Experimental testing of particle attrition in CSP systems at high temperature

An alternate and sustainable form of energy is CSP systems, which capture and store the sun’s energy in the form of heat. Increasing the operational temperature of CSP systems will increase the efficiency of electricity production while operating at temperatures exceeding 700 degrees Celsius also creates novel operational problems. One approach for high-temperature CSP systems is to utilize solid particles as the primary heat transfer medium. As particles flow through this system, the movement of particles creates erosion in the forms of impact, abrasion, and attrition erosion. In the real world, while all three forms of erosion will occur simultaneously, it is imperative to understand the individual effect of each erosion over the lifetime of the powerplant. Besides material erosion and long-term durability concerns, thermal cycling of the particles could also introduce changes in particle thermal performance due to alterations in particle morphology. Current research on the issue of erosion has been limited to industrial applications and does not necessarily coincide with the operating conditions in CSP systems. We focus on attrition erosion resulting from particle-to-wall and particle-to-particle interactions. Research has shown that besides material hardness affecting how fast particles break down, attrition erosion increased as the size of the particles increased due to a higher chance of collision between the particles. Particle attrition is relevant to the CSP community as it may result in material loss, change the system's thermal performance, and generation of fines which could pose an environmental hazard. In this work, we focus on developing a test set up that can isolate and measure particle attrition when subjected to conditions relevant to Gen3 CSP systems.

14 SOLAR ENERGY↗

HE Production Update at JLab - Introducing an Enhanced Nitrogen Purge for Clean String Assembly

A major limitation to cryomodule performance is field emission caused by particulates within the superconducting cavities. To reduce contamination of the inner surfaces during assembly in a cleanroom, the whole string can be connected to a purge system, which maintains a constant overpressure of dry, clean nitrogen gas. Following successes of similar systems at XFEL and Fermilab, Jefferson Lab followed this example for the production of LCLS-II HE cryomodules. Implementing this system required new procedures, infrastructure, and hardware, as well as significant testing of the system before production began. This paper will summarize the implemented controls and procedures, including lessons learned from Fermilab, as well as the results of mock-up tests. Based on the latter, the system was used to assemble the first article string in April 2022, and was also used during a rework required due to issues with cold FPC ceramics two months later. The benefits of using a purge system with regards to procedure, time savings, and added flexibility for potential rework have already proven to provide a significant improvement for the production of LCLS-II-HE cryomodules at Jefferson Lab.

Owen, P. D.↗

A Heterogeneous System for Eagle Detection, Deterrent, and Wildlife Collision Detection for Wind Turbines (Final Technical Report)

This report summarizes the design, implementation, and test of an integrated system for automated detection and deterrence of eagles, with included wind turbine blade strike detection and imaging functionality. A machine learning approach was used in conjunction with a 360° camera system for automated detection and classification of golden eagles. This was developed using footage obtained from trained golden eagles and other raptors, in collaboration with wildlife biologists and professional bird handlers. Oregon State University developed a visual deterrent system, which uses inflatable anthropomorphic sculptures with random, kinetic motion to deter eagles, and conducted limited field testing on live eagles; the deterrent can be triggered by the visual detection of eagles using the vision system. Finally, a multi-sensor module was developed that is mounted at the turbine blade root. This module measures vibration and other motions to detect blade strikes, and an integrated on-blade camera captures an image of any impacting objects. Long-term, this blade strike detection system is intended to support an automatic monitoring and certification system for the eagle detection and deterent system. Independent field testing of each system component is described. Testing of the integrated system on an operational wind turbine was conducted across three separate field tests. This includes multi-day fields tests on a General Electric 1.5MW wind turbine at the National Renewable Energy Laboratory (NREL) National Wind Technology Center (NWTC) in Boulder, CO in October 2018 and July 2019; installation procedures, test procedures, and a summary of collected data are presented. A third multi-day on-turbine field test is also presented, which was performed using a General Electric 1.5MW wind turbine at the North American Wind Research and Training Center (NAWRTC) at Mesalands Community College, Tucumcari, NM in April 2019. Across these field tests, the vision system was demonstrated using unmanned aerial vehicles (UAV), and the eagle classification algorithm was not tested; the visual deterrent system was demonstrated, including automatic, remote deployment following surrogate visual detections; and, multi-sensor on-blade data was recorded across multiple wind turbine operational conditions and through more than 100 surrogate blade strikes using soft projectiles, including the successful demonstration of automatic image capture of striking objects. This data set was also used for offline development and validation of enhanced collision detection algorithms. As summarized in this report, the development and field validation of an integrated detection, deterrent, and blade collision detection system represents a critical proof of concept for future technology development of related detection and deterrent technologies, where both deterrent as well as collision detection recording devices are needed for future siting, monitoring, and operation of wind turbine installations, both onshore and offshore.

