Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Development of a FELIX based readout system for ITk strip hybrid module demonstrator for ATLAS Phase-II Upgrade

The Large Hadron Collider (LHC) will undergo a major upgrade around 2024 with a roughly tenfold increase in luminosity. It results in corresponding increases in particle rates and radiation doses that the current ATLAS Inner Tracking Detector cannot cope with. Therefore the ATLAS experiment will build a new all-silicon tracking system called the ITk (Inner Tracker) that includes an inside pixel detector close to the beam line and a strip detector in outside layer. Meanwhile the ATLAS experiment will adopt the Front-End Link eXchange (FELIX) system as the interface between the data acquisition and front-end electronics for all sub-detectors in the Phase II Upgrade. In this contribution, we present a prototype of FELIX based readout system for the strip hybrid module. Its hardware, firmware and software GUI application will be discussed, as well as integration test results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Construction status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter plays an important role in providing excellent particle identification capabilities and a fast online trigger filter, while aiding the track reconstruction capabilities. Calorimeter requirements are to provide a large acceptance for 0~10 MeV electrons and reach: i) a time resolution better than 0.5 ns; ii) an energy resolution better than 10%; and iii) a position resolution of 1 cm. The calorimeter consists of two disks, each one made of 674 pure CsI crystals. Each crystal is readout by two large area 2×3 arrays of UV-extended SiPMs of 6×6 mm2 dimensions. A large scale prototype (Module-0) has been tested at an electron beam. We report here the tests done to finalize the calorimeter design, the results obtained with Module-0 and the status of production. At this time, the performance characteristics of 85% of the crystals and all of the SiPMs have been measured. The calorimeter engineering drawings have been completed and the large mechanical components are under fabrication. Analog and digital electronics have been prototyped and tested with irradiation dose. Their serial production is being organized. The calorimeter assembly phase is planned for mid-2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of radiation hardness of High-Voltage silicon vertical JFETs

In the future ATLAS Inner Tracker, each silicon strip module will be equipped with a switch able to separate the high voltage supply from the sensor in case the latter becomes faulty. The switch, placed in between the HV supply and the sensor, needs to sustain a high voltage in its OFF state, to offer a low resistance path for the sensor leakage current in the ON state, and be radiation hard up to 1.2 * 10 15 neq/cm 2 along with other requirements. While GaN JFETs have been selected as suitable rad-hard switch, a silicon vertical HV-JFET was developed by Brookhaven National Laboratory as an alternative option. Pre-irradiation results showed the functionality of the device and proved that the silicon HV-JFET satisfied the pre-irradiation requirements for the switch. To assess its suitability after irradiation, a few p-type HV-JFETs have been neutron irradiated at Jozef Stefan Institute (JSI, Ljubljana, Slovenia). Overall, this paper reports the static characterization of these irradiated devices and the TCAD numerical simulations used to get an insight of the physics governing the post-irradiation behaviour.

47 OTHER INSTRUMENTATION↗

Quality assurance test of silicon photomultipliers and electronic boards for STAR event plane detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver (RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. As a result, the QA test results are presented along with the discussions.

EPD↗

Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents

Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and physics analysis. This paper presents simulations and measurements of the leakage current in the ATLAS pixel detector and semiconductor tracker as a function of location in the detector and time, using data collected in Run 1 (2010-2012) and Run 2 (2015-2018) of the Large Hadron Collider. The extracted fluence shows a much stronger |z|-dependence in the innermost layers than is seen in simulation. Furthermore, the overall fluence on the second innermost layer is significantly higher than in simulation, with better agreement in layers at higher radii. These measurements are important for validating the simulation models and can be used in part to justify safety factors for future detector designs and interventions.

47 OTHER INSTRUMENTATION↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of BNL and HPK AC-LGAD sensors with a 120 GeV proton beam

We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. Here we studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows detailed studies of signal sharing characteristics. These measurements allow us to assess the differences in designs between different manufacturers, and optimize them based on experimental performance. We then study several reconstruction algorithms to optimize position and time resolutions that utilize the signal sharing properties of each sensor. We present a world's first demonstration of silicon sensors in a test beam that simultaneously achieve better than 6–10 μm position and 30 ps time resolution. This represents a substantial improvement to the spatial resolution than would be obtained with binary readout of sensors with similar pitch.

