Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Room Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

High temperature sensor/microphone development for active noise control

The industrial and scientific communities have shown genuine interest in electronic systems which can operate at high temperatures, among which are sensors to monitor noise, vibration, and acoustic emissions. Acoustic sensing can be accomplished by a wide variety of commercially available devices, including: simple piezoelectric sensors, accelerometers, strain gauges, proximity sensors, and fiber optics. Of the several sensing mechanisms investigated, piezoelectrics were found to be the most prevalent, because of their simplicity of design and application and, because of their high sensitivity over broad ranges of frequencies and temperature. Numerous piezoelectric materials are used in acoustic sensors today; but maximum use temperatures are imposed by their transition temperatures (T(sub c)) and by their resistivity. Lithium niobate, in single crystal form, has the highest operating temperature of any commercially available material, 650 C; but that is not high enough for future requirements. Only two piezoelectric materials show potential for use at 1000 C; AlN thin film reported to be piezoactive at 1150 C, and perovskite layer structure (PLS) materials, which possess among the highest T(sub c) (greater than 1500 C) reported for ferroelectrics. A ceramic PLS composition was chosen. The solid solution composition, 80% strontium niobate (SN) and 20% strontium tantalate (STa), with a T(sub c) approximately 1160 C, was hot forged, a process which concurrently sinters and renders the plate-like grains into a highly oriented configuration to enhance piezo properties. Poled samples of this composition showed coupling (k33) approximately 6 and piezoelectric strain constant (d33) approximately 3. Piezoactivity was seen at 1125 C, the highest temperature measurement reported for a ferroelectric ceramic. The high temperature piezoelectric responses of this, and similar PLS materials, opens the possibility of their use in electronic devices operating at temperatures up to 1000 C. Concurrent with the materials study was an effort to define issues involved in the development of a microphone capable of operation at temperatures up to 1000 C; important since microphones capable of operation above 260 C are not generally available. The distinguishing feature of a microphone is its diaphragm which receives sound from the atmosphere: whereas, most other acoustic sensors receive sound through the solid structure on which they are installed. In order to gain an understanding of the potential problems involved in designing and testing a high temperature microphone, a prototype was constructed using a commercially available lithium niobate piezoelectric element in a stainless steel structure. The prototype showed excellent frequency response at room temperature, and responded to acoustic stimulation at 670 C, above which temperature the voltage output rapidly diminished because of decreased resistivity in the element. Samples of the PLS material were also evaluated in a simulated microphone configuration, but their voltage output was found to be a few mV compared to the 10 output of the prototype.

Shrout, Thomas R.↗

Transforming any Facility for Meeting Strict Cleanliness Requirements

Over the life of the James Webb Space Telescope (JWST), Integration & Test (I&T) has taken place in areas that needed considerable work to make the facility itself and/or the protocols used while working in the rooms suitable to meet JWST percent area coverage (PAC) and molecular accumulation requirements. In addition to normal particulate matter, JWST had a uniquely significant challenge: fibers! Fibers not only cause much higher PAC levels, but they also risk damaging the angstrom sized Near Infrared Spectrometer (NIRSpec) microshutter array (MSA), which is critical to NIRSpec instrument performance. The primary emphasis of this paper is to address particulate and fiber contamination. The success of the JWST mission required effective cleanrooms, protocols, and mitigations in non-cleanroom areas that were pressed into service to house contamination-sensitive optics and scientific instruments. Some presented profound challenges. These included: NASA’s 60-year-old Johnson Space Center (JSC) Chamber A, which had never been used for anything contamination-sensitive, and the European tropical launch facilities, which were designed to meet International Standard Organization (ISO) Class 8 processing for communication satellites. The final challenge for JWST, as if to stare us in the face and say, “I dare you to try and make me clean enough,” was preparing the 4 areas in the Centre Spatial Guyanais (CSG) Final Assembly Building (BAF) located in French Guiana, a building in which one entire side opens for Ariane 5 rocket ingress and egress. This paper will describe our initial evaluation processes and the actual work undertaken to transform even the most challenging areas into first class cleanrooms that met JWST particulate and fiber requirements.

James Webb Space Telescope↗

Automated Cryocooler Monitor and Control System

A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.

