Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Sparge Sampling of Molten Salts for Online Monitoring via Laser-Induced Breakdown Spectroscopy

A method was developed to sample molten salts by sparging to generate and transport aerosols to an isolated instrument for compositional analysis by laser-induced breakdown spectroscopy (LIBS). Real-time monitoring of molten salt composition is critical to developing molten salt nuclear reactors, which offer enhanced safety and efficiency. In this article, the sparge sampling method is described and compared with sampling using a Collison nebulizer. The size distribution and transport of aerosols produced from molten eutectic NaNO 3 –KNO 3 salt were compared for multiple gas flow rates (75–1200 mL min –1 ) and transport distances (0.68–2.61 m). Both methods produced aerosols ranging from 0.5 to 5.0 μm determined using a cascade impactor. Aerosols were effectively transported without pre- or trace-heating of gas lines, but transport efficiency was reduced by the formation of agglomerates. Sparge sampling was found to use less sample and less gas than a Collison nebulizer while producing a more concentrated aerosol stream (up to 5 μg L –1 ). The effects of laser energy and delay time on the signal quality of LIBS measurements of these aerosols were also studied. High energy and short delay times were found to enhance signal and repeatability, whereas signal-to-background and signal-to-noise ratios were highest at low energy and longer delay times. The capabilities of this system for online monitoring of molten salts were demonstrated with calibrations for Sr and Li with relative standard deviations of 2.6% and 1.5% and limits of detection of 380 and 180 μg g –1 , respectively.

Aerosols↗

EFFECTS OF DIFFUSE BACKGROUND EMISSION AND SOURCE CROWDING ON PHOTOMETRIC COMPLETENESS IN SPITZER SPACE TELESCOPE IRAC SURVEYS: THE GLIMPSE CATALOGS AND ARCHIVES

We characterize the completeness of point source lists from Spitzer Space Telescope surveys in the four Infrared Array Camera (IRAC) bandpasses, emphasizing the Galactic Legacy Infrared Mid-Plane Survey Extraordinaire (GLIMPSE) programs (GLIMPSE I, II, 3D, 360; Deep GLIMPSE) and their resulting point source Catalogs and Archives. The analysis separately addresses effects of incompleteness resulting from high diffuse background emission and incompleteness resulting from point source confusion (i.e., crowding). An artificial star addition and extraction analysis demonstrates that completeness is strongly dependent on local background brightness and structure, with high-surface-brightness regions suffering up to five magnitudes of reduced sensitivity to point sources. This effect is most pronounced at the IRAC 5.8 and 8.0 {mu}m bands where UV-excited polycyclic aromatic hydrocarbon emission produces bright, complex structures (photodissociation regions). With regard to diffuse background effects, we provide the completeness as a function of stellar magnitude and diffuse background level in graphical and tabular formats. These data are suitable for estimating completeness in the low-source-density limit in any of the four IRAC bands in GLIMPSE Catalogs and Archives and some other Spitzer IRAC programs that employ similar observational strategies and are processed by the GLIMPSE pipeline. By performing the same analysis on smoothed images we show that the point source incompleteness is primarily a consequence of structure in the diffuse background emission rather than photon noise. With regard to source confusion in the high-source-density regions of the Galactic Plane, we provide figures illustrating the 90% completeness levels as a function of point source density at each band. We caution that completeness of the GLIMPSE 360/Deep GLIMPSE Catalogs is suppressed relative to the corresponding Archives as a consequence of rejecting stars that lie in the point-spread function wings of saturated sources. This effect is minor in regions of low saturated star density, such as toward the Outer Galaxy; this effect is significant along sightlines having a high density of saturated sources, especially for Deep GLIMPSE and other programs observing closer to the Galactic center using 12 s or longer exposure times.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal observing strategies for velocity-suppressed dark matter annihilation

Numerous particle models for the cosmological dark matter feature a pair-annihilation rate that scales with powers of the relative velocity between the annihilating particles. As a result, the annihilation rate in the central regions of a dark matter halo can be significantly lower than at the halo’s periphery for particular ambient gravitational potentials. While this might be offset by an increasing dark matter pair number density in the inner halo, it raises the question; what angular region for dark matter models with velocity-suppressed annihilation rates optimizes the signal to noise ratio? We consider simplified background models for galactic and extragalactic targets and demonstrate that the optimal observing strategy varies greatly case by case. Generally, a bright central source warrants an annular region of interest, while a flatter background warrants as large as possible an angular region, possibly including the central regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Extended Q-Range Small Angle Neutron Scattering Diffractometer at the SNS

