Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage prediction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Silicon device performance measurements to support temperature range enhancement

Silicon based power devices can be used at 200 C. The device measurements made during this program show a predictable shift in device parameters with increasing temperature. No catastrophic or abrupt changes occurred in the parameters over the temperature range. As expected, the most dramatic change was the increase in leakage currents with increasing temperature. At 200 C the leakage current was in the milliAmp range but was still several orders of magnitude lower than the on-state current capabilities of the devices under test. This increase must be considered in the design of circuits using power transistors at elevated temperature. Three circuit topologies have been prototyped using MOSFET's and IGBT's. The circuits were designed using zero current or zero voltage switching techniques to eliminate or minimize hard switching of the power transistors. These circuits have functioned properly over the temperature range. One thousand hour life data have been collected for two power supplies with no failures and no significant change in operating efficiency. While additional reliability testing should be conducted, the feasibility of designing soft switched circuits for operation at 200 C has been successfully demonstrated.

Bromstead, James↗

Predicting Deposition Rate and Closing the Loop on Aerosol Jet Printing with In‐Line Light Scattering Measurements

Aerosol jet printing is a compelling noncontact, digital manufacturing technology for flexible, hybrid, and conformal electronics, but batch‐to‐batch variability and process drift inhibit systematic study and translation to production environments. Emerging measurement techniques for the aerosol volume fraction, a key parameter governing deposition rate, have shown promise for real‐time response, including a recent demonstration of human‐in‐the‐loop control. By integrating improved light scattering measurements with custom software, a robust environment for real‐time monitoring is established and fully automated closed‐loop control over the deposition rate during printing is enabled. The physical basis for scattering measurements as a feedback source is examined and the quantitative insight this provides for ink development and fundamental process studies is highlighted. Three candidate process variables for closed‐loop control, namely the atomizer voltage, carrier gas flow rate, and print speed, are then evaluated. The atomizer voltage demonstrates the best extended duration validity because it addresses atomization variability directly, but carrier gas flow rate and print speed provide faster and more deterministic responses. This methodology is then demonstrated for electrical properties using a silver nanoparticle ink, maintaining 98% of printed patterns within 10% of the mean resistance value over 3 h of printing.

36 MATERIALS SCIENCE↗

Carbonate Management to Enable Energy- and Carbon-Efficient CO 2 Electrolysis (Final Technical Report)

The rapid growth and plummeting cost of solar energy have spurred growing interest in using CO 2 electrolysis to produce chemicals and fuels as an alternative to conventional petrochemical processes. High-temperature (>800 °C) solid oxide electrolyzers that convert CO 2 into CO and O 2 have recently become commercially available. Low-temperature electrolysis cells offer the prospect of more convenient and flexible operation, which is critical for utilizing intermittent solar energy, and provide access to more valuable C 2+ products such as ethylene, ethanol, and propanol. Over the past 10 years, research in this area has yielded substantial progress in both fundamental understanding of the requisite electrocatalytic reactions and design of prototype devices. Leveraging insights from fuel cells and membrane water electrolyzers, researchers have developed electrolysis cells with gas diffusion electrodes (GDE) that have demonstrated high CO 2 electrolysis current densities (>100 mA cm –2 ) as well as promising selectivity and stability. Despite these advances, the energy efficiency (electrical energy-to-product) and carbon efficiency (CO 2 -to-product) of low-temperature CO 2 electrolysis remain far too low for large-scale deployment. A preponderance of evidence indicates that the principal source of efficiency losses is the rapid and thermodynamically favorable reaction of CO 2 with hydroxide (OH – ) to form carbonate (CO 3 2– ). Carbonate formation imposes steady-state electrolysis conditions that result in large voltage and CO 2 losses for all known (photo)electrochemical CO 2 cells. While much current research remains focused on CO 2 reduction catalyst design, this largely overlooked CO 3 2– problem presents a fundamental scientific barrier to creating a viable electrochemical option for converting solar energy into chemicals and fuels. The project pursues an integrated, multi-PI research effort that establishes a fundamental science of CO 3 2– management. PI Kanan and Co-PI Mani’s contribution to the project is to evaluate strategies to mitigate the CO 3 2– problem by changing the properties of the electrolyte and the environment in which CO 2 reduction catalysis takes place. Experimental studies showed that electrolytes composed of a high concentration of both CO 3 2– and HCO 3 – , which serve as moderately alkaline buffers, improved the cell voltage by compared to all-HCO 3 – electrolytes, but these buffered systems still show substantial CO 2 uptake that reduces pH over time. Computational studies developed a homogenized model of a CO 2 reduction catalyst layer that permits a low-cost exploration of the high-dimensional parameter space associated with catalyst layers on gas diffusion electrodes. The model was validated by accurately reproducing experimental data for the related but simpler reaction of CO reduction and then used to probe the effects of catalyst layer architecture on CO 2 reduction. Minimizing the size of catalyst and hydrophobic domains in the catalyst layer is predicted to mitigate CO 3 2– formation and thereby enable prolonged operation at elevated pH. In support of the CO 2 electrolysis studies, a new method for rapidly prototyping electrochemical cells was developed and validated. The method uses a combination of 3D printing and electroless plating to generate conductive cell components for evaluating new cell designs. The carbonate problem encompasses mass transport processes and acid-base reactions that are relevant to many other electrochemical systems. Investigation of strategies to address the carbonate problem led to an additional line of inquiry into the physicochemical phenomena that determine the efficiency of electrochemical acid-base production, which has numerous applications in the broader field of carbon management. New strategies for using the supporting electrolyte to inhibit H + /OH – recombination in electrochemical acid-base production were evaluated, leading to the development of a novel acid-base producing system that eliminates the need for ion exchange membranes and exhibits promising efficiency and current densities for scalable applications.