47 OTHER INSTRUMENTATION↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

Pre-production results from ATLAS ITk Strip Sensors Quality Assurance Testchip

The production of strip sensors within the framework of the ATLAS Inner Tracker (ITk) development is a process which requires continuous evaluation during the full production period (about 4 years). Such an evaluation is divided into two different parts: Quality Control (QC), which focuses on the final product (the actual sensors) and tries to identify possible defects once the fabrication is completed, and Quality Assurance (QA), which aims to prevent deviations in the manufacturing process and uses specifically-designed test structures. The initial sensor pre-production consists of 5% (1041 sensors) of the total number of sensors expected during production. As part of pre-production, the collaboration has measured key parameters from miniature strip sensors (minis), monitor diodes (MD8), and the ATLAS Testchip, before and after irradiation. In this contribution we focus on the analysis of the results of the MD8 and the Testchip. All parameters have been obtained from the test structures (MD8, bias resistors, interdigitated structures, field oxide capacitors, coupling capacitors, punch-through protection structures and cross-bridge resistors) measured at the different test sites (KEK/Tsukuba, Birmingham, Toronto, Ljubljana, Valencia, Carleton, Prague, CNM-Barcelona). The results are compared to predefined pre- and post-irradiation specifications for each tested parameter.

47 OTHER INSTRUMENTATION↗

Electrical performances of pre-production staves for the ATLAS ITk Strip Detector Upgrade

The ATLAS experiment is currently preparing for an upgrade of the inner tracking detector for the High-Luminosity LHC. The new tracker, ITk, employs an all-silicon detector with outer strip layers. The building block of the ITk strip barrel is the stave which consists of a low-mass support structure hosting the common electrical, optical and cooling services as well as 28 silicon modules. In this contribution, we outline the challenging aspects of the stave pre-production testing phase at Brookhaven National Laboratory. Here, the electrical characterization of these staves, hosting the final design of all ASICs, will be discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation tolerance studies of the HV-mux GaNFETs for the HL-LHC ATLAS ITk Strip detector

For the High-Luminosity upgrade of the LHC, the current ATLAS inner detector will be replaced with a new silicon charged-particle tracker, the ITk, which consists of the ITk Pixel and the ITk Strip subdetector. The high voltage multiplexing (HV-Mux) GaNFETs are radiation-tolerant transistors that permit switching off high voltage to malfunctioning sensors on the ITk Strip modules. To ensure the reliability of the GaNFETs in the high radiation environment expected at the HL-LHC, a sample of the production batch was exposed to gamma radiation. Finally, the GaNFETs were characterized pre-irradiation and post-irradiation, and monitored during irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning for precise hit position reconstruction in Resistive Silicon Detectors

RSDs are LGAD silicon sensors with 100% fill factor, based on the principle of AC-coupled resistive read-out. Signal sharing and internal charge multiplication are the RSD key features to achieve picosecond-level time resolution and micron-level spatial resolution, thus making these sensors promising candidates as 4D-trackers for future experiments. This paper describes the use of a neural network to reconstruct the hit position of ionizing particles, an approach that can boost the performance of the RSD with respect to analytical models. The neural network has been trained in the laboratory and then validated on test beam data. The device-under-test in this work is a 450 μm-pitch matrix from the FBK RSD2 production, which achieved a resolution of about 65 μm at the DESY Test Beam Facility, a 50% improvement compared to a simple analytical reconstruction method, and a factor two better than the resolution of a standard pixel sensor of equal pitch size with binary read-out. The test beam result is compatible with the laboratory ones obtained during the neural network training, confirming the ability of the machine learning model to provide accurate predictions even in environments very different from the training one. Prospects for future improvements are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Setups for eliminating static charge of the ATLAS18 strip sensors