The Extended Q-Range Small Angle Neutron Scattering Diffractometer (EQ-SANS) at the Spallation Neutron Source is designed to have wide neutron momentum transfer (Q) coverage, high neutron beam intensity, and good wavelength resolution. In addition, the design and construction of the instrument aim at achieving maximum signal to noise ratio by minimizing the background. The instrument is located on the 60Hz SNS target. It has a primary flight path of 14m. Its secondary flight path varies from ~1m to 10m. One of the key components in the primary flight path is the neutron optics, consisting of a true-curved multi channel beam bender and sections of neutron guides. The optics is optimized to reduce the neutron transport loss to a minimum, thereby maximizing the available flux on sample. It also enables the avoidance of the direct line of sight of the neutron moderator at downstream locations. The instrument has three bandwidth-limiting choppers. These choppers effectively eliminate higher frame neutrons up to ~38 from the beam. A frame overlap mirror further cleans up the beam by reflecting out neutrons whose wavelengths are longer than ~33 . The bandwidth choppers also allow a frame-skipping mode of operation, which enables the EQ-SANS diffractometer to achieve a dynamic Q-range equivalent to that of a similar machine on a 20Hz source. The two-dimensional low-angle detector, based on 3He tube technologies, offers very high counting rates and counting efficiency. Initial operations have shown that the instrument has achieved its best-in-class design requirement.

EQ-SANS↗

Modeling Aerial Gamma-Ray Backgrounds Using Non-negative Matrix Factorization

Airborne gamma-ray surveys are useful for many applications, ranging from geology and mining to public health and nuclear security. In all these contexts, the ability to decompose a measured spectrum into a linear combination of background source terms can provide useful insights into the data and lead to improvements in the techniques that use spectral energy windows. Multiple methods for the linear decomposition of spectra exist but are subject to various drawbacks, such as allowing negative photon fluxes or requiring detailed Monte Carlo modeling. In this work, we propose using non-negative matrix factorization (NMF) as a data-driven approach to spectral decomposition. Using aerial surveys that include flights over water, we demonstrate that the mathematical approach of NMF finds physically relevant structure in the aerial gamma-ray background, namely, that measured spectra can be expressed as the sum of nearby terrestrial emission, distant terrestrial emission, and radon and cosmic emission. Furthermore, these NMF background components are compared with the background components obtained by noise-adjusted singular value decomposition (NASVD), which contain negative photon fluxes and, thus, do not represent the emission spectra in as straightforward a way. Finally, we comment on the potential areas of research that are enabled by NMF decompositions, such as new approaches to spectral anomaly detection and data fusion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-G-204-01: BEST IN PHYSICS (IMAGING): Effect of Image Processing Parameters On Nodule Detectability in Chest Radiography

Purpose: To investigate the effect of varying system image processing parameters on lung nodule detectability in digital radiography. Methods: An anthropomorphic chest phantom was imaged in the posterior-anterior position using a GE Discovery XR656 digital radiography system. To simulate lung nodules, a polystyrene board with 6.35mm diameter PMMA spheres was placed adjacent to the phantom (into the x-ray path). Due to magnification, the projected simulated nodules had a diameter in the radiographs of approximately 7.5 mm. The images were processed using one of GE’s default chest settings (Factory3) and reprocessed by varying the “Edge” and “Tissue Contrast” processing parameters, which were the two user-configurable parameters for a single edge and contrast enhancement algorithm. For each parameter setting, the nodule signals were calculated by subtracting the chest-only image from the image with simulated nodules. Twenty nodule signals were averaged, Gaussian filtered, and radially averaged in order to generate an approximately noiseless signal. For each processing parameter setting, this noise-free signal and 180 background samples from across the lung were used to estimate ideal observer performance in a signal-known-exactly detection task. Performance was estimated using a channelized Hotelling observer with 10 Laguerre-Gauss channel functions. Results: The “Edge” and “Tissue Contrast” parameters each had an effect on the detectability as calculated by the model observer. The CHO-estimated signal detectability ranged from 2.36 to 2.93 and was highest for “Edge” = 4 and “Tissue Contrast” = −0.15. In general, detectability tended to decrease as “Edge” was increased and as “Tissue Contrast” was increased. A human observer study should be performed to validate the relation to human detection performance. Conclusion: Image processing parameters can affect lung nodule detection performance in radiography. While validation with a human observer study is needed, model observer detectability for common tasks could provide a means for optimizing image processing parameters.