25 ENERGY STORAGE↗

Charge-Based Droop Control Addressing Control Saturation for Low-Inertia Converters

With bulky dc-link capacitors/inductors, traditional voltage-source converters (VSCs) and current-source converters (CSCs) feature a large inertia to facilitate the converter control under large transients. To achieve high power density with reduced cost, low-inertia converters (LICs) featuring significantly reduced dc-link capacitors/inductors have attracted growing attention. However, without bulky dc-link energy buffer, LICs are prone to control saturation under large transients, resulting in undesired oscillation and instability. This issue cannot be managed by traditional proportional-integral based control due to the low inertia. And it will deteriorate when several LICs are connected in series. To address this challenge in LICs, a model-predictive control (MPC) with a computation-inexpensive feed-forward compensation method has been proposed to provide fast dynamic responses. But it would suffer control saturation under larger transients that degrades the control performance. In this article, a charge-based droop control (CDC) is proposed to address this remaining challenge. This paper firstly analyzes the control saturation challenge in LICs by using a tri-port soft-switching solid-state transformer as an example. Next, the operating principle of the proposed CDC are introduced. Two different implementation approaches are discussed in detail. Lastly, the proposed scheme is validated in simulation with a high-fidelity model of hardware prototype. As a result, the proposed CDC eliminated the 2 kHz oscillation and reduced the dc-link ripple and overshoot due to control saturation by 75% and 50%, respectively.

30 DIRECT ENERGY CONVERSION↗

Theoretical performance of multi-layer grid patterns for solar cells

Multilayer grid patterns consist of fine closely spaced grid lines overlaid by coarser patterns of wider and thicker grid lines to collect the current from the finer grids with low series voltage drop and low active-layer sheet losses. An analytical approach leads to closed form solutions with simple relationships between the power losses in the active layer, in the grid and shadowing losses for optimum design proportions. The results show that multilayer grids, with line thickness equal to line width, greatly reduce losses in cell efficiency under concentration conditions of high current collection. (AlGa)As-pn GaAs cells of areas 1-25 sq cm and sheet resistance 40 ohms/square are considered. Also the performance of a n/p GaAs cell of dimensions 10 x 10 cm is studied. With optimized grid patterns high efficiencies are predicted for large area cells.

