Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DRY STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Cryogenic reactant storage for lunar base regenerative fuel cells

There are major advantages to be gained by integrating a cryogenic reactant storage system with a hydrogen-oxygen regenerative fuel cell (RFC) to provide on-site electrical power during the lunar night. Although applicable to any power system using hydrogen-oxygen RFC's for energy storage, cryogenic reactant storage offers a significant benefit whenever the sun/shade cycle and energy storage period approach hundreds of hours. For solar power installations on the moon, cryogenic reactant storage reduces overall specific mass and meteoroid vulnerability of the system. In addition, it offers synergistic benefits to on-site users, such as availability of primary fuel cell reactants for surface rover vehicles and cryogenic propellants for OTV's. The integration involves processing and storing the RFC reactant streams as cryogenic liquids rather than pressurized gases, so that reactant containment (tankage per unit mass of reactants) can be greatly reduced. Hydrogen-oxygen alkaline RFC's, GaAs photovoltaic (PV) arrays, and space cryogenic processing/refrigeration technologies are assumed to be available for the conceptual system design. Advantages are demonstrated by comparing the characteristics of two power system concepts: a conventional lunar surface PV/RFC power system using pressurized gas storage in SOA filament wound pressure vessels and, that same system with gas liquefaction and storage replacing the pressurized storage. Comparisons are made at 20 and 250 kWe. Although cryogenic storage adds a processing plant (drying and liquefaction) to the system plus 30 percent more solar array to provide processing power, the approximate order of magnitude reduction in tankage mass, confirmed by this analysis, results in a reduction in overall total system mass of approximately 50 percent.

Kohout, Lisa L.↗

Cryogenic reactant storage for lunar base regenerative fuel cells

There are major advantages to be gained by integrating a cryogenic reactant storage system with a hydrogen-oxygen regenerative fuel cell (RFC) to provide on-site electrical power during the lunar night. Although applicable to any power system using hydrogen-oxygen RFC's for energy storage, cryogenic reactant storage offers a significant benefit whenever the sun/shade cycle and energy storage period approach hundreds of hours. For solar power installations on the moon, cryogenic reactant storage reduces overall specific mass and meteoroid vulnerability of the system. In addition, it offers synergistic benefits to on-site users, such as availability of primary fuel cell reactants for surface rover vehicles and cryogenic propellants for OTV's. The integration involves processing and storing the RFC reactant streams as cryogenic liquids rather than pressurized gases, so that reactant containment (tankage per unit mass of reactants) can be greatly reduced. Hydrogen-oxygen alkaline RFC's, GaAs photovoltaic (PV) arrays, and space cryogenic processing/refrigeration technologies are assumed to be available for the conceptual system design. Advantages are demonstrated by comparing the characteristics of two power system concepts: a conventional lunar surface PV/RFC power system using pressurized gas storage in SOA filament wound pressure vessels and, that same system with gas liquefaction and storage replacing the pressurized storage. Comparisons are made at 20 and 250 kWe. Although cryogenic storage adds a processing plant (drying and liquefaction) to the system plus 30 percent more solar array to provide processing power, the approximate order of magnitude reduction in tankage mass, confirmed by this analysis, results in a reduction in overall total system mass of approximately 50 percent.

Kohout, Lisa L.↗

Joint Test Report For Validation of Alternatives to Aliphatic Isocyanate Polyurethanes

