Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Agreements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Using projection operators with maximum overlap methods to simplify challenging self-consistent field optimization

Maximum overlap methods are effective tools for optimizing challenging ground- and excited-state wave functions using self-consistent field models such as Hartree-Fock and Kohn-Sham density functional theory. Nevertheless, such models have shown significant sensitivity to the user-defined initial guess of the target wave function. Here in this work, a projection operator framework is defined and used to provide a metric for non-aufbau orbital selection in maximum-overlap-methods. The resulting algorithms, termed the Projection-based Maximum Overlap Method (PMOM) and Projection-based Initial Maximum Overlap Method (PIMOM), are shown to perform exceptionally well when using simple user-defined target solutions based on occupied/virtual molecular orbital permutations. This work also presents a new metric that provides a simple and conceptually convenient measure of agreement between the desired target and the current or final SCF results during a calculation employing a maximum-overlap method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydration of divalent lanthanides, Sm 2+ and Eu 2+ : A molecular dynamics study with polarizable AMOEBA force field

The chemistry of divalent lanthanides, Ln 2+ , is a growing sub-field of heavy element chemistry owing to new synthetic approaches. However, some theoretical aspects of these unusual cations are currently underdeveloped, especially as they relate to their dynamic properties in solution. In this study, we address the hydration of two of the classical Ln 2+ cations, Sm 2+ and Eu 2+ , using atomic multipole optimized energetic for biomolecular applications (AMOEBA) force fields. These cations have not been parameterized to date with AMOEBA, and few studies are available because of their instability with respect to oxidation in aqueous media. Coordination numbers (CN's) of 8.2 and 8.1 respectively for Sm 2+ and Eu 2+ , and 8.8 for both Sm 3+ and Eu 3+ have been obtained and are in good agreement with the few available AIMD and X-ray absorption fine structures studies. The decreased CN of Ln 2+ compared with Ln 3+ arises from progressive water exchange events that indicates the gradual stabilization of 8-coordinate structures with respect to 9-coordinate geometries. Moreover, the effects of the chloride counter anions on the coordination of Ln 2+ cations have been studied at different chloride concentrations in this work. Lastly, water exchange times of Ln 2+ cations have been calculated to provide a comprehensive understanding of the behavior of Eu 2+ and Sm 2+ in aqueous chloride media.

AMOEBA force field parameterization↗

On the performance of composite schemes in determining equilibrium molecular structures

Determination of equilibrium molecular structures is an essential ingredient in predicting spectroscopic parameters that help in identifying molecular carriers of microwave transitions. Here, in this study, the performance of two different ab initio composite approaches for obtaining equilibrium structures, “energy scheme” and “geometry scheme,” is explored and compared to semi-experimental equilibrium structures. This study is performed for a set of 11 molecules which includes diatomics, linear triatomics, and a few non-linear molecules. The ab initio calculations were performed using three tiers of composite chemical recipes. The current results show that as the overall rigor of calculation is increased, the semi-experimental and the ab initio numbers agree to within 0.0003 Å for all molecules in the test set. The composite approach based on correcting the potential energy surface (energy scheme) and the one based on correcting the geometry directly (geometry scheme) show excellent agreement with each other. This work represents a step toward development of efficient and highly accurate procedures for computing ab initio equilibrium structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity analysis of a layered piezoelectric system using ZFEM

The complex variable finite element method (ZFEM) is a numerical technique which aims to find the partial derivatives of the independent variables with respect to variation in dependent parameters declared in the physics. This is done by combining the complex Taylor series expansion within the weak formulation of the governing equation in a coupled system of linear equations forming a complex valued block matrix given by the Cauchy–Riemann matrix representation. In this work, two-dimensional linear first-order elements have been implemented in ZFEM to predict the design derivatives of the mechanical displacement field and the voltage potential field for a layered piezoelectric system in a steady-state study with Dirichlet boundary condition applied at the top and bottom edges of the geometry. This approach allows the standard FEM solution to quantify the sensitivity of the mechanical displacement and voltage potential fields with respect to small variations in the material properties through the information obtained from the computation of the derivatives. The domain is formed by a layered body with PZT-4 and PZT-5 stacked together. For result verification, the numerical solution obtained with ZFEM was compared to results from a commercial FEM package and the solution from the imaginary part was compared to the exact solution of a well-known benchmark problem. In conclusion, comparison of the results showed good agreement for both the real and imaginary parts of the solution and the largest sensitivities were found in PZT-5 specifically in C 13 , C 33 , and ε 33 .