Flat, A.↗

Atomically dispersed single iron sites for promoting Pt and Pt 3 Co fuel cell catalysts: performance and durability improvements

Significantly reducing platinum group metal (PGM) loading while improving catalytic performance and durability is critical to accelerating proton-exchange membrane fuel cells (PEMFCs) for transportation. In this study, we report an effective strategy to boost PGM catalysts through integrating PGM-free atomically-dispersed single metal active sites in the carbon support toward the cathode oxygen reduction reaction (ORR). We achieved uniform and fine Pt nanoparticle (NP) (~2 nm) dispersion on an already highly ORR-active FeN 4 site-rich carbon (FeN 4 –C). Furthermore, we developed an effective approach to preparing a well-dispersed and highly ordered L1 2 Pt 3 Co intermetallic nanoparticle catalyst on the FeN 4 –C support. DFT calculations predicted a synergistic interaction between Pt clusters and surrounding FeN 4 sites through weakening O 2 adsorption by 0.15 eV on Pt sites and reducing activation energy to break O–O bonds, thereby enhancing the intrinsic activity of Pt. Experimentally, we verified the synergistic effect between Pt or Pt 3 Co NPs and FeN 4 sites, leading to significantly enhanced ORR activity and stability. Especially in a membrane electrode assembly (MEA) with a low cathode Pt loading (0.1 mg Pt cm –2 ), the Pt/FeN 4 –C catalyst achieved a mass activity of 0.451 A mg Pt –1 and retained 80% of the initial values after 30 000 voltage cycles (0.60 to 0.95 V), exceeding DOE 2020 targets. Furthermore, the Pt 3 Co/FeN 4 catalyst achieved significantly enhanced performance and durability concerning initial mass activity (0.72 A mg Pt –1 ), power density (824 mW cm –2 at 0.67 V), and stability (23 mV loss at 1.0 A cm –2 ). The approach to exploring the synergy between PGM and PGM-free Fe–N–C catalysts provides a new direction to design advanced catalysts for hydrogen fuel cells and various electrocatalysis processes.

25 ENERGY STORAGE↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

A Study of the Measurement of Seebeck Coefficient of SiGe

In 1821 German Physicist Thomas J. Seebeck discovered that heat could be converted into electricity when a temperature difference was applied across two points on a material. Theoretically, the generated voltage has a directly proportional relationship with the temperature difference. This relationship is the Seebeck coefficient that scientists always referred to when determining the efficiency of a thermoelectricity convention. In our experiments, however, hysteresis loops appeared when we plotted voltage against temperature difference, and the measured Seebeck appeared differently when the measurements were run under vacuum, air, and helium gas. Measurements were done by using a low-frequency AC measuring method. By simulating the experimental setup into a; thermal circuit, we found that the loop and inconsistency in measuring Seebeck coefficient could be explained by studying the behaviors of a RC circuit in a thermal sense. Under vacuum, the gap of the hysteresis loop can be largely eliminated if the time period of the temperature difference increased up to 4800s. The trend of the variations in measuring Seebeck coefficients in different environments can also be predicted by using different thermal circuit models.

Heung, King Yi↗

Studies in geophysics: The Earth's electrical environment

The Earth is electrified. Between the surface and the outer reaches of the atmosphere, there is a global circuit that is maintained by worldwide thunderstorm activity and by upper atmospheric dynamo processes. The highest voltages approach a billion volts and are generated within thunderclouds, where lightning is a visual display of the cloud's electrical nature. The largest currents in the circuit, approaching a million amperes, are associated with the aurora. Because there have been significant advances in understanding many of the component parts of the global electric circuit (lightning, cloud electrification, electrical processes in specific atmospheric regions, and telluric currents), a principal research challenge is to understand how these components interact to shape the global circuit. Increased basic understanding in this field has many potential practical applications, including lightning protection, the design of advanced aircraft and spacecraft, and improvements in weather prediction.

Source record↗

Neutralizer Hollow Cathode Simulations and Validation with Experiments

The fidelity of electric propulsion physics-based models depends largely on the validity of their predictions over a range of operating conditions and geometries. In general, increased complexity of the physics requires more extensive comparisons with laboratory data to identify the region(s) that lie outside the validity of the model assumptions and to quantify the uncertainties within its range of application. This paper presents numerical simulations of neutralizer hollow cathodes at various operating conditions and orifice sizes. The simulations were performed using a two-dimensional axisymmetric model that solves numerically a relatively extensive system of conservation laws for the partially-ionized gas in these devices. The results for the plasma are compared directly with Langmuir probe measurements. The computed keeper voltages are also compared with the observed values. Wherever model inputs and/or specific physics of the cathode discharge are uncertain, additional sensitivity calculations have been performed to quantify the uncertainties.