National Aeronautics and Space Administration (NASA) and Air Force Space Command (AFSPC) have similar missions and therefore similar facilities and structures in similar environments. The standard practice for protecting metallic substrates in atmospheric environments is the application of an applied coating system. The most common topcoats used in coating systems are polyurethanes that contain isocyanates. Isocyanates are classified as potential human carcinogens and are known to cause cancer in animals. The primary objective of this effort was to demonstrate and validate alternatives to aliphatic isocyanate polyurethanes resulting in one or more isocyanate-free coatings qualified for use at AFSPC and NASA installations participating in this project. This joint Test Report (JTR) documents the results of the laboratory and field testing as well as any test modifications made during the execution of the testing. The technical stakeholders agreed upon test procedure modifications documented in this document. This JTR is made available as a reference for future pollution prevention endeavors by other NASA centers, the Department of Defense and commercial users to minimize duplication of effort. All coating system candidates were tested using approved NASA and AFSPC standard coating systems as experimental controls. This study looked at eight alternative coating systems and two control coating systems and was divided into Phase I Screening Tests, Phase II Tests, and Field Testing. The Phase I Screening Tests were preliminary tests performed on all the selected candidate coating systems. Candidate coating systems that did not meet the acceptance criteria of the screening tests were eliminated from further testing. Phase I Screening Tests included: Ease of Application, Surface Appearance, Dry-To-Touch (Sanding), Accelerated Storage Stability, Pot Life (Viscosity), Cure Time (Solvent Rubs), Cleanability, Knife Test, Tensile (pull-off) Adhesion, and X-Cut Adhesion by Wet Tape After a review of the Phase I test results, four of the alternative coating systems showed substandard performance in relation to the Control Systems and were eliminated from the Phase II testing. Due to the interest of stakeholders and time constraints, however, all eight alternatives were subjected to the following Phase II tests, along with field testing at Stennis Space Center (SSC), Mississippi: Hypergol Compatibility, Liquid Oxygen Compatibility, 18-Month Marine Exposure (Gloss Retention, Color Retention, Blistering, Visual Corrosion, Creepage from Scribe, Heat Adhesion), and Field Exposure (6- and 12-month Evaluation for Coating Condition, Color Retention, Gloss Retention). The remaining four alternative coating systems determined to be the best viable alternatives were carried on to Phase II testing that included: Removability, Repairability, Abrasion Resistance, Gravelometer, Fungus Resistance, Accelerated Weathering, Mandrel Bend Flexibility, and Cyclic Corrosion Resistance. Of the systems that continued to Phase II, three (3) alternative coating systems meet the performance requirements as identified by stakeholders. Two (2) other systems, that were not included in Phase II testing, performed well enough on the 18-Month Marine Exposure, the primary requirement for NASA technical standard NASA-STD-5008, Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment, that they were also considered to be successful candidates. In total, five (5) alternative coating systems were approved for inclusion in the NASA-STD- 5008 Qualified Products List (QPL). The standard is intended to provide a common framework for consistent practices across NASA and is often used by other entities. The standard's QPL does not connote endorsement of the products by NASA, but lists those products that have been tested and meet the requirements as specified.

Lewis, Pattie↗

Anthropogenic Influences Alter the Response and Seasonality of Evapotranspiration: A Case Study Over Two High Mountain Asia Basins

Earth's vegetation has been increasing over the past decades, altering water and energy cycles by changing evapotranspiration (ET). Greening, caused by climatic and anthropogenic factors, has high rates in High Mountain Asia (HMA). Here we focus on two HMA basins (the Yangtze and the Ganges-Brahmaputra) to contrast the impacts of climate- and human-induced greening on ET. Though the rate of greening is similar in both basins, anthropogenic influences lead to dissimilar responses in ET. In the Yangtze, climate-induced greening increases ET, with the increase in moisture being high enough to meet the ET demand. In the Ganges-Brahmaputra, irrigation-induced greening does not alter annual ET, only pre-monsoon ET increases. The dry season declines in water storage due to pumping decrease ET, while laboriously meeting the demand. This study provides a representative example of the contrasting influences of climate induced and anthropogenic driven processes on the seasonality of ET.

Fadji Z Maina↗

Impact of Screening on Behavior During Storage and Cost of Ground Small-Diameter Pine Trees: A Case Study

Whole comminuted trees are known to self-heat and undergo quality changes during storage. Trommel screening after grinding is a process that removes fines from the screened material and removes a large proportion of high-ash, high-nutrient material. In this study, the trade-off between an increase in preprocessing cost from trommel screening and an increase in quality of the screened material was examined. Fresh lodgepole pine (Pinus contorta) was comminuted using a drum grinder with a 10-cm screen, and the resulting material was distributed into separate fines and overs piles. A third pile of unscreened material, the unsorted pile, was also examined. The three piles exhibited different characteristics during a 6-week storage period. The overs pile was much slower to heat. The overs pile reached a maximum temperature of 56.88 degrees C, which was lower than the maximum reached by the other two piles (65.98 degrees C and 63.48 degrees C for the unsorted and fines, respectively). The overs also cooled faster and dried to a more uniform moisture content and had a lower ash content than the other two piles. Both piles of sorted material exhibited improved airflow and more drying than the unsorted material. Looking at supply system costs from preprocessing through in-feed into thermochemical conversion, this study found that trommel screening reduced system costs by over $3.50 per dry matter ton and stabilized material during storage.

