atoms are led into the electron impact ionization source of the MMS, where they are ionized by a 70-eV electron beam. This results in a secondary ion pulse typically 10-100 microsecond wide, compared to the original 5-10-nanosecond laser pulse duration. Ions of different masses are then spatially dispersed along the focal plane of the magnetic sector of the miniature mass spectrometer and measured in parallel by a modified CCD (charge-coupled device) array detector capable of detecting ions directly. Compared to conventional scanning techniques, simultaneous measurement of the ion pulse along the focal plane effectively offers a 100% duty cycle over a wide mass range. LAMMS offers a more quantitative assessment of elemental composition than techniques that detect laser-ionized species produced directly in the ablation process because the latter can be strongly influenced by matrix effects that vary with the structure and geometry of the surface, the laser beam, and the ionization energies of the elements. The measurement of high-precision isotopic ratios and elemental composition of different rock minerals by LAMMS method has been demonstrated. The LA-MMS can be applied for the absolute age determination of rocks. There is no such instrument available presently in a miniaturized version that can be used for NASA space missions. Work is in progress in the laboratory for geochronology of rocks using LA-MMS that is based on K-Ar radiogenic dating technique.

Sinha, Mahadeva P.↗

Inline gamma-spectrometry of fission product elements after rapid high-pressure ion chromatographic separation

Analysis of irradiated material shortly after irradiation can be non-trivial due to highly radioactive activation and fission isotopes increasing dead time in gamma-ray detection systems, often requiring a “cooling-period” between receipt of a sample and the subsequent analysis. A direct separation–detection method has been developed combining ion chromatography and inductively coupled mass spectrometry for rapid, low-level analysis of fission products; it cannot, however, detect certain short-lived species below the detection limit of the system. In this paper we report the implementation of an inline gamma-ray detector, which was added post-separation, pre-analysis, to test the quality and utility of elementally-isolated gamma-ray spectroscopy.

Inline gamma-ray detection↗

Single-Cell Metabolomics with Rapid Determination of Chemical Formulas from Isotopic Fine Structures

Metabolomic measurements can provide functional readouts of cellular states and phenotypes. Here, we present a protocol for single-cell metabolomics that permits direct untargeted detection of a broad number of metabolites under ambient conditions, without the need for sample processing, and with high confidence in the discovery and identification of the molecular formulas for detected metabolites. This protocol describes combining fiber-based laser ablation electrospray ionization (f-LAESI) with a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer (21T-FTICR-MS) to obtain high confidence molecular formula information about detected metabolites. The f-LAESI source utilizes mid-infrared laser ablation through a sharp optical fiber tip, affording direct ambient analysis of cells without the need for sample processing. Using the 21T-FTICR-MS as a mass analyzer enabled measurement of the isotopic fine structure (IFS) for numerous metabolites simultaneously from single cells, and the IFSs were in turn computationally processed to rapidly determine the corresponding elemental compositions. This metabolomics technique complements other single cell omics measurement methods, helping to resolve complex molecular interactions that take place within cells unattainable from single cell transcriptomic and proteomics methods.

mass spectrometry, FTICR, FTMS, ultrahigh mass res↗

Radar-Sounding Characterization of the Subglacial Groundwater Table Beneath Hiawatha Glacier, Greenland

Radar-sounding surveys associated with the discovery of a large impact crater beneath Hiawatha Glacier, Greenland, revealed bright, flat subglacial reflections hypothesized to originate from a subglacial groundwater table. We test this hypothesis using radiometric and hydrologic analysis of those radar data. The dielectric loss between the reflection from the top of the basal layer and subglacial reflection and their reflectivity difference represent dual constraints upon the complex permittivity of the basal material. Either ice-cemented debris or fractured, well-drained bedrock explain the basal layer's radiometric properties. The subglacial reflector's geometry is parallel to isopotential hydraulic head contours, located 7.5–15.3 m below the interface, and 11 ± 7 dB brighter than the ice–basal layer reflection. We conclude that this subglacial reflection is a groundwater table and that its detection was enabled by the wide bandwidth of the radar system and unusual geologic setting, suggesting a path for future direct radar detection of subglacial groundwater elsewhere.