Britcliffe, Michael J.↗

Final Demolition and Disposition of 209-E Critical Mass Laboratory - 12267

The 209-E Critical Mass Laboratory was constructed in 1960 to provide a heavy shielded reactor room where quantities of plutonium or uranium in solution could be brought to near-critical configurations under carefully controlled and monitored conditions. In the late 1980's, the responsible contractor, Pacific Northwest National Laboratory (PNNL), was directed by the Department of Energy (DOE) to prepare the facility for unoccupied status. The facility was demolished under a Removal Action Work Plan pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The funding for this project was provided by the American Recovery and Reinvestment Act (ARRA). The primary rooms of concern with regards to contamination in 209-E facility, which is over 9,000 square feet, are the criticality assembly room (CAR), the mix room, and the change room. The CAR contained two reactor hoods (HO-140 and HO-170), which each had a high efficiency particulate air (HEPA) filter system. The CAR contained 13 tanks ranging from 38 L (10 gal) to 401 L (106 gal). Tanks TK-109 and TK-110 are below grade, and were removed as part of this demolition and disposition remedy. Nonradiological and radiological hazardous substances were removed, decontaminated, or fixed in place, prior to demolition. Except for the removal of below grade tanks TK-109 and TK-110, the facility was demolished to slab-on-grade. PNNL performed stabilization and deactivation activities that included removal of bulk fissile material and chemicals, flushing tanks, stabilizing contamination within gloveboxes and hoods, and packaging and removing waste. The removal of the contaminated plutonium equipment and materials from the 209E facility presented a number of challenges similar in nature to those associated with the inventory reduction and cleanup activities at the Plutonium Finishing Plant. Although there were no bulk fissile materials or chemicals within the facility, there were residual radiological materials (isotopes of plutonium and americium) in the tanks and hoods. The complexity of the remedy was present because of the various configurations of the tanks and hoods, combined with the residual contaminants. Because of the weight and dimensional configuration, size reduction of the slab tanks, as well as removal and disposal of the different material used for moderation and absorption, were two examples of challenges that were resolved to complete the remedy. One of the key methods developed and implemented at the facility was the design and construction of a shroud to allow the cutting of the Pu contaminated tanks. The shroud design, development and implementation at the 209E Project was an example of enhanced work planning and task hazards analysis with worker involvement. This paper will present the lessons learned from the 209E facility inventory reduction activities including the shroud and other methodologies used. The initial Lessons Learned discussion for this project was scheduled for late January 2012. This facility is the first open-air demolition of a highly contaminated plutonium-contaminated facility accomplished by CH2M Hill under the Plateau Remediation Contract. The demolition was completed without spread of contamination to the workers and the surrounding area. As with any project of this complexity, there are significant accomplishments, as well as experience that can be applied to future demolition of plutonium-contaminated facilities on the Hanford Site. These experiences will be documented at a later date. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fission Product Sorptivity in Graphite

Both adsorption and absorption (sorption) of fission product (FP) gases on/into graphite are issues of interest in very high temperature reactors (VHTRs). In the original proposal, we proposed to use packed beds of graphite particles to measure sorption at a variety of temperatures and to use an electrodynamic balance (EDB) to measure sorption onto single graphite particles (a few μm in diameter) at room temperature. The use of packed beds at elevated temperature is not an issue. However, the TPOC requested revision of this initial proposal to included single particle measurements at elevated temperatures up to 1100 °C. To accommodate the desire of NEUP to extend the single particle EDB measurements to elevated temperatures it was necessary to significantly revise the plan and the budget. These revisions were approved. In the EDB method, we levitate a single graphite particle (the size, surface characteristics, morphology, purity, and composition of the particle can be varied) or agglomerate in the balance and measure the sorption of species by observing the changes in mass. This process involves the use of an electron stepping technique to measure the total charge on a particle which, in conjunction with the measured suspension voltages for the particle, allows for determinations of mass and, hence, of mass changes which then correspond to measurements of sorption. Accommodating elevated temperatures with this type of system required a significant system redesign and required additional time that ultimately was not available. These constraints also meant that the grant had to focus on fewer species as a result. Overall, the extension of the original proposed single particle work to elevated temperatures added greatly to the complexity of the proposed project and added greatly to the time that would eventually be required as well. This means that the bulk of the experimental progress was made using the packed bed sorption systems. Only being able to recruit one graduate student meant that data acquisition with the packed bed systems ended up competing for the graduate student’s available time with the electrodynamic balance redesign and assembly portions of the project. This competition for available time was eventually mitigated to some extent by the later recruitment of an undergraduate student to help with data collection using the packed bed system. It was only the recruitment of the second student that allowed the single particle balance design and construction efforts to proceed as far as they did during the project period. It should be added that some significant time was also spent by the graduate student cataloging previous work involving graphite. This eventually resulted in a review paper being submitted and accepted. Our specific revised objectives in this project were as follows: Experimentally obtain isotherms of Iodine for reactor grade IG-110 samples of graphite particles over a range of temperatures and pressures using an EDB and a temperature controlled EDB; Experimentally obtain isotherms of Iodine for reactor grade IG-110 samples of graphite particles over a range of temperatures and pressures using a packed column bed apparatus; Explore the effect that charge has on the adsorption isotherms of iodine by varying the charges on and the voltages used to suspend the microscopic particles in the EDB; and To interpret these results in terms of the existing models (Langmuir, BET, Freundlich, and others) which we will modify as necessary to include charge related effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Temperature Wireless Communication And Electronics For Harsh Environment Applications

In order for future aerospace propulsion systems to meet the increasing requirements for decreased maintenance, improved capability, and increased safety, the inclusion of intelligence into the propulsion system design and operation becomes necessary. These propulsion systems will have to incorporate technology that will monitor propulsion component conditions, analyze the incoming data, and modify operating parameters to optimize propulsion system operations. This implies the development of sensors, actuators, and electronics, with associated packaging, that will be able to operate under the harsh environments present in an engine. However, given the harsh environments inherent in propulsion systems, the development of engine-compatible electronics and sensors is not straightforward. The ability of a sensor system to operate in a given environment often depends as much on the technologies supporting the sensor element as the element itself. If the supporting technology cannot handle the application, then no matter how good the sensor is itself, the sensor system will fail. An example is high temperature environments where supporting technologies are often not capable of operation in engine conditions. Further, for every sensor going into an engine environment, i.e., for every new piece of hardware that improves the in-situ intelligence of the components, communication wires almost always must follow. The communication wires may be within or between parts, or from the engine to the controller. As more hardware is added, more wires, weight, complexity, and potential for unreliability is also introduced. Thus, wireless communication combined with in-situ processing of data would significantly improve the ability to include sensors into high temperature systems and thus lead toward more intelligent engine systems. NASA Glenn Research Center (GRC) is presently leading the development of electronics, communication systems, and sensors capable of prolonged stable operation in harsh 500C environments. This has included world record operation of SiC-based transistor technology (including packaging) that has demonstrated continuous electrical operation at 500C for over 2000 hours. Based on SiC electronics, development of high temperature wireless communication has been on-going. This work has concentrated on maturing the SiC electronic devices for communication purposes as well as the passive components such as resistors and capacitors needed to enable a high temperature wireless system. The objective is to eliminate wires associated with high temperature sensors which add weight to a vehicle and can be a cause of sensor unreliability. This paper discusses the development of SiC based electronics and wireless communications technology for harsh environment applications such as propulsion health management systems and in Venus missions. A brief overview of the future directions in sensor technology is given including maturing of near-room temperature "Lick and Stick" leak sensor technology for possible implementation in the Crew Launch Vehicle program. Then an overview of high temperature electronics and the development of high temperature communication systems is presented. The maturity of related technologies such as sensor and packaging will also be discussed. It is concluded that a significant component of efforts to improve the intelligence of harsh environment operating systems is the development and implementation of high temperature wireless technology