01 COAL, LIGNITE, AND PEAT↗

Quantifying Dynamic Water Storage in Unsaturated Bedrock with Borehole Nuclear Magnetic Resonance

Quantifying the volume of water that is stored in the subsurface is critical to studies of water availability to ecosystems, slope stability, and water-rock interactions. In a variety of settings, water is stored in fractured and weathered bedrock as rock moisture. However, few techniques are available to measure rock moisture in unsaturated rock, making direct estimates of water storage dynamics difficult to obtain. Here, we use borehole nuclear magnetic resonance (NMR) at two sites in seasonally dry California to quantify dynamic rock moisture storage. Additionally, we show strong agreement between NMR estimates of dynamic storage and estimates derived from neutron logging and mass balance techniques. The depths of dynamic storage are up to 9 m and likely reflect the depth extent of root water uptake. To our knowledge, these data are the first to quantify the volume and depths of dynamic water storage in the bedrock vadose zone via NMR.

58 GEOSCIENCES↗

Advanced Drying Process for Lower Manufacturing Cost of Electrodes

For this Vehicle Technologies Incubator/Energy Storage R&D topic, Lambda Technologies teamed with Navitas Systems and proposed a new advanced drying process that promised a 5X reduction in electrode drying time and significant reduction in the cost of large format lithium batteries used in PEV's. The operating principle of the proposed process was to use penetrating radiant energy source Variable Frequency Microwaves (VFM), that are selectively absorbed by the polar water or solvent molecules instantly in the entire volume of the electrode. The solvent molecules are thus driven out of the electrode thickness making the process more efficient and much faster than convective drying method. To evaluate the Advanced Drying Process (ADP) a hybrid prototype system utilizing VFM and hot air flow was designed and fabricated. While VFM drives the solvent out of the electrode thickness, the hot air flow exhausts the solvent vapors out of the chamber. The drying results from this prototype were very encouraging. For water based anodes there is a 5X drying advantage (time & length of oven) in using ADP over standard drying system and for the NMP based cathodes the reduction in drying time has 3X benefit. For energy savings the power consumption measurements were performed to ADP prototype and compared with the convection standard drying oven. The data collected demonstrated over 40% saving in power consumption with ADP as compared to the convection drying systems. The energy savings are one of the operational cost benefits possible with ADP. To further speed up the drying process, the ADP prototype was explored as a booster module before the convection oven and for the electrode material being evaluated it was possible to increase the drying speed by a factor of 4, which could not be accomplished with the standard dryer without surface defects and cracks. The instantaneous penetration of microwave in the entire slurry thickness showed a major advantage in rapid drying of the electrode materials. For the existing electrode materials, the material analysis and cell characterization data from ADP dried electrodes showed equivalent (or slightly better) performance. However, for high loading and thicker electrode materials (for high energy densities) the ADP advantages are more prominent. There was less binder migration, the resistance was lower hence the current capacities and retention of the battery cells were higher. The success of the project has enabled credible communications with commercial end users as well as battery coating line integrators. Goal is to scale ADP up for high volume manufacturing of Li-ion battery electrodes. The implementation of ADP in high volume manufacturing will reduce a high cost production step to bring the overall price of Li-ion batteries down. This will ultimately have a positive impact on the public by making electric and hybrid vehicles more affordable.