partially ionized gases↗

Collaborative Research: Unravelling the Physics Associated with the Production of Extremely Dense Plasma States of Microscale (Final Report) Nanosecond-pulsed Discharges

The aim of this project is to study and establish the physical mechanisms that contribute to the formation of anomalously dense plasmas in high-pressure nanosecond-pulsed discharges. These discharges have a broad range of applications such as plasma-assisted combustion, plasma flow actuators, biomedical sterilization and exotic materials synthesis. The structure and formation of these discharges, producing high plasma densities of ~10 14 -10 15 cm -3 , are well-studied and understood. Fast-pulsed microscale high-pressure discharges can be driven to even higher densities of > 10 19 cm -3 , approaching warm dense matter conditions. The mechanisms that generate these plasmas have not been understood. Analysis of the warm dense matter state under laboratory conditions is an expensive and non-trivial endeavor. For instance, dense plasmas can be generated by electrical explosions of metal foils and wires. Plasmas generated after the explosion have a short lifetime and often present difficult conditions for diagnostics. Generation of dense plasmas was also achieved during high-voltage nanosecond pulsed discharges when the so-called explosive electron emission is obtained. Unfortunately, this process is very difficult to control for the studies of warm dense matter. In our recent study, we have shown that additional heating of plasma by lasers can further increase the density of plasma and even lead to the fully ionized state. This method, potentially, allows better control of the plasma parameters. In this work, we studied a second stage laser-heated micro-discharge using a self-consistent one-dimensional particle-in-cell Monte Carlo-collision (1D PIC-MCC) model coupled with Maxwell’s equations. We predicted the generation of a fully ionized plasma on the picosecond time scale. However, this model considered the plasma as an ideal gas despite the high pressure and the nearly fully ionized state. The ideal plasma model assumes that the dilute gas approximation is valid, where the inter-particle interactions are negligible. For charged particles this assumption holds as long as the shielded Coulomb potential assumption is valid. For very high plasma densities, this concept breaks down since the Debye sphere surrounding each charged particle no longer contains enough electrons to statistically provide the shielding of the single particle Coulomb interaction potential. At such densities, the plasma can no longer be described as ideal and non-ideal coupling effects need to be considered. In this report, we elucidate our recent work of developing a PIC-MCC model with improvements for non-ideal plasma conditions due to Coulomb coupling at high densities. In particular, we study the interaction of green light radiation and a dense microplasma, and explore the non-ideal plasma effects in this interaction. In this computational model, we implement the two most important non-ideal effects: ionization potential depression (IPD) and enhanced collision cross sections. Our primary goal is to study the physics associated with electromagnetic (EM) wave heating, also called the second-stage wave-heating, and establish the role of plasma non-ideality in this phenomenon. Our secondary goal is to improve the chemistry mechanism of the 1D PIC-MCC model by including a more detailed excited species collision treatment. At high pressures, stepwise ionization from excited species might play an important role in the ionization process. Previously, this ionization mechanism was neglected due to the excitation collision cross section of xenon being smaller than that of ionization. However, a preliminary study showed that the excited species density in the initial microplasma was an order of magnitude higher than the electron density. Therefore, my aim is to determine the significance of this additional ionization pathway to the plasma generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NEXT Long-Duration Test After 11,570 h and 237 kg of Xenon Processed