Hunter, G. W.↗

The Importance of Contamination Knowledge - Insights into Mars Sample Return

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (JSC), in Houston, TX (henceforth Curation Office) manages the curation of all past, present, and future extraterrestrial samples returned by NASA missions and shared collections from international partners, preserving their integrity for future scientific study while providing the samples to the international community in a fair and unbiased way. The Curation Office also curates all reference and witness materials for each mission (e.g., flight and non-flight hardware coupons; lubricants; non-flight, flight-like, and flown witness plates). These reference and witness materials provide the scientific community with the fundamental ability to reconstruct the contamination/alteration history of the sample collection through the course of the mission, with the overall goal of strengthening the scientific conclusions drawn from the study of returned materials. The information gained from characterizing the physical, biological, inorganic, and organic chemical properties of reference and witness materials is defined as the Contamination Knowledge (CK) of the sample collection. Unlike the data collected for Contamination Control (CC) and Planetary Protection (PP), CK is exclusively concerned with preserving reference and witness materials for study by future scientists upon sample return. Although CC and PP data collected for sample integrity and forward contamination purposes can be complementary to CK, they are two separate data sets with distinct objectives. A robust collection of samples for CK is necessary to allow the extraterrestrial material in a returned sample to be distinguished from terrestrial contamination. Traditionally CK is utilized by sample scientists in order to accomplish the mission’s scientific objectives, however this information can also be utilized by the Office of Planetary Protection to help evaluate the presence of any back contamination. Mars 2020, the first phase of a potential multipart Mars Sample Return (MSR) campaign, is expected to contribute to NASA’s Mars Exploration Program Science Goals by filling in knowledge gaps concerning: 1) the existence of past or present life on Mars, 2) the past and present climate of Mars, 3) the geology of Mars, and 4) hazards associated with human exploration of Mars. Although there is debate concerning which samples will best answer these questions, the necessity for proper sample blanks is well-understood. The CC and PP requirements, driven by the restricted Class V mission designation, are the most stringent of any sample return mission in recent history. The extremely low levels of allowable terrestrial contamination on the spacecraft and rover can complicate these analyses given the detection limits of current analytical instrumentation, especially in the case of biological contamination. By collecting and curating unanalyzed samples specifically for CK, future sample scientists will not be relegated to: 1) relying on data collected using possibly obsolete tools and techniques for return sample blanks, or 2) using remnants of extracted and/or cultured samples from ATLO (Assembly, Test, and Launch Operations), which could be incompatible with the desired experimental endpoints or state-of-the-art techniques available at the time of sample return.The addition of biological experimental endpoints to a sample return campaign’s objectives broadens the requisite range in preservation environments (e.g. inert ultra-pure nitrogen gaseous environment at 18 degrees Centigrade versus less than or equal to minus 80 degrees Centigrade) and types of CK samples. As a result, the Curation Office will also curate the following CK samples at less than or equal to minus 80 degrees Centigrade for the Mars 2020 mission: 1) unanalyzed swabs and wipes in sterile containers, 2) all recirculation filters from the clean rooms used for sample and caching subsystem assembly and all filters from the laminar flow benches used to assemble sample intimate hardware, and 3) witness plates collecting airborne contamination within the assembly clean rooms. It has been Curation Office policy since the Apollo missions to preserve as many pristine samples as possible for future scientific research. Although CK is required to be collected for all stages of the MSR campaign, the CK for the Mars 2020 mission is the most critical for understanding contamination in the returned samples given the intimacy between the Martian samples and the Mars 2020 flight hardware. This presentation highlights the importance of CK for sample return missions as well as the traditional and novel types of CK samples required for a successful MSR campaign.

