Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Methods of reducing vehicle aerodynamic drag

A small scale model (length 1710 mm) of General Motor SUV was built and tested in the wind tunnel for expected wind conditions and road clearance. Two passive devices, rear screen which is plate behind the car and rear fairing where the end of the car is aerodynamically extended, were incorporated in the model and tested in the wind tunnel for different wind conditions. The conclusion is that rear screen could reduce drag up to 6.5% and rear fairing can reduce the drag by 26%. There were additional tests for front edging and rear vortex generators. The results for drag reduction were mixed. It should be noted that there are aesthetic and practical considerations that may allow only partial implementation of these or any drag reduction options.

42 ENGINEERING↗

Progress Towards a Predictive Eagle Behavior and Risk Modeling Framework: Overview and Recent Validation Efforts

This presentation summarizes progress to date of the U.S. Department of Energy project, "Development of a computational framework for modeling golden eagles (Aquila chrysaetos) near wind farms," which focuses on stochastic behavioral modeling of soaring raptors across landscape, facility, and turbine spatiotemporal scales. This publicly available, open-source modeling framework includes behavioral models based on three different underlying principles: energy minimization at landscape scale, behavioral heuristics at landscape-facility scale, and data-driven behaviors at the facility-micro-scale. We will briefly overview the key advancements in the behavioral modeling state of the art, which leverages multiple high-resolution telemetry data sources combined with high-fidelity atmospheric flow modeling insights. We then present preliminary results from a validation study in Altamont, California. This new study involves a novel application of the Stochastic Soaring Raptor Simulator (SSRS), in a new geographic locale, to understand facility scale eagle movement patterns over time scales representative of a wind project's lifetime. For this desktop analysis (that does not depend on any high-performance computing resources), SSRS simultaneously considers a variety of wind conditions and eagle approach vectors toward a project site of interest. This work demonstrates the integration of publicly available landscape-scale atmospheric datasets, our recently improved engineering updraft models (see presentation from Thedin et al.), and our energy minimization behavioral models within the SSRS framework. While we only present results from a single behavioral model, the integration of these three modeling components forms the foundation for our more sophisticated behavioral models (see presentations from Brandes et al., Sandhu et al.) that are under active development. Results are presented in the form of presence maps, which may be applied to estimate risk to wildlife, augment ground survey data, inform wind-plant operations, or incorporated into wind-plant designs.

agent-based modeling↗

Protection from ground faults in the stator winding of generators at power plants in the Siberian networks

The experience of many years of experience in developing and utilization of ground fault protection in the stator winding of generators in the Siberian networks is generalized. The main method of protection is to apply a direct current or an alternating current with a frequency of 25 Hz to the primary circuits of the stator. A direct current is applied to turbo generators operating in a unit with a transformer without a resistive coupling to the external grid or to other generators. Applying a 25 Hz control current is appropriate for power generation systems with compensation of a capacitive short circuit current to ground. This method forms the basis for protection of generators operating on busbars, hydroelectric generators with a neutral grounded through an arc-suppression reactor, including in consolidated units with generators operating in parallel on a single low-voltage transformer winding.

42 ENGINEERING↗

Extracting single fiber transverse and shear moduli from off-axis misalignment fiber tensile testing

Small diameter (<100 μm) fibers (e.g. carbon fibers, Kevlar, and fiberglass) and wires (e.g. ultrafine copper and aluminum wires) are frequently used in many different engineering applications, such as for light weighting structures, electromagnetic shielding for aircraft/infrastructure/EVs, vibration damping, biological sensors, aerospace electrical devices, and electric windings just to name a few. Due to the manufacturing process, the fibers and wires are pulled and stretched to produce a preferential alignment. Therefore, thin fibers and wires typically display different properties along the length of the fiber as opposed to their cross section and many fibers/wires are considered transversely isotropic. The axial properties of fibers/wires can be ascertained via tensile testing of single-filaments or fiber tows, but the radial properties require much more effort to measure. Knowing these properties is important for the accurate prediction of micromechanical models and manipulation of fibers during micromanufacturing. In this paper, a new technique was developed to determine the transverse/shear moduli and strength of a material by conducting tensile tests of the material at increasing misalignment angles from the tensile axis. Due to the transversely isotropic nature of the material, the transverse/shear moduli and strength influence the experimental results recorded by the test machine to different degrees based on the amount of misalignment in the test setup. An equation was derived to determine the influence of each of the material properties based on the misalignment angle by manipulating the stiffness matrix for transversely isotropic materials using the transformation matrices. Then, curve fitted coefficients were used to identify the material properties. Here, the strengths were similarly determined by curve fitting an off-axis Tsai-Hill failure criteria to determine the influence of transverse, shear, and tensile strengths based on the complex loading condition provided by the off-axis tensile test. Zoltek Panex 35 carbon fibers were used to demonstrate this new technique and the determined properties were then compared to those obtained from nanoindentation and from literature. Fracture surfaces provide insight into the different failure mechanisms at various misalignment angles.