Abstract Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration to beable to track charged particles produced at the High-Luminosity LHC, started in 2020 and is expected tocontinue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-psilicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced sensors are measured upon their delivery at several institutes participating in a complex Quality Control (QC) program. The QC tests performed on each individual sensor check the overall integrity and quality of the sensor.During the QC testing of ATLAS18 strip sensors, an increased number of sensors thatfailed the electrical tests was observed. In particular, IV measurements indicated an early breakdown,while large areas containing several tens or hundreds of neighbouring strips with low interstrip isolationwere identified by the Full strip tests, and leakage current instabilities were measured in a long-term leakage current stability setup. Moreover, a high surface electrostatic charge reaching a level of several hundreds of volts per inch was measured on a large number of sensors and on the plastic sheets, whichmechanically protect these sensors in their paper envelopes. Accumulated data indicates a clearcorrelation between observed electrical failures and the sensor charge-up.To mitigate the above-described issues, the QC testing sites significantly modified the sensor handlingprocedures and introduced sensor recovery techniques based on irradiation of the sensor surface with UVlight or application of intensive flows of ionized gas. In this presentation, we will describe the setupsimplemented by the QC testing sites to treat silicon strip sensors affected by static charge andevaluate the effectiveness of these setups in terms of improvement of the sensor performance.

Instruments & Instrumentation↗

AstroPix4 — a novel HV-CMOS sensor developed for space based experiments

For the proposed space based gamma-ray observatory All-sky Medium-Energy Gamma-ray Observatory eXplorer (AMEGO-X), a silicon tracker based on a novel High Voltage-CMOS (HV-CMOS) sensor called AstroPix, is currently being developed. Preliminary measurements with the first full reticle prototype AstroPix3 show that the power target of 1.5 mW/cm 2 can currently not be reached due to the digital consumption of 3.08 mW/cm 2 , while the analog power consumption of 1.04 mW/cm 2 and a break down voltage of over 350 V look promising. Based on these results, the design changes in AstroPix4, submitted in May 2023, are presented, containing changes to the time stamp generation and readout architecture. A digital power consumption below 0.25 mW/cm 2 is expected by removing the fast 200 MHz clock used to measure the time-over-threshold (ToT) and an LVDS receiver. A maximum resolution of 3.125 ns for time-of-arrival (ToA) and ToT is reached by adding per-pixel Flash-Time-to-Digital Converter (TDCs) controlled by a global delay-locked loop (DLL).

47 OTHER INSTRUMENTATION↗

Performance of the ATLAS forward proton Time-of-Flight detector in Run 2

We present performance studies of the Time-of-Flight (ToF) subdetector of the ATLAS Forward Proton (AFP) detector at the LHC. Efficiencies and resolutions are measured using high-statistics data samples collected at low and moderate pile-up in 2017, the first year when the detectors were installed on both sides of the interaction region. While low efficiencies are observed, of the order of a few percent, the resolutions of the two ToF detectors measured individually are 21 ps and 28 ps, yielding an expected resolution of the longitudinal position of the interaction, z vtx , in the central ATLAS detector of 5.3 ± 0.6 mm. This is in agreement with the observed width of the distribution of the difference between z vtx , measured independently by the central ATLAS tracker and by the ToF detector, of 6.0 ± 2.0 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to observe field-region oxide charge and inter-electrode isolation from CV-characteristics of n-on-p devices

Abstract N-on-psilicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditionalp-on-nsensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO 2 -passivatedn-on-psensors is the generation of an inversion layer under the Si/SiO 2 -interface by a positive interface-oxide-charge (N ox ) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolnts (p-stp,p-spray) between n + -electrodes. Focusing on the guard-ring regions ofn-on-psensors where no isolation implants are applied between the electrodes, a capacitance-voltage (CV) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage (V th,iso ) in theCV-characteristics of a biased n + -electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measuredV th,iso was found to contain information on the field-regionN ox and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiatedn-on-psensors, the results indicate that position sensitiven-on-psensors without isolation implants may be feasible in future HEP experiments.

Instruments & Instrumentation↗

An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules

At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about -35°C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times — this study is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