60 APPLIED LIFE SCIENCES↗

High-efficiency high-energy Ka source for the critically-required maximum illumination of x-ray optics on Z using Z-petawatt-driven laser-breakout-afterburner accelerated ultrarelativistic electrons LDRD .

Under the auspices of the Science of Extreme Environments LDRD program, a <2 year theoretical- and computational-physics study was performed (LDRD Project 130805) by Guy R Bennett (formally in Center-01600) and Adam B. Sefkow (Center-01600): To investigate novel target designs by which a short-pulse, PW-class beam could create a brighter K{alpha} x-ray source than by simple, direct-laser-irradiation of a flat foil; Direct-Foil-Irradiation (DFI). The computational studies - which are still ongoing at this writing - were performed primarily on the RedStorm supercomputer at Sandia National Laboratories Albuquerque site. The motivation for a higher efficiency K{alpha} emitter was very clear: as the backlighter flux for any x-ray imaging technique on the Z accelerator increases, the signal-to-noise and signal-to-background ratios improve. This ultimately allows the imaging system to reach its full quantitative potential as a diagnostic. Depending on the particular application/experiment this would imply, for example, that the system would have reached its full design spatial resolution and thus the capability to see features that might otherwise be indiscernible with a traditional DFI-like x-ray source. This LDRD began FY09 and ended FY10.

43 PARTICLE ACCELERATORS↗

Presentation to JAEA Visitors, July 24, 2012 [Slides]

There are 7 Reasons for characterizing spent fuel nuclide concentrations: (1) Provide IAEA with the capability to independently verify the mass of plutonium at any site that has spent fuel; (2) Shipper/receiver difference; (3) Determination of the input accountability mass of an electrochemical (pyro-chemical) processing facility; (4) Continuity of knowledge at spent fuel storage site; (5) Optimal reloads through knowledge of true actinide content; (6) Burnup credit for fuel transport and storage; and (7) Provide confidence to the public that the shipment of spent fuel around the world is being undertaken in a rigorous manner, assuring that material is not diverted during shipment. Types of fuel of interest are: Fast Reactor Fuel, Normal burnup low enriched uranium (LEU), Mixed oxide (MOX), Low burnup LEU, and Research reactor. MCNPX calculates the slowing down and the energy spread for a given time. The principles are: (1) Neutrons slow down in LSDS; (2) Slow neutrons capture preferentially on a fission resonance; (3) Fission emits high-energy neutrons; (4) High-energy neutrons detected in threshold detector (that is not sensitive to slow neutrons) (e.g., 238 U, 232 Th); and (5) The detection time is characteristic of the slow neutron energy. Following each PSR pulse, the entire signal is digitized in 2 nanosecond intervals, and subsequently analyzed Analysis involves applying a digital filter to extract fission pulses in a background of initial oscillations and noise throughout. Some of the noise is not random. Depending on the threshold setting and filter parameters, both the normalization and the trend change. Original PNNL LSDS design required a 1-meter radius cylindrical LSDS. Much higher efficiency would allow us to use a (1.2m) LSDS (this is the LANL LSDS size), or a less intense source, or a combination of both. We still estimate 10 16 total neutrons from the source to obtain 2-3% precision in 239 Pu and 235 U assay.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Scientific/Technical Report: Integrating Advanced Software and Statistical Methods for Spectroscopic Dark Energy Surveys

“Dark energy” is a phenomenon of unknown origin that pervades the vacuum of space and is causing the present-day expansion of the universe to accelerate. Understanding the nature of dark energy is one of the most fundamental challenges to modern physics, having the potential to revolutionize our theories of both gravity and elementary particle physics. The effects of dark energy are currently only accessible to astronomical survey experiments that probe large volumes of the cosmos. One of the most powerful forms of experiment for studying dark energy is the cosmological “redshift survey,” which maps the large-scale structure of the universe as traced by the positions of galaxies, quasars, and intergalactic hydrogen clouds. The signature of dark energy and other cosmological parameters is imprinted on this large-scale structure as it evolves over cosmic time. This project focused on maximizing the accurate extraction of information from redshift surveys by improving the algorithms and statistics applied across the chain of inference from raw pixels to high-level cosmological parameter estimation. At the low level, this project developed new techniques for calibrating and analyzing high-background, low signal-to-noise data from astronomical survey spectrographs to provide reliable three-dimensional maps of galaxies and quasars throughout the universe. At the high level, this project developed new statistical frameworks for understanding the completeness of redshift surveys and the underlying demographics of the galaxies that they observe, thereby allowing for a more accurate connection between survey results and theoretical models. This work contributes to maximizing the scientific reach of existing and planned surveys, and opens new potential feasibility for more ambitious surveys in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NuGraph2: A Graph Neural Network for Neutrino Event Reconstruction

