Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACCURACY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Accuracy of the domain method for the material derivative approach to shape design sensitivities

Numerical accuracy for the boundary and domain methods of the material derivative approach to shape design sensitivities is investigated through the use of mesh refinement. The results show that the domain method is generally more accurate than the boundary method, using the finite element technique. It is also shown that the domain method is equivalent, under certain assumptions, to the implicit differentiation approach not only theoretically but also numerically.

Yang, R. J.↗

Wind velocity measurement accuracy with highly stable 12 mJ/pulse high repetition rate CO2 laser master oscillator power amplifier

A coherent CO2 lidar operating in a master oscillator power amplifier configuration (MOPA) is described for both ground-based and airborne operation. Representative data taken from measurements against stationary targets in both the ground-based and airborne configurations are shown for the evaluation of the frequency stability of the system. Examples of data are also given which show the results of anomalous system operation. Overall results demonstrate that velocity measurements can be performed consistently to an accuracy of + or - 0.5 m/s and in some cases + or - 0.1 m/s.

Bilbro, James W.↗

Orbit determination accuracy assessment for an asteroid flyby - A Galileo case study

The Galileo spacecraft may be targeted for a close flyby of an asteroid on its way to an encounter with Jupiter. An orbit determination accuracy analysis was carried out for the case of the asteroid 29 Amphitrite based on the use of radio metric and optical data types. Prior to encounter, the uncertainty in the asteroid's position, based on astrometric observations from earth, amounts to several hundred kilometers. This ephemeris uncertainty constitutes the dominant error in the determination of the spacecraft orbit with respect to Amphitrite. It is shown that the spacecraft-asteroid relative position can be improved by imaging asteroid-star pairs with the Galileo charge-coupled device (CCD) camera, enabling an accurate flyby of the asteroid. The main benefit of optical navigation is to enable the instrument pointing updates necessary for closeup viewing of the asteroid. A discussion of the evolution of the target error ellipse parameters as a function of data coverage and various combinations of radiometric and optical data types is also presented.

Kechichian, Jean A.↗

Large aperture high accuracy satellite laser tracking

A satellite laser ranging station has been established in order to range both low and high earth-orbiting satellites with a few-mm accuracy; this entails precision pointing of a 15-ton, azimuth-elevation-mounted coude telescope. Because tracking is performed under open loop computer control with no feedback from laser returns, the initial acquisition data and the algorithms for orbit computation must be accurate enough to maintain the satellite within the narrow laser beam width. The system is currently being used to track the LAGEOS and STARLETTE satellites.

Mcgarry, Jan L. F.↗

Interactive graphics and analysis accuracy

An important objective of graphical finite element postprocessing is the facility to indicate to the engineer the accuracy of analysis results. The inclusion of mesh quality sensors permits a subjective evaluation of the adequacy of a single analysis being interpreted. For graphical approaches, both strain energy density gradients and discontinuities of unsmoothed responses and their gradients have proved to be effective sensors. Graphical tools which can display discontinuity information effectively are described; these are essentially different from the ordinary methods used for the viewing of smoothed results.

Abel, J. F.↗

The effects of wind-wave coupling on scatterometer wind measurement accuracy

The recent study of the effects of large-scale waves on scatterometer wind-measurement accuracy provides evidence of the important role played by the degree of wind-wave coupling. This degree is quantified by means of a generalized wind fetch introduced by definition. As a result, the fetch-induced bias in the SASS wind speeds is found to be as high as 2 m/s per 100 km of the fetch. An explanation of the bias is suggested based on the consideration of an additional component of surface scattering caused by EM wave diffraction at the crests of individual, sufficiently steep wavelets.

Glazman, Roman E.↗

Accuracy of atmospheric angular momentum estimates from operational analyses

An attempt is made to assess the accuracy of global atmospheric angular momentum determinations by comparing time series of this quantity derived from both the NMC and ECMWF zonal wind analyses for 1981-85. Over this period, the rms difference betwen the two atmospheric series is comparable to the difference between an atmospheric momentum series and the series that is consistent with observed (nontidal) changes in earth rotation. Most of the difference between the NMC and ECMWF global momentum values comes from the region between 33 deg S and 16 deg N. Differences between NMC and ECMWF regional momentum values become vanishingly small in the high latitudes of the Northern Hemisphere, but they remain large throughout the entire Southern Hemisphere. An annual signal of up to 0.5 m/s exists in the difference between the NMC and ECMWF tropospheric zonal wind fields. Although seemingly small, this signal is vertically coherent and leads to a marked annual component in the NMC-ECMWF difference momentum values in the tropics and also for the Northern Hemisphere as a whole.

