Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Analysis of scintillation light dependence on Liquid Argon purity in the ICARUS detector

Previous studies have investigated the correlation between impurities concentration in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield.These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N$_{2}$), can influence LAr scintillation properties without necessarily affecting electron lifetime.Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetime in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS detector consists of two cryostats that have shown different behaviors in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats and presents the methodology used to extract scintillation timing characteristics and their correlation with LAr purity.

Saia, C. [Catania Astrophys. Observ.] (ORCID:00090↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Design of flexible proton beam imaging energy spectrometers (PROBIES)

A simple repeating step-filtered structure has been designed and deployed for the detection of MeV-energy proton beams produced from high-intensity short-pulse laser-driven experiments. Due to the diagnostic's ability to recover energy-resolved images of proton beams, it is called the proton beam imager and energy spectrometer (or PROBIES). The flexible design has two useful applications. First, it can be fielded in a configuration with a scintillator and imaging setup in order to collect proton beam information in high-repetition rate experiments. Here we show a configuration that collects the equivalent of a nine-film radiochromic film (RCF) stack, and a technique for using a neural network (NN) to rapidly analyze the images on millisecond time-scales. Second, when using RCF stacks as the detector, the energy resolution capability is greatly increased compared to traditional RCF stacks, while simultaneously reducing the total number of films required to make each measurement. We demonstrate a configuration that provides up to 90 spatially- and energy-resolved datapoints using just ten films. Both designs presented here can be easily customized for anticipated experimental outputs and manufactured at low cost. Such designs allow for rapid prototyping using modern high-accuracy 3D printers or on-demand computer numerical control machining to reduce the reliance on time-consuming film media, analysis, or bulky electro-magnetically dispersing spectrometers. The analysis of data is discussed and a methodology for constructing a NN that is capable of rapidly analyzing data on-the-fly with greater than 95% accuracy is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and implementation of the new scintillation light detection system of ICARUS T600

ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab (U.S.A.), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementation of the new scintillation light detection system of ICARUS T600 is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlocal subpicosecond delay metrology using spectral quantum interference

Precise knowledge of position and timing information is critical to support elementary protocols such as entanglement swapping on quantum networks. While approaches have been devised to use quantum light for such metrology, they largely rely on time-of-flight (ToF) measurements with single-photon detectors and, therefore, are limited to picosecond-scale resolution owing to detector jitter. In this work, we demonstrate an approach to distributed sensing that leverages phase modulation to map changes in the spectral phase to coincidence probability, thereby overcoming the limits imposed by single-photon detection. By extracting information about the joint biphoton phase, we measure a generalized delay—the difference in signal–idler arrival, relative to local radio frequency (RF) phase modulation. For nonlocal ranging measurements, we achieve (2$σ$) precision of ±0.04 ps and for measurements of the relative RF phase, (2$σ$) precision of ±0.7°. We complement this fine timing information with ToF data from single-photon time-tagging to demonstrate absolute measurement of time delay. By relying on off-the-shelf telecommunications equipment and standard quantum resources, this approach has the potential to reduce overhead in practical quantum networks.

42 ENGINEERING↗

The CeBrA demonstrator for particle-γ coincidence experiments at the FSU Super-Enge Split-Pole Spectrograph

We report on a highly selective experimental setup for particle-γ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University (FSU) using fast CeBr scintillators for γ-ray detection. Specifically, we report on the results of characterization tests for the first five CeBr 3 scintillation detectors of the CeBr 3 Array (CeBrA) with respect to energy resolution and timing characteristics. We also present results from the first particle-γ coincidence experiments successfully performed with the CeBrA demonstrator and the FSU SE-SPS. We show that with the new setup, γ-decay branching ratios and particle-γ angular correlations can be measured very selectively using narrow excitation energy gates, which are possible thanks to the excellent particle energy resolution of the SE-SPS. In addition, we highlight that nuclear level lifetimes in the nanoseconds regime can be determined by measuring the time difference between particle detection with the SE-SPS focal-plane scintillator and γ-ray detection with the fast CeBrA detectors. As a result, selective excitation energy gates with the SE-SPS exclude any feeding contributions to these lifetimes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Persistent, “Mysterious” Seismoacoustic Signals Reported in Oklahoma State during 2019