Neutrino experiments are set to probe some of the most important open questions in physics, from CP violation and the nature of dark matter. The technology of choice for many of these experiments is the liquid argon time projection chamber (LArTPC). In current LArTPC experiments, reconstruction performance often represents a limiting factor for the sensitivity. New developments are therefore needed to unlock the full potential of LArTPC experiments. NuGraph2 is a state of the art Graph Neural Network for reconstruction of data in LArTPC experiments. NuGraph2 utilizes a heterogeneous graph structure, with separate subgraphs of 2D nodes (hits in each plane) connected across planes via 3D nodes (space points). The model provides a consistent description of the neutrino interaction across all planes. NuGraph2 is a multi-purpose network, with a common message-passing attention engine connected to multiple decoders with different classification or regression tasks. These include the classification of detector hits according to the particle type that produced them (semantic segmentation) and the separation of hits from the neutrino interaction from hits due to noise or cosmic-ray background. Additional decoders are being developed, performing tasks such as the regression of the neutrino interaction vertex position. Performance results will be presented based on publicly available samples from MicroBooNE. These include both physics performance metrics, achieving 95% accuracy for semantic segmentation and 98% classification of neutrino hits, as well as computational metrics for training and for inference on CPU or GPU. The status of the NuGraph integration in the LArSoft software framework will be presented, as well as initial studies about model interpretability and injection of domain knowledge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neural Network Approaches for Mobile Spectroscopic Gamma-Ray Source Detection

Artificial neural networks (ANNs) for performing spectroscopic gamma-ray source identification have been previously introduced, primarily for applications in controlled laboratory settings. To understand the utility of these methods in scenarios and environments more relevant to nuclear safety and security, this work examines the use of ANNs for mobile detection, which involves highly variable gamma-ray background, low signal-to-noise ratio measurements, and low false alarm rates. Simulated data from a 2” × 4” × 16” NaI(Tl) detector are used in this work for demonstrating these concepts, and the minimum detectable activity (MDA) is used as a performance metric in assessing model performance.In addition to examining simultaneous detection and identification, binary spectral anomaly detection using autoencoders is introduced in this work, and benchmarked using detection methods based on Non-negative Matrix Factorization (NMF) and Principal Component Analysis (PCA). On average, the autoencoder provides a 12% and 23% improvement over NMF- and PCA-based detection methods, respectively. Additionally, source identification using ANNs is extended to leverage temporal dynamics by means of recurrent neural networks, and these time-dependent models outperform their time-independent counterparts by 17% for the analysis examined here. The paper concludes with a discussion on tradeoffs between the ANN-based approaches and the benchmark methods examined here.

Bilton, Kyle J. (ORCID:0000000184553689)↗

Synthesized speech rate and pitch effects on intelligibility of warning messages for pilots

In civilian and military operations, a future threat-warning system with a voice display could warn pilots of other traffic, obstacles in the flight path, and/or terrain during low-altitude helicopter flights. The present study was conducted to learn whether speech rate and voice pitch of phoneme-synthesized speech affects pilot accuracy and response time to typical threat-warning messages. Helicopter pilots engaged in an attention-demanding flying task and listened for voice threat warnings presented in a background of simulated helicopter cockpit noise. Performance was measured by flying-task performance, threat-warning intelligibility, and response time. Pilot ratings were elicited for the different voice pitches and speech rates. Significant effects were obtained only for response time and for pilot ratings, both as a function of speech rate. For the few cases when pilots forgot to respond to a voice message, they remembered 90 percent of the messages accurately when queried for their response 8 to 10 sec later.

