Long-life ball-valve design
Eccentric mounting of ball on stem reduces wear on valve seal.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Eccentric mounting of ball on stem reduces wear on valve seal.
A modulating valve device, operated by fluid pressure in fluid motors to control work pressure, is described.
The use of potassium dideuterium phosphate (DKDP) light valves for optical data processing is discussed. The operating principles and structure of optically and electron beam addressed DKDPs are compared, and specifications for both devices given. Optically addressed DKDPs are capable of higher resolution and contrast, but both systems represent viable real time spatial light modulators adaptable to optical processing. Examples of real time data processing performed by the DKDPs include: image addition and subtraction; reduction of noise introduced by scattered light in recording media; reconstruction of computer generated and acoustic holograms; reconstruction of synthetic aperture radar data; retrieval of three-dimensional information in X-ray diagnoses; radar signal processing and display; and optical pattern recognition and correlation of images, which has applications for missile guidance systems.
Device requires no moving parts and has less stringent tolerances. Device uses magnetostrictive powdered metal and electromagnets, rather than solenoid. Device is more reliable than conventional valves.
System allows removal and recertification of pressure-relief valve without compromising safety requirements or depressurizing pressure vessels.
Simpler design eliminating camshafts, cams, and mechanical springs should improve reliability of hydrazine powered reciprocating engines. Valve is expected to improve efficiency, and reduce weight of engines in range up to 50 horsepower.
Valve was originally designed to handle liquid nitrogen tetroxide and mononethyl hydrazine. It successfully survived leakage at temperature as low as minus 95.5 C. It seals tightly against cold fluids, even after thousands of opening-and-closing cycles.
Modified pressure-regulator valve developed for arc powered wind tunnels allows automatic, accurate, and easily adjustable transfer of excess airflow.
Special boiling and drying process removes approximately one half of extractable hydrocarbon tail present in peroxide cured elastomer of valve seals.
Development work on a device for the Space Shuttle that will prevent the transfer of viable microorganisms within water systems is described. The device serves as a check valve in that it prevents the transfer or cross-contamination of microorganisms from a nonpotable system into a potable water system when these systems are interconnected. In this regard, the function of the device is similar to that of the air gap found in conventional one gravity systems. The device is essentially a bed of resin material impregnated with iodine. Basic design data for a variety of flow and temperature conditions are presented, together with results of challenging the beds with suspensions of seven microorganisms including aerobes, anaerobes, and spore formers.
A residual iodine microbial check valve (RIMCV) assembly was developed and tested. The assembly is designed to be used in the space shuttle potable water system. The RIMCV is based on an anion exchange resin that is supersaturated with an iodine solution. This system causes a residual to be present in the effluent water which provides continuing bactericidal action. A flight prototype design was finalized and five units were manufactured and delivered.
The Microbial Check Valve (MCV) is a device developed for the Space Shuttle that prevents the transfer of viable microorganisms within water systems. The device is essentially a bed of resin material, impregnated with iodine, that kills microorganisms on contact. It prevents the cross-contamination of microorganisms from a nonpotable system into the potable water system when these systems are interconnected. In this regard, the function of the device is similar to that of the 'air gap' found in conventional one-gravity systems. Basic design data are presented including pressure drop, scaling factors, sizing criteria, and the results of challenging the device with suspensions of seven microorganisms including aerobes, anaerobes and spore formers.
An airflow valve and its electrohydraulic actuation servosystem are described. The servosystem uses a high-power, single-stage servovalve to obtain a dynamic response beyond that of systems designed with conventional two-stage servovalves. The electrohydraulic servosystem is analyzed and the limitations imposed on system performance by such nonlinearities as signal saturations and power limitations are discussed. Descriptions of the mechanical design concepts and developmental considerations are included. Dynamic data, in the form of sweep-frequency test results, are presented and comparison with analytical results obtained with an analog computer model is made.
A flight certified assembly identified as a Microbial Check Valve (MCV) was developed and tested. The MCV is a canister packed with an iodinated anionic exchange resin. The device is used to destroy organisms in a water stream as the water passes through the device. The device is equally effective for fluid flow in either direction and its primary method of organism removal is killing rather than filtering. The MCV was successfully developed for the space shuttle to: disinfect fuel cell water; and prevent back contamination of the stored potable water supply. One version of the device consists of a high residual iodinated resin bed that imparts approximately 2 ppm of iodine to the fuel cell water as it flows to the potable water tanks. A second version of the device consists of a low residual iodinated resin bed. One of these low residual beds is located at each use port in the potable water system for the dual purpose of removing some iodine from the potable water as it is dispensed and also to prevent back contamination of the potable supply.
The results of a re-evaluation of the propellant combustion data obtained using the dual valve approach for measuring velocity-coupling characteristics of solid propellants are presented. Data analysis and testing procedures are described. The velocity response is compared to pressure-coupled response data within the context of thermal wave response theory. This comparison shows important inconsistencies which cast doubt on inferring the velocity response from pressure-coupled response functions.
Valve cap seated on an O-ring lifts to relieve positive pressure. Is attached to vacuum system by screw-on housing. Caps are loosely tied to pipe with twine or thin wire to make recovery simple.
The Microbial Check Valve (MCV) is a flight qualified assembly that provides bacteriologically safe drinking water for the Space Shuttle. The 1-lb unit is basically a canister packed with an iodinated ion-exchange resin. The device is used to destroy organisms in a water stream as the water passes through it. It is equally effective for fluid flow in either direction and its primary method of disinfection is killing rather than filtering. The MCV was developed to disinfect the fuel cell water and to prevent back contamination of stored potable water on the Space Shuttle. This paper reports its potential for space applications beyond the basic Shuttle mission. Data are presented that indicate the MCV is suitable for use in advanced systems that NASA has under development for the reclamation of humidity condensate, wash water and human urine.
Hydraulic valve designed for controlling high-pressure fluid stream with low-pressure gas for fluid includes free-floating cylindrical control piston.