Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Characterization of actinide abundances and isotopic compositions by HR-ICP-MS. Part 2: Results from actinide doping studies

Previously, we presented actinide isotopic and elemental data from fallout melt glass that was measured using high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Direct comparison between these measurements and ‘gold standard’ data obtained by multi-collector ICP-MS showed broad overlap, indicating that HR-ICP-MS is a potentially valuable technique for producing actinide elemental and isotopic data on a relatively rapid timescale. To test the usefulness of this technique further, we doped varying amounts of uranium certified reference materials (CRMs) into a rhyolitic rock standard to establish the effects of uranium concentration and isotopic composition on the accuracy of uranium isotopic analyses by HR-ICP-MS. This also enabled us to quantify peak tailing effects from 238 U on the measurement of 239 Pu and 237 Np, which in turn allows us to constrain correction factors based on measured 237 Np/ 238 U and 239 Pu/ 238 U ratios. A second doping study involved the addition of a mixed actinide standard into three samples with different matrix compositions (termed soil, city, and seawater) to assess whether sample chemistry affects the accuracy and precision of these analyses. Results suggest that this is not the case. Systematic offsets were not observed in elemental or isotopic data derived from the three matrix samples. Results indicate that useful actinide isotopic data can be obtained from whole rock solutions by HR-ICP-MS. Our findings also have implications for solid sampling techniques such as laser ablation ICP-MS, which do not require sample dissolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

In-Pixel Readout IC with compact in-pixel ADC for Pixel detectors at HL LHC

The prototype Smart Pixel concept test chip (SP28), designed in a CMOS 28 nm bulk process, is a proof of concept readout integrated circuit (ROIC) designed for a future Phase III High Luminosity upgrade of the Large Hadron Collider. It employs a synchronous analog to digital converter (ADC) for the front-end design, with signal processing and data conversion within a single bunch crossing of 25 ns. It is therefore capable of accurately detecting hits occurring in consecutive bunch crossings, without off-time registration of events and pileup insensitivity, making it particularly suitable for the inner most layers of the vertex detector. The ROIC consists of a matrix of 32 × 16 pixels, each 25 × 25 µm 2 in size. Each pixel contains a charge sensitive preamplifer with leakage current compensation, three auto-zero comparators for a 2-bit fash-type ADC. The total power consumption is approximately 5 µW per pixel. The measured noise at the output of all the hit comparators across the ROIC is < 90 e- with threshold dispersion < 45 e-RMS, which allows an in-time threshold setting of ≈ 475 e-.

Parpillon, Benjamin↗

Glass-bonded ceramic waste forms for immobilization of radioiodine from caustic scrubber wastes

Glass-bonded sodalite composite waste forms have been developed for the immobilization of liquid radioactive wastes resulting from off-gas treatment during aqueous reprocessing of used nuclear fuel, with a particular focus on 129I. The proposed composite waste form is comprised of aluminosilicate ceramic phases containing volatile radionuclides bonded with a glassy matrix. In this work, a suite of ten candidate low-temperature glass binders (ZnO-Bi2O3-based glasses and a Na2O-B2O3-SiO2 glass) were examined. Six glasses were mixed with caustic scrubber waste simulant previously converted into a sodalite-rich material (to provide glass fractions of 10 and 20 wt.%), uniaxially pressed into pellets, and sintered at 350 °C or 550 °C for 8 h in air. Iodine retention after heat treatment was assessed by neutron activation analysis, showing retention of 67-100 % of expected iodine. The aqueous durabilities of the resulting materials were then determined, following the ASTM C1308 standard test, showing iodine releases of 1 to 23 g m-2 after 4 d. The cumulative iodine release for the best performing system (a zinc-bismuth-borate glass binder) was <1 g m-2, and its iodine retention from processing was 67 %. The iodine releases compared favorably with other waste forms. In parallel, this best-performing composition was also consolidated via hot isostatic pressing (HIP) in a stainless-steel canister at 550 °C for 2 h under 100 MPa pressure. The HIPed sample was produced at the ~20 g scale and showed improved densification and minimal reaction with the canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A non-hierarchical correlation discrete variable representation