25 ENERGY STORAGE↗

Global assessment of the carbon–water tradeoff of dry cooling for thermal power generation

Water scarcity and climate change are dual challenges that could potentially threaten energy security. Yet, integrated water–carbon management frameworks coupling diverse water- and carbon-mitigation technologies at high spatial heterogeneity are largely underdeveloped. Here we build a global unit-level framework to investigate the CO 2 emission and energy penalty due to the deployment of dry cooling—a critical water mitigation strategy—together with alternative water sourcing and carbon capture and storage under climate scenarios. We find that CO 2 emission and energy penalty for dry cooling units are location and climate specific (for example, 1–15% of power output), often demonstrating notably faster efficiency losses than rising temperature, especially under the high climate change scenario. Despite energy and CO 2 penalties associated with alternative water treatment and carbon capture and storage utilization, increasing wastewater and brine water accessibility provide potential alternatives to dry cooling for water scarcity alleviation, whereas CO 2 storage can help to mitigate dry cooling-associated CO 2 emission tradeoffs when alternative water supply is insufficient. By demonstrating an integrative planning framework, our study highlights the importance of integrated power sector planning under interconnected dual water–carbon challenges.

42 ENGINEERING↗

Unitized Regenerative Fuel Cell System Gas Dryer/Humidifier Analytical Model Development

A lightweight Unitized Regenerative Fuel Cell (URFC) Energy Storage System concept is being developed at the NASA Glenn Research Center (GRC). This Unitized Regenerative Fuel Cell System (URFCS) is unique in that it uses Regenerative Gas Dryers/Humidifiers (RGD/H) that are mounted on the surface of the gas storage tanks that act as the radiators for thermal control of the Unitized Regenerative Fuel Cell System (URFCS). As the gas storage tanks cool down during URFCS charging the RGD/H dry the hydrogen and oxygen gases produced by electrolysis. As the gas storage tanks heat up during URFCS discharging, the RGD/H humidify the hydrogen and oxygen gases used by the fuel cell. An analytical model was developed to simulate the URFCS RGD/H. The model is in the form of a Microsoft (registered trademark of Microsoft Corporation) Excel worksheet that allows the investigation of the RGD/H performance. Finite Element Analysis (FEA) modeling of the RGD/H and the gas storage tank wall was also done to analyze spatial temperature distribution within the RGD/H and the localized tank wall. Test results obtained from the testing of the RGD/H in a thermal vacuum environment were used to corroborate the analyses.

Burke, Kenneth A.↗

Evaluation of a high-moisture stabilization strategy for harvested microalgae blended with herbaceous biomass: Part I—Storage performance

Here, algal biomass is becoming increasingly attractive as a feedstock for biofuel production. However, the swing in algal biomass production between summer and winter months poses a challenge for delivering predictable, constant feedstock supply to a conversion facility. Drying is one approach for stabilizing algal biomass produced in excess during high productivity summer months for utilization during low productivity months, yet drying is energy intensive and thus costly. Wet, anaerobic storage, or ensiling, is a low-cost approach that is commonly used to preserve high moisture herbaceous feedstock. The potential for microalgae stabilization without the need for drying was investigated in this study by simulating ensiling, in which oxygen limitation drives anaerobic fermentation of soluble sugars to organic acids, dropping the pH and thereby stabilizing the material. Algal biomass, Scenedesmus obliquus , was blended with corn stover and stored in acidic, anaerobic conditions at 60% moisture (wet basis) to simulate wet storage by means of ensiling. Results demonstrate that algae and corn stover blends were successfully preserved in anaerobic, acidic conditions for 30 days with < 2% dry matter loss occurring during storage compared to 21% loss in aerobic, non-acidified conditions. Likewise, Scenedesmus obliquus stored alone at 80% moisture (wet basis) in acidified, anaerobic conditions for 30 days, resulted in dry matter losses of 6–14%, compared to 44% loss in neutral pH, anaerobic storage and 37% loss in a neutral pH, aerobically stored condition. Additional experiments were performed at a larger scale in which an algae and corn stover blend was subject to mechanical oxygen exclusion and a Lactobacillus acidophilus inoculum, resulting in 8% loss over 35 days and further indicating that acidic, anaerobic conditions can stabilize microalgae biomass. In summary, the stabilization of harvested algae can be achieved through anaerobic storage, securing a feedstock that is labile yet of high value.

09 BIOMASS FUELS↗

Arboreal Epiphytes in the Soil-Atmosphere Interface: How Often Are the Biggest “Buckets” in the Canopy Empty?