17 WIND ENERGY↗

Testing convolutional neural network based deep learning systems: a statistical metamorphic approach

Machine learning technology spans many areas and today plays a significant role in addressing a wide range of problems in critical domains,i.e., healthcare, autonomous driving, finance, manufacturing, cybersecurity,etc. Metamorphic testing (MT) is considered a simple but very powerful approach in testing such computationally complex systems for which either an oracle is not available or is available but difficult to apply. Conventional metamorphic testing techniques have certain limitations in verifying deep learning-based models (i.e., convolutional neural networks (CNNs)) that have a stochastic nature (because of randomly initializing the network weights) in their training. In this article, we attempt to address this problem by using a statistical metamorphic testing (SMT) technique that does not require software testers to worry about fixing the random seeds (to get deterministic results) to verify the metamorphic relations (MRs). We propose seven MRs combined with different statistical methods to statistically verify whether the program under test adheres to the relation(s) specified in the MR(s). We further use mutation testing techniques to show the usefulness of the proposed approach in the healthcare space and test two CNN-based deep learning models (used for pneumonia detection among patients). The empirical results show that our proposed approach uncovers 85.71% of the implementation faults in the classifiers under test (CUT). Furthermore, we also propose an MRs minimization algorithm for the CUT, thus saving computational costs and organizational testing resources.

Computer Science↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

A Bayesian Framework for Milling Stability Prediction and Reverse Parameter Identification

This paper describes a physics-guided Bayesian framework for identifying the milling stability boundary and system parameters through iterative testing. Prior uncertainties for the parameters are identified through physical simulation and literature reviews, without physical testing of the actual milling system. Those uncertainties are then propagated to the stability map using a physics-based stability model, which is used to suggest a test point. The uncertainties are updated based on the new information acquired from the cutting test to form a new probability distribution, called the posterior. Finally, the posterior are compared to measured values for the stability boundary and system parameters to evaluate the approach. Based on experimental observations, the advantages and disadvantages of using a physics-guided model are discussed.

Cornelius, Aaron↗

Post Access Report: Initial testing of wave energy powered UV-C LED anti-biofouling system

In the experiment entitled “Initial Testing of Wave Energy Powered UV-C LED Anti-Biofouling System,” a UV-C LED was used to treat platinum-coated titanium coupons emulating CTD electrode material. An additional control set of coupons were exposed to seawater without the LED treatment. The experimental setup was deployed in seawater tanks at PNNL-Sequim’s Marine and Coastal Research Laboratory (MCRL) for the duration of six months. Tank seawater temperature data were collected for the duration of the experimental campaign. At two-month intervals triplicate sets of coupons were removed from both treatment and control test chambers and weighed to characterize biomass accumulation. After weighing, the coupons were photographed in initial condition, with a stain applied to highlight biofouling growth, and after rinsing off excess stain. These photographs were analyzed using PNNL’s Biofouling Growth Index (BGI) software and with a calculation of percentage dark pixels after conversion to grayscale. Additionally, at the final 6-month datapoint triplicate sets of control and test coupons were sent to PNNL-Richland’s Environmental Molecular Sciences Laboratory (EMSL) for scanning electron microscopy. All data organization and collection methods are described in further detail in the document “TEAMER_3newable_Data_Guide.pdf.” Biomass accumulation increased over time on both sets of coupons, and percent area biofouled demonstrated a similar trend. Analysis of the collected data resulted in the findings that treatment method has an impact on biofouling growth, though to a much less significant extent than time does. Additionally, qualitative findings included the presence of advanced life forms such as worms in the control test chamber, but not in the treated test chamber.