The correlation discrete variable representation (CDVR) facilitates (multi-layer) multi-configurational time-dependent Hartree (MCTDH) calculations with general potentials. It employs a layered grid representation to efficiently evaluate all potential matrix elements appearing in the MCTDH equations of motion. The original CDVR approach and its multi-layer extension show a hierarchical structure: the size of the grids employed at the different layers increases when moving from an upper layer to a lower one. In this work, a non-hierarchical CDVR approach, which uses identically structured quadratures at all layers of the MCTDH wavefunction representation, is introduced. Here, the non-hierarchical CDVR approach crucially reduces the number of grid points required, compared to the hierarchical CDVR, shows superior scaling properties, and yields identical results for all three representations showing the same topology. Numerical tests studying the photodissociation of NOCl and the vibrational states of CH 3 demonstrate the accuracy of the non-hierarchical CDVR approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of Fe in long-range ordered Ni 2 Cr precipitates in Ni-Cr-Fe model alloys during isothermal aging

The precipitation of new phases during long-term service at elevated temperatures is a concern for the thermal stability of engineering alloys. In Ni-Cr-based alloys, e.g., Alloy 690, the formation of long-range ordered Ni 2 Cr causes embrittlement and may impact the lifetime of nuclear power plant components. In this work, we quantify the formation and evolution of Ni 2 Cr precipitation in eleven Ni-Cr-Fe model alloys with 0, 5, 7, and 10wt % Fe contents, and with Ni/Cr atomic ratios of 1.8, 2.0, 2.2, 2.4. These alloys were isothermally aged up to 10,000h at temperatures between 330 and 475°C. The alloys were characterized by synchrotron-based x-ray diffraction and Vickers hardness testing to quantify Ni 2 Cr precipitate size, and the impact of precipitate size on the mechanical properties as a function of Fe content. After 10,000 h of aging at 475°C and 418°C, the formation of Ni 2 Cr was observed in all alloys with 0 and 5wt % Fe. After 10,000h of aging at 418°C, Ni 2 Cr precipitates were also observed in the 7wt % Fe containing Ni/Cr=2.0 sample. Further, no clear evidence of Ni 2 Cr was observed in any of the 10wt % Fe samples at any time and temperature combination. We find that the face-centered cubic matrix lattice contraction and Vickers hardness are correlated with the Ni 2 Cr formation. The greatest change in hardness and lattice contraction occurs in stoichiometric alloys (Ni/Cr=2.0) with 0wt % Fe at 475°C. The rate of change in the material properties for the 5wt % Fe alloys is reduced, however the magnitude of changes is similar to 0wt % Fe alloys. A precipitation hardening model developed for Ni-Cr alloys based on critical resolved shear stress with weakly coupled dislocations shows a clear link between Ni 2 Cr precipitate size and hardness. This trend held across all alloys with Ni 2 Cr formation regardless of Fe concentration. This important structure-property relationship can potentially help define Ni-Cr-Fe-based component lifetimes directly through an understanding of how Ni 2 Cr formation impacts mechanical properties as a function of Fe content.

36 MATERIALS SCIENCE↗

Revisiting the three-kaon interaction and its relation with 𝐾⁡(1460)

Here, we test the hypothesis of 𝐾⁡(1460) being a hadronic 𝐽 𝑃 = 0 − molecule through nonperturbative 𝑆-wave $KK\bar{⁢K}$, 𝐾⁢𝜋⁢𝜋, 𝐾⁢𝜋⁢𝜂 coupled-channel dynamics in a three-body unitary isobar approach. The scalar two-body coupled-channel resonances 𝑓 0 ⁡(500), 𝑓 0 ⁡(980), 𝑎 0 ⁡(980), and 𝐾$^*_0$⁡(700) are generated in the subsytems in amplitudes that match phase shifts from experiment. In a first step, previous results in the limit of mass-degenerate, stable 𝑓 0 and 𝑎 0 isobars are reproduced. Once the full seven-coupled channel model is switched on, other 𝑆-matrix effects obscure and modify the resonance signal, including complex thresholds, a two-body cusp, and a triangle singularity at threshold.