Arboreal epiphytes (plants residing in forest canopies) are present across all major climate zones and play important roles in forest biogeochemistry. The substantial water storage capacity per unit area of the epiphyte “bucket” is a key attribute underlying their capability to influence forest hydrological processes and their related mass and energy flows. It is commonly assumed that the epiphyte bucket remains saturated, or near-saturated, most of the time; thus, epiphytes (particularly vascular epiphytes) can store little precipitation, limiting their impact on the forest canopy water budget. We present evidence that contradicts this common assumption from (i) an examination of past research; (ii) new datasets on vascular epiphyte and epi-soil water relations at a tropical montane cloud forest (Monteverde, Costa Rica); and (iii) a global evaluation of non-vascular epiphyte saturation state using a process-based vegetation model, LiBry. All analyses found that the external and internal water storage capacity of epiphyte communities is highly dynamic and frequently available to intercept precipitation. Globally, non-vascular epiphytes spend <20% of their time near saturation and regionally, including the humid tropics, model results found that non-vascular epiphytes spend ~1/3 of their time in the dry state (0–10% of water storage capacity). Even data from Costa Rican cloud forest sites found the epiphyte community was saturated only 1/3 of the time and that internal leaf water storage was temporally dynamic enough to aid in precipitation interception. Analysis of the epi-soils associated with epiphytes further revealed the extent to which the epiphyte bucket emptied—as even the canopy soils were often <50% saturated (29–53% of all days observed). Results clearly show that the epiphyte bucket is more dynamic than currently assumed, meriting further research on epiphyte roles in precipitation interception, redistribution to the surface and chemical composition of “net” precipitation waters reaching the surface.

Hargis, Hailey↗

Practical Considerations of Moisture in Baled Biomass Feedstocks

Agricultural residues make up a large portion of the immediately available biomass feedstock for renewable energy markets. Current collection and storage methods rely on existing feed and forage practices designed to preserve nutrients and properties of digestibility. Low-cost collection and storage practices that preserve carbohydrates across a range of inbound moisture contents are needed to assure the economic and technical success of the emerging biomass industry. This study examines the movement of moisture in storage and identifies patterns of migration resulting from several on-farm storage systems and their impacts on moisture measurement and dry matter recovery. Baled corn stover and energy sorghum were stored outdoors in uncovered, tarp-covered, or wrapped stacks and sampled periodically to measure moisture and dry matter losses. Interpolation between discrete sampling locations in the stack improved bulk moisture content estimates and showed clear patterns of accumulation and re-deposition. Atmospheric exposure, orientation, and contact with barriers (i.e., soil, tarp, and wrap surfaces) were found to cause the greatest amount of moisture heterogeneity within stacks. Although the bulk moisture content of many stacks remained in the range suitable for aerobic stability, regions of high moisture were sufficient to support microbial activity, thus support dry matter loss. Stack configuration, orientation, and coverage methods are discussed relative to impact on moisture management and dry matter preservation. Additionally, sample collection and data analysis are discussed relative to assessment at the biorefinery as it pertains to stability in storage, queuing, and moisture carried into processing.

09 BIOMASS FUELS↗

Development of the Integrated Biomass Supply Analysis and Logistics Model (IBSAL)

The Integrated Biomass Supply & Logistics (IBSAL) model is a dynamic (time dependent) model of operations that involve collection, harvest, storage, preprocessing, and transportation of feedstock for use at a biorefinery. The model uses mathematical equations to represent individual unit operations. These unit operations can be assembled by the user to represent the working rate of equipment and queues to represent storage at facilities. The model calculates itemized costs, energy input, and carbon emissions. It estimates resource requirements and operational characteristics of the entire supply infrastructure. Weather plays an important role in biomass management and thus in IBSAL, dictating the moisture content of biomass and whether or not it can be harvested on a given day. The model calculates net biomass yield based on a soil conservation allowance (for crop residue) and dry matter losses during harvest and storage. This publication outlines the development of the model and provides examples of corn stover harvest and logistics.