Harrington, A. D.↗

Planetary Protection at Marshall Space Flight Center

Introduction: NASA Marshall Space Flight Center (MSFC) is historically known for its role in propulsion. While this is still the mainstay of MSFC’s expertise, many unique capabilities exist at MSFC which pertain to Planetary Protection (PP), including 1) identifying PP threats, and 2) developing novel methods to neutralize those threats. Furthermore, because these capabilities exist among diverse groups at MSFC, this work promotes collaboration both within and outside MSFC to expand and develop PP studies related to a full spectrum of NASA research, design, manufacture, and test interests. This abstract describes the PP research ongoing at MSFC and describes how it contributes to NASA’s overall PP objectives. Microbial Identification in Cleanrooms: One of the greatest threats to successful implementation of PP requirements is recontamination post bioburden reduction. One method to prevent recontamination is to keep the spacecraft in clean environments (i.e. cleanrooms) as much as possible during assembly and integration. However, cleanrooms are not without their own sources of contamination, which is why NASA is interested in monitoring the cleanliness of cleanrooms and characterizing the microbial species present. Such information allows a greater understanding of the resistance of these microbes to cleaning methods, as well as the risk of their contaminating the targeted planetary body of a given mission. MSFC has multiple cleanrooms of various ISO cleanliness levels onsite. We sampled the air and surfaces of three of these rooms, isolated microbes, and then sequenced the 16S rRNA gene or ITS region of the 18S rRNA gene for bacterial and fungal isolates, respectively. This has resulted in a microbial library which currently includes nearly 100 isolates. Microbial Enumeration of Spacecraft Materials: Currently, there are only a couple bioburden reduction methods approved by NASA, and often the harshness of these methods presents additional concerns or risks related to material properties. The goal of this research is to assess the microbial content of solid rocket motor (SRM) materials potentially used for lander missions. This work aims to more accurately define the risk of planetary contamination by providing empirical data associated with commonly used SRM raw materials. In this study, we pulverized nonmetallic SRM materials using a cryogenic grinder, then analyzed the resulting substrate for microbial colony forming units (CFU). We found that many SRM nonmetallic materials do not harbor detectable bioburden, though a range existed depending on the material. The results from this work provide quantitative data to potentially reduce concerns of contamination, while also providing a foundation for follow up studies into additional sterilization methods and molecular identification of contaminating microbes. Space Environmental Effects on Microbial Survival: One potential area of microbial reduction is the space environment. Understanding the survivability of hardy microbes in space-like conditions is a crucial first step in answering how space may reduce bioburden and if it can be relied upon for adherence to PP requirements. This work studied the effects of ultraviolet (UV) and ionizing radiation on survival of Bacillus atrophaeus spores. Microbes were dried on relevant polymeric materials then exposed to space environmental stressors. Coupons were submerged in water, diluted, and plated to determine survival compared with controls. We found that both UV and ionizing radiation were capable of reducing viability by nearly 99%, but there were still survivors, some with changed morphology indicating resistance mechanisms within certain cells. Manufacturing credit: Finally, given the above-mentioned limitations of the NASA-approved bioburden reduction methods, there is interest in understanding if manufacturing processes may provide enough bioburden reduction without additional PP-specific bakeouts. For instance, some material additives may be antimicrobial. Given this, we investigated the effects of several commonly used rubber additives on the growth of B. atrophaeus spores. We found that some of the materials inhibited growth of the spores, possibly supporting the use of these additives on missions with PP constraints. Future work into manufacturing credit for bioburden reduction includes inoculation of green insulation with B. atrophaeus spores, followed by a typical cure. Thermal profiles will be verified for appropriate temperature and durations to meet PP requirements, and cured samples will be analyzed using a cryogenic grinder to determine survivability of spores.

Chelsi D. Cassilly↗

Investigation of Path Dependence in Commercial Li-ion Cells Chosen for PHEV Duty Cycle Protocols (paper)

Path dependence is emerging as a premier issue of how electrochemical cells age in conditions that are diverse and variable in the time domain. For example, lithium-ion cells in a vehicle configuration will experience a variable combination of usage and rest periods over a range of temperature and state of charge (SOC). This is complicated by the fact that some aging can actually become worse (or better) when a lithium-ion cell is idle for extended periods under calendar-life (calL) aging, as opposed to cycle-life (cycL) conditions where the cell is used within a predictable schedule. The purpose of this study is to bridge the gap between highly idealized and controlled laboratory test conditions and actual field conditions regarding PHEV applications, so that field-type aging mechanisms can be mimicked and quantified in a repeatable laboratory setting. The main parameters are the magnitude and frequency of the thermal cycling, looking at isothermal, mild, and severe scenarios. To date, little is known about Li-ion aging effects caused by thermal cycling superimposed onto electrochemical cycling, and related path dependence. This scenario is representative of what Li-ion batteries will experience in vehicle service, where upon the typical start of a HEV/PHEV, the batteries will be cool or cold, will gradually warm up to normal temperature and operate there for a time, then will cool down after the vehicle is turned off. Such thermal cycling will occur thousands of times during the projected life of a HEV/PHEV battery pack. We propose to quantify the effects of thermal cycling on Li-ion batteries using a representative chemistry that is commercially available. The secondary Li-ion cells used in this study are of the 18650 configuration, have a nominal capacity rating of 1.9 Ah, and consist of a {LiMn2O4 + LiMn(1/3)Ni(1/3)Co(1/3)O2} cathode and a graphite anode. Electrochemical cycling is based on PHEV-relevant cycle-life protocols that are a combination of charge depleting (CD) and charge sustaining (CS) modes discussed in the Battery Test Manual for Plug-in Hybrid Electric Vehicles (INL, March 2008, rev0). A realistic duty cycle will involve both CD and CS modes, the proportion of each defined by the severity of the power demands. We assume that the cells will start each cycling day at 90% SOC, and that they will not be allowed to go below 35% SOC, with operation around 70% SOC being a nominal condition. The 35, 70, and 90% SOC conditions are also being used to define critical aspects of the related reference performance test (RPT) for this investigation. There are three primary components to the RPT, all assessed at room temperature: (A) static and residual capacity (SRC) over a matrix of current, (B) kinetics and pulse performance testing (PPT) over current for SOCs of interest, and (C) EIS for SOCs of interest. The RPT is performed on all cells every 30 day test interval, as well as a pulse-per-day to provide a quick diagnostic snapshot. Where feasible, we utilize various elements of Diagnostic Testing (DT) to characterize performance of the cells and to gain mechanistic-level knowledge regarding both performance features and limitations. We will present the rationale behind the experimental design, early data, and discuss the fundamental tools used to elucidate performance degradation mechanisms.