Here, we report on the source of seismoacoustic pulses that were observed across the state of Oklahoma (OK) during summer of 2019, and the subject of national media coverage and speculation. Seismic network data collected across four U.S. states and interviews with witnesses to the pulse’s effect on residential structures demonstrate that they were triggered by routine ammunition disposal operations conducted by McAlester Army Ammunition Plant (McAAP). During these operations, conventional explosives destroy obsolete munitions stored in pits through a controlled sequence of electronically timed shots that occur over tens of minutes. Despite noise-abatement efforts that reduce coupling of acoustic energy with air, some lower frequency, subaudible (infrasonic) sound radiates from these shots as discrete pulses. We use nine months of blast log documents, seismic network records, analyst picks, and physical modeling to demonstrate that seismic stations as far as 640 km from McAAP sample these pulses, which record seasonal patterns in stratospheric and tropospheric winds, as well as the dynamic formation of waveguides and shadow zones. Digital short-term average to long-term average detectors that we augment with dynamic thresholds and time-binning operations identify these pulses with a fair probability, when compared with visual observations. Our analyses thereby provide estimates of observation rates for both partial and full sequences of these pulses, as well as single shots. We suggest that disposal operations can exploit existing, composite seismic networks to predict where residents are likely to witness blasting. Crucially, our data also show that dense seismic networks can record multiscale atmospheric processes in the absence of infrasound arrays.

58 GEOSCIENCES↗

Optimization Simulations for a Gamma-Ray Calibration Standard for a Cyclic Neutron Activation Analysis Pneumatic System at the Penn State Breazeale Reactor

For new experimental setups, the initial testing and calibrations can be expensive and time consuming without prior optimization. However, these issues can be mitigated using realistic modeling and simulation studies of the proposed system a priori. Specifically, an experiment can be performed virtually using realistic simulations and the expected results evaluated to inform adjustments of the experimental setup to achieve optimum results. At the Penn State Breazeale Reactor, a new pneumatic transfer system has been developed for the detection and characterization of short-lived fission fragments to enhance and complement existing nuclear data. The system accomplishes this task by transporting samples cyclically between an assortment of gamma-ray/neutron detectors and the reactor-core vicinity with sub-second transit times. The measured neutron flux paired with simulations of detector response using Geant4 and a custom module for estimating cascade summing effects and corrections were used to select sample-material masses for system characterization. With the optimized sample masses, an experimental counting plan for characterizing the repeatability of the newly developed pneumatic system was developed. Finally, the predictions made with these simulations allowed for optimization of the irradiation sample characteristics and gamma-ray detection system.

cyclic neutron activation, gamma-ray spectroscopy↗

Joint Actinide Shock Physics Experimental Research (JASPER): System Design Requirements: Trigger Unit

One of the key systems required for the Joint Actinide Shock Physics Experimental Research (JASPER) facility is the timely triggering of the Prompt System (PS). The Trigger Unit (TU) is the critical component that determines when the PS is to be triggered. There are two redundant TUs within the JASPER system, and each TU creates three redundant triggers for the PS. In this fashion, the Prompt Trigger System (PTS) can suffer the loss of one sensor, as well as the loss of one TU, and still function correctly. The TU is designed to receive signals from five separate sensors along the flight of the projectile on its way to the target. The TU uses three pairs of these detectors to create a trigger pulse at the appropriate time, based on the actual velocity of the projectile as it passes between the two sensors.

42 ENGINEERING↗

A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility

The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV, covering over 6 decades in mass: 1-100 eV for dark photons and axion-like particles, 1-100 MeV for dark-photon-coupled light dark matter, and 0.05-5 GeV for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion. The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploiting the PRISM Feature and Purity Monitors of the SBND Neutrino Detector

The Short-Baseline Neutrino (SBN) program at Fermilab will pursue neutrino properties searches, exploiting three Liquid Argon Time Projection Chamber (LArTPC) experiments to investigate neutrino oscillations with neutrinos from the Booster Neutrino Beam (BNB). SBND will be the near detector in the program, measuring the un-oscillated flux. It is anticipated to begin operating in 2023. Thanks to its peculiar proximity to the neutrino source of about 110 meters, SBND will collect extremely high statistics data of the flux in the GeV energy range, providing unprecedented precision measurements. SBND particular setting also allows to take measurements at different distances from BNB’s center maintaining statistics high enough at each range. LArTPC and the cold electronics technologies, as well as the argon-neutrino interaction studies, will play a key role in future neutrino physics. In this prospect, this work was focused on two SBND features: SBND PRISM tool, with the aim of investigating neutrino flux at different distances from the beam axis, and Purity Monitors, which provide a clever measurement of argon purity in the detector, whose value is fundamental in neutrino-argon interaction.