Döring, M. [George Washington Univ., Washington, D↗

Resummation for lattice QCD calculation of generalized parton distributions at nonzero skewness

Large-momentum effective theory (LaMET) provides an approach to directly calculate the x-dependence of generalized parton distributions (GPDs) on a Euclidean lattice through power expansion and a perturbative matching. When a parton’s momentum becomes soft, the corresponding logarithms in the matching kernel become non-negligible at higher orders of perturbation theory, which requires a resummation. But the resummation for the off-forward matrix elements at nonzero skewness ξ is difficult due to their multi-scale nature. In this work, we demonstrate that these logarithms are important only in the threshold limit, and derive the threshold factorization formula for the quasi-GPDs in LaMET. We then propose an approach to resum all the large logarithms based on the threshold factorization, which is implemented on a GPD model. We demonstrate that the LaMET prediction is reliable for [−1 + x 0 , −ξ − x 0 ] ∪ [−ξ + x 0 , ξ − x 0 ] ∪ [ξ + x 0 , 1 − x 0 ], where x 0 is a cutoff depending on hard parton momenta. Through our numerical tests with the GPD model, we demonstrate that our method is self-consistent and that the inverse matching does not spread the nonperturbative effects or power corrections to the perturbatively calculable regions.

hadronic spectroscopy↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm &#x00d7; 5mm &#x00d7; 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 &#x00d7; 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Scalable qubit representations of neutrino mixing matrices

Oscillating neutrino beams exhibit quantum coherence over distances of thousands of kilometers. Their unambiguously quantum nature suggests an appealing test system for direct quantum simulation. Such techniques may enable presently analytically intractable calculations involving multi-neutrino entanglements, such as collective neutrino oscillations in supernovae, but only once oscillation phenomenology is properly re-expressed in the language of quantum circuits. Here we resolve outstanding conceptual issues regarding encoding of arbitrarily mixed neutrino flavor states in the Hilbert space of an n-qubit quantum computer. We introduce algorithms to encode mixing and oscillation of any number of flavor-mixed neutrinos, both with and without CP-violation, with an efficient number of prescriptive input parameters in terms of sub-rotations of the PMNS matrix in standard form. As a result, examples encoded for an IBM-Q quantum computer are shown to converge to analytic predictions both with and without CP-violation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

Investigation into Na and Cs activity coefficients in high salt solutions to support Cs removal in Hanford tank waste

The treatment of Hanford tank waste is one of the most technically challenging environmental cleanup activities for the U.S. Department of Energy to date. To expedite the processing of liquid waste stored in underground tanks in southeastern Washington state, it is necessary to remove the significant dose contributor, 137 Cs. Toward this effort, ion exchange with crystalline silicotitanate (CST) has been employed as part of the Tank Side Cesium Removal system. The model used to predict Cs exchange onto CST was developed using activity coefficients calculated from the Bromley equation. A series of batch contact tests that varied in [Na] were conducted to look at the impact of Na concentration on Cs distribution. Experimental distribution ratios ( K d ) were compared to the distribution ratios predicted using three different activity coefficient models: (1) commercially available HSC software, (2) the Bromley equation, and (3) a simplified approach adapted from Marcos-Arroyo et al. Ultimately, the Bromley method underpredicted the effect of ionic strength on the Na activity coefficient ( γ Na+ ), HSC overestimated the impact of ionic strength on the expected performance due to the Cs activity coefficient ( γ Cs+ ), but the simplified approach predicted the experimental K d values quite well in a binary matrix. In conclusion, expansion of this approach in complex matrices is necessary for application to Hanford tank waste.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of ceria-supported metal-oxide (MO x /CeO 2 ) catalysts via a one-pot chemical vapor deposition (OP-CVD) technique: Structure and reverse water gas shift reaction study