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation ion propulsion system with significant enhancements beyond the state-of-the-art in ion propulsion to provide future NASA science missions with enhanced mission capabilities at a low total development cost. As part of a comprehensive thruster service life assessment utilizing both testing and analyses, a Long-Duration Test (LDT) was initiated to validate and qualify the NEXT propellant throughput capability to a qualification-level of 450 kg, 1.5 times the mission-derived throughput requirement of 300 kg. This wear test is being conducted with a modified, flight-representative NEXT engineering model ion thruster, designated EM3. As of September 1, 2007, the thruster has accumulated 11,570 h of operation primarily at the thruster full-input-power of 6.9 kW with 3.52 A beam current and 1800 V beam power supply voltage. The thruster has processed 237 kg of xenon surpassing the NSTAR propellant throughput demonstrated during the extended life testing of the Deep Space 1 (DS1) flight spare. The NEXT LDT has demonstrated a total impulse of 9.78 10(exp 6) N(dot)s; the highest total impulse ever demonstrated by an ion thruster. Thruster performance tests are conducted periodically over the entire NEXT throttle table with input power ranging 0.5 to 6.9 kW. Thruster performance parameters including thrust, input power, specific impulse, and thruster efficiency have been nominal with little variation to date. Lifetime-limiting component erosion rates have been consistent with the NEXT service life assessment, which predicts the earliest failure sometime after 750 kg of xenon propellant throughput; well beyond the mission-derived lifetime requirement. The NEXT wear test data confirm that the erosion of the discharge keeper orifice, enlarging of nominal-current-density accelerator grid aperture cusps at full-power, and the decrease in cold grid-gap observed during NSTAR wear testing have been mitigated in the NEXT design. NEXT grid-gap data indicate a hot grid-gap at full-power that is 60 percent of the nominal cold grid-gap. This paper presents the status of the NEXT LDT to date with emphasis on comparison to the NSTAR extended life test results.

Soulas, George C.↗

Semiclassical model for calculating exciton and polaron pair energetics at interfaces

Exciton and polaron pair dissociation is a key functional aspect of photovoltaic devices. To improve upon the current state of interfacial transport models, we augment the existing classical models of dielectric interfaces by incorporating results from ab initio calculations, allowing us to calculate exciton and polaron binding energies more accurately. We demonstrate the predictive capabilities of this new model using two interfaces: (i) the boron subphthalocyanine chloride (SubPc) and C60 interface, which is an archetype for many organic photovoltaic devices; and (ii) pentacene and silicon (1 0 0), which represents a hybrid between organic and inorganic semiconductors. Overall, our calculations predict that the insertion of molecular dipoles at interfaces can be used for improving polaron pair dissociation and that sharp transitions in dielectric permittivity can have a stronger effect on the polaron pair dissociation than even the electron-hole Coulomb interaction.

36 MATERIALS SCIENCE↗

Plasma production and ion heating systems for the Material Plasma Exposure eXperiment

Plasma production and ion heating in the Material Plasma Exposure eXperiment (MPEX), whose design is nearing completion, is accomplished using continuous wave RF power with average power density up to 1.6 MW/m2 at the plasma interface. Plasma is produced using helicon waves coupled through a single helical antenna at 13.56 MHz with power supplied by three 100 kW fixed-frequency RF generators feeding a power combiner network followed by the matching network and launcher. The helicon source can utilize various gasses including hydrogen, deuterium, and helium, with a magnetic field strength in the source region up to 0.2 T, and maximum device |B| of 2.5 T. Power is coupled to ions via ion cyclotron heating at the fundamental resonance using a pair of phased helical antennas operating in the frequency range 4-9 MHz, that launch waves towards the resonance from the antenna region where ω > ωci. ICH power is supplied by a single 500 kW tunable RF transmitter through a 90° power splitter and matching/decoupling network. In the case of both the helicon and ICH systems the antennas are located external to the vacuum, with power transferred through novel water-cooled coaxial vacuum windows consisting of fused quartz outer cylinders and silicon nitride inner cylinders with forced convection water cooling between them. The antenna enclosures are pressurized with dry air to 3 bar absolute for voltage standoff.Several 3-D COMSOL models have been created to simulate the two systems. A model of the helicon region utilizing a cold plasma dielectric tensor with accurate magnetic field and realistic plasma density profiles has been used to calculate the plasma loading/complex antenna input impedance at the launcher feed for various ne and |B| values, for the purpose of estimating power handling. It also incorporates the geometry of all launcher structures relevant to this determination. A still more detailed model of the launcher together with a lossy dielectric plasma surrogate has been used to determine RF electric field values and power losses in the device components.Similar models have been produced to predict the performance and power handling of the ICH launcher. For this device the impedance matrix of the two-element antenna array is calculated using a warm plasma model, necessary to properly determine the wave propagation and absorption.