09 BIOMASS FUELS↗

Contrasting strategies of hydraulic control in two codominant temperate tree species

Biophysical controls on plant water status exist at the leaf, stem, and root levels. Therefore, we pose that hydraulic strategy is a combination of traits governing water use at each of these three levels. Here, we studied sap flux, stem water storage, stomatal conductance, photosynthesis, and growth of red oaks (Quercus rubra) and red maples (Acer rubrum). These species differ in stomatal hydraulic strategy and xylem architecture and may root at different depths. Stable isotope analysis of xylem water was used to identify root water uptake depth. Oaks were shown to access a deeper water source than maples. During non-limiting soil moisture conditions, transpiration was greater in maples than in oaks. However, during a soil dry down, transpiration and stem water storage decreased by more than 80% and 28% in maples but only by 31% and 1% in oaks. We suggest that the preferential use of deep water by red oaks allows the species to continue transpiration and growth during soil water limitations. In this case, deeper roots may provide a buffer against drought-induced mortality. Using 14 years of growth data, we show that maple growth correlates with mean annual soil moisture at 30 cm but oak growth does not. The observed responses of oak and maple to drought were not able to be explained by leaf and xylem physiology alone. Finally, we employed the Finite-difference Ecosystem-scale Tree Crown Hydrodynamics model version 2 plant hydrodynamics model to demonstrate the influence of root, stem, and leaf controls on tree-level transpiration. We conclude that all three levels of hydraulic traits are required to define hydraulic strategy.

54 ENVIRONMENTAL SCIENCES↗

Unitized Regenerative Fuel Cell System Dryer-Humidifier Analytical Model Development

A Unitized Regenerative Fuel Cell (URFC) Energy Storage System is being developed at the NASA Glenn Research Center. This URFC system is unique in that it uses regenerative gas dryers/humidifiers that are mounted on the surface of the gas storage tanks that act as the radiators for thermal control of the URFC system. As the gas storage tanks cool down during URFC charging the regenerative gas dryers/humidifiers dry the hydrogen and oxygen gases produced by electrolysis. As the gas storage tanks heat up during URFC discharging, the regenerative gas dryers/humidifiers humidify the hydrogen and oxygen gases used by fuel cell. An analytical model was developed to simulate the URFC system's regenerative gas dryers/humidifiers. The model is in the form of an EXCEL@ worksheet that allows the investigation of the regenerative gas dryers/humidifier performance as a function of time and position within the regenerative gas dryers/humidifiers, as well as other key system variables. Finite Element Analysis (FEA) modeling of the regenerative gas dryers/humidifier and gas storage tank wall was also done to analyze spatial temperature distribution within the regenerative gas dryers/humidifiers and the localized tank wall. Test results obtained from the testing of the regenerative gas dryers/humidifiers in a thermal vacuum environment were used to corroborate the analyses.

Burke, Kenneth A.↗

West Valley Demonstration Project Annual Site Environmental Report (ASER) for Calendar Year 2014

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2014. The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2014. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2014 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Westinghouse Quiver - A simple and safe system for the complete handling and storing of failed BWR and PWR fuel rods and fragments - 17049

Background: Extracted leaking fuel rods from fuel assemblies have been stored in the spent fuel pools at the Nuclear Power Plants for many years. Sending those fuel rods to an intermediate storage has been very difficult due to the uncertainty of the technical requirements. The Westinghouse Quiver is a container that can be used from the first moment when the leaking fuel rod is extracted from the Fuel Assembly. The leaking fuel rod can be placed in the Westinghouse Quiver. When the Quiver is filled, it can be sealed and dried and then treated as a regular fuel assembly during intermediate storage and final repository. Purpose of System: The purpose of the system is to store leaking fuel rods, broken rods and fuel rod fragments leak tight in the fuel pool and after vacuum drying and permanent sealing at an intermediate storage facility. The Quiver is designed to be fully compatible with a regular fuel assembly. That means all handling of the Quiver in a Nuclear Power Plant, during transportation or storage is also identical to that of a regular fuel assembly. Fulfilling these criteria together with functional testing, the Quiver is considered acceptable for long time storage of leaking fuel rods, both in dry or wet condition. The Quiver has been qualified in Switzerland for use in the spent fuel pool, intermediate storage, and for a final repository. The system will be implemented as well in Sweden during 2016-2019. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