42 ENGINEERING↗

Observational study of the South American low-level jet during the SALLJEX

The South American Low-Level Jet (SALLJ) east of the Andes is a narrow maximum northerly wind present just above the boundary layer. It is an important component of the tropical-extratropical exchange of heat and moisture in South America and favors deep moist convection in Southeastern South America (SESA). In the present study, the SALLJ characteristics during the 2002-2003 summer season are investigated using upper-air measurements collected during the SALLJ Experiment (SALLJEX). At most stations, the highest wind speed was observed below 3000 m between 06 and 12 UTC, mainly in association with a maximization of the northerly component of the wind while the zonal component reached its minimum. Here, an increase in the maximum wind speed from 10°S to Santa Cruz de la Sierra’s latitude and from there a weakening southward was found throughout the SALLJEX network. Additionally, SALLJEX observations allowed to locate SALLJ core purely from observations in a region just east of the Andes in agreement with previous studies. A new localized kinematic classification was developed and applied in this study to analyze the relationship between the SALLJ intensity and the thermodynamic properties of the lower layers of the atmosphere. Weak, moderate, and strong SALLJ categories were defined with a local threshold of the northerly wind speed maximum at each station. The strongest SALLJs were frequently observed at nighttime, while weaker SALLJs were likely to occur at any time of the day. A stabilization of the nocturnal boundary layer was observed between weak and moderate cases whereas a destabilization between moderate and strong cases were found near the time of the wind speed maximum (06 UTC) at Santiago del Estero and Resistencia stations. A deepening of the convective boundary layer and an increase of its mean temperature between weak and strong category during the previous afternoon to nocturnal SALLJs, reveal a possible contribution to the mechanisms that generate the maximum wind speed.

54 ENVIRONMENTAL SCIENCES↗

Effect of XC functionals and dispersion corrections on the DFT‐computed structural and vibrational properties of SrCl 2 –NaCl and ZrF 4 –LiF

Density functional theory (DFT) calculations were performed to examine the impact of exchange–correlation (XC) functionals and van der Waals corrections (specifically the D3 method) on the structural and vibrational properties of the SrCl 2 –NaCl and ZrF 4 –LiF salt systems. Multiple XC functionals, including the local density approximation (LDA), the generalized gradient approximation using the Perdew–Burke–Ernzerhof (PBE) model, and its modified form suitable for solids (PBEsol), the dispersion-corrected PBE-D3 and PBEsol-D3, were considered. Of these functionals, LDA was found to exhibit the highest degree of error, while PBEsol and PBE-D3 displayed the least error. Underestimated lattice parameters compared with experimental values were observed to result in higher force constants, leading to an overprediction of vibrational frequencies. Conversely, an overestimation of lattice parameters was associated with lower vibrational frequencies. The methodology presented in this study yielded results that are in good agreement with experiment, irrespective of the method (finite differences vs. density functional perturbation theory) employed for calculating infrared and Raman spectra. It was further demonstrated that for alkali halides with weak Raman scattering, utilizing a supercell constructed from primitive cells better predicts Raman features than does the use of conventional cells.

Raman↗

Tailored Frequency Conversion in Nonlinear Subwavelength Grating Metaslabs

The use of metaslab waveguides consisting of subwavelength gratings (SWGs) is proposed as a highly flexible approach to obtain phase‐matched frequency conversion in nonlinear integrated devices. Control over the phase matching (PM) condition is achieved through modification of the linear modal propagation constants by the SWG. The method is experimentally demonstrated by fabrication of 0.4 mm‐long GaAs metaslabs designed for second harmonic generation of near‐infrared light. A controlled spectral shift of up to 100 nm in the PM condition, relative to a uniform slab is observed. Excellent agreement is found between the experimental results and finite‐difference eigenmode simulations, which predict a tunable frequency conversion bandwidth of ∼300 nm for the design parameters. The different regimes of PM control supported by the structure are discussed. This work highlights the potential of SWGs as building blocks for tailored frequency conversion in nonlinear integrated devices.