Goulding, Richard↗

Review of biased solar array - Plasma interaction studies

Possible high voltage surface interactions on the Solar Electric Propulsion System (SEPS) are examined, with particular regard for potential effects on SEPS performance. The SEPS is intended for use for geosynchronous and planetary missions, and derives power from deployed solar cell arrays which are susceptible to collecting ions and electrons from the charged and thermal particle environment of space. The charge exchange plasma which provides the thrust force can also enhance the natural charged particle environment and increase interactions between the thrust system and the biased solar array surface. Tests of small arrays have shown that snapover, where current collection becomes proportional to the panel area, can be avoided by larger cell sizes. Arcing is predicted to diminish with larger array sizes, while the problems of efflux environments are noted to be as yet undefined and require further study.

Stevens, N. J.↗

A 3D porous honeycomb carbon as Na-ion battery anode material with high capacity, excellent rate performance, and robust stability

Motivated by the synthesis of three-dimensional (3D) honeycomb carbon structures and the subsequent theoretical prediction of an energetically more favorable hexagonal carbon phase composed of 28 carbon atoms in the unit cell (hC28) with ordered pores, excellent mechanical properties, and metallic feature, we explore its potential for a Na-ion battery (NIB) anode material. Using density functional theory based calculations, we find that hC28 is a promising candidate whose specific capacity of 717 mAh/g is almost three times larger than that of hard carbon (~250 mAh/g). In addition, migration barrier of Na ions along the honeycomb channel is only 0.08 eV and the volume change during the charging/discharging process is merely 2.30%, which are much less than those of other carbon-based NIB anode materials. The average voltage is also low (0.36 eV) which can provide high operating voltage when connected to the cathode. Finally, these encouraging results would pave the way towards the development of hC28 as NIB anode with high capacity, excellent rate performance, low open-circuit voltage, and long-term cycle life.

36 MATERIALS SCIENCE↗

Contactless measurement of the photovoltage in BiVO 4 photoelectrodes

The power output of photoelectrochemical devices for solar energy-to-fuel conversion is determined by the photovoltage of the junction under illumination. In the presence of fast redox couples, the photovoltage can be obtained directly from current–voltage measurements of the device. However, for slow redox couples (H + /H 2 , O 2 /H 2 O) used in solar fuel photoelectrodes, photovoltage measurements are not straightforward, due to the kinetic overpotentials during charge transfer. Here we show that the photovoltage of BiVO 4 electrodes in contact with fast electron donors KI, Na 2 SO 3 or H 2 O 2 or K 4 Fe(CN) 6 can be measured in a contactless way with vibrating Kelvin probe surface photovoltage (SPV) spectroscopy. The photovoltage varies with illumination wavelength and intensity and matches the open circuit potential of the electrodes, obtained separately from electrochemical measurements. Plots of the photovoltage versus irradiance can be used to predict the oxidizing power of each electrode under zero applied bias. Except for K 4 Fe(CN) 6 , which causes shunting in the BiVO 4 electrode, photovoltage values correlate well with the built-in potential of each junction. Furthermore, the ability to obtain photovoltage information through contactless SPV measurements will be useful in the search for solid–liquid junctions with superior energy conversion properties.

14 SOLAR ENERGY↗

Technical Impacts of Light-Duty and Heavy-Duty Transportation Electrification on a Coordinated Transmission and Distribution System

In this study, we propose a strategy to model the required spatiotemporal charging demand from light-duty (LD) and medium- and heavy-duty (MHD) electric vehicles (EVs) using actual transportation data by mapping the demand for the required EV charging to a realistic and coordinated distribution and transmission electric grid at the predicted times of the day to study their impact on the power system in a variety of load, weather, and EV penetration scenarios. This work is the first study that includes the actual weather data and transportation data with realistic and coordinated distribution and transmission grid data in a large industry-scale level study. The main goal of this study is to identify possible issues and required upgrades in the electric grid, caused by an increase in EV integration. The transmission case study is a large grid with 6717 buses over a Texas footprint, and the distribution grid is over Houston, a city in Texas, covering over three million customers. The resulting overloads and voltage violations experienced in the system are discussed, and required planning upgrades to avoid these issues are suggested.

AC optimal power flow (AC-OPF)↗