25 ENERGY STORAGE↗

Closeout of CRADA JSA 2012S004: Chapter 5, Integrated Control System, of the document of the ESS Conceptual Design Report, publicly available at https://europeanspallationsource.se/accelerator-documents

The integrated control system (ICS) is responsible for the whole ESS machine and facility: accelerator, target, neutron scattering instruments and conventional facilities. This unified approach keeps the costs of development, maintenance and support relatively low. ESS has selected a standardised, field-proven controls framework, the Experimental Physics and Industrial Control System (EPICS), which was originally developed jointly by Argonne and Los Alamos National Laboratories. Complementing this selection are best practices and experience from similar facilities regarding platform standardisation, control system development and device integration and commissioning. The components of ICS include the control system core, the control boxes, the BLED database management system, and the human machine interface. The control system core is a set of systems and tools that make it possible for the control system to provide required data, information and services to engineers, operators, physicists and the facility itself. The core components are the timing system that makes possible clock synchronisation across the facility, the machine protection system (MPS) and the personnel protection system (PPS) that prevent damage to the machine and personnel, and a set of control system services. Control boxes are servers that control a collection of equipment (for example a radio frequency cavity). The integrated control system will include many control boxes that can be assigned to one supplier, such as an internal team, a collaborating institute or a commercial vendor. This approach facilitates a clear division of responsibilities and makes integration much easier. A control box is composed of a standardised hardware platform, components, development tools and services. On the top level, it interfaces with the core control system components (timing, MPS, PPS) and with the human-machine interface. At the bottom, it interfaces with the equipment and parts of the facility through a set of analog and digital signals, real-time control loops and other communication buses. The ICS central data management system is named BLED (beam line element databases). BLED is a set of databases, tools and services that is used to store, manage and access data. It holds vital control system configuration and physics-related (lattice) information about the accelerator, target and instruments. It facilitates control system configuration by bringing together direct input-output controller (IOC) con guration and real-time data from proton and neutron beam line models. BLED also simplifies development and speeds up the code-test-debug cycle. The set of tools that access BLED will be tailored to the needs of different categories of users, such as ESS staff physicists, engineers, and operators; external partner laboratories; and visiting experimental instrument users. The human-machine interface is vital to providing a high-quality experience to ICS users. It encompasses a wide array of devices and software tools, from control room screens to engineer terminal windows; from beam physics data tools to post-mortem data analysis tools. It serves users with a wide range of skills from widely varied backgrounds. The Controls Group is developing a set of user profiles to accommodate this diverse range of use-cases and users.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The influence of humic acid and colloidal silica on the sorption of U(VI) onto SRS Sediments Collected from the F/H Area - 15499

Between 1955 and 1988, the F/H Area Seepage Basins located in the center of SRS received approximately 6,814,000 m{sup 3} of acidic waste solutions containing radionuclides and dissolved metals. Uranium (VI) is a key contaminant of concern in groundwater associated with the basins. The pump-and-treat water treatment unit designed and built in 1997 to remove metals and radionuclides eventually became less effective, prompting research for new remedial alternatives. The pump-and-treat system was discontinued in 2004, replaced with a funnel-and-gate system in which base solutions are injected at the gates to raise pH. To take advantage of the potential formation of uranium silicate minerals, Florida International University - Applied Research Center (FIU-ARC), in collaboration with Savannah River National Laboratory (SRNL), is conducting an investigation into a base containing sodium silicate to evaluate whether these solutions have sufficient alkalinity to correct the acidic nature of the aquifer sediments. The research was extended to investigate if U(VI) is bound to colloidal silica and if any synergy exists between humic acid (HA) and colloidal Si that would influence the removal of uranium. Humic substances (HS) are a major component of soil organic matter and are known for their abilities to influence the migration behavior and fate of heavy metals. Studies showed that HA function as an important ion exchange and metal-complexing ligand, carrying a large number of functional groups with high complexing capacity that can greatly affect the mobility behavior of actinides in natural systems. The study investigates if there are any synergistic interactions between U(VI) ions, humic acid and colloidal silica under oxidized conditions and studies the influence of HA and Si on the sorption of U(VI) onto sediments collected from the F/H Area. The experiments also evaluated the effects of different environmental variables such as pH, presence of U(VI) and varying concentrations of HA on the sorption behavior of U(VI) in multi-component batch systems in the pH range between 3 and 8. Several background sediment samples were collected at SRS from archived cores obtained during installation of the well FSB 91C and used for preparation of triplicate samples. The experimental matrix was set up as follows: - Batch 1: Si (3.5 mM) + U (VI) (0.5 ppm) (no sediments and no HA); - Batch 2: Si (3.5 mM) + U (VI) (0.5 ppm) + HA (10 ppm) (no sediments); - Batch 3: U (VI) (0.5 ppm) + HA (10 ppm) (no Si and no sediments); - Batch 4: Sediments + Si (3.5 mM) + U (VI) (0.5 ppm) (no HA); - Batch 5: Sediments + Si (3.5 mM) + U (VI) (0.5 ppm) + HA; - Batch 6: Sediments + U (VI) (0.5 ppm) + HA, (no Si); - Batch 7: Sediments + U (VI) (0.5 ppm) (no Si and no HA). All samples were prepared in triplicate 50-mL conical tubes. All control and experimental tubes were vortexed and kept on a shaker for 24 h at 100 rpm and room temperature. Results showed that the sediment-bearing batches typically exceeded the performance of non-sediment batches. Results showed that the sorption of U(VI) onto sediments was influenced by the pH and the presence of HA. At low pH 3, the addition of HA slightly enhances U(VI) sorption compared to the HA-free samples. This result is consistent with other studies; in the acidic pH range, the addition of HA slightly enhances U(VI) sorption relative to the HA-free system. Conversely, in the pH range of 4 to 7, the sorption of U(VI) on Si was reduced in the presence of HA in comparison to the system without HA. In subsequent experiments the concentration of HA will be increased to 50 ppm. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-Geiger-Mode Single-Photon Avalanche Detector with Low Excess Noise