Form birefringence↗

Charge Regulation Stabilizes the Formation of Ionic Liquid‐Based Amphiphilic Oligomer Droplet Interface Bilayers

Amphiphilic charged oligomers (oligodimethylsiloxane – methylimidazolium cation, ODMS-MIM (+) ), assemble into bilayers using the droplet interface bilayer (DIB) platform, possess similar size and functionality as phospholipid bilayers, but exhibit increased stability. The oligomer ionic headgroups (MIM (+) ) are covalently bound to monodisperse, short-chain (n = 13) hydrophobic tails (ODMS). These self-assemble as monolayer brushes at the oil–aqueous interface of water droplets that are influenced by both the charged cationic headgroups, and the nature of the covalently attached tails in the organic phase. Charge regulation (CR) stabilizes the formation of ordered, molecularly close-packed brush phases, which results in highly insulating, stable DIB membranes, with contributions from specific ion-pairing effects, Debye screening, and voltage-dependent electrocompressive stresses. In the oil phase, interactions between hexadecane, a good solvent for ODMS, and the hydrophobic tails result in extended waiting times for bilayer formation compared to phospholipid DIBs, for which hexadecane is a poor solvent. Close agreement between experimental values and predictions for two key parameters, the critical membrane thickness, h c , and maximal grafted headgroup density, Γ 0 , validate an electrostatic CR model consisting of adsorption and partial neutralization of counterions at a charged interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and characterization of a W‐band wide‐beam horn for radio holography

Abstract A W‐band wide‐beam horn suitable for prime‐focus feed is described in this paper. It was designed to provide better illuminations for outer panels of larger reflector antennas and to improve performance of radio holography systems. Much effort has been spent on precise characterization of the amplitude and phase patterns of the wide beam horn which has a direct impact on the measurement accuracy of the radio holography. A far‐field measurement setup with the correction of phase errors due to cable flexing has been developed. Good beam pattern agreement has been achieved between simulation and measurement.

Zhang, Xiaoling↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methyl α‐D‐galactopyranosyl‐(1→3)‐β‐D‐galactopyranoside and methyl β‐D‐galactopyranosyl‐(1→3)‐β‐D‐galactopyranoside: Glycosidic linkage conformation determined from MA'AT analysis

Abstract MA'ATanalysis has been applied to two biologically‐importantO‐glycosidic linkages in two disaccharides, α‐D‐Galp‐(1→3)‐β‐D‐GalpOMe (3) and β‐D‐Galp‐(1→3)‐β‐D‐GalpOMe (4). Using density functional theory (DFT) to obtain parameterized equations relating a group of trans‐O‐glycosidic NMR spin‐couplings to eitherphi(ϕ') orpsi(ψ'), and experimental 3 J COCH , 2 J COC , and 3 J COCC spin‐couplings measured in aqueous solution in 13 C‐labeled isotopomers, probability distributions ofϕ'andψ'in each linkage were determined and compared to those determined by aqueous 1‐μs molecular dynamics (MD) simulation. Good agreement was found between theMA'ATand single‐state MD conformational models of these linkages for the most part, with modest (approximately <15°) differences in the mean values ofϕ'andψ', although the envelope of allowed angles (encoded in circular standard deviations or CSDs) is consistently larger forϕ'determined fromMA'ATanalysis than from MD for both linkages. TheMA'ATmodel of the α‐Galp‐(1→3)‐β‐Galplinkage agrees well with those determined previously using conventional NMR methods ( 3 J COCH values and/or 1 H‐ 1 H NOEs), but some discrepancy was observed for the β‐Galp‐(1→3)‐β‐Galplinkage, which may arise from errors in the conventions used to describe the linkage torsion angles. Statistical analyses of X‐ray crystal structures show ranges ofϕ'andψ'for both linkages that include the mean angles determined fromMA'ATanalyses, although both angles adopt a wide range of values in the crystalline state, withϕ'in β‐Galp‐(1→3)‐β‐Galplinkages showing greater‐than‐expected conformational variability.