Johnathan T. Bessette↗

Carbon Nanotube Nanoelectrode Array as an Electronic Chip for Ultrasensitive Label-free DNA Detection

A reliable nanoelectrode array based on vertically aligned multi-walled carbon nanotubes (MWNTs) embedded in SiO2 is used for ultrasensitive DNA detection. Characteristic nanoelectrode behavior is observed using low-density MWNT arrays for measuring both bulk and surface immobilized redox species such as K4Fe(CN)6 and ferrocene derivatives. The open-end of MWNTs are found to present similar properties as graphite edge-plane electrodes with wide potential window, flexible chemical functionalities, and good biocompatibility. BRCA1 related oligonucleotide probes with 18 bp are selectively functionalized at the open ends of the nanotube array and specifically hybridized with oligonucleotide targets incorporated with a polyG tag. The guanine groups are employed as the signal moieties in the electrochemical measurements. R(bpy)(sup 2+, sub 3) mediator is used to further amplify the guanine oxidation signal. The hybridization of sub-attomoles of DNA targets is detected electrochemically by combining the MWNT nanoelectrode array with the R(bpy)(sup 2+, sub 3) amplification mechanism. This technique was employed for direct electrochemical detection of label-free PCR amplicon from a healthy donor through specific hybridization with the BRCA1 probe. The detection limit is estimated to be less than 1000 DNA molecules since abundant guanine bases in the PCR amplicon provides a large signal. This system provides a general platform for rapid molecular diagnostics in applications requiring ultrahigh sensitivity, high-degree of miniaturization, and simple sample preparation, and low-cost operation.

Li, Jun↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near-Zero Power MOF-Based Sensors for NO 2 Detection

Detection and capture of toxic nitrogen oxides (NO x ) is important for emissions control of exhaust gases and general public health. The ability to directly electrically detect trace (0.5–5 ppm) NO 2 by a metal–organic framework (MOF)-74-based sensor at relatively low temperatures (50 °C) is demonstrated via changes in electrical properties of M-MOF-74, M = Co, Mg, Ni. The magnitude of the change is ordered Ni > Co > Mg and explained by each variant's NO 2 adsorption capacity and specific chemical interaction. Ni-MOF-74 provides the highest sensitivity to NO 2 ; a 725× decrease in resistance at 5 ppm NO2 and detection limit <0.5 ppm, levels relevant for industry and public health. Furthermore, the Ni-MOF-74-based sensor is selective to NO 2 over N 2 , SO 2 , and air. Linking this fundamental research with future technologies, the high impedance of MOF-74 enables applications requiring a near-zero power sensor or dosimeter, with the active material drawing <15 pW for a macroscale device 35 mm 2 with 0.8 mg MOF-74. Finally, this represents a 10 4 –10 6 × decrease in power consumption compared to other MOF sensors and demonstrates the potential for MOFs as active components for long-lived, near-zero power chemical sensors in smart industrial systems and the internet of things.

47 OTHER INSTRUMENTATION↗

HabEx Space Telescope Optical System Overview: General Astrophysics Instruments

The HabEx (Habitable Exoplanet) concept study is defining a future space telescope with the primary mission of detecting and characterizing planetary systems around nearby stars. The telescope baseline design includes a high-contrast coronagraph and a starshade to enable the direct optical detection of exoplanets as close as 70 mas to their star. In addition to the study of exoplanets, HabEx carries two dedicated instruments for general astrophysics. The first instrument is a camera enabling imaging on a 3 arc minute field of view in two bands stretching from the UV at 150 nm to the near infrared at 1800 nm. The same instrument can also be operated as a multi-object spectrograph, with resolution of 2000. The second instrument is a high-resolution UV spectrograph operating from 300 nm down to 115 nm with up to 60,0000 resolution. HabEx would provide the highest resolution UV/optical images ever obtained. Diffraction limited at 0.4 µm, it would outperform all current and approved facilities, including the 30 m class ground-based extremely large telescopes (ELTs), which will achieve ~0.01 arcsecond resolution at near-infrared (IR) wavelengths with adaptive optics, but will be seeing-limited at optical wavelengths. HabEx would observe wavelengths inaccessible from the ground, including the UV and in optical/near-IR atmospheric absorption bands. Operating at L2, far above the Earth’s atmosphere and free from the large thermal swings inherent to HST’s low-Earth orbit, HabEx would provide an ultra-stable platform that will enable science ranging from precision astrometry to the most sensitive weak lensing maps ever obtained. Here we discuss the design concepts of the general astrophysics optical instruments for the proposed observatory.

Nissen, Joel↗

Low power sensor for NO x detection

Detection and capture of toxic nitrogen oxides (NO x ) is important for emissions control of exhaust gases and general public health. The low power sensor provides direct electrically detection of trace (0.5-5 ppm) NO 2 at relatively low temperatures (50° C.) via changes in the electrical properties of nitrogen-oxide-capture active materials. For example, the high impedance of MOF-74 enables applications requiring a near-zero power sensor or dosimeter, such as for smart industrial systems and the internet of things, with 0.8 mg MOF-74 active material drawing <15 pW for a macroscale sensor 35 mm 2 area.