This design constitutes a self-resetting (gain quenching), room-temperature operational semiconductor single-photon-sensitive detector that is sensitive to telecommunications optical wavelengths and is scalable to large areas (millimeter diameter) with high bandwidth and efficiencies. The device can detect single photons at a 1,550-nm wavelength at a gain of 1 x 10(exp 6). Unlike conventional single photon avalanche detectors (SPADs), where gain is an extremely sensitive function to the bias voltage, the multiplication gain of this device is stable at 1 x 10(exp 6) over a wide range of bias from 30.2 to 30.9 V. Here, the multiplication gain is defined as the total number of charge carriers contained in one output pulse that is triggered by the absorption of a single photon. The statistics of magnitude of output signals also shows that the device has a very narrow pulse height distribution, which demonstrates a greatly suppressed gain fluctuation. From the histograms of both pulse height and pulse charge, the equivalent gain variance (excess noise) is between 1.001 and 1.007 at a gain of 1 x 10(exp 6). With these advantages, the device holds promise to function as a PMT-like photon counter at a 1,550- nm wavelength. The epitaxial layer structure of the device allows photons to be absorbed in the InGaAs layer, generating electron/hole (e-h) pairs. Driven by an electrical field in InGaAs, electrons are collected at the anode while holes reach the multiplication region (InAlAs p-i-n structure) and trigger the avalanche process. As a result, a large number of e-h pairs are created, and the holes move toward the cathode. Holes created by the avalanche process gain large kinetic energy through the electric field, and are considered hot. These hot holes are cooled as they travel across a p -InAlAs low field region, and are eventually blocked by energy barriers formed by the InGaAsP/ InAlAs heterojunctions. The composition of the InGaAsP alloy was chosen to have an 80 meV valance band offset with InAlAs, which is high enough to hinder the transport of the already cooled holes. Being stopped by the energy barrier, holes are accumulated at the junctions to shield the electric field, resulting in a decrease of the electric field in the multiplication region. Because the impact ionization rate is extremely sensitive to the magnitude of the electric field, the field-screening effect drastically reduces the impact ionization rate and quenches the output signals. After the avalanche pulse signal is self-quenched, the accumulated holes at the InGaAsP/ InAlAs interface escape the energy barrier through thermal excitation and tunneling and finally leave the device. The device is thus reset and ready for subsequent photon detection. This recovery time is controlled by the height of the energy barrier and the hole-cooling rate.

Zhao, Kai↗

Shielding implications for secondary neutrons and photons produced within the patient during IMPT

Purpose: Intensity modulated proton therapy (IMPT) uses a combination of computer controlled spot scanning and spot-weight optimized planning to irradiate the tumor volume uniformly. In contrast to passive scattering systems, secondary neutrons and photons produced from inelastic proton interactions within the patient represent the major source of emitted radiation during IMPT delivery. Various published studies evaluated the shielding considerations for passive scattering systems but did not directly address secondary neutron production from IMPT and the ambient dose equivalent on surrounding occupational and nonoccupational work areas. Thus, the purpose of this study was to utilize Monte Carlo simulations to evaluate the energy and angular distributions of secondary neutrons and photons following inelastic proton interactions within a tissue-equivalent phantom for incident proton spot energies between 70 and 250 MeV.Methods: Monte Carlo simulation methods were used to calculate the ambient dose equivalent of secondary neutrons and photons produced from inelastic proton interactions in a tissue-equivalent phantom. The angular distribution of emitted neutrons and photons were scored as a function of incident proton energy throughout a spherical annulus at 1, 2, 3, 4, and 5 m from the phantom center. Appropriate dose equivalent conversion factors were applied to estimate the total ambient dose equivalent from secondary neutrons and photons.Results: A reference distance of 1 m from the center of the patient was used to evaluate the mean energy distribution of secondary neutrons and photons and the resulting ambient dose equivalent. For an incident proton spot energy of 250 MeV, the total ambient dose equivalent (3.6 Multiplication-Sign 10{sup -3} mSv per proton Gy) was greatest along the direction of the incident proton spot (0 Degree-Sign -10 Degree-Sign ) with a mean secondary neutron energy of 71.3 MeV. The dose equivalent decreased by a factor of 5 in the backward direction (170 Degree-Sign -180 Degree-Sign ) with a mean energy of 4.4 MeV. An 8 Multiplication-Sign 8 Multiplication-Sign 8 cm{sup 3} volumetric spot distribution (5 mm FWHM spot size, 4 mm spot spacing) optimized to produce a uniform dose distribution results in an ambient dose equivalent of 4.5 Multiplication-Sign 10{sup -2} mSv per proton Gy in the forward direction.Conclusions: This work evaluated the secondary neutron and photon emission due to monoenergetic proton spots between 70 and 250 MeV, incident on a tissue equivalent phantom. Example calculations were performed to estimate concrete shield thickness based upon appropriate workload and shielding design assumptions. Although lower than traditional passive scattered proton therapy systems, the ambient dose equivalent from secondary neutrons produced by the patient during IMPT can be significant relative to occupational and nonoccupational workers in the vicinity of the treatment vault. This work demonstrates that Monte Carlo simulations are useful as an initial planning tool for studying the impact of the treatment room and maze design on surrounding occupational and nonoccupational work areas.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear Decontamination Evolution and Revolution - 20349