Current synthesis techniques for metal oxide (MO x )-supported catalysts have certain limitations of undesired target loading, ineffective dispersion of active species over the surface, uncontrolled particle size of active species, and complicated synthesis steps. Here, we developed a one-pot chemical vapor deposition (OP-CVD) methodology; by using which a solid metal precursor forms a vapor in a controlled condition and gets supported over the surrounding matrix. The theoretical stability followed by experimental validation using TGA is crucial for selecting the metal precursors. Three simple steps viz. premixing, dispersion, and rapid fixation by calcination are involved in the catalyst development via the OP-CVD approach. This study solely focused on the synthesis of 3d transition MO x over ceria support. The physicochemical characterizations of the prepared catalysts were performed by XRD, ICP-OES, SEM-EDX, CO pulse chemisorption, XANES, and EXAFS analyses to understand the crystal structure of involved species, target metal loading, dispersion, and particle size and prove the feasibility and viability of OP-CVD. The prepared catalysts were further tested for reverse water gas shift (RWGS) reaction to link their structural information with activity. The RWGS reaction data showed that the CO activity and CO selectivity were metal - and metal precursor-dependent. Higher CO activity of > 0.1 mol/h g-cat was observed for Cu and Co-based catalysts, with CO selectivity of ~100 %. This study provides an opportunity to produce efficient supported catalysts in a convenient way, providing effective catalytic activity.

36 MATERIALS SCIENCE↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Measurement of the Li 7 ( γ , t ) He 4 ground-state cross section between E γ = 4.4 and 10 MeV

Here, the Li 7 ( γ , t ) He 4 ground state cross section was measured for the first time using monoenergetic γ rays with energies between 4.4 and 10 MeV at the High Intensity Gamma-ray Source. The reaction is important for the primordial Li problem and for testing our understanding of the mirror α -capture reactions H 3 ( α , γ ) Li 7 and He 3 ( α , γ ) Be 7 . Although over the last 30 years most measurements of the H 3 ( α , γ ) Li 7 reaction have concentrated in an energy range below E γ = 3.65 MeV, measurements at higher energies could potentially restrict the extrapolation to astrophysically important energies. The experimental arrangement for measuring the Li 7 ( γ , t ) He 4 reaction included a large-area silicon detector array and several beam characterization instruments. The experimental astrophysical S factor of H 3 ( α , γ ) calculated from the present data was fitted using the R -matrix formalism. The results are in disagreement with previous experimental measurements in the same energy range but the extrapolated S factor agrees with the potential model calculation and lower energy experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analog-antianalog isospin mixing in 47 K 𝛽−decay

Here, we have measured the isospin mixing of the 𝐼 𝜋 =1/2 + , 𝐸 𝑥 = 2.599 MeV state in nearly doubly magic 47 Ca with the isobaric analog 1/2 + state of 47 K . Using the TRIUMF atom trap for 𝛽 decay, we have measured a nonzero asymmetry of the progeny 47 Ca with respect to the initial 47 K spin polarization, which together with the 𝛽 asymmetry implies a nonzero ratio of Fermi to Gamow-Teller matrix elements 𝑦 = 0.098 ± 0.037 for the 1/2 + → 1/2 + transition. Interpreting 𝑦 as mixing between this state and the isobaric analog state implies a Coulomb matrix element magnitude 101 ± 37 keV. This relatively large matrix element supports a model from the literature of analog-antianalog isospin mixing, which predicts large matrix elements in cases involving excess neutrons over protons occupying more than one major shell. The result supports pursuing a search for time-reversal odd, parity-even, isovector interactions using a correlation in 47 K 𝛽 decay.

beta decay↗

Vertical z-axis discontinuous carbon fibers for improved lightning strike performance of continuous fiber-reinforced polymer composites