Chemistry↗

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗

A Spatially Resolved Evaluation of Accelerated Environmental Aging on Emerging Polypropylene-Based Photovoltaic Backsheets Using Raman Spectroscopy

For this work, accelerated aging was used to assess environmental degradation in emerging co-extruded polypropylene (PP)-based backsheets under three different environmental conditions (65°C/20% relative humidity (RH), 75°C/20% RH, and 75°C/50% RH). Although differential scanning calorimetry did not measure crystallinity changes with exposure, spatially resolved Raman spectroscopy identified crystallinity increases in the core layer of aged samples, indicating a heterogeneous postcrystallization process. The Raman results were in agreement with synchrotron-based microfocused wide-angle X-ray scattering measurements. Cross-sectional nanoindentation was used to correlate localized crystallinity shifts with changes in Young's modulus. A similar trend was found where increased modulus was measured in the core layer, supporting the relationship between modulus and crystallinity. Finally, dielectric characterization was used to assess the impact of these material property changes on performance. While changes in the backsheet material properties and dielectric performance were observed with accelerated aging, these shifts generally equilibrated with time, indicating overall stability in response to environmental stressors. Additionally, the identified heterogeneous material property changes indicate that spatially resolved crystallinity measurements may be a valuable early failure indicator to be used in the assessment of PV backsheet long-term durability.

36 MATERIALS SCIENCE↗

Electrochemical Modeling of PID Leakage Current of PV Modules: Steady-State Current, Transient Current, and RC-Equivalent Circuit

Potential-induced degradation (PID) remains a significant reliability concern for photovoltaic (PV) modules, arising when a voltage difference between the module frame and the solar cells drives unintended leakage current through the glass-encapsulant stack. Although PID ultimately manifests as PID-s, PID-p, or PID-c, the underlying behavior of the leakage current-its magnitude and time dependence-requires clearer electrochemical interpretation. Traditional explanations attribute the initial transient current to bulk capacitive elements of the glass, encapsulant, and antireflection coatings, and the steady-state current according to their effective ohmic resistance. More recent studies, however, indicate that electrochemical charge-transfer processes at the encapsulant-metallization interface can play a dominant role in defining the leakage-current path. This paper develops a unified electrochemical framework for modeling PID leakage current. First, an RC-equivalent circuit is formulated by combining conventional RC elements with a Randles-type interface to capture transient leakage current through double-layer capacitance and faradaic processes at ionic-electronic boundaries. Second, the steady-state current-voltage behavior is explained using a linearized Butler-Volmer relationship, showing that the measured ohmic response corresponds to the low-overpotential limit of charge-transfer kinetics. Analytical results demonstrate that, for typical module materials-3.2-mm soda-lime glass and 0.45-mm encapsulant-the dominant modulators to PID leakage current are the glass surface resistance (under dry-surface conditions), the glass bulk capacitance, and the encapsulant resistance (under wet-surface conditions), with soda lime glass surface and EVA/POE encapsulant resistances primarily governing steady-state current. The proposed electrochemical model is validated against measured leakage-current data, showing good agreement in both the magnitude and the time-dependent evolution of PID leakage current.

14 SOLAR ENERGY↗

Bubbling Water–Treating DBD Plasma Device Optimization Using Experimental and Computational Methods

A dry air atmospheric pressure volume dielectric barrier discharge is employed to fix nitrogen in water. Producing nitrate for use as nitrogen fertilizer is the primary motivation. A 0D chemistry model is developed and informed by the electrical, and geometric characteristics of the device and the plasma gas temperature. Modeled ozone and nitrate densities are compared to those measured experimentally in the plasma effluent and treated liquid for a range of gas temperatures. Modeled and measured ozone densities are in good agreement; however, the model lacks the liquid chemistry to properly represent the measured nitrate density. A gas temperature-based shift from ozone to NO x producing regimes is observed in both experiment and model, and the reactions responsible are evaluated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