Small, Leo J.↗

Adaptive narrow-band interference rejection in a DS spread-spectrum intercept receiver using transform domain signal processing techniques

An intercept receiver which uses a transform-domain-processing filter is described. This receiver detects direct-sequence BPSK spread-spectrum signals in the presence of narrowband interference by employing adaptive narrowband interference rejection techniques. The improvement in the system performance over that of conventional detection techniques is shown by presenting the results of experimental measurements of probability of detection versus false alarm for an enhanced total power detector. Also presented are certain results corresponding to detection of the spectral lines generated at twice the carrier frequency, wherein the goal is often not just signal detection, but also carrier frequency estimation. The receiver uses one of two transform-domain-processing techniques for adaptive narrowband interference rejection. In the first technique, the narrowband interference is detected and excised in the transform domain by using an adaptive notch filter. In the second technique, the interference is suppressed using soft-limiting in the transform domain.

Gevargiz, John↗

Planetary detection techniques - An overview

Interest in the search for planets around other stars is due to its connection with SETI, the desire to understand the formation of stars and planetary systems, and curiosity about the earth's place in the cosmic neighborhood. Proposed techniques include direct imaging, detection of transits, and detection of stellar radial velocity and positional perturbations. Each method has advantages and is effective at detecting different kinds of planets. It is concluded that the fundamental questions in this field should be answered during the next decade.

Scargle, J. D.↗

Detection of the large-scale tidal field with galaxy multiplet alignment in the DESI Y1 spectroscopic survey

We explore correlations between the orientations of small galaxy groups, or ‘multiplets’, and the large-scale gravitational tidal field. Using data from the Dark Energy Spectroscopic Instrument (DESI) Y1 survey, we detect the intrinsic alignment (IA) of multiplets to the galaxy-traced matter field out to separations of $100\,h^{-1}$ Mpc. Unlike traditional IA measurements of individual galaxies, this estimator is not limited by imaging of galaxy shapes and allows for direct IA detection beyond redshift $z=1$. Multiplet alignment is a form of higher order clustering, for which the scale-dependence traces the underlying tidal field and amplitude is a result of small-scale ($\lt 1h^{-1}$ Mpc) dynamics. Within samples of bright galaxies, luminous red galaxies (LRG) and emission-line galaxies, we find similar scale-dependence regardless of intrinsic luminosity or colour. This is promising for measuring tidal alignment in galaxy samples that typically display no IA. DESI’s LRG mock galaxy catalogues created from the A BACUS S UMMIT N -body simulations produce a similar alignment signal, though with a 33 per cent lower amplitude at all scales. An analytic model using a non-linear power spectrum (NLA) only matches the signal down to 20 $h^{-1}$ Mpc. Our detection demonstrates that galaxy clustering in the non-linear regime of structure formation preserves an interpretable memory of the large-scale tidal field. Multiplet alignment complements traditional two-point measurements by retaining directional information imprinted by tidal forces, and contains additional line-of-sight information compared to weak lensing. This is a more effective estimator than the alignment of individual galaxies in dense, blue, or faint galaxy samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Substrate-enhanced photothermal nano-imaging of surface polaritons in monolayer graphene

Surface polaritons comprise a wealth of light–matter interactions with deep sub-wavelength scale confinement of electromagnetic modes. However, their nanoscale localized dissipation and thermalization processes are not readily accessible experimentally. Here, we introduce photothermal force microscopy to image surface plasmon polaritons (SPPs) in monolayer graphene through their non-radiative SiO2 substrate dissipation. We demonstrate the real-space SPP imaging via photo-induced atomic force detection, and from comparison with scattering-type scanning near-field optical microscopy imaging attribute the force response to substrate dissipation-enhanced thermal expansion. This work illustrates that nano-optical tip–sample induced dissipative forces facilitate a direct mechanical detection of surface polariton interactions with monolayer sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamical Packing in the Habitable Zone: The Case of Beta CVn

Uncovering the occurrence rate of terrestrial planets within the habitable zone (HZ) of their host stars has been a particular focus of exoplanetary science in recent years. The statistics of these occurrence rates have largely been derived from transiting planet discoveries, and have uncovered numerous HZ planets in compact systems around M-dwarf host stars. Here we explore the width of the HZ as a function of spectral type, and the dynamical constraints on the number of stable orbits within the HZ for a given star. We show that, although the Hill radius for a given planetary mass increases with larger semimajor axis, the width of the HZ for earlier-type stars allows for more terrestrial planets in the HZ than late-type stars. In general, dynamical constraints allow ∼6 HZ Earth-mass planets for stellar masses ≳0.7M {sub ⊙}, depending on the presence of farther out giant planets. As an example, we consider the case of Beta CVn, a nearby bright solar-type star. We present 20 yr of radial velocities (RV) from the Keck/High Resolution Echelle Spectrometer (HIRES) and Automated Planet Finder (APF) instruments and conduct an injection-recovery analysis of planetary signatures in the data. Our analysis of these RV data rule out planets more massive than Saturn within 10 au of the star. These system properties are used to calculate the potential dynamical packing of terrestrial planets in the HZ and show that such nearby stellar targets could be particularly lucrative for HZ planet detection by direct imaging exoplanet missions.

79 ASTRONOMY AND ASTROPHYSICS↗