16 TIDAL AND WAVE POWER↗

Noble Metals Testing on the DM1200 Pilot Melter System with AZ-101 HLW Simulants, VSL-03R3740-2, Rev. 0

This report documents the results obtained with respect to the behavior of noble metals in tests on the DM1200 HLW Pilot Melter during processing of simulated HLW AZ-101 feed. The principal objective of these tests was to collect data to determine the extent of retention of noble metals in the melter since that is an important uncertainty in determining the expected life of the WTP HLW melter. The present results constitute one part of an integrated testing strategy that has been developed to address this risk.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HYBRID Modeling of DETAIL Experimental Facility

Idaho National Laboratory continues to be at the forefront of advanced reactor systems and integrated energy systems research. Through the Thermal Energy Distribution System (TEDS) and Microreactor Agile Non-nuclear Test Bed (MAGNET) experiments in the Dynamic Energy Transport and Innovation Laboratory (DETAIL) within the Engineering Systems Laboratory, a mix of digital and physical testing systems can explore the operation of thermally and electrically integrated systems. Modeling of these systems has been done using the HYBRID modeling repository of the Integrated Energy Systems program. DETAIL also contains high temperature steam electrolysis (HTSE) units to produce hydrogen and generate the load imposed on MAGNET and TEDS. The dynamic modeling capabilities within the IES program describe the DETAIL components as-built and can be used to evaluate controls, process flows, and overall system conditions.

08 HYDROGEN↗

A Parameterization Study of Sew-EZ Materials: Types #6 and #8

Two material types identified by Sew-EZ were tested in various configurations, and under various conditions, by Sandia National Laboratories (SNL). The primary focus of this study was to assess the filtration performance of these two materials and identify if they perform similarly to certified N95 respirators. Testing was conducted on two systems which use distinctly different techniques to characterize the aerosol penetration characteristics of materials: a) R&D Filtration System: A large-scale R&D filtration system was used with testing parameters that mimicked NIOSH guidelines, where possible. Efficiency data as a function of particle size was attained using NaC1 as the test aerosol and a Scanning Mobility Particle Sizer (SMPS) for measurements. A more detailed system description can be found in Omana et al. 2020. b) Automated Tester: A commercial, automated filter tester (100Xs, Air Techniques International) was used to provide penetration/efficiency data for Sew EZ materials. The 100Xs aerosolizes a polydisperse NaC1 aerosol with a consistent concentration and size profile. The 100Xs manual (Air Techniques International 2018) states, "The aerosol particle size and distribution are designed to meet all requirements as defined in the relevant sections of NIOSH 42 CFR, Part 84 (pg. 32)."

36 MATERIALS SCIENCE↗

Testing of a Whole Home Energy Management System (Cooperative Research and Development Final Report)

NREL and B&B Technology Solutions Inc. will perform verification testing to demonstrate the effectiveness of our whole home energy management system. This energy management system will allow the electrification of various styles of homes reducing the emissions of CO2 by replacing existing fossil fuel-based home systems. CRADA benefit to DOE, Participant, and US Taxpayer: assists laboratory in achieving programmatic scope, and/or uses the laboratory's core competencies, and/or enhances U.S. competitiveness by utilizing DOE developed intellectual property and/or capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experiences Readying Applications for Exascale