Decontamination, one of the oldest practices in the nuclear industry, is about to change. While no single approach to decontamination is appropriate in all situations, decontamination of highly contaminated surfaces is historically viewed as difficult and/or marginally effective and fixatives and strippable coatings are often called on to manage time sensitive contamination control issues. The deferral of proper decontamination can lead to accumulated concentrations of radioactive material increasing the risk of cross-contamination of workers and equipment while also increasing radiation levels, which further discourages decontamination. The results of the subject testing demonstrate that superior decontamination factors are readily achievable and the ALARA benefit of decontamination is viable through advanced decontamination technologies in conjunction with innovative application techniques. The collateral benefits will save countless radiological man-hours and personnel radiological exposure. The appropriate use of radiological decontamination techniques can prevent or limit the adverse effects of highly radioactive contamination in the work area. High levels of radiological contamination are typically associated with some of the most physically demanding work in the nuclear industry. Additionally, working in highly contaminated environments increases the risk of exposure to elevated levels of airborne radioactivity and radiation from the source term of the contamination, particularly in hard to reach areas or complex equipment. Veolia's Alaron Nuclear Services (Alaron), a fully integrated nuclear facility, has provided the nuclear industry waste treatment, consolidation, repackaging, and broad decontamination services for almost 35 years. In looking at solutions for its customers, as well as for their own facility, Alaron has recently collaborated with Environmental Alternatives, Inc. (EAI), which has provided innovative solutions addressing difficult nuclear decontamination and industrial cleaning challenges since 1989. This broad range of experience along with the products to support the work created an ideal partner for Alaron's needs at their facility. The benefits of collaboration were immediately recognizable to the management of both companies although the decontamination challenge was significant. Due to the nature of the services offered, contamination at the Alaron facility is routine. The recent decontamination experience at Alaron utilized an innovative surfactant process that quickly produces remarkably higher decontamination factors for both removable surface contamination and fixed contamination. Considering the time to decontaminate areas historically designated for high radiological hazard work, the results from this decontamination effort not only reduced contamination levels but also significantly lowered exposure rates in the working environment. The relative ease with which the surfactant is applied, combined with extraordinary decontamination test results, indicates the potential to alter current radiological work processes in a way that improves worker comfort, and removes radiological engineering barriers, allowing Alaron to complete complex radiological tasks more efficiently and effectively. In a series of two simple applications of the decontamination agent to contaminated high bay vertical surfaces, as well as a variety of horizontal and vertical surfaces with variable porousness and surface sealants, there was an overall reduction in removable contamination of approximately 73% with a reduction in area dose of approximately 93%. The results indicate additional reduction in fixed contamination with application of the surfactant. These values are much higher than experienced with more traditional decontamination agents. In conjunction with demonstrating EAI's surfactant on room surfaces, additional studies were conducted on complex geometry equipment including waste processing equipment, tools, and heavily contaminated parts normally handled from Alaron's customers. Evaluations were made with straight application of EAI's surfactant as well as adding additional techniques to the treatment which afforded revolutionary improvements in the levels of contamination removed. Successful decontamination with up to 95% reduction in removable contamination with just one application were demonstrated in several of the trials. This paper outlines the planned approach to use this technology, the variety of surfaces and equipment treated, and the results of the decontamination efforts. Furthermore, this paper discusses options for pretreatment of certain heavily contaminated equipment prior to employees handling and/or working with the equipment. The potential for dose saving and the reduced risk of cross-contamination with the added benefit of lower PPE requirements, produces an enormous potential for cost and time savings. Attendees will benefit from Alaron's experiences and more fully understand the capabilities of EAI's decontamination process. With the variety of contamination agents, forms and surfaces on which the technology was demonstrated, the information will be valuable to a broad cross-section of industry users. The significance of this report demonstrates superior decontamination factors are achievable utilizing the next evolution of decontamination technology and that the ALARA benefits of decontamination are available through advanced and modern decontamination efforts. The collateral benefits will save countless radiological man-hours and valuable personnel radiological exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validating Phasing and Geometry of Large Focal Plane Arrays