36 MATERIALS SCIENCE↗

Performance assessment of 700-bar compressed hydrogen storage for light duty fuel cell vehicles

In this study, type 4 700-bar compressed hydrogen storage tanks were modeled using ABAQUS. The finite element model was first calibrated against data for 35-L subscale test tanks to obtain the composite translation efficiency, and then applied to full sized tanks. Two variations of the baseline T700/epoxy composite were considered in which the epoxy was replaced with a low cost vinyl ester resin and low cost resin with an alternate sizing. The results showed that the reduction in composite weight was attributed primarily to the lower density of the resin and higher fiber volume fraction in the composite due to increased squeeze-out with the lower viscosity vinyl ester resin. The system gravimetric and volumetric capacities for the onboard storage system that holds 5.6 kg H 2 are 4.2 wt% (1.40 kWh/kg) and 24.4 g-H 2 /L (0.81 kWh/L), respectively. The system capacities increase and carbon fiber requirement decreases if the in-tank amount of unrecoverable hydrogen is reduced by lowering the tank "empty" pressure. Models of an alternate tank design showed potential 4-7% saving in composite usage for tanks with a length-to-diameter (L/D) ratio of 2.8-3.0 but no saving for L/D of 1.7. Lastly, a boss with smaller opening and longer flange does not appear to reduce the amount of helical windings.

08 HYDROGEN↗

Dual coil ignition system

A dual coil ignition system is provided. The dual coil ignition system includes a first inductive ignition coil including a first primary winding and a first secondary winding, and a second inductive ignition coil including a second primary winding and a second secondary winding, the second secondary winding connected in series to the first secondary winding. The dual coil ignition system further includes a diode network including a first diode and a second diode connected between the first secondary winding and the second secondary winding.

33 ADVANCED PROPULSION SYSTEMS↗

A review of modelling techniques for floating offshore wind turbines

Modelling floating offshore wind turbines (FOWTs) is challenging due to the strong coupling between the aerodynamics of the turbine and the hydrodynamics of the floating platform. Physical testing at scale is faced with the additional challenge of the scaling mismatch between Froude number and Reynolds number due to working in the two fluid domains, air and water. In the drive for cost-reduction of floating wind energy, designers may be seeking to move towards high-fidelity numerical modelling as a substitute for physical testing. However, the numerical engineering tools typically used for FOWT modelling are considered as mid-fidelity to low-fidelity tools, and currently lack the level of accuracy required to do so. Furthermore, there is a lack of operational FOWT data available for further development and validation. High-fidelity tools, such as CFD, have greater accuracy but are cumbersome tools and still require validation. Physical scale model testing therefore continues to play an essential role in the development of FOWTs both as a source of validation data for numerical models and as an important development step along the path to commercialization of all platform concepts. The aim of this paper is to provide an overview of both numerical modelling and physical FOWT scale model testing approaches and to provide guidance on the selection of the most appropriate approach (or combination of approaches). The current state-of-the-art will be discussed along with current research trends and areas for further investigation.

17 WIND ENERGY↗

Technical Assessment for the CPC FD-7x-1500 Wind Turbine located at Tooele Army Base, Tooele Utah

The CPC FD-7x-1500 Wind Turbine was installed with funding from the Energy Conservation Investment Program (ECIP). Since its installation, the turbine has been plagued with multiple operational upsets causing unacceptable down time. In an effort to reduce down time, the Army Corps of Engineers requested the Idaho National Laboratory conduct an assessment of the turbine to determine its viability as an operational turbine.

17 WIND ENERGY↗

Establishment of Small Wind Regional Test Centers: Preprint

The rapid growth of the small wind turbine (SWT) market is attracting numerous entrants. Small wind turbine purchasers now have many options but often lack information (such as third-party certification) to select a quality turbine. Most SWTs do not have third-party certification due to the expense and difficulty of the certification process. Until recently, the only SWT certification bodies were in Europe. In North America, testing has been limited to a small number of U.S. Department of Energy (DOE) subsidized tests conducted at the National Wind Technology Center (NWTC) under the ongoing Independent Testing Project. Within the past few years, the DOE, National Renewable Energy Lab (NREL), and some states have worked with the North American SWT industry to create a SWT certification infrastructure. The goal is to increase the number of certified turbines and gain greater consumer confidence in SWT technology. The American Wind Energy Association (AWEA) released the AWEA Small Wind Turbine Performance and Safety Standard (AWEA Standard 9.1 - 2009) in December 2009. The Small Wind Certification Council (SWCC), a North American certification body, began accepting applications for certification to the AWEA standard in February 2010. To reduce certification testing costs, DOE/NREL is providing financial and technical assistance for an initial round of tests at four SWT test sites which were selected via a competitive solicitation. The four organizations selected are Windward Engineering (Utah), The Alternative Energy Institute at West Texas A&M (Texas), a consortium consisting of Kansas State University and Colby Community College (Kansas), and Intertek (New York). Each organization will test two small wind turbines as part of their respective subcontract with DOE/NREL. The testing results will be made publically available. The goal is to establish a lower-cost U.S. small wind testing capability that will lead to increased SWT certification.