Simpson, C. A.↗

Performance and modeling of the GSFC pointing acquisition and tracking system for laser communications

In this paper the NASA Goddard Space Flight Center (GSFC) laser communication pointing, acquisition, and tracking laboratory demonstration program is discussed. This program entails the construction of a flexible brass-board simulation tool, and a supporting computer simulation effort. The result of this program will be a viable test bed to support the design and specification of space-based laser communication terminals and, additionally, to address critical performance issues such as tracking robustness in the presence of background (e.g., stellar or earth) noise and/or internally generated thermal noise.

Fox, N. D.↗

Microwave, Millimeter, Submillimeter, and Far Infrared Spectral Databases

The spectrum of most known astrophysical molecules is derived from transitions between a few hundred to a few hundred thousand energy levels populated at room temperature. In the microwave and millimeter wave regions. spectroscopy is almost always performed with traditional microwave techniques. In the submillimeter and far infrared microwave technique becomes progressively more technologically challenging and infrared techniques become more widely employed as the wavelength gets shorter. Infrared techniques are typically one to two orders of magnitude less precise but they do generate all the strong features in the spectrum. With microwave technique, it is generally impossible and rarely necessary to measure every single transition of a molecular species, so careful fitting of quantum mechanical Hamiltonians to the transitions measured are required to produce the complete spectral picture of the molecule required by astronomers. The fitting process produces the most precise data possible and is required in the interpret heterodyne observations. The drawback of traditional microwave technique is that precise knowledge of the band origins of low lying excited states is rarely gained. The fitting of data interpolates well for the range of quantum numbers where there is laboratory data, but extrapolation is almost never precise. The majority of high resolution spectroscopic data is millimeter or longer in wavelength and a very limited number of molecules have ever been studied with microwave techniques at wavelengths shorter than 0.3 millimeters. The situation with infrared technique is similarly dire in the submillimeter and far infrared because the black body sources used are competing with a very significant thermal background making the signal to noise poor. Regardless of the technique used the data must be archived in a way useful for the interpretation of observations.

Pearson, J. C.↗

High-Temperature Sprayable Phosphor Coating Developed for Measuring Surface Temperatures

The use of phosphor thermography for noncontact temperature measurements in harsh environments has been proven over the last decade, but it has suffered from difficult application procedures such as vapor deposition or sputtering techniques. We have developed a high-temperature-sensitive paint that is easily applied with commercially available paint-spraying equipment and have successfully demonstrated it to temperatures up to 1500 C. Selected phosphors have also shown measurable signals to 1700 C, thus allowing a combination of phosphors to be used in high-temperature binders to make surface temperature measurements from ambient to over 1500 C. Phosphor thermography is an optical technique that measures the time response of fluorescence light, which is a function of the phosphor temperature. The phosphors are excited with short wavelength light (ultraviolet or blue), and they emit light at a longer wavelength. This technique has a benefit over other temperature measurements, such as thermocouples and infrared thermography, in difficult environments such as high blackbody backgrounds, vibration, flames, high electromagnetic noise, or where special windows may be needed. In addition, the sprayable phosphor paints easily cover large or complicated structures, providing full-surface information with a single measurement. Oak Ridge National Laboratories developed and tested the high-temperature binders and phosphors under the direction of the NASA Glenn Research Center. Refractory materials doped with rare earth metals were selected for their performance at high temperature. Survivability, adhesion, and material compatibility tests were conducted at high temperatures in a small furnace while the fluorescent response from the phosphors was being measured. A painted sample in a furnace with a clearly visible fluorescing dot excited by a pulsed laser is shown. Measuring the decay time of this fluorescence yields the surface temperature. One new paint was recently tested in a rocket test stand at Glenn. The floor of a square duct nozzle was painted, and full-field lifetime decay measurements were acquired for multiple firings of the rocket. Good agreement with predicted results was obtained, matching temperature gradients along the length of the nozzle and clearly showing shock structures. These good results were very satisfactory given that the measurements were made looking through the combustion plume. Infrared pyrometry was incapable of making the surface measurements because of the interference from the rocket exhaust, which contaminated the infrared signature.