Rosen, Richard D.↗

Development of response models for the Earth Radiation Budget Experiment (ERBE) sensors. Part 3: ERBE scanner measurement accuracy analysis due to reduced housekeeping data

The accuracy of scanner measurements was evaluated when the sampling frequency of sensor housekeeping (HK) data was reduced from once every scan to once every eight scans. The resulting increase in uncertainty was greatest for sources with rapid or extreme temperature changes. This analysis focused on the mirror attenuator mosaic (MAM) baffle and plate and scanner radiometer baffle due to their relatively high temperature changes during solar calibrations. Since only solar simulator data were available, the solar temperatures were approximated on these components and the radiative and thermal gradients in the MAM baffle due to reflected sunlight. Of the two cases considered for the MAM plate and baffle temperatures, one uses temperatures obtained from the ground calibration. The other attempt uses temperatures computed from the MAM baffle model. This analysis shows that the heat input variations due largely to the solar radiance and irradiance during a scan cycle are small. It also demonstrates that reasonable intervals longer than the current HK data acquisition interval should not significantly affect the estimation of a radiation field in the sensor field-of-view.

Choi, Sang H.↗

The empirical accuracy of uncertain inference models

Uncertainty is a pervasive feature of the domains in which expert systems are designed to function. Research design to test uncertain inference methods for accuracy and robustness, in accordance with standard engineering practice is reviewed. Several studies were conducted to assess how well various methods perform on problems constructed so that correct answers are known, and to find out what underlying features of a problem cause strong or weak performance. For each method studied, situations were identified in which performance deteriorates dramatically. Over a broad range of problems, some well known methods do only about as well as a simple linear regression model, and often much worse than a simple independence probability model. The results indicate that some commercially available expert system shells should be used with caution, because the uncertain inference models that they implement can yield rather inaccurate results.

Vaughan, David S.↗

Effect of element size on the solution accuracies of finite-element heat transfer and thermal stress analyses of space shuttle orbiter

The effect of element size on the solution accuracies of finite-element heat transfer and thermal stress analyses of space shuttle orbiter was investigated. Several structural performance and resizing (SPAR) thermal models and NASA structural analysis (NASTRAN) structural models were set up for the orbiter wing midspan bay 3. The thermal model was found to be the one that determines the limit of finite-element fineness because of the limitation of computational core space required for the radiation view factor calculations. The thermal stresses were found to be extremely sensitive to a slight variation of structural temperature distributions. The minimum degree of element fineness required for the thermal model to yield reasonably accurate solutions was established. The radiation view factor computation time was found to be insignificant compared with the total computer time required for the SPAR transient heat transfer analysis.

Ko, William L.↗

Accuracy requirements and benchmark experiments for CFD validation

The role of experiment in the development of Computation Fluid Dynamics (CFD) for aerodynamic flow prediction is discussed. The CFD verification is a concept that depends on closely coordinated planning between computational and experimental disciplines. Because code applications are becoming more complex and their potential for design more feasible, it no longer suffices to use experimental data from surface or integral measurements alone to provide the required verification. Flow physics and modeling, flow field, and boundary condition measurements are emerging as critical data. Four types of experiments are introduced and examples given that meet the challenge of validation: flow physics experiments; flow modeling experiments; calibration experiments; and verification experiments. Measurement and accuracy requirements for each of these differ and are discussed. A comprehensive program of validation is described, some examples given, and it is concluded that the future prospects are encouraging.

Marvin, Joseph G.↗

Accuracy versus convergence rates for a three dimensional multistage Euler code

Using a central difference scheme, it is necessary to add an artificial viscosity in order to reach a steady state. This viscosity usually consists of a linear fourth difference to eliminate odd-even oscillations and a nonlinear second difference to suppress oscillations in the neighborhood of steep gradients. There are free constants in these differences. As one increases the artificial viscosity, the high modes are dissipated more and the scheme converges more rapidly. However, this higher level of viscosity smooths the shocks and eliminates other features of the flow. Thus, there is a conflict between the requirements of accuracy and efficiency. Examples are presented for a variety of three-dimensional inviscid solutions over isolated wings.