43 PARTICLE ACCELERATORS↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

Optimization of the light detection system of the ICARUS detector

The Short Baseline Neutrino (SBN) Program at Fermilab is designed to investigate short-baseline neutrino oscillations and test the hypothesis of sterile neutrinos, motivated by several experimental anomalies observed over the past decades. Within this program, the ICARUS experiment plays a key role. It employs the world’s largest Liquid Argon Time Projection Chamber (LArTPC) and serves as the farthest and most sensitive SBN detector for studying muon and electron neutrino oscillations. A crucial subsystem of the ICARUS detector is the Light Detection System (LDS), which captures the prompt scintillation light produced by neutrino interactions in the 600-ton active liquid Argon volume. This system provides precise timing information that is essential for event reconstruction, the trigger system, and cosmic background rejection. The LDS is composed of 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), operating under cryogenic conditions ($\sim 87 \ K$) inside the detector’s cryostats. During the detector’s operation at FNAL, a degradation in PMT gain has been observed, attributed to aging under low-temperature conditions. In collaboration with ICARUS teams from INFN Pavia and Catania, I developed an experimental setup to study the temperature-dependent behavior of the PMTs, performing gain measurements both at room temperature and down to $-70°C$ using a climatic chamber at INFN Catania. The results indicate that while the PMTs maintain stable gain at room temperature, a significant and permanent gain reduction occurs at low temperatures. Although $-70°C$ is still warmer than liquid Argon temperatures, the findings clearly demonstrate a gain-dependent performance degradation. The thesis also discusses mitigation strategies implemented in the ICARUS detector to address this issue and presents a simplified model to describe and simulate the observed behavior.

Saia, Clara [Catania U.] (ORCID:0009000464102417)↗

Scaler Rates from the Pierre Auger Observatory: A New Proxy of Solar Activity

The modulation of low-energy galactic cosmic rays reflects interplanetary magnetic field variations and can provide useful information on solar activity. An array of ground-surface detectors can reveal the secondary particles, which originate from the interaction of cosmic rays with the atmosphere. In this work, we present an investigation of the low-threshold rate (scaler) time series recorded in 16 yr of operation by the Pierre Auger Observatory surface detectors in Malargüe, Argentina. Through an advanced spectral analysis, we detected highly statistically significant variations in the time series with periods ranging from the decadal to the daily scale. We investigate their origin, revealing a direct connection with solar variability. Thanks to their intrinsic very low noise level, the Auger scalers allow a thorough and detailed investigation of the galactic cosmic-ray flux variations in the heliosphere at different timescales and can, therefore, be considered a new proxy of solar variability.

79 ASTRONOMY AND ASTROPHYSICS↗

A cryogenic muon tagging system based on kinetic inductance detectors for superconducting quantum processors

Ionizing radiation has emerged as a potential limiting factor for superconducting quantum processors, inducing quasiparticle bursts and correlated errors that challenge fault-tolerant operation. Atmospheric muons are particularly problematic due to their high energy and penetration power, making passive shielding ineffective. Therefore, monitoring the real-time muon flux is crucial to guide the development of alternative error-correction or mitigation strategies. We present the design, simulation, and first operation of a cryogenic muon-tagging system based on kinetic inductance detectors (KIDs), developed as a stand-alone cryogenic particle-tagging module for superconducting quantum processors. The system consists of two KIDs arranged in a vertical stack and operated at ∼20 mK. Monte Carlo simulations based on Geant4 guided the prototype design and provided reference expectations for muon-tagging efficiency and accidental coincidences due to ambient γ-rays. We observed a muon-induced coincidence rate among the top and bottom detectors of (192 ± 9) $\times\,10^{-3}$ events s$^{−1}$, in excellent agreement with the Monte Carlo prediction. The prototype achieves a muon-tagging efficiency of about 90% with negligible dead time. These results demonstrate the feasibility of operating a muon-tagging system at millikelvin temperatures and represent a key step toward the integration of cryogenic veto systems with multi-qubit chips to mitigate muon-induced errors.

Mariani, Ambra [INFN, Rome] (ORCID:000000028184857↗

System, algorithm, and method using short pulse interrogation with neutrons to detect and identify matter

A system, method, and algorithm for detecting and identifying special nuclear material (SNM) (including fissionable material), explosives, or drugs is disclosed. This material detection system relies on active interrogation of material using a short, intense neutron pulse, and characterization of the resulting prompt gamma response in two short time windows, the first concurrent with and the second immediately following the end of the neutron pulse, optionally subject to a total transit delay time of the neutrons from the neutron source to the target and from the target to the gamma detector. A high data rate analysis system implements data stream analysis and statistical correlations of the two short time window gamma responses to rapidly detect or identify SNM, explosives, or drugs. The duration of the neutron pulse is so short that minimal dose results. Various shields help to minimize the background signal falling on the gamma detector to improve sensitivity.

Derzon, Mark S.↗