Bencic, Timothy J.↗

MIT Participation in the Data Analysis of the XRS and XIS Instruments on the Astro-E2 Mission

Since the inception of this grant six weeks ago, we have completed the initial activation of the Suzaku X-ray Imaging Spectrometer (XIS) (on 13 August) and we have supported initial calibration observations. The instrument is performing very well in all respects. We have characterized the spectral resolution and effective area of each XIS sensor. We are especially excited about the scientific opportunities provided by the XIS'S back- illuminated sensor, which exhibits spectral resolution in the sub-keV band unmatched by any X-ray CCD currently in orbit. As specified in our proposal, we have established a web site (http://space.mit.edu/XIS) on which we maintain an up-to-date summary of instrument performance characteristics. Gain, spectral resolution and system noise, as well as residual background rates, are currently available on this site. Although the particle background level is low compared with Chandra and XMM, we are currently evaluating methods to reduce it still further. Techniques under study include use of 5x5 mode information and alternative grade selection methods. Although the primary responsibility for development of instrument response functions rests with our Japanese colleagues, we are incorporating our latest measurements of spectral resolution into some temporary response functions which we hope to make available to the Suzaku General Observer Facility and the Science Working Group(SWG). We are also preparing proposals for use of SWG observing time.

Bautz, Mark↗

Final Results from the BIMA CMB Anisotropy Survey and Search for Signature of the SZ Effect

We report the final results of our study of the cosmic microwave background (CMB) with the BIMA array. Over 1000 hours of observation were dedicated to this project exploring CMB anisotropy on scales between 1' and 2' in eighteen 6'.6 FWHM fields. In the analysis of the CMB power spectrum, the visibility data is divided into two bins corresponding to different angular scales. Modeling the observed excess power as a flat band of average multipole l(sub eff)= 5237, we find deltaT(sup 2)(sub 1) = 220(sup +140)(sub -120) mu K(sup 2) at 68% confidence and deltaT(sup 2)(sub 1) greater than 0 muK(sup 2) with 94.7% confidence. In a second band with average multipole of l(sub eff) = 8748, we find deltaT(sup 2)(sub 2) consistent with zero, and an upper limit 880 muK(sup 2) at 95% confidence. An extensive series of tests and supplemental observations with the VLA provide strong evidence against systematic errors or radio point sources being the source of the observed excess power. The dominant source of anisotropy on these scales is expected to arise from the Sunyaev-Zel'dovich (SZ) effect in a population of distant galaxy clusters. If the excess power is due to the SZ effect, we can place constraints on the normalization of the matter power spectrum sigma(sub 8) = 1.03(sup +0.20)(sub -0.29) at 68% confidence. The distribution of pixel fluxes in the BIMA images are found to be consistent with simulated observations of the expected SZ background and rule out instrumental noise or radio sources as the source of the observed excess power with similar confidence to the detection of excess power. Follow-up optical observations to search for galaxy over-densities anti-correlated with flux in the BIMA images, as might be expected from the SZ effect, proved to be inconclusive.

Dawson, K. S.↗

Development of Grazing Incidence Optics for Neutron Imaging and Scattering

Because of their wave nature, thermal and cold neutrons can be reflected from smooth surfaces at grazing incidence angles, be reflected by multilayer coatings or be refracted at boundaries of different materials. The optical properties of materials are characterized by their refractive indices which are slightly less than unity for most elements and their isotopes in the case of cold and thermal neutrons as well as for x-rays. The motivation for the optics use for neutrons as well as for x-rays is to increase the signal rate and, by virtue of the optic's angular resolution, to improve the signal-to-noise level by reducing the background so the efficiency of the existing neutron sources use can be significantly enhanced. Both refractive and reflective optical techniques developed for x-ray applications can be applied to focus neutron beams. Typically neutron sources have lower brilliance compared to conventional x-ray sources so in order to increase the beam throughput the neutron optics has to be capable of capturing large solid angles. Because of this, the replicated optics techniques developed for x-ray astronomy applications would be a perfect match for neutron applications, so the electroformed nickel optics under development at the Marshall Space Flight Center (MSFC) can be applied to focus neutron beams. In this technique, nickel mirror shells are electroformed onto a figured and superpolished nickel-plated aluminum cylindrical mandrel from which they are later released by differential thermal contraction. Cylindrical mirrors with different diameters, but the same focal length, can be nested together to increase the system throughput. The throughput can be increased further with the use of the multilayer coatings deposited on the reflectivr surface of the mirror shells. While the electroformed nickel replication technique needs to be adopted for neutron focusing, the technology to coat the inside of cylindrical mirrors with neutron multilayers has to be developed. The availability of these technologies would bring new capabilities to neutron instrumentation and, hence, lead to new scientific breakthroughs. We have established a program to adopt the electroformed nickel replication optics technique for neutron applications and to develop the neutron multilayer replication technology.

Gubarev, M. V.↗