Effective lightning strike protection for critical aerospace and wind applications requires high electrical conductivity to dissipate current efficiently. However, polymer matrix composites face a challenge due to their inherently insulating nature. While conventional carbon fiber-reinforced composites (CFRP) exhibit electrical conductivity in the planar direction, achieving through-thickness conductivity remains an ongoing challenge. In this work, we have undertaken the fabrication of CFRP interleaved with vertically oriented carbon fibers (Z-fiber) to impart higher electrical conductivity along the thickness direction. Two Z-fiber composite variations are prepared: Z-1 with a single layer of Z-fiber and Z-5 with five interleaved layers and compared with no Z-fiber layer (Z-0) composite. The composite panels were subjected to lab-scale lightning strike tests with a current magnitude of 100 kA. To emulate real-world service conditions, an aerospace-grade paint coating was applied to the composite laminates. Comparative analysis shows Z-1 reduces damage diameter to ∼22 mm compared to Z-0 (∼26 mm), while Z-5 exhibits the least damage (∼16.7 mm), confirmed by optical microscopy. Z-5 demonstrates nine times higher through-thickness electrical conductivity than Z-0, reducing electrical anisotropy substantially. Thermal-electric finite element damage modeling predicts surface damage within 6% of experimental values for both Z-0 and Z-5 composites. Flexural tests post-lightning reveal Z-5 retains 66% flexural strength and 86% modulus, significantly better than Z-0, which retains less than 40% for both properties. This study highlights the efficacy of Z-fiber composites in lightning strike protection, offering improved through-thickness conductivity and mechanical property retention.

36 MATERIALS SCIENCE↗

An implicit barotropic mode solver for MPAS-ocean using a modern Fortran solver interface

Here, we demonstrate use of a modern Fortran solver interface to manage solver algorithms for an implicit barotropic mode solver in the Model for Predictions Across Scales-Ocean (MPAS-O). ForTrilinos, a Fortran interface to Trilinos that contains a large collection of solver capabilities written in C++, has been implemented in MPAS-O to provide access to a suite of linear solver options. By virtue of the simplified wrapper and interface generator (SWIG) automation tool that generates modern Fortran interfaces to C++ code, we were able to implement the Fortran solver interface in MPAS-O using a familiar Fortran coding style while minimizing performance degradation. The ForTrilinos solver interface is written within MPAS-O’s time stepping modules as a subroutine in conjunction with MPAS-O code. Applied to an idealized ocean and a high-resolution realistic ocean test case, parallel performance of ForTrilinos solvers is examined. It is found that parallel scalability of the ForTrilinos solvers is highly dependent on the number of global synchronization points per solver iteration in each iterative solver algorithm. ForTrilinos solvers perform best compared to the Fortran hand-crafted (FHC) solver when the amount of work per processor is large enough. However, parallel scalability is better with the FHC solver and so when the work per core is modest FHC outperforms ForTrilinos. The intercomparison between the ForTrilinos and FHC solvers reveals that this performance hit in the ForTrilinos solver mostly comes from the global synchronization process, while suggesting that the matrix-vector multiplication process in the FHC solver needs to be optimized for better performance.

97 MATHEMATICS AND COMPUTING↗

Prioritization of Existing Reactor Materials

The Advanced Materials and Manufacturing Technologies (AMMT) Program is aiming at the faster incorporation of new materials and manufacturing technologies into complex nuclear-related systems. An integrated approach, combining advanced characterization, high-throughput and accelerated testing, modeling and simulation, including machine learning and artificial intelligence, will be employed. Although 316H (Fe–[16–18]Cr–[10–14]Ni–[2–3]Mo–[0.04–0.1]C) has been identified as a key alloy to be integrated into the AMMT accelerated alloy qualification approach because of its relevance for many current and future nuclear energy reactors, many other alloys could be considered for the advanced fabrication of innovative, high-performance nuclear components. Argonne National Laboratory (ANL), Idaho National Laboratory (INL), Oak Ridge National Laboratory (ORNL), and Pacific Northwest National Laboratory (PNNL) are collaborating on identifying the most promising alloy candidates relevant for the AMMT Program. A selection criteria matrix was established to evaluate the alloys considering their relative importance and technological readiness levels for nuclear energy applications, with a focus on laser powder bed fusion (LPBF). Because of the broad range of potential candidate alloys, ORNL and INL focused on nickel-based alloys, and ANL and PNNL mainly evaluated iron-based alloys. PNNL previously published material scorecards reports on several key alloys, and this report provides a broader overview of iron- and nickel-based candidate alloys, expending beyond alloys well-known to the nuclear community.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