Turkel, Eli↗

Accuracy of analytic energy level formulas applied to hadronic spectroscopy of heavy mesons

Linear and harmonic potential models are used in the nonrelativistic Schroedinger equation to obtain article mass spectra for mesons as bound states of quarks. The main emphasis is on the linear potential where exact solutions of the S-state eigenvalues and eigenfunctions and the asymptotic solution for the higher order partial wave are obtained. A study of the accuracy of two analytical energy level formulas as applied to heavy mesons is also included. Cornwall's formula is found to be particularly accurate and useful as a predictor of heavy quarkonium states. Exact solution for all partial waves of eigenvalues and eigenfunctions for a harmonic potential is also obtained and compared with the calculated discrete spectra of the linear potential. Detailed derivations of the eigenvalues and eigenfunctions of the linear and harmonic potentials are presented in appendixes.

Badavi, Forooz F.↗

Error indicators and accuracy improvements of finite element solutions

Practical and reliable estimators of the discretization errors in engineering problems are developed. Error indicators for identifying the regions or elements of the solution domain which are likely to have the largest discretization errors are presented, and a simple computational procedure for improving the accuracy of the finite element solutions for shell problems is given. The similarities between the proposed procedure and a preconditioned conjugate gradient (PCG) technique are identified and exploited to generate pointwise error indicators from the PCG technique. Numerical examples in the linear static analysis of shells are presented.

Noor, Ahmed K.↗

Hot-wire accuracy in supersonic turbulence from comparisons with laser-induced fluorescence

A hot-wire anemometer and a new, nonintrusive, laser-induced fluorescence (LIF) technique are used to survey a turbulent boundary layer in a supersonic channel flow at Mach no. 2.06. The purpose is to test the accuracy of using the hot wire to measure the fluctuation amplitudes of static temperature and density in a compressible turbulent flow by comparing the results with independent and direct LIF measurements. Several methods of hot-wire calibration and analysis are applied. With each method, the hot-wire response can be related primarily to fluctuations of mass flux and total temperature, from which fluctuations of static temperature and density are calculated. However, these calculations are shown to be valid only if the fluctuations in static pressure are negligible. The acquisition and the analysis of the hot-wire data are often simplified further by neglecting the effects of fluctuations in total temperature. Comparisons of the fluctuation amplitudes of temperature and density obtained by hot-wire and LIF measurements demonstrate that such assumptions might not always be warranted, even in apparently simple flows.

Logan, Pamela↗

Daytime ClO over McMurdo in September 1987: Altitude profile retrieval accuracy

During the 1987 National Ozone Expedition, mm-wave emission line spectra of the 278.6 GHz rotational stratospheric ClO were observed at McMurdo Station, Antarctica. The results confirm the 1986 discovery of a lower stratospheric layer with approximately 100 times the normal amount of ClO; the 1987 observations, made with a spectrometer bandwidth twice that used in 1986, make possible a more accurate retrieval of the altitude profile of the low altitude component of stratospheric ClO from the pressure broadened line shape, down to approximately 16 km. The accuracy of the altitude profile retrievals is discussed, using the daytime (09:30 to 19:30, local time) data from 20 to 24 September, 1987 as an example. The signal strength averaged over this daytime period is approx. 85 percent of the midday peak value. The rate of ozone depletion implied by the observed ClO densities is also discussed.

Barrett, J.↗

Accuracy requirements and benchmark experiments for CFD validation

The role of experiment in the development of Computational Fluid Dynamics (CFD) for aerodynamic flow prediction is discussed. The CFD verification is a concept that depends on closely coordinated planning between computational and experimental disciplines. Because code applications are becoming more complex and their potential for design more feasible, it no longer suffices to use experimental data from surface or integral measurements alone to provide the required verification. Flow physics and modeling, flow field, and boundary condition measurements are emerging as critical data. Four types of experiments are introduced and examples are given that meet the challenge of validation: flow physics experiments; flow modeling experiments; calibration experiments; and verification experiments. Measurement and accuracy requirements for each of these differ and are discussed. A comprehensive program of validation is described, some examples given, and it is concluded that the future prospects are encouraging.

Marvin, Joseph G.↗