The advent of Exascale computing invites an assessment of existing best practices for developing application readiness on the world's largest supercomputers. This work details observations from the last four years in preparing scientific applications to run on the Oak Ridge Leadership Computing Facility's (OLCF) Frontier system. This paper addresses a range of topics in software including programmability, tuning, and portability considerations that are key to moving applications from existing systems to future installations. A set of representative workloads provides case studies for general system and software testing. We evaluate the use of early access systems for development across several generations of hardware. Finally, we discuss how best practices were identified and disseminated to the community through a wide range of activities including user-guides and trainings. We conclude with recommendations for ensuring application readiness on future leadership computing systems.

exascale↗

Corrosion Testing of Refractory inContact with Molten Glasses Designed for Waste Vitrification - VSL Touchpoint Matrix Glasses

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF). The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests. Refractory corrosion is generally reported as physical material loss, measured in units of distance (e.g., inch) or as physical material loss rate, measured in units of distance per time (e.g., inch/day). In post-operational melters, the refractory corrosion is measured directly, sometimes reported as corrosion depth. Crucible tests are used in the laboratory to accelerate the refractory corrosion to facilitate a meaningful measurement in a commensurate amount of time. Crucible tests are particularly useful in understanding refractory corrosion across a large glass composition space, where operational testing would be prohibitive. Some of the critical parameters that are known to influence refractory corrosion by molten glass in a crucible test are temperature, system redox, molten salt phases, glass chemistry, and test duration. The majority of data collected for Monofrax® K-3 (hereafter referred to as K-3) corrosion is from crucible tests, but a small amount comes directly from scaled and production melters. Crucible test data has been collected under varying conditions, whereas data collected from operational melters is relatively fewer and represents conditions specific to the melter campaign. The result is that the published data can be grouped and analyzed in multiple ways, not all of which are readily comparable. The Standard Test Method for Isothermal Corrosion Resistance of Refractories to Molten Glass (ASTM C621) outlines the general guidelines used across industry. That method describes a sealed, static test in which the surface area of the refractory coupon and the volume of glass are fixed. A significant portion of the crucible data pertaining to nuclear waste glasses has been collected in a modified configuration; the most notable differences being the surface area of the refractory coupon to volume of the glass and use of a method for bubbling the melt. To our knowledge, the influence of those parameters on the refractory corrosion has not been quantified. In this work, it was determined that static tests and bubbled tests would be performed. Savannah River National Laboratory (SRNL) was tasked with setting up and performing static testing while PNNL was tasked with setting up and performing bubbled testing. Initial activities were performed to establish laboratory methods that reproduce data comparable to existing data sets of K-3 refractory corrosion by low activity waste (LAW) and high-level waste (HLW) glass compositions. Later activities were focused on refining the test parameters to establish a standard test practice to be used between Laboratories and collecting additional data to be used in the enhanced waste glass model development. This document serves primarily to convey the refractory loss measurement results from corrosion testing of K-3 refractory with waste glass compositions developed for use in the WTP melters. The data will be used in the enhanced property/composition models being developed for waste glass vitrification and melter operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influencing Activity of Bats by Dimly Lighting Wind Turbine Surfaces with Ultraviolet Light

Wind energy producers need deployable devices for wind turbines that prevent bat fatalities. Based on the speculation that bats approach turbines after visually mistaking them for trees, we tested a potential light-based deterrence method. It is likely that the affected bats see ultraviolet (UV) light at low intensities. Here, we present the results of a multi-month experiment to cast dim, flickering UV light across wind turbine surfaces at night. Our objectives were to refine and test a practical system for dimly UV-illuminating turbines while testing whether the experimental UV treatment influenced the activity of bats, birds, and insects. We mounted upward-facing UV light arrays on turbines and used thermal-imaging cameras to quantify the presence and activity of night-flying animals. The results demonstrated that the turbines can be lit to the highest reaches of the blades with “invisible” UV light, and the animal responses to such experimental treatment can be concurrently monitored. The UV treatment did not significantly change nighttime bat, insect, or bird activity at the wind turbine. Our findings show how observing flying animals with thermal cameras at night can help test emerging technologies intended to variably affect their behaviors around wind turbines.