17 WIND ENERGY↗

CFD MODELING AND ANALYSIS FOR A-AREA AND H-AREA COOLING TOWERS

Mechanical draft cooling towers are designed to cool process water via sensible and latent heat transfer to air. Heat and mass transfer take place simultaneously. Heat is transferred as sensible heat due to the temperature difference between liquid and gas phases, and as the latent heat of the water as it evaporates. Mass of water vapor is transferred due to the difference between the vapor pressure at the air-liquid interface and the partial pressure of water vapor in the bulk of the air. Equations to govern these phenomena are discussed here. The governing equations are solved by taking a computational fluid dynamics (CFD) approach. The purpose of the work is to develop a three-dimensional CFD model to evaluate the flow patterns inside the cooling tower cell driven by cooling fan and wind, considering the cooling fans to be on or off. Two types of the cooling towers are considered here. One is cross-flow type cooling tower located in A-Area, and the other is counterflow type cooling tower located in H-Area. The cooling tower located in A-Area is mechanical draft cooling tower (MDCT) consisting of four compartment cells as shown in Fig. 1. It is 13.7m wide, 36.8m long, and 9.4m high. Each cell has its own cooling fan and shroud without any flow communications between two adjacent cells. There are water distribution decks on both sides of the fan shroud. The deck floor has an array of about 25mm size holes through which water droplet falls into the cell region cooled by the ambient air driven by fan and wind, and it is eventually collected in basin area. As shown in Fig. 1, about 0.15-m thick drift eliminator allows ambient air to be humidified through the evaporative cooling process without entrainment of water droplets into the shroud exit. The H-Area cooling tower is about 7.3 m wide, 29.3 m long, and 9.0 m high. Each cell has its own cooling fan and shroud, but each of two corner cells has two panels to shield wind at the bottom of the cells. There is some degree of flow communications between adjacent cells through the 9-in gap at the bottom of the tower cells as shown in Fig. 2. Detailed geometrical dimensions for the H-Area tower configurations are presented in the figure. The model was benchmarked and verified against off-site and on-site test results. The verified model was applied to the investigation of cooling fan and wind effects on water cooling in cells when fans are off and on. This report will discuss the modeling and test results.

42 ENGINEERING↗

Experimental Investigation of the Power Generation Performance of Floating-Point Absorber Wave Energy Systems: Preprint

The extraction of energy from ocean waves has gained interest in recent years. The floating-point absorber (FPA) is one of the most promising devices among a wide variety of wave energy conversion technologies. Early theoretical studies mainly focused on understanding the hydrodynamics of the system and on predicting the maximum power that could be extracted by a heaving body. These studiesevolve from the investigation of floating-body interactions in offshore engineering and naval architecture disciplines. To our best knowledge, no systematic study has been reported about the investigation of the power generation performance of an FPA with a close-to-commercial design. A series of experimental tests was conducted to investigate the power extraction performance of an FPA system.

17 WIND ENERGY↗

Offshore Wind Plant Balance-of-Station Cost Drivers and Sensitivities (Poster)

With Balance of System (BOS) costs contributing up to 70% of the installed capital cost, it is fundamental to understanding the BOS costs for offshore wind projects as well as potential cost trends for larger offshore turbines. NREL developed a BOS model using project cost estimates developed by GL Garrad Hassan. Aspects of BOS covered include engineering and permitting, ports and staging, transportation and installation, vessels, foundations, and electrical. The data introduce new scaling relationships for each BOS component to estimate cost as a function of turbine parameters and size, project parameters and size, and soil type. Based on the new BOS model, an analysis to understand the non-turbine costs associated with offshore turbine sizes ranging from 3 MW to 6 MW and offshore wind plant sizes ranging from 100 MW to 1000 MW has been conducted. This analysis establishes a more robust baseline cost estimate, identifies the largest cost components of offshore wind project BOS, and explores the sensitivity of the levelized cost of energy to permutations in each BOS cost element. This presentation shows results from the model that illustrates the potential impact of turbine size and project size on the cost of energy from US offshore wind plants.

17 WIND ENERGY↗