The Kepler Mission is designed to survey our region of the Milky Way galaxy to discover hundreds of Earth-sized and smaller planets in or near the habitable zone. The Kepler photometer is an array of 42 CCDs (charge-coupled devices) in the focal plane of a 95-cm Schmidt camera onboard the Kepler spacecraft. Each 50x25-mm CCD has 2,200 x 1,024 pixels. The CCDs accumulate photons and are read out every six seconds to prevent saturation. The data is integrated for 30 minutes, and then the pixel data is transferred to onboard storage. The data is subsequently encoded and transmitted to the ground. During End-to-End Information System (EEIS) testing of the Kepler Mission System (KMS), there was a need to verify that the pixels requested by the science team operationally were correctly collected, encoded, compressed, stored, and transmitted by the FS, and subsequently received, decoded, uncompressed, and displayed by the Ground Segment (GS) without the outputs of any CCD modules being flipped, mirrored, or otherwise corrupted during the extensive FS and GS processing. This would normally be done by projecting an image on the focal plane array (FPA), collecting the data in a flight-like way, and making a comparison between the original data and the data reconstructed by the science data system. Projecting a focused image onto the FPA through the telescope would normally involve using a collimator suspended over the telescope opening. There were several problems with this approach: the collimation equipment is elaborate and expensive; as conceived, it could only illuminate a limited section of the FPA (.25 percent) during a given test; the telescope cover would have to be deployed during testing to allow the image to be projected into the telescope; the equipment was bulky and difficult to situate in temperature-controlled environments; and given all the above, test setup, execution, and repeatability were significant concerns. Instead of using this complicated approach of projecting an optical image on the FPA, the Kepler project developed a method using known defect features in the CCDs to verify proper collection and reassembly of the pixels, thereby avoiding the costs and risks of the optical projection approach. The CCDs composing the Kepler FPA, as all CCDs, had minor defects. At ambient temperature, some pixels look far brighter than they should. These ghot h pixels have a higher rate of charge leakage than the others due to manufacturing variations. They are usually stable over time, and appear at temperatures above 5 oC. The hot pixels on the Kepler FPA were mapped before photometer assembly during module testing. Selected hot pixels were used as target gstars h for the purposes of EEIS testing. gDead h pixels are permanently off, producing a permanently black pixel. These can also be used if there is some illumination of the FPA. During EEIS testing, Dark Current Full Frame Images (FFIs) taken at room temperature were used to create the hot pixel maps for all 84 Kepler photometer CCD channels. Data from two separate nights were used to create two hot pixel maps per channel, which were cross-correlated to remove cosmic ray events which appear to be hot pixels. These hot pixel maps obtained during EEIS testing were compared to the maps made during module testing to verify that the end-to-end data flow was correct.

Standley, Shaun P.↗

Quantum-mechanical evaluation of Np-incorporation into studtite

Radionuclide incorporation into the alteration products of corroded UO 2 in used nuclear fuel may control the release and mobility of key radionuclides, such as the very long-lived minor actinide, 237 Np (τ ½ = 2.1 Ma). Studtite, [UO 2 (O 2 )(H 2 O) 2 ](H 2 O) 2 , may form in the presence of peroxide produced by radiolysis of water in contact with the spent fuel. Experiments have indicated that the studtite structure can incorporate Np; however, due to the low concentrations in the solid, the incorporation mechanism could not be determined. In this study, density functional theory is used to calculate an optimized structure, determine the electronic density of states, and calculate the energetics of the incorporation of Np 6+ vs. Np 5+ +H + into the studtite structure. The definition of the source/sink phase (reference phase) for the cations involved in the incorporation process greatly affects the final incorporation energy. The incorporation energy of Np into studtite based on the 4 + oxide reference phases (e.g., source/sink = NpO 2 /UO 2 ) results in lower incorporation energies (-0.07 and 0.63 eV for Np 6+ and Np 5+ incorporation, respectively) than the incorporation energy calculated using higher-oxide reference phases (e.g., Np 2 O 5 /UO 3 ), where the incorporation energies for Np 5+ and Np 5+ into studtite are 0.42 and 1.12 eV, respectively. In addition, Np6+-incorporation into studtite is energetically more favorable than Np 5+ -incorporation as assessed from the lower incorporation energy. Estimates of the solid-solution behavior from a combination of quantum-mechanical calculations and Monte-Carlo simulations indicate that the Np 6+ - and U 6+ -studtite solid solution is completely miscible at room temperature with respect to a hypothetical Np 6+ -studtite structure. The Np-studtite structure was calculated to be stable with respect to the corresponding oxides, but its formation may be kinetically hindered. Knowledge of the electronic structure provides insight into Np-bonding in the studtite structure. The Np 5f orbitals are within the band gap of studtite, which results in the narrow band gap of Np-incorporated studtite (1.09 eV), as compared with the band gap of studtite alone (2.29 eV).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electrodeposition of InSb branched nanowires: Controlled growth with structurally tailored properties

In this article, electrodeposition method is used to demonstrate growth of InSb nanowire (NW) arrays with hierarchical branched structures and complex morphology at room temperature using an all-solution, catalyst-free technique. A gold coated, porous anodic alumina membrane provided the template for the branched NWs. The NWs have a hierarchical branched structure, with three nominal regions: a “trunk” (average diameter of 150 nm), large branches (average diameter of 100 nm), and small branches (average diameter of sub-10 nm to sub-20 nm). The structural properties of the branched NWs were studied using scanning transmission electron microscopy, transmission electron microscopy, scanning electron microscopy, x-ray diffraction, energy dispersive x-ray spectroscopy, and Raman spectroscopy. In the as-grown state, the small branches of InSb NWs were crystalline, but the trunk regions were mostly nanocrystalline with an amorphous boundary. Post-annealing of NWs at 420 °C in argon produced single crystalline structures along 〈311〉 directions for the branches and along 〈111〉 for the trunks. Based on the high crystallinity and tailored structure in this branched NW array, the effective refractive index allows us to achieve excellent antireflection properties signifying its technological usefulness for photon management and energy harvesting.

36 MATERIALS SCIENCE↗