17 WIND ENERGY↗

Experiences readying applications for Exascale

The advent of Exascale computing invites an assessment of existing best practices for developing application readiness on the world's largest supercomputers. This work details observations from the last four years in preparing scientific applications to run on the Oak Ridge Leadership Computing Facility's (OLCF) Frontier system. This paper addresses a range of topics in software including programmability, tuning, and portability considerations that are key to moving applications from existing systems to future installations. A set of representative workloads provides case studies for general system and software testing. We evaluate the use of early access systems for development across several generations of hardware. Finally, we discuss how best practices were identified and disseminated to the community through a wide range of activities including user-guides and trainings. We conclude with recommendations for ensuring application readiness on future leadership computing systems.

Gottiparthi, Kalyan↗

Secondary Frequency Regulation from Variable Generation through Uncertainty Decomposition: An Economic and Reliability Perspective

The rapid integration of variable generation (VG), such as photovoltaics (PV), necessitates an increase in the secondary frequency regulation (SFR) to handle the system intra-dispatch interval imbalance because of VG's variation. Although PV has the control capability to provide SFR, the main challenge is in guaranteeing the delivery of PV's energy and SFRs capacities in the automatic generation control (AGC) within each dispatch interval considering its uncertainty. This paper proposes a deliverable VG SFR provision model with endogenous VG's power uncertainty decomposition. First, the uncertainty of VG is decomposed using distributionally robust chance constraints through which the deliverable SFR provision is guaranteed. Next, the intra-interval frequency response of PV's SFR is validated with a user defined AGC model including the PV power plant. Finally, the economic benefits and the reliability improvements such as the frequency deviation reduction with PV providing SFRcan be integrated and evaluated. The proposed model is tested in a modified 18-bus system and in the Western Electricity Coordinating Council test system. Results demonstrate that with the deliverable SFR from PV, the system cost and the frequency reliability can be improved simultaneously. PV's SFR performance can be guaranteed with the proposed model.

14 SOLAR ENERGY↗

Design of a Meso-Scale Test of a Fracture Thermal Energy Storage (FTES) System

This paper will present the characterization, scaling, and design of an intermediate-scale field test of a fracture thermal energy storage system (FTES). Seasonal storage of thermal energy has the potential to both significantly reduce the total energy requirements for heating and cooling of buildings, but also allow for the flexibility to store thermal energy from intermittent sources. With approximately half of global energy consumption currently being used for heating and cooling, this represents an important path to reducing greenhouse gas (GHG) emissions. The concept of FTES is to drill two or more wells into a low permeability formation, generally at a depth of less than a few hundred meters, and then generate hydraulic fractures to create flow paths for water to circulate between the wells. Hot or cold thermal energy can then be stored in the surrounding rock mass by circulating hot or cold water through the fractures, which will heat or cool the rock mass. To recover the stored energy, ambient temperature water can be then circulated through the fractures, which will then be heated or cooled by the rock mass. Fractures inherently have a very large ratio of surface area to volume. This allows for very high heat fluxes to and from the rock mass to be achieved despite the relatively low thermal conductivity of most geologic formations. Because large fractures can be made with low-cost equipment and with only inexpensive and environmentally safe materials such as water and sand, the cost to construct even large FTES systems is expected to be quite low. This paper will present what the performance requirements, size, and operating conditions of a full-scale system to operate a commercial building. The paper will describe how these full-scale system characteristics will be used as a design basis for an intermediate-scale FTES test to be conducted at the Sanford Underground Research Facility (SURF) in Lead, SD.

Burghardt, Jeffrey A.↗