Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vibration data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

An Algorithm for Synthesizing Mass and Stiffness Matrices from Experimental Vibration Modes

An algorithm is described for synthesizing the mass and stiffness matrices from experimentally derived modal data in a way that preserves the physical significance of the individual mass and stiffness elements. The mass and stiffness matrices are derived for a rollup solar array example, and are then used to define the modal response of a modified array.

Ross, R. G., Jr.↗

Measurements and kinetic modeling of O 2 vibrational kinetics in O 2 –Ar mixtures partially dissociated by a Ns pulse discharge

Vibrational kinetics of O 2 is studied during the O atom recombination in an O 2 –Ar mixture, partially dissociated by a burst of ns discharge pulses in a heated plasma flow reactor. The time-resolved temperature in the discharge afterglow is determined by Rayleigh scattering. Time-resolved O atom number density is measured by ps Two-Photon absorption Laser Induced Fluorescence, calibrated in xenon. Time-resolved vibrational level populations of molecular oxygen, O 2 (v= 8–20), are measured by ps Laser Induced Fluorescence (LIF), with the absolute calibration by NO LIF. Time-resolved ozone number density is monitored by broadband UV absorption. The results are compared with the predictions of a state-specific kinetic model. The experimental data indicate a rapid initial decay of O 2 (v) populations generated by electron impact in the discharge, due to the vibration-translation (V–T) relaxation by O atoms. This is followed by a slower population reduction, on the time scale much longer compared to that for V–T relaxation or vibration-vibration (V–V) exchange. Both O atoms and the O 2 (v) populations decay on the same time scale, indicating that chemical reactions initiated by the O atom recombination result in the generation of vibrationally excited O 2 molecules. These trends are reproduced by the kinetic model, which shows that the reaction of O atoms with ozone is the dominant pathway of O 2 (v) generation at the present conditions. The predicted relative O 2 (v) populations are close to the experimental results, but absolute number densities differ from the experimental data. This is likely due to uncertainties in the absolute calibration of LIF measurements and in the spectroscopic model used in the data reduction. The present work demonstrates the capability for the absolute, time-resolved measurements of vibrationally excited O 2 in recombining gas flows, to quantify the energy partition in the recombination reactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and theoretical investigation for the suppression of the plasma arc drop in the thermionic converter

Ion generation and recombination mechanisms in the cesium plasma as they pertain to the advanced mode thermionic energy converter were studied. The decay of highly ionized cesium plasma was studied in the near afterglow to examine the recombination processes. Very low recombination in such a plasma may prove to be of considerable importance in practical converters. The approaches of external cesium generation were vibrationally excited nitrogen as an energy source of ionization of cesium ion, and microwave power as a means of resonant sustenance of the cesium plasma. Experimental data obtained so far show that all three techniques - i.e., the non-LTE high-voltage pulsing, the energy transfer from vibrationally excited diatomic gases, and the external pumping with a microwave resonant cavity - can produce plasmas with their densities significantly higher than the Richardson density. The implication of these findings as related to Lam's theory is discussed.

Shaw, D. T.↗

Data Analysis for the NASA/Boeing Hybrid Laminar Flow Control Crossflow Experiment

The Hybrid-Laminar Flow Control (HLFC) Crossflow Experiment, completed in 1995. generated a large database of boundary layer stability and transition data that was only partially analyzed before data analysis was abruptly ended in the late 1990's. Renewed interest in laminar flow technologies prompted additional data analysis, to integrate all data, including some post-test roughness and porosity measurements. The objective is to gain new insights into the effects of suction on boundary layer stability. A number of challenges were encountered during the data analysis, and their solutions are discussed in detail. They include the effect of the probe vibration, the effect of the time-varying surface temperature on traveling crossflow instabilities, and the effect of the stationary crossflow modes on the approximation of wall location. Despite the low turbulence intensity of the wind tunnel (0.01 to 0.02%), traveling crosflow disturbances were present in the data, in some cases at amplitudes up to 1% of the freestream velocity. However, the data suggests that transition was dominated by stationary crossflow. Traveling crossflow results and stationary data in the presence of suction are compared with linear parabolized stability equations results as a way of testing the quality of the results.

Eppink, Jenna L.↗

Explainable AI (XAI)-driven vibration sensing scheme for surface quality monitoring in a smart surface grinding process

Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.

42 ENGINEERING↗

Reprint of: Explainable AI (XAI)-driven vibration sensing scheme for surface quality monitoring in a smart surface grinding process

Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.

47 OTHER INSTRUMENTATION↗

Dynamic Ligand Surface Chemistry of Excited PbS Quantum Dots

The ligand shell around colloidal quantum dots mediates the electron and energy transfer processes that underpin their use in optoelectronic and photocatalytic applications. In this work, we show that the surface chemistry of carboxylate anchoring groups of oleate ligands passivating PbS quantum dots undergoes significant changes when the quantum dots are excited to their excitonic states. Additionally, we directly probe the changes of surface chemistry using time-resolved mid-infrared spectroscopy that records the evolution of the vibrational frequencies of carboxylate groups following excitation of the electronic states. The data reveal a reduction of the Pb-O coordination of carboxylate anchoring groups to lead atoms at the quantum dot surfaces. The dynamic surface chemistry of the ligands may increase their surface mobility in the excited state and enhance the ability of molecular species to penetrate the ligand shell to undergo energy and charge transfer processes that depend sensitively on distance.

36 MATERIALS SCIENCE↗

Electroanalytical characterization of Np( VI )/Np( V ) redox in a pentadentate ligand environment and stabilization of [Np V O 2 ] + by hydrogen bonding

The redox chemistry of the actinyl cations (AnO 2 n+ ) heavily influences their reactivity and speciation in solution, but the redox properties of the actinyls in non-aqueous media have received far less attention than they deserve. Here, the non-aqueous electrochemistry of a chemically reversible Np(VI)/Np(V) redox manifold is reported in both protic (CH 3 OH) and aprotic (CH 3 CN) organic media. Using a neutral Np(VI) complex supported by a chelating and strongly donating pentadentate ligand that was fully characterized in prior work, a clean Np(VI)/Np(V) redox couple was found to be accessible under ambient conditions. Coupled electrochemical and spectroscopic studies, as well as simulations of cyclic voltammetry data, confirm the 1e− nature of this couple and establish it to be chemically reversible and nearly electrochemically reversible as well. Bulk electrolysis of a solution of the neutral Np(VI) complex facilitated isolation of the corresponding anionic and monomeric Np(V) species. Data from X-ray diffraction analysis as well as optical and vibrational spectroscopies provide strong evidence in support of metal-centered reduction and the Np(V) oxidation state, findings that are in accord with the measured reduction potentials. Distinctive hydrogen bonding interactions between the terminal (yl) oxo groups and water molecules appear to stabilize the isolated Np(V) species in the solid state, providing insight into the features that afford the uncommon chemically reversible redox encountered in this system.

Mikeska, Emily R.↗

Yield and PDV Measurements of the Godiva-IV Critical Assembly

A high dynamic range, scinillator based detector, the MHD-240, was used to measure the gamma and neutron flux of several prompt critical bursts of the Godiva-IV assembly. The measurements provided the alpha and FWHM for several different burst temperatures. Calibrations of the MHD240 gamma and neutron sensitivity along with MCNP based simulation of the Godiva-IV assembly allowed us to also determine the total fission yield of the burst integrated over approximately 5 ms. In addition a Photo Doppler Velocimetry measurement was conducted to determine the surface motion vibrational frequency of Godiva-IV assembly during the bursts. The combined data were collected to be used as input to multi-physics simulation of the Godiva-IV assembly. This is a preliminary report, there is an ongoing effort to update the MCNP simulations used in the analysis and develop a correction for the room return component of the measured signal.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A traverse gravimeter for the lunar surface

A semi-automatic, self-levelling lunar gravimeter was designed for the purpose of measuring gravity at predetermined stops along the route of a lunar rover vehicle to obtain a gravity profile. The traverse gravimeter is completely self-contained and is powered by an internal battery. The gravity sensor is a vibrating string accelerometer (VSA) which is enclosed in a precision oven. Gravity data are obtained by initiating a measurement. After the gravimeter has levelled, the VSA difference frequency is counted down and a gate is generated to enable a crystal-controlled clock to a BCD counter. The BCD counter stores the data which are a measurement of gravity. These data, displayed upon command by the astronaut, are transmitted by voice back to earth. It is expected that the accuracy of the gravimeter will be better than one milligal. Low power, light weight, reliability, and simplicity of operation are major considerations in the design of the gravimeter.

Mamon, G.↗

A traverse gravimeter for the lunar surface.

A semiautomatic, self-leveling lunar gravimeter has been designed for the purpose of measuring gravity at predetermined stops along the route of a Lunar Rover Vehicle to obtain a gravity profile. The Traverse Gravimeter is completely self-contained and is powered by an internal battery. The gravity sensor is a vibrating string accelerometer (VSA) which is enclosed in a precision oven. Gravity data are obtained by initiating a measurement. After the gravimeter has leveled, the VSA difference frequency is counted down and a gate is generated to enable a crystal-controlled clock to a BCD counter. The BCD counter stores the data which are a measurement of gravity. These data, displayed upon command by the astronaut, are transmitted by voice back to earth.

Mamon, G.↗

Discrete regulation of transfer function of a circuit in experimental data automatic collection and processing systems

A device for discrete control of the circuit transfer function in automatic analog data processing systems is reported that coordinates the dynamic range of the vibration level change with the signal range of the processing device output. Experimental verification of the device demonstrates that its maximum control speed does not exceed 0.5 sec for a frequency nonuniformity of about 10%.

Lyubashevskiy, G. S.↗

Flutter spectral measurements using stationary pressure transducers

Engine-order sampling was used to eliminate the integral harmonics from the flutter spectra corresponding to a case-mounted static pressure transducer. Using the optical displacement data, it was demonstrated that the blade-order sampling of pressure data may yield erroneous results due to the interference caused by blade vibration. Two methods are presented which effectively eliminate this interference yielding the blade-pressure-difference spectra. The phase difference between the differential-pressure and the displacement spectra was evaluated.

Kurkov, A. P.↗

On the use of coherence functions to evaluate sources of dynamic excitation

The use of coherence functions for identifying the relative contributions of multiple dynamic inputs to the measured vibration response of spacecraft components on a practical, complex structure was investigated. Data were generated by applying simultaneous vibratory and acoustic excitation to a test model (a modified Titan instrumentation truss). Up to three inputs were used. In some cases mutually coherent inputs were generated. A digital computer program was written to analyze the test data, using an approach based on iterative computational algorithms. The results showed that the coherence function technique was effective in identifying and evaluating sources of excitation, for both independent and coherent inputs. The effect of varying the number of data samples used in the necessary averaging process was briefly investigated.

Barrett, S.↗

Performance and loads data from a wind tunnel test of a full-scale, coaxial, hingeless rotor helicopter

A full-scale XH-59A advancing blade concept helicopter was tested in Ames Research Center's 40 by 80 foot wind tunnel. The helicopter was tested with the rotor on and off, rotor hub fairings on and off, interrotor shaft fairing on and off, rotor instrumentation module on and off, and auxiliary propulsion thrust on and off. An advance ratio range of 0.25 and 0.45 with the rotor on and from 60 to 180 knots with the rotor off was investigated. Data on aerodynamic forces and moments, rotor loads, rotor control positions and vibration for the XH-59A as well as the aerodynamic performance of the isolated rotor are presented.

Felker, F. F., III↗

Heterodyne frequency measurements of 13CO2 laser hot band transitions

Careful measurements by means of stabilized CO2 lasers are presented for the frequencies of 28 lines in the P-branch of the 01 0 0-(11 1 0, 03 1 0)I band of (C-13)(0-16)2, observed in laser emission, and three lines in the R-branch, observed in absorption with a diode laser. A significant improvement in the ro-vibrational constants has been obtained from a least squares fit to these data, demonstrating that the laser lines stabilized by natural absorption techniques provide convenient, accurate frequency references near 11.7 microns with an uncertainty of less than 0.1 MHz.

Petersen, F. R.↗

Thermal design of the Space Shuttle External Tank

The history of the engineering and manufacturing requirements leading to the final Thermal Protection System (TPS) for the External Tank (ET) is presented. The thermal design for the ET must be optimized, based on considerations of cost, weight, and application of the TPS. The significant thermal requirements include the structural and component temperature limits, the propellant quality, the minimization of ice and frost, no air liquefaction, and no film boiling. The TPS materials selected to meet the requirements are a low density closed cell foam (CPR-488) and two light-weight ablators (SLA-56 and MA-25s). The first four flights of the Space Shuttle (1981) will measure and evaluate external environmental, structural, propulsion, electrical, and engine performance data. The ET will be instrumented to measure acoustics, pressures, heat transfer, vibration, temperatures, and structural strains. TPS weight reductions are planned for future ETs through the use of a comprehensive thermal instrumentation system.

Warmbrod